Bin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bin Zhang has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Limin Gao
5 shared publicationsJihong Zhu
4 shared publicationsJinju Sun
Department of Fluid Machinery and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
2 shared publicationsKaixun Jia
2 shared publications- Liqiang Ren
Department of Engineering Science and Mechanics, The Pennsylvania State University, USA
2 shared publications - Shi-Yang Tang
School of Mechanical and Manufacturing Engineering, The University of New South Wales, Sydney, NSW 2052, Australia
2 shared publications
Latest Publications
- 4 February 2026
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 155
Multilayer topology optimization of microfluidic heat sinks using non-Newtonian fluid for electronics cooling
- 4 February 2026
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 155
Multilayer topology optimization of microfluidic heat sinks using non-Newtonian fluid for electronics cooling
- Open Access
- 1 January 2026
- Published by Tech Science Press in Computer Modeling in Engineering & Sciences
- Vol. 148 (3) , 1-10
Topological Optimisation Design of Nanofluid-Cooled Microchannel Heat Sink Using a Three-Layer Thermofluid Model for Electronics Cooling
Nanofluid-cooled microchannel heat sinks (NCMHS) feature high heat dissipation efficiency and serve as a critical thermal management solution for electronic devices. This study employs a computationally efficient multi-layer modeling approach to conduct three-layer topological optimisation of the NCMHS. The flow and heat transfer within the NCMHS are described using a single-phase nanofluid-based thermofluid model that accounts for temperature-sensitive fluid properties. On this basis, a three-layer thermofluid model of the NCMHS is constructed by introducing assumptions regarding the velocity profile and an adaptive temperature profile in the thickness direction, together with the interlayer coupled heat flux derived from Fourier’s law. This model describes the conjugate heat transfer in the fluid channel and the heat conduction in the top and bottom plates in a two-dimensional manner, while comprehensively accounting for the influences of out-of-plane flow boundaries and heat transfer. Comparative validation against a full three-dimensional model demonstrates that the developed three-layer model achieves good numerical consistency. Based on this model, a three-layer topological optimisation framework for the NCMHS is further established by representing the channel layout with a fictitious density field. Numerical examples investigate the influences of temperature-sensitive fluid properties, pressure drop, heat source characteristics, and nanofluid properties on the optimized design of the NCMHS. The results elucidate that temperature-sensitive fluid properties significantly influence the optimized design. As the pressure drop increases, the optimized design tends to become more complex. In addition, reducing the nanoparticle volume fraction promotes the emergence of more branched channels in the optimized design.
- 1 January 2026
- Published by Tech Science Press in Computer Modeling in Engineering & Sciences
- Vol. 148 (3) , 1-10
Open AccessTopological Optimisation Design of Nanofluid-Cooled Microchannel Heat Sink Using a Three-Layer Thermofluid Model for Electronics Cooling
Nanofluid-cooled microchannel heat sinks (NCMHS) feature high heat dissipation efficiency and serve as a critical thermal management solution for electronic devices. This study employs a computationally efficient multi-layer modeling approach to conduct three-layer topological optimisation of the NCMHS. The flow and heat transfer within the NCMHS are described using a single-phase nanofluid-based thermofluid model that accounts for temperature-sensitive fluid properties. On this basis, a three-layer thermofluid model of the NCMHS is constructed by introducing assumptions regarding the velocity profile and an adaptive temperature profile in the thickness direction, together with the interlayer coupled heat flux derived from Fourier’s law. This model describes the conjugate heat transfer in the fluid channel and the heat conduction in the top and bottom plates in a two-dimensional manner, while comprehensively accounting for the influences of out-of-plane flow boundaries and heat transfer. Comparative validation against a full three-dimensional model demonstrates that the developed three-layer model achieves good numerical consistency. Based on this model, a three-layer topological optimisation framework for the NCMHS is further established by representing the channel layout with a fictitious density field. Numerical examples investigate the influences of temperature-sensitive fluid properties, pressure drop, heat source characteristics, and nanofluid properties on the optimized design of the NCMHS. The results elucidate that temperature-sensitive fluid properties significantly influence the optimized design. As the pressure drop increases, the optimized design tends to become more complex. In addition, reducing the nanoparticle volume fraction promotes the emergence of more branched channels in the optimized design.
- 2 February 2024
- Published by Springer Nature
- p. 244-250
Topology Optimization Design of Liquid-Cooled Radiator Based on Variable Density Method
- 2 February 2024
- Published by Springer Nature
- p. 244-250
Topology Optimization Design of Liquid-Cooled Radiator Based on Variable Density Method
- 26 January 2023
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 118, 272-302
Topology optimization of heat sink in turbulent natural convection using k-ω turbulent model
- 26 January 2023
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 118, 272-302
Topology optimization of heat sink in turbulent natural convection using k-ω turbulent model
- Open Access
- 1 February 2021
- Published by Elsevier in Chinese Journal of Aeronautics
- Vol. 34 (2) , 301-317
Design of nanofluid-cooled heat sink using topology optimization
- 1 February 2021
- Published by Elsevier in Chinese Journal of Aeronautics
- Vol. 34 (2) , 301-317
Open AccessDesign of nanofluid-cooled heat sink using topology optimization
- 1 March 2020
- Published by Elsevier in Fuel Processing Technology
- Vol. 199, 106290
Carbonaceous aerosols emission reduction by using red mud additive in coal briquette
- 1 March 2020
- Published by Elsevier in Fuel Processing Technology
- Vol. 199, 106290
Carbonaceous aerosols emission reduction by using red mud additive in coal briquette
- Open Access
- 1 January 2020
- Published by Wiley in BioMed Research International
- Vol. 2020 (1)
An Individualized Intra‐Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
We aimed to design an individualized intra-articular stabilization device based on 3D printing technology and investigate the clinical effects of this device for treating traumatic instability of the ulnohumeral joint. This study enrolled nine patients with traumatic instability of the ulnohumeral joint (age: ) who received treatment between March 2018 and March 2019 in our hospital. All patients underwent a thin-layer computed tomography (CT) scan of the elbow before surgery. The original injury and repair models of the elbow were printed using 3D printing technology based on CT data. An individualized intra-articular stabilization device was designed with a 2.0 mm Kirschner wire based on the repair model. Nine patients agreed to receive surgical treatment for elbow disease and placement of the intra-articular stabilization device. The nine patients underwent open reduction through a posterior median approach, and the intra-articular stabilization device was placed in the elbow. Operation time, intraoperative blood loss, and postoperative complications were recorded and followed up. The device was removed at two postoperative months, and the Mayo score was used to evaluate elbow function. Four months after removing the intra-articular stabilization device, elbow joint function was evaluated again using the Mayo score. The mean operation time was , and the mean intraoperative blood loss was . No complications occurred after operation. Two months after surgery, eight patients received an excellent Mayo score, and one patient received a good Mayo score. Four months after removal of the intra-articular stabilization device, eight patients received an excellent Mayo score, and one patient received a good Mayo score. The individualized intra-articular stabilization device can increase ulnohumeral stability and achieve rapid functional recovery of the elbow.
- 1 January 2020
- Published by Wiley in BioMed Research International
- Vol. 2020 (1)
Open AccessAn Individualized Intra‐Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint
We aimed to design an individualized intra-articular stabilization device based on 3D printing technology and investigate the clinical effects of this device for treating traumatic instability of the ulnohumeral joint. This study enrolled nine patients with traumatic instability of the ulnohumeral joint (age: ) who received treatment between March 2018 and March 2019 in our hospital. All patients underwent a thin-layer computed tomography (CT) scan of the elbow before surgery. The original injury and repair models of the elbow were printed using 3D printing technology based on CT data. An individualized intra-articular stabilization device was designed with a 2.0 mm Kirschner wire based on the repair model. Nine patients agreed to receive surgical treatment for elbow disease and placement of the intra-articular stabilization device. The nine patients underwent open reduction through a posterior median approach, and the intra-articular stabilization device was placed in the elbow. Operation time, intraoperative blood loss, and postoperative complications were recorded and followed up. The device was removed at two postoperative months, and the Mayo score was used to evaluate elbow function. Four months after removing the intra-articular stabilization device, elbow joint function was evaluated again using the Mayo score. The mean operation time was , and the mean intraoperative blood loss was . No complications occurred after operation. Two months after surgery, eight patients received an excellent Mayo score, and one patient received a good Mayo score. Four months after removal of the intra-articular stabilization device, eight patients received an excellent Mayo score, and one patient received a good Mayo score. The individualized intra-articular stabilization device can increase ulnohumeral stability and achieve rapid functional recovery of the elbow.
- 28 May 2019
- Published by Springer Nature in Structural and Multidisciplinary Optimization
- Vol. 60 (5) , 1821-1840
Topology optimization of convective heat transfer problems for non-Newtonian fluids
- 28 May 2019
- Published by Springer Nature in Structural and Multidisciplinary Optimization
- Vol. 60 (5) , 1821-1840
Topology optimization of convective heat transfer problems for non-Newtonian fluids
- Open Access
- 21 July 2017
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 21 (8) , 1-12
Acoustofluidic waveguides for localized control of acoustic wavefront in microfluidics
The precise manipulation of acoustic fields in microfluidics is of critical importance for the realization of many biomedical applications. Despite the tremendous efforts devoted to the field of acoustofluidics during recent years, dexterous control, with an arbitrary and complex acoustic wavefront, in a prescribed, microscale region is still out of reach. Here, we introduce the concept of acoustofluidic waveguide, a three-dimensional compact configuration that is capable of locally guiding acoustic waves into a fluidic environment. Through comprehensive numerical simulations, we revealed the possibility of forming complex field patterns with defined pressure nodes within a highly localized, pre-determined region inside the microfluidic chamber. We also demonstrated the tunability of the acoustic field profile through controlling the size and shape of the waveguide geometry, as well as the operational frequency of the acoustic wave. The feasibility of the waveguide concept was experimentally verified via microparticle trapping and patterning. Our acoustofluidic waveguiding structures can be readily integrated with other microfluidic configurations and can be further designed into more complex types of passive acoustofluidic devices. The waveguide platform provides a promising alternative to current acoustic manipulation techniques and is useful in many applications such as single-cell analysis, point-of-care diagnostics, and studies of cell–cell interactions.
- 21 July 2017
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 21 (8) , 1-12
Open AccessAcoustofluidic waveguides for localized control of acoustic wavefront in microfluidics
The precise manipulation of acoustic fields in microfluidics is of critical importance for the realization of many biomedical applications. Despite the tremendous efforts devoted to the field of acoustofluidics during recent years, dexterous control, with an arbitrary and complex acoustic wavefront, in a prescribed, microscale region is still out of reach. Here, we introduce the concept of acoustofluidic waveguide, a three-dimensional compact configuration that is capable of locally guiding acoustic waves into a fluidic environment. Through comprehensive numerical simulations, we revealed the possibility of forming complex field patterns with defined pressure nodes within a highly localized, pre-determined region inside the microfluidic chamber. We also demonstrated the tunability of the acoustic field profile through controlling the size and shape of the waveguide geometry, as well as the operational frequency of the acoustic wave. The feasibility of the waveguide concept was experimentally verified via microparticle trapping and patterning. Our acoustofluidic waveguiding structures can be readily integrated with other microfluidic configurations and can be further designed into more complex types of passive acoustofluidic devices. The waveguide platform provides a promising alternative to current acoustic manipulation techniques and is useful in many applications such as single-cell analysis, point-of-care diagnostics, and studies of cell–cell interactions.