JBJi Yong Bae

Ji Yong Bae

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ji Yong Bae has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Novel Drug‐Testing Platform for Vascular Injury‐induced Intimal Hyperplasia Using a Microphysiological System

    by Ungsig Nam, HyeMi Kim, Jeong Ah Kim, Ki‐Hwan Nam, Kye‐Sung Lee, Hwan Hur, Jessie S. Jeon, Ji Yong Bae

    Drug‐coated balloons (DCBs) and drug‐eluting stents (DESs) with antiproliferative drugs have been developed to prevent restenosis. However, some patients who undergo DCB or DES procedures still experience restenosis. Therefore, it is essential to explore therapeutic agents for DCBs and DESs. Furthermore, alternative platforms addressing current experimental model limitations are necessary for disease research. Here, a 3D model of vascular injury‐induced intimal hyperplasia is developed by using a microphysiological system (MPS). This model effectively replicated the endothelial denudation, proliferation, and migration of vascular smooth muscle cells (VSMCs), and vascular inflammation associated with the disease. Using this disease model, it is shown that antiproliferative drugs suppress VSMC proliferation but worsen endothelial denudation. In addition, potential alternatives are investigated to antiproliferative drugs and tested various drugs aimed at reducing inflammation. Partial improvements are found in VSMCs treated with DPI and in the endothelium treated with quercetin. When diphenyleneiodonium (DPI) and quercetin are combined, VSMC proliferation, migration, and vascular inflammation are reduced without impairing re‐endothelialization. This disease model shows promise; this study may offer new treatment insights for DCBs and DESs.

  • Open Access

    Model Predictive Control of Time-Varying Aberrations for Sensorless Adaptive Optics

    by Jinsung Kim, Kye-Sung Lee, Sang-Chul Lee, Ji Yong Bae, Dong Uk Kim, I. Jong Kim, Ki Soo Chang, Hwan Hur

    We propose a model predictive control (MPC) method to compensate for the time-varying phase aberrations in a sensorless adaptive optics (AO) system. The approximate model for the point spread function (PSF) of the imaging system with phase diversity is mathematically derived, and its validity is verified. The proposed MPC, which considers the operating limits of the deformable mirror (DM), computes the optimal applied voltage of each actuator over a prediction horizon, and the receding horizon scheme is applied as feedback control. Numerical case studies with the time-varying phase aberrations generated by an atmospheric turbulence simulator are presented to demonstrate the correction performance of the MPC strategy. The proposed method caused a 50% improvement in the reduction in residual aberration, making it competitive with a saturation linear quadratic regulator (LQR). The computational feasibility of the proposed method is validated using fast MPC, which approximates the primal barrier method.


  • Open Access

    Wide‐field photothermal reflectance spectroscopy for single nanoparticle absorption spectrum analysis

    by Jung‐Dae Kim, Dong Uk Kim, Chan Bae Jeong, Ilkyu Han, Ji Yong Bae, Hwan Hur, Ki‐Hwan Nam, Sangwon Hyun, I Jong Kim, Kye‐Sung Lee, et al.

    Photothermal imaging is useful for detecting individual nanoparticles and obtaining the absorption spectra. This study presents a wide‐field photothermal reflectance spectroscopy technique achieved by incorporating a pump beam, a probe beam, and a charge‐coupled device (CCD) camera into a commercial microscopic setup. The presented design does not require precise alignment between the pump and the probe beams and enables the observation of numerous individual nanoparticles during image acquisition. Despite the use of a simple imaging processing method, i.e., a four‐bucket method using a CCD camera, sufficient sensitivity for the spectral imaging of a single gold nanorod (20 nm diameter and 84 nm length) is demonstrated. Numerous individual nanoparticles within a wide field of view (240 μm × 180 μm) are detected in an image captures at an imaging measurement speed of 0.02 mm 2 min −1 . Furthermore, the proposed photothermal reflectance spectroscopy technique can detect the variation in the absorption peak of the measured spectra depending on the aspect ratio of individual nanoparticles within a spectral resolution of 1 nm.


  • Open Access

    Quantitative Photothermal Characterization with Bioprinted 3D Complex Tissue Constructs for Early‐Stage Breast Cancer Therapy Using Gold Nanorods

    by Ki‐Hwan Nam, Chan Bae Jeong, HyeMi Kim, Minjun Ahn, Sung‐Jun Ahn, Hwan Hur, Dong Uk Kim, Jinah Jang, Hui‐Jeong Gwon, Youn‐Mook Lim, et al.

    Plasmonic photothermal therapy (PPTT) using gold nanoparticles (AuNPs) has shown great potential for use in selective tumor treatment, because the AuNPs can generate destructive heat preferentially upon irradiation. However, PPTT using AuNPs has not been added to practice, owing to insufficient heating methods and tissue temperature measurement techniques, leading to unreliable and inaccurate treatments. Because the photothermal properties of AuNPs vary with laser power, particle optical density, and tissue depth, the accurate prediction of heat generation is indispensable for clinical treatment. In this report, bioprinted 3D complex tissue constructs comprising processed gel obtained from porcine skin and human decellularized adipose tissue are presented for characterization of the photothermal properties of gold nanorods (AuNRs) having an aspect ratio of 3.7 irradiated by a near‐infrared laser. Moreover, an analytical function is suggested for achieving PPTT that can cause thermal damage selectively on early‐stage human breast cancer by regulating the heat generation of the AuNRs in the tissue.


  • Open Access

    Design, Fabrication, and Performance Evaluation of Portable and Large-Area Blackbody System

    by Ji Yong Bae, Won Choi, Suk-Ju Hong, Sangyeon Kim, Eungchan Kim, Chang-Hyup Lee, Yun-Hyeok Han, Hwan Hur, Kye-Sung Lee, Ki Soo Chang, et al.

    In this study, a portable and large-area blackbody system was developed following a series of processes including design, computational analysis, fabrication, and experimental analysis and evaluation. The blackbody system was designed to be lightweight (5 kg), and its temperature could exceed the ambient temperature by up to 15 °C under operation. A carbon-fiber-based heat source was used to achieve a uniform temperature distribution. A heat shield fabricated from an insulation material was embedded at the opposite side of the heating element to minimize heat loss. A prototype of the blackbody system was fabricated based on the design and transient coupled electro-thermal simulation results. The operation performance of this system, such as the thermal response, signal transfer function, and noise equivalent temperature difference, was evaluated by employing an infrared imaging system. In addition, emissivity was measured during operation. The results of this study show that the developed portable and large-area blackbody system can be expected to serve as a reliable reference source for the calibration of aerial infrared images for the application of aerial infrared techniques to remote sensing.


  • Open Access

    Development of a Reflective 193-nm DUV Microscope System for Defect Inspection of Large Optical Surfaces

    by Hong-Seung Kim, Dong-Ho Lee, Sangwon Hyun, Soon Kyu Je, June Gyu Park, Ji Yong Bae, Geon Hee Kim, I Jong Kim

    We developed a 193-nm deep ultraviolet (DUV) microscope system based on the reflection mode for a precise inspection of various types of defects/cracks on large optical surfaces of the order of one meter in size. Without preprocessing the sample at room temperature and atmospheric pressure, which is commonly necessary for electron microscopy, the reflective 193-nm DUV microscope was used to directly observe optical surface defects in a manner similar to conventional optical microscopes. In addition, the limitations on the selection of materials and thickness of optical samples of transmittive DUV microscopes were overcome. DUV microscope imaging and the analysis on the spatial resolution were verified using a 1D grating structure with a 225-nm line width. This system could be widely applied as an inspection tool because it provides high resolution at the 200-nm scale that is close to the diffraction limit of a 193-nm DUV beam. In the near future, it is expected that our system would be extended to nano/bio imaging as well as the inspection of large optical surfaces.


  • Influence of Morphological Homogeneity of Superspherical Gold Nanoparticles on Plasmonic Photothermal Heat Generation

    by Ji Yong Bae, Dae‐Woong Jung, Chan Bae Jeong, Hong‐Seung Kim, Jung Dae Kim, Hyun‐Joo Ro, Sangmi Jun, Dong Uk Kim, Gi‐Ra Yi, Gaehang Lee, et al.

    The plasmonic photothermal (PPT) characteristics of gold nanostructures have been extensively investigated theoretically and experimentally due to their potential for use materials science and industry. The management of the size and shape of gold nanoparticles has been a key issue in the development of better solutions for PPT heat generation because their size and shape determine their resultant photothermal properties. However, the light absorption of gold nanostructures is mainly dependent on the wavelength and orientation of the incident light; hence, maintaining uniform size and shape is critical for achieving maximum photothermal energy. Morphologically homogeneous spherical gold nanoparticles, or super gold nanospheres prepared by slowly etching uniform octahedral gold nanoparticles, demonstrate better PPT heat generation compared with commercially available nonsmooth gold nanoparticles (GNSs). The PPT heating experiments show a maximum temperature difference of 5.7 °C between the super and ordinary GNSs with the same average maximum Feret's diameters, which result from the more efficient PPT heat power generation (20.6%) of the super GNSs. In an electromagnetic‐wave simulation, the super GNSs show lower polarization dependence and a 24.6% higher absorption cross‐section than ordinary GNSs.


  • Open Access

    3D Defect Localization on Exothermic Faults within Multi-Layered Structures Using Lock-In Thermography: An Experimental and Numerical Approach

    by Ji Yong Bae, Kye-Sung Lee, Hwan Hur, Ki-Hwan Nam, Suk-Ju Hong, Ah-Yeong Lee, Ki Soo Chang, Geon-Hee Kim, Ghiseok Kim

    Micro-electronic devices are increasingly incorporating miniature multi-layered integrated architectures. However, the localization of faults in three-dimensional structure remains challenging. This study involved the experimental and numerical estimation of the depth of a thermally active heating source buried in multi-layered silicon wafer architecture by using both phase information from an infrared microscopy and finite element simulation. Infrared images were acquired and real-time processed by a lock-in method. It is well known that the lock-in method can increasingly improve detection performance by enhancing the spatial and thermal resolution of measurements. Operational principle of the lock-in method is discussed, and it is represented that phase shift of the thermal emission from a silicon wafer stacked heat source chip (SSHSC) specimen can provide good metrics for the depth of the heat source buried in SSHSCs. Depth was also estimated by analyzing the transient thermal responses using the coupled electro-thermal simulations. Furthermore, the effects of the volumetric heat source configuration mimicking the 3D through silicon via integration package were investigated. Both the infrared microscopic imaging with the lock-in method and FE simulation were potentially useful for 3D isolation of exothermic faults and their depth estimation for multi-layered structures, especially in packaged semiconductors.