Qiang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qiang Liu has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Wen Nie
6 shared publicationsYun Hua
6 shared publicationsChuanxing Cheng
College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266590, Shandong Province, China; State Key Laboratory of Mining Disaster Prevention and Control Co-found by Shandong Province and the Ministry of Science and Technology, Shandong University of Science and Technology, Qingdao 266590, China
5 shared publicationsLidian Guo
5 shared publicationsChenwang Jiang
College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao, China
4 shared publicationsHaonan Zhang
College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao 266590, Shandong Province, China; State Key Laboratory of Mining Disaster Prevention and Control Co-found by Shandong Province and the Ministry of Science and Technology, Shandong University of Science and Technology, Qingdao 266590, China
4 shared publications
Latest Publications
- 24 March 2025
- Published by Elsevier in Science of The Total Environment
- Vol. 974, 178966
Research on dust diffusion reduction-control technology of wind guide hood system based on an improved tunnel pressurized air system
- 24 March 2025
- Published by Elsevier in Science of The Total Environment
- Vol. 974, 178966
Research on dust diffusion reduction-control technology of wind guide hood system based on an improved tunnel pressurized air system
- 22 June 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (31) , 43712-43730
Study of dust pollution control effect based on orthogonal test and CFD numerical simulations
To control the diffusion of high concentrations of coal dust during tunnel boring and minimize the threat to the life and health of coal miners, theoretical analysis, numerical simulations, and field measurements were combined in this study. First, computational fluid dynamic simulation software was used to simulate the generation of dust particles and their transport pattern in the tunnel. Subsequently, an innovative orthogonal test was performed to study the effect of four ventilation parameters [the pressure airflow rate (Q), distance between the air duct center and heading face (LA), distance between the air duct center and tunnel floor (LB), and distance between the air duct center and nearest coal wall (LC)] on dust diffusion. According to the orthogonal test results, the optimal ventilation parameters for effective dust control are as follows: Q = 1400 m3/min, LA = 7 m, LB = 2.8 m, and LC = 1 m. The optimized set of ventilation parameters was applied to the Wangpo 3206 working face. The results show that dust diffusion in the tunnel was effectively controlled and that the air quality was sufficiently improved.
- 22 June 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (31) , 43712-43730
Study of dust pollution control effect based on orthogonal test and CFD numerical simulations
To control the diffusion of high concentrations of coal dust during tunnel boring and minimize the threat to the life and health of coal miners, theoretical analysis, numerical simulations, and field measurements were combined in this study. First, computational fluid dynamic simulation software was used to simulate the generation of dust particles and their transport pattern in the tunnel. Subsequently, an innovative orthogonal test was performed to study the effect of four ventilation parameters [the pressure airflow rate (Q), distance between the air duct center and heading face (LA), distance between the air duct center and tunnel floor (LB), and distance between the air duct center and nearest coal wall (LC)] on dust diffusion. According to the orthogonal test results, the optimal ventilation parameters for effective dust control are as follows: Q = 1400 m3/min, LA = 7 m, LB = 2.8 m, and LC = 1 m. The optimized set of ventilation parameters was applied to the Wangpo 3206 working face. The results show that dust diffusion in the tunnel was effectively controlled and that the air quality was sufficiently improved.
- Top Cited Papers
Coupled diffusion law of windflow-gas-dust in tunnel energy extraction processes and the location of optimal pollution control exhaust duct
- 12 April 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 928, 172428
Study of spatiotemporal evolution of coupled airflow–gas–dust multi-field diffusion at low-gas tunnel
- 12 April 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 928, 172428
Study of spatiotemporal evolution of coupled airflow–gas–dust multi-field diffusion at low-gas tunnel
- 15 March 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 87, 109025
Numerical simulation of the dust pollution characteristics and the optimal dustproof air volume in coal washing plant screening workshop
- 15 March 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 87, 109025
Numerical simulation of the dust pollution characteristics and the optimal dustproof air volume in coal washing plant screening workshop
- Open Access
- 7 May 2023
- Published by Aerospace Information Research Institute, Chinese Academy of Sciences in National Remote Sensing Bulletin
- Vol. 27 (5) , 1177-1193
The near-space altitude experiment for satellite radiometric calibration and the first results
- 7 May 2023
- Published by Aerospace Information Research Institute, Chinese Academy of Sciences in National Remote Sensing Bulletin
- Vol. 27 (5) , 1177-1193
Open AccessThe near-space altitude experiment for satellite radiometric calibration and the first results
- 28 May 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (49) , 74097-74117
Study on dust–gas coupling pollution law and selection of optimal purification distance of air duct during tunneling process
During the excavation of high gas mine, gas and dust often exist at the same time. In order to ensure that the gas concentration remains within a safe range and minimize the risk of workers’ pneumoconiosis, we simulated the interaction mechanism of airflow, gas, and dust, explored the pollution law of gas and dust, and obtained the optimal purification distance (Lp) by the CFD method. The reliability of the numerical simulation was verified by field measurements. Firstly, the properties of the gas and dust affected the structure of the airflow field. At the same time, the change in the airflow field affected the concentration distributions of the gas and dust. During the diffusion process, some high-risk regions in which the gas or dust concentrations exceeded 0.80% or 200 mg/m3, respectively, were discovered. Moreover, we have found that the airflow velocity in the top region of the tunnel and at the intersection corner between the cutting face and tunnel wall was the main factor affecting the purification effects. When Lp = 5–8 m, the gas concentration remained below 0.50%. When Lp = 6 m, the dust concentration reached a minimum of 287.5 mg/m3. Therefore, the optimal purification distance was determined to be 6 m; in which case, the gas and dust concentrations decreased by 32.84% and 47.02%, respectively.
- 28 May 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (49) , 74097-74117
Study on dust–gas coupling pollution law and selection of optimal purification distance of air duct during tunneling process
During the excavation of high gas mine, gas and dust often exist at the same time. In order to ensure that the gas concentration remains within a safe range and minimize the risk of workers’ pneumoconiosis, we simulated the interaction mechanism of airflow, gas, and dust, explored the pollution law of gas and dust, and obtained the optimal purification distance (Lp) by the CFD method. The reliability of the numerical simulation was verified by field measurements. Firstly, the properties of the gas and dust affected the structure of the airflow field. At the same time, the change in the airflow field affected the concentration distributions of the gas and dust. During the diffusion process, some high-risk regions in which the gas or dust concentrations exceeded 0.80% or 200 mg/m3, respectively, were discovered. Moreover, we have found that the airflow velocity in the top region of the tunnel and at the intersection corner between the cutting face and tunnel wall was the main factor affecting the purification effects. When Lp = 5–8 m, the gas concentration remained below 0.50%. When Lp = 6 m, the dust concentration reached a minimum of 287.5 mg/m3. Therefore, the optimal purification distance was determined to be 6 m; in which case, the gas and dust concentrations decreased by 32.84% and 47.02%, respectively.
- 18 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (23) , 34943-34954
Design and application of a dust suppression technology of the forcing air curtain in fully mechanized rock tunnelling faces
To effectively reduce high dust concentrations and keep clean air in fully mechanized rock tunnelling faces in coal mine, this study carried out a research of dust suppression technology of the forcing air curtain. First, the mechanism of dust diffusion controlled by the forcing air curtain was introduced in this study. Then, numerical simulations of the formation of the forcing air curtain as well as the influence for dust diffusion under the different distance between forcing air duct outlet and heading end were carried out. Moreover, a dust suppression technology of the forcing air curtain was designed and tested in a fully mechanized rock tunnelling face of southern return air tunnel which was located in the Tangkou coal mine of China. It shows that the numerical simulation results were in good agreement with the in situ tests. The average removal rate of total and respirable dust could reach up to 95.1% and 96.1%, respectively, at manned working areas in the tunnel. Research results show that the dust suppression technology of the forcing air curtain is an effective method of dust control in fully mechanized rock tunnelling faces.
- 18 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (23) , 34943-34954
Design and application of a dust suppression technology of the forcing air curtain in fully mechanized rock tunnelling faces
To effectively reduce high dust concentrations and keep clean air in fully mechanized rock tunnelling faces in coal mine, this study carried out a research of dust suppression technology of the forcing air curtain. First, the mechanism of dust diffusion controlled by the forcing air curtain was introduced in this study. Then, numerical simulations of the formation of the forcing air curtain as well as the influence for dust diffusion under the different distance between forcing air duct outlet and heading end were carried out. Moreover, a dust suppression technology of the forcing air curtain was designed and tested in a fully mechanized rock tunnelling face of southern return air tunnel which was located in the Tangkou coal mine of China. It shows that the numerical simulation results were in good agreement with the in situ tests. The average removal rate of total and respirable dust could reach up to 95.1% and 96.1%, respectively, at manned working areas in the tunnel. Research results show that the dust suppression technology of the forcing air curtain is an effective method of dust control in fully mechanized rock tunnelling faces.
- 14 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (22) , 33627-33644
Research on environmental dust pollution: ventilation and dust space–time evolution law of a fully mechanized mining face with 7-m mining height
To investigate the influence of dust produced by multi-dust sources at a fully mechanized mining face with a large mining height on the safety conditions in a coal mine, the No. 22305 fully mechanized mining face of the Bulianta coal mine was considered as the research object in this study, and the space–time evolution of dust was analyzed with computational fluid dynamics (CFD). The wind flow simulation results show that the distribution law of wind flow is mainly affected by the structure of the roadway, and the speed and direction of the wind flow change greatly while passing by corners and through large-scale equipment. The dust generation and pollution diffusion laws with respect to time and space were investigated based on simulations of dust production due to 5-s, 30-s, and 60-s coal cutting, continuous coal cutting, and hydraulic support shifting. The space–time evolution law under different dust-producing times shows the transportation and diffusion procedure of dust under the wind flow; the dust-generated via coal mining and shifting were superposed on the downwind side and a 36-m-long dust belt was formed, which filled the coal mining space; the dust concentration in the breathing zone 120 m downwind the front drum had a dust concentration higher than 1700 mg/m3, this was the crucial dust-proof area, and effective dust reduction methods should be addressed.
- 14 January 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (22) , 33627-33644
Research on environmental dust pollution: ventilation and dust space–time evolution law of a fully mechanized mining face with 7-m mining height
To investigate the influence of dust produced by multi-dust sources at a fully mechanized mining face with a large mining height on the safety conditions in a coal mine, the No. 22305 fully mechanized mining face of the Bulianta coal mine was considered as the research object in this study, and the space–time evolution of dust was analyzed with computational fluid dynamics (CFD). The wind flow simulation results show that the distribution law of wind flow is mainly affected by the structure of the roadway, and the speed and direction of the wind flow change greatly while passing by corners and through large-scale equipment. The dust generation and pollution diffusion laws with respect to time and space were investigated based on simulations of dust production due to 5-s, 30-s, and 60-s coal cutting, continuous coal cutting, and hydraulic support shifting. The space–time evolution law under different dust-producing times shows the transportation and diffusion procedure of dust under the wind flow; the dust-generated via coal mining and shifting were superposed on the downwind side and a 36-m-long dust belt was formed, which filled the coal mining space; the dust concentration in the breathing zone 120 m downwind the front drum had a dust concentration higher than 1700 mg/m3, this was the crucial dust-proof area, and effective dust reduction methods should be addressed.