Anastasia Gant Kanegusuku
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anastasia Gant Kanegusuku has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Jennifer L. Roizen
Duke University, Department of Chemistry, Box 90346, Durham, North Carolina 27708-0354, United States
9 shared publications - Georgia Scott
Department of Chemistry, Duke University, Box 90346, Durham, North Carolina 27708-0354, United States
4 shared publications - Katherine Andrea Araque
National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland
3 shared publications - Suraj K. Ayer
Duke University , Department of Chemistry , Box 90346, Durham , North Carolina 27708-0354 , United States
3 shared publications - Thomas Castanheiro
Univ. Rouen Normandie INSA Rouen Normandie Univ. Caen Normandie ENSICAEN, CNRS Institute CARMeN UMR Rouen France
3 shared publications - Jack A. Maggiore
Department of Pathology and Laboratory Medicine, Loyola University Medical Center , Maywood, IL
2 shared publications
Latest Publications
- 14 November 2025
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 164 (6) , 849-853
The no-body problem: evaluation of OrganOx-generated liver perfusate for matrix effects on routine chemistry assays on the Beckman Coulter AU5800 series automated platform
Objective: The OrganOx metra is a recent innovation approved by the US Food and Drug Administration that enables continuous ex vivo perfusion of a donor liver prior to transplantation. A mixture of human blood products, added nutrients, and drugs is perfused throughout the liver to sustain its viability. This study determines whether the perfusate matrix affects the analytical accuracy of biochemical parameters used to evaluate the function of the donor liver before transplantation. Methods: A mixing study was conducted to evaluate the percent recovery of total bilirubin, aspartate aminotransferase, alanine aminotransferase, lactic acid, glucose, and lactate dehydrogenase in OrganOx metra perfusate using the Beckman Coulter AU5800 automated platform. Perfusate pools were mixed with pooled patient plasma (Li Hep) in the following ratios: 1:4, 1:1, and 4:1. These mixtures were measured alongside straight patient plasma and straight perfusate. Results: Agreement between expected and measured values, with a percent recovery for all tested analytes, was between 92% and 109%. Detrimental matrix effects were not observed. Conclusions: The Beckman Coulter AU5800 analyzer provides reliable and accurate biochemical analysis of OrganOx metra perfusate during ex vivo preservation. The findings validate its suitability for perfusate analysis, supporting its potential use in clinical and research settings.
- 14 November 2025
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 164 (6) , 849-853
The no-body problem: evaluation of OrganOx-generated liver perfusate for matrix effects on routine chemistry assays on the Beckman Coulter AU5800 series automated platform
Objective: The OrganOx metra is a recent innovation approved by the US Food and Drug Administration that enables continuous ex vivo perfusion of a donor liver prior to transplantation. A mixture of human blood products, added nutrients, and drugs is perfused throughout the liver to sustain its viability. This study determines whether the perfusate matrix affects the analytical accuracy of biochemical parameters used to evaluate the function of the donor liver before transplantation. Methods: A mixing study was conducted to evaluate the percent recovery of total bilirubin, aspartate aminotransferase, alanine aminotransferase, lactic acid, glucose, and lactate dehydrogenase in OrganOx metra perfusate using the Beckman Coulter AU5800 automated platform. Perfusate pools were mixed with pooled patient plasma (Li Hep) in the following ratios: 1:4, 1:1, and 4:1. These mixtures were measured alongside straight patient plasma and straight perfusate. Results: Agreement between expected and measured values, with a percent recovery for all tested analytes, was between 92% and 109%. Detrimental matrix effects were not observed. Conclusions: The Beckman Coulter AU5800 analyzer provides reliable and accurate biochemical analysis of OrganOx metra perfusate during ex vivo preservation. The findings validate its suitability for perfusate analysis, supporting its potential use in clinical and research settings.
- 3 January 2025
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 10 (1) , 66-72
Teaching the Laboratory’s Role in Diagnostic Stewardship: Engaging Pathology Residents in a Quality Initiative to Improve Autoverification Rates
Background: Our institution involves our pathology residents in departmental quality initiatives and in identifying needs for operational improvements. The solutions achieved by these projects have effects beyond the laboratory, and ultimately help to improve diagnostic stewardship by supporting the clinician’s ability to obtain necessary biochemical information at the right time. A project highlighting a successful venture is described here in which our investment in new total laboratory automation was not meeting our goals for autoverification rates, resulting in less than expected improvements to turnaround times (TAT). Methods: To improve efficiency of the new laboratory automation, our third-year pathology residents examined the limitations to the verification process and current delta checks. They performed a literature review for the most updated evidence-based practices, examined clinical metrics such as TAT. The residents assessed their findings combined with the laboratory’s quality goals, and contributed to updating middleware rule modifications. Several chemistry analyte software rules were revised while others were eliminated. Results: After implementation of the modifications autoverification rates improved from 78% to 89% within 2 months of rule revisions. Average TAT for STAT basic metabolic profile improved from 51 to 46 minutes. Conclusions: This study demonstrates the benefits of involving pathology residents in quality improvement initiatives. Residents are skilled resources capable of evaluating laboratory workflow processes in the context of clinical need. In this process, the residents experience the responsibilities of laboratory administration and learn the role of the laboratory in diagnostic stewardship.
- 3 January 2025
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 10 (1) , 66-72
Teaching the Laboratory’s Role in Diagnostic Stewardship: Engaging Pathology Residents in a Quality Initiative to Improve Autoverification Rates
Background: Our institution involves our pathology residents in departmental quality initiatives and in identifying needs for operational improvements. The solutions achieved by these projects have effects beyond the laboratory, and ultimately help to improve diagnostic stewardship by supporting the clinician’s ability to obtain necessary biochemical information at the right time. A project highlighting a successful venture is described here in which our investment in new total laboratory automation was not meeting our goals for autoverification rates, resulting in less than expected improvements to turnaround times (TAT). Methods: To improve efficiency of the new laboratory automation, our third-year pathology residents examined the limitations to the verification process and current delta checks. They performed a literature review for the most updated evidence-based practices, examined clinical metrics such as TAT. The residents assessed their findings combined with the laboratory’s quality goals, and contributed to updating middleware rule modifications. Several chemistry analyte software rules were revised while others were eliminated. Results: After implementation of the modifications autoverification rates improved from 78% to 89% within 2 months of rule revisions. Average TAT for STAT basic metabolic profile improved from 51 to 46 minutes. Conclusions: This study demonstrates the benefits of involving pathology residents in quality improvement initiatives. Residents are skilled resources capable of evaluating laboratory workflow processes in the context of clinical need. In this process, the residents experience the responsibilities of laboratory administration and learn the role of the laboratory in diagnostic stewardship.
- 10 August 2024
- Published by Oxford University Press (OUP) in Laboratory Medicine
- Vol. 56 (2) , 129-135
Analytical evaluation of the automated interleukin-6 assay on the Roche cobas e602 analyzer
Interleukin-6 (IL-6) is a proinflammatory cytokine that is associated with many inflammatory diseases. This validation study evaluates the automated Roche Elecsys IL-6 electrochemiluminescent immunoassay that has been granted emergency use authorization by the US Food and Drug Administration. The Elecsys IL-6 assay was evaluated for precision, linearity, interference (by hemoglobin, bilirubin, triglycerides, and biotin) and clinical performance was compared to the V-PLEX Human IL-6 immunoassay (Meso Scale Discovery), performed by a reference laboratory. The Elecsys IL-6 assay is precise (intra-assay 2 = 0.84). Bland-Altman analysis revealed an absolute mean bias of 152 pg/mL (SD = 254 pg/mL), or a mean percentage difference of 73%. The Roche IL-6 assay showed good analytical performance. The large systematic bias compared with another reference method precludes using multiple methods to monitor IL-6 response. The random-access nature of an automated IL-6 assay on the Roche platform makes the test available on demand.
- 10 August 2024
- Published by Oxford University Press (OUP) in Laboratory Medicine
- Vol. 56 (2) , 129-135
Analytical evaluation of the automated interleukin-6 assay on the Roche cobas e602 analyzer
Interleukin-6 (IL-6) is a proinflammatory cytokine that is associated with many inflammatory diseases. This validation study evaluates the automated Roche Elecsys IL-6 electrochemiluminescent immunoassay that has been granted emergency use authorization by the US Food and Drug Administration. The Elecsys IL-6 assay was evaluated for precision, linearity, interference (by hemoglobin, bilirubin, triglycerides, and biotin) and clinical performance was compared to the V-PLEX Human IL-6 immunoassay (Meso Scale Discovery), performed by a reference laboratory. The Elecsys IL-6 assay is precise (intra-assay 2 = 0.84). Bland-Altman analysis revealed an absolute mean bias of 152 pg/mL (SD = 254 pg/mL), or a mean percentage difference of 73%. The Roche IL-6 assay showed good analytical performance. The large systematic bias compared with another reference method precludes using multiple methods to monitor IL-6 response. The random-access nature of an automated IL-6 assay on the Roche platform makes the test available on demand.
- Open Access
- 1 February 2023
- Published by American Diabetes Association in Diabetes Care
- Vol. 46 (4) , 773-776
Insulin Deficiency From Insulin Gene Mutation Leads to Smaller Pancreas
OBJECTIVE: To determine the mechanism of reduced pancreas size in type 1 diabetes and the significance of islet-derived insulin in pancreatic growth.RESEARCH DESIGN AND METHODS: Using a validated and standardized MRI protocol, we measured pancreas volume and shape in a family with an autosomal-dominant insulin gene mutation that results in insulin deficiency similar in severity to that of type 1 diabetes but without autoimmunity. DNA sequencing confirmed the mutation in all four affected individuals and none of the four control family members. Insulin secretory capacity was determined by measuring postprandial urinary C-peptide.RESULTS: Family members with this form of monogenic diabetes had a markedly smaller pancreas and a severely impaired postprandial C-peptide level than family members without diabetes.CONCLUSIONS: These results suggest that severe insulin deficiency, rather than islet-directed autoimmunity, leads to reduced pancreas size in type 1 diabetes and that insulin is a major trophic factor for the exocrine pancreas.
- 1 February 2023
- Published by American Diabetes Association in Diabetes Care
- Vol. 46 (4) , 773-776
Open AccessInsulin Deficiency From Insulin Gene Mutation Leads to Smaller Pancreas
OBJECTIVE: To determine the mechanism of reduced pancreas size in type 1 diabetes and the significance of islet-derived insulin in pancreatic growth.RESEARCH DESIGN AND METHODS: Using a validated and standardized MRI protocol, we measured pancreas volume and shape in a family with an autosomal-dominant insulin gene mutation that results in insulin deficiency similar in severity to that of type 1 diabetes but without autoimmunity. DNA sequencing confirmed the mutation in all four affected individuals and none of the four control family members. Insulin secretory capacity was determined by measuring postprandial urinary C-peptide.RESULTS: Family members with this form of monogenic diabetes had a markedly smaller pancreas and a severely impaired postprandial C-peptide level than family members without diabetes.CONCLUSIONS: These results suggest that severe insulin deficiency, rather than islet-directed autoimmunity, leads to reduced pancreas size in type 1 diabetes and that insulin is a major trophic factor for the exocrine pancreas.
- 22 November 2022
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 159 (1) , 6-9
Use of a Vanadate Oxidation Conjugated Bilirubin Assay to Reduce Test Cancellations Resulting from Hemolyzed Specimens in Pediatric Patients
We sought to replace the highly hemolysis-susceptible diazo conjugated bilirubin (Bc) assay with the more robust vanadate oxidation method and determine its impact on test cancellation in the pediatric population. Analytical validation of the Randox vanadate assay and comparison with the Roche diazo method were performed. The frequency of pediatric sample cancellation because of hemolysis was compared between the diazo and vanadate methods by retrospective analysis of clinical test data. The vanadate assay demonstrated no clinically significant interference from hemolysis up to a hemolysis index of 1,300 (approximately 13 g/L hemoglobin). There was a strong correlation with the diazo method (r2 = 0.97) but with a positive slope bias of 1.27. Implementing the vanadate method resulted in a significantly lower proportion of pediatric samples cancelled because of hemolysis compared with the diazo method (0.6% of 688 patients vs 30.6% of 10,464 patients, respectively; P < .001), with a 0.6% (n = 513) vs 43.2% (n = 6,464) reduction in test cancellations (P < .001) for children younger than 6 months of age. The vanadate method showed robust performance against hemolysis. Its implementation resulted in a significant decrease in pediatric tests cancelled because of hemolysis.
- 22 November 2022
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 159 (1) , 6-9
Use of a Vanadate Oxidation Conjugated Bilirubin Assay to Reduce Test Cancellations Resulting from Hemolyzed Specimens in Pediatric Patients
We sought to replace the highly hemolysis-susceptible diazo conjugated bilirubin (Bc) assay with the more robust vanadate oxidation method and determine its impact on test cancellation in the pediatric population. Analytical validation of the Randox vanadate assay and comparison with the Roche diazo method were performed. The frequency of pediatric sample cancellation because of hemolysis was compared between the diazo and vanadate methods by retrospective analysis of clinical test data. The vanadate assay demonstrated no clinically significant interference from hemolysis up to a hemolysis index of 1,300 (approximately 13 g/L hemoglobin). There was a strong correlation with the diazo method (r2 = 0.97) but with a positive slope bias of 1.27. Implementing the vanadate method resulted in a significantly lower proportion of pediatric samples cancelled because of hemolysis compared with the diazo method (0.6% of 688 patients vs 30.6% of 10,464 patients, respectively; P < .001), with a 0.6% (n = 513) vs 43.2% (n = 6,464) reduction in test cancellations (P < .001) for children younger than 6 months of age. The vanadate method showed robust performance against hemolysis. Its implementation resulted in a significant decrease in pediatric tests cancelled because of hemolysis.
- Top Cited Papers
- 21 July 2021
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 60 (39) , 21116-21149
Recent Advances in Photoredox‐Mediated Radical Conjugate Addition Reactions: An Expanding Toolkit for the Giese Reaction
Photomediated Giese reactions are at the forefront of radical chemistry, much like the classical tin‐mediated Giese reactions were nearly forty years ago. With the global recognition of organometallic photocatalysts for the mild and tunable generation of carbon‐centered radicals, chemists have developed a torrent of strategies to form previously inaccessible radical intermediates that are capable of engaging in intermolecular conjugate addition reactions. This Review summarizes advances in photoredox‐mediated Giese reactions since 2013, with a focus on the breadth of methods that provide access to crucial carbon‐centered radical intermediates that can engage in radical conjugate addition processes.
- 21 July 2021
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 60 (39) , 21116-21149
Top Cited PapersRecent Advances in Photoredox‐Mediated Radical Conjugate Addition Reactions: An Expanding Toolkit for the Giese Reaction
Photomediated Giese reactions are at the forefront of radical chemistry, much like the classical tin‐mediated Giese reactions were nearly forty years ago. With the global recognition of organometallic photocatalysts for the mild and tunable generation of carbon‐centered radicals, chemists have developed a torrent of strategies to form previously inaccessible radical intermediates that are capable of engaging in intermolecular conjugate addition reactions. This Review summarizes advances in photoredox‐mediated Giese reactions since 2013, with a focus on the breadth of methods that provide access to crucial carbon‐centered radical intermediates that can engage in radical conjugate addition processes.
- 24 February 2021
- Published by Wiley in Angewandte Chemie
- Vol. 133 (39) , 21286-21319
Recent Advances in Photoredox‐Mediated Radical Conjugate Addition Reactions: An Expanding Toolkit for the Giese Reaction
Photomediated Giese reactions are at the forefront of radical chemistry, much like the classical tin‐mediated Giese reactions were nearly forty years ago. With the global recognition of organometallic photocatalysts for the mild and tunable generation of carbon‐centered radicals, chemists have developed a torrent of strategies to form previously inaccessible radical intermediates that are capable of engaging in intermolecular conjugate addition reactions. This Review summarizes advances in photoredox‐mediated Giese reactions since 2013, with a focus on the breadth of methods that provide access to crucial carbon‐centered radical intermediates that can engage in radical conjugate addition processes.
- 24 February 2021
- Published by Wiley in Angewandte Chemie
- Vol. 133 (39) , 21286-21319
Recent Advances in Photoredox‐Mediated Radical Conjugate Addition Reactions: An Expanding Toolkit for the Giese Reaction
Photomediated Giese reactions are at the forefront of radical chemistry, much like the classical tin‐mediated Giese reactions were nearly forty years ago. With the global recognition of organometallic photocatalysts for the mild and tunable generation of carbon‐centered radicals, chemists have developed a torrent of strategies to form previously inaccessible radical intermediates that are capable of engaging in intermolecular conjugate addition reactions. This Review summarizes advances in photoredox‐mediated Giese reactions since 2013, with a focus on the breadth of methods that provide access to crucial carbon‐centered radical intermediates that can engage in radical conjugate addition processes.
- Open Access
- 27 January 2021
- Published by SAGE Publications in Therapeutic Advances in Endocrinology and Metabolism
- Vol. 12
The effect of specific binding proteins on immunoassay measurements of total and free thyroid hormones and cortisol
Background: Immunoassay (IA) measurements of thyroid hormones have previously given inaccurate results of triiodothyronine (T3), free triiodothyronine (FT3), and free thyroxine (FT4) when concentrations of TBG are low. We evaluate the hypothesis that abnormal concentrations of specific binding proteins (BPs) affect IA measurements and provide results which might misguide the diagnosis and treatment of patients. This study assesses IAs for the measurement of T3, FT3, and cortisol when levels of TBG and CBG are high or low. Comparisons are made between IA and LC-MS/MS. Methods: Serum or plasma samples with high (>95th percentile, n = 25) or low (n = 27) concentrations of BP were collected. The concentrations of T3, FT3, and cortisol were measured by validated IA and liquid chromatography tandem mass spectrometry (LC-MS/MS) methods. Spearman correlation and Wilcoxon matched-pairs signed rank analyses were used to compare the two methods. Results: When TBG levels are 95th percentile, the difference between the IA and LC-MS/MS measurements of cortisol is statistically significant ( p = <0.0001). Conclusion: Abnormal BP concentrations appear to affect the accuracy of IA measurements of T3, FT3, and cortisol. The population of patients with either high or low levels of BPs is significant. Our samples reflect that 65% of women aged between 15 and 49 years are taking oral contraceptives in the US, and thus have elevated levels of BPs. In this group, IA results for cortisol are falsely low. Our samples reflect that patients with protein losing diseases have low BP concentrations. Among a group with renal complications, IA measurements of T3 are overestimated, while those of FT3 are underestimated. Are the Food and Drug Administration and diagnostic companies adequately assessing the accuracy of IA tests?
- 27 January 2021
- Published by SAGE Publications in Therapeutic Advances in Endocrinology and Metabolism
- Vol. 12
Open AccessThe effect of specific binding proteins on immunoassay measurements of total and free thyroid hormones and cortisol
Background: Immunoassay (IA) measurements of thyroid hormones have previously given inaccurate results of triiodothyronine (T3), free triiodothyronine (FT3), and free thyroxine (FT4) when concentrations of TBG are low. We evaluate the hypothesis that abnormal concentrations of specific binding proteins (BPs) affect IA measurements and provide results which might misguide the diagnosis and treatment of patients. This study assesses IAs for the measurement of T3, FT3, and cortisol when levels of TBG and CBG are high or low. Comparisons are made between IA and LC-MS/MS. Methods: Serum or plasma samples with high (>95th percentile, n = 25) or low (n = 27) concentrations of BP were collected. The concentrations of T3, FT3, and cortisol were measured by validated IA and liquid chromatography tandem mass spectrometry (LC-MS/MS) methods. Spearman correlation and Wilcoxon matched-pairs signed rank analyses were used to compare the two methods. Results: When TBG levels are 95th percentile, the difference between the IA and LC-MS/MS measurements of cortisol is statistically significant ( p = <0.0001). Conclusion: Abnormal BP concentrations appear to affect the accuracy of IA measurements of T3, FT3, and cortisol. The population of patients with either high or low levels of BPs is significant. Our samples reflect that 65% of women aged between 15 and 49 years are taking oral contraceptives in the US, and thus have elevated levels of BPs. In this group, IA results for cortisol are falsely low. Our samples reflect that patients with protein losing diseases have low BP concentrations. Among a group with renal complications, IA measurements of T3 are overestimated, while those of FT3 are underestimated. Are the Food and Drug Administration and diagnostic companies adequately assessing the accuracy of IA tests?
- Open Access
- 21 October 2020
- Published by Bioscientifica in European Journal of Endocrinology
- Vol. 184 (2) , L1-L2
Raising awareness of chronic measurement error intrinsic to immunoassay measurements of small molecule analytes
- 21 October 2020
- Published by Bioscientifica in European Journal of Endocrinology
- Vol. 184 (2) , L1-L2
Open AccessRaising awareness of chronic measurement error intrinsic to immunoassay measurements of small molecule analytes
- Open Access
- 20 April 2020
- Published by American Chemical Society (ACS) in The Journal of Organic Chemistry
- Vol. 85 (10) , 6380-6391
Photochemically Mediated Nickel-Catalyzed Synthesis of N-(Hetero)aryl Sulfamides
A general method for the N-arylation of sulfamides with aryl bromides is described. The protocol leverages a dual-catalytic system, with [Ir(ppy)2(dtbbpy)]PF6 as a photosensitizer, NiBr2·glyme as a precatalyst, and 1,8-diazabicyclo(5.4.0)undec-7-ene (DBU) as a base, and proceeds at room temperature under visible light irradiation. Using these tactics, aryl boronic esters and aryl chlorides can be carried through the reaction untouched. The developed reactions efficiently engage simple bromoarenes and primary sulfamides in between 66% and quantitative yields. For more challenging substrates, such as secondary sulfamides, the reaction efficiency is documented. Thereby, these methods complement the known Buchwald–Hartwig coupling methods for N-arylation of sulfamides.
- 20 April 2020
- Published by American Chemical Society (ACS) in The Journal of Organic Chemistry
- Vol. 85 (10) , 6380-6391
Open AccessPhotochemically Mediated Nickel-Catalyzed Synthesis of N-(Hetero)aryl Sulfamides
A general method for the N-arylation of sulfamides with aryl bromides is described. The protocol leverages a dual-catalytic system, with [Ir(ppy)2(dtbbpy)]PF6 as a photosensitizer, NiBr2·glyme as a precatalyst, and 1,8-diazabicyclo(5.4.0)undec-7-ene (DBU) as a base, and proceeds at room temperature under visible light irradiation. Using these tactics, aryl boronic esters and aryl chlorides can be carried through the reaction untouched. The developed reactions efficiently engage simple bromoarenes and primary sulfamides in between 66% and quantitative yields. For more challenging substrates, such as secondary sulfamides, the reaction efficiency is documented. Thereby, these methods complement the known Buchwald–Hartwig coupling methods for N-arylation of sulfamides.