VDViacheslav Dzhedzhula

Viacheslav Dzhedzhula

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Viacheslav Dzhedzhula has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    МОНІТОРИНГ МІКРОКЛІМАТУ ТА УТОЧНЕННЯ ТЕПЛОВОЇ МОДЕЛІ ГРОМАДСЬКОЇ БУДІВЛІ ЗА РЕЗУЛЬТАТАМИ ВИМІРЮВАНЬ

    by В’яЧеслав Джеджула, Владислав Пацукевич

    The article presents a methodology for refining the thermal model of a public building based on indoor climate monitoring and energy consumption measurements. The relevance of the study stems from the uncertainty of the actual thermal properties of existing buildings and the operating conditions of their heating and ventilation systems, which may lead to substantial discrepancies between calculated and measured energy consumption. The aim is to develop and validate an integrated approach combining on-site measurements, uncertainty quantification, sensitivity analysis, and model calibration. A simplified hourly resistance–capacitance (RC) model using a 3R1C scheme is proposed for simulating the thermal regime of a typical four-storey educational building in Vinnytsia, Ukraine. The uncertainty of nine input parameters is assessed using the Monte Carlo method, while global sensitivity analysis is performed using Sobol indices. The results indicate that the annual space heating demand ranges from 92 to 137 kWh/m² within the 5–95% uncertainty interval. The infiltration air change rate is identified as the dominant parameter, accounting for 64% of the variance in heating demand. Wall thermal transmittance and the indoor temperature setpoint have substantially smaller effects, whereas solar gains and internal heat gains play an important role in determining overheating conditions. The study demonstrates that simultaneous calibration of all influential parameters against heat meter data may produce physically unrealistic parameter estimates due to the compensation of errors. To overcome this limitation, a two-stage calibration procedure is proposed. First, directly measured parameters, including infiltration, ventilation airflow, and indoor temperature, are fixed in the model. The remaining influential parameters are then adjusted through calibration. In a virtual experiment, this approach reduced the monthly normalized mean bias error (NMBE) from 14.5% to 1.0% and reproduced the wall thermal transmittance with an error of 2.6%. The proposed methodology improves the reliability of building energy simulations and provides a basis for substantiated decisions concerning thermal modernization and the optimization of heating and ventilation systems.

  • Open Access

    Agriculture and construction in the new security normality – effects of mutual bioeconomic reconstruction: A review of Nina Petrukha’s monograph

    by Viacheslav Dzhedzhula

    A review of а monograph Petrukha, N. Investment support reconfiguration and resilience formation of agri-enterprises within the bioeconomic paradigm of the new security reality: Methodology, diagnostics, modelling. Kyiv: PH “Akademperiodyka”, 2026

  • Open Access

    INTELLIGENT ENERGY-EFFICIENT MICROCLIMATE CONTROL SYSTEM FOR OPERATING ROOMS IN HEALTHCARE FACILITIES UNDER LIMITED ENERGY SUPPLY

    by Viacheslav Dzhedzhula

    The paper presents the concept and mathematical framework of an intelligent energy-efficient microclimate control system for operating rooms in healthcare facilities under conditions of limited energy supply—an urgent issue for Ukrainian hospitals during wartime, caused by systematic damage to energy infrastructure, rolling blackouts, and the need for uninterrupted operation of critical surgical units. It is substantiated that traditional approaches to controlling heating, ventilation, and air conditioning (HVAC) systems, focused on maintaining fixed parameters around the clock, do not meet modern challenges and require fundamental reconsideration, taking into account the dynamics of the surgical cycle, variable room occupancy, and instability of energy supply. A multi-level system architecture is proposed, which includes: IoT-based monitoring of air environment parameters (temperature, relative humidity, air velocity, CO₂ and PM2.5 concentrations) using a distributed sensor network; a fuzzy controller based on PMV/PPD indices that ensures adaptive control of climatic parameters considering the nonlinearity of heat exchange processes and subjective thermal comfort perception by medical staff; an energy priority manager for operation under limited power conditions with hierarchical ranking of consumers based on clinical criticality; and a multi-criteria optimizer based on the NSGA-II genetic algorithm, which minimizes electricity consumption while ensuring compliance with sanitary and hygienic requirements according to DBN B.2.2-10 and ASHRAE 170, as well as minimizing the risk of surgical site infections (SSI) through control of air exchange rates and aerosol particle concentrations. A mathematical model has been developed that describes the relationship between microclimate parameters, HVAC system energy consumption, and an integrated epidemiological risk indicator, with constraints formalized as membership functions for fuzzy inference. Mathematical modeling and computational experiments based on a real pilot facility in the Vinnytsia region demonstrate that the implementation of the proposed system ensures a reduction in HVAC energy consumption by 38–62% compared to the traditional 24/7 operation mode, while maintaining PMV within ±0.5 for at least 95% of operating time and meeting regulatory requirements for bacterial air contamination. The obtained results have practical significance for the design and modernization of hospital engineering systems in the context of Ukraine’s critical infrastructure recovery.

  • METHODOLOGICAL FUNDAMENTALS OF ENERGY SAVING MANAGEMENT IN HEALTHCARE ENTERPRISES

    by Viacheslav Dzhedzhula, Dmytro Shevchuk

    The paper addresses the methodological foundations for the development and implementation of an energy management system (EnMS) in healthcare facilities. The relevance of this study is determined by the fact that hospital buildings are among the most energy-intensive structures in the public sector, consuming two to three times more energy per unit area compared to conventional commercial buildings. Healthcare facilities operate continuously around the clock and must maintain stringent indoor climate parameters essential for patient safety and recovery, which imposes significant constraints on energy-saving strategies. In the context of rising energy costs, growing environmental concerns, and the ongoing energy crisis in Ukraine, the development of scientifically grounded methodological approaches to energy conservation management in healthcare enterprises is of critical importance.The research methodology integrates several complementary approaches. A regression-based normalization model for heat consumption accounting for climatic factors, specifically heating degree days (HDD), has been developed and validated. This model enables accurate baseline energy performance assessment by decoupling the influence of weather variability from operational and building-related factors, thereby improving the reliability of energy efficiency evaluation. The study also employs a structural-functional modeling approach to design the architecture of the energy management system, incorporating Internet of Things (IoT) technologies for real-time monitoring and data-driven control of heating, ventilation, and air conditioning (HVAC) systems. A comprehensive analysis of key factors affecting energy consumption levels in healthcare buildings has been conducted, including building envelope characteristics, HVAC system configurations, occupancy patterns, medical equipment loads, and operational schedules.The results demonstrate that the proposed integrated approach enables a systematic identification of energy-saving opportunities while preserving the required microclimate conditions in medical premises. The structural-functional model of the energy management system defines the interaction between monitoring, analysis, decision-making, and control subsystems, providing a framework for continuous energy performance improvement. The key influencing factors have been ranked and their incorporation into managerial decision-making processes has been formalized. Practical recommendations for EnMS implementation have been developed, taking into account the specific operational requirements of healthcare buildings, including the need for uninterrupted climate control in critical areas such as operating theatres, intensive care units, and sterile zones.The verification of the proposed methodology was performed using a medical center located in Vinnytsia, Ukraine, as a pilot facility. The implementation results confirm the effectiveness of the approach: the specific heat consumption was reduced by 29.4%, while the Net Present Value (NPV) over a 10-year period amounts to +18.4 million UAH, demonstrating both the energy and economic viability of the proposed system. The findings contribute to the scientific basis for energy-efficient microclimate management in healthcare facilities and can be applied to similar institutions across Ukraine and other countries with comparable climatic and institutional conditions.

  • Open Access

    ІННОВАЦІЙНІ НАПРЯМИ ЕНЕРГОЗБЕРЕЖЕННЯ ПІДПРИЄМСТВ ОХОРОНИ ЗДОРОВ'Я

    by В’яЧеслав Джеджула, Дмитро Шевчук

    The article is devoted to the study of innovative directions of energy conservation in healthcare facilities. Modern technological solutions are considered, including the implementation of LED lighting, heat pumps, heat recovery systems, solar photovoltaic panels, and intelligent building management systems (BMS). An economic-mathematical model for determining savings from the implementation of a comprehensive set of energy conservation measures is proposed, which allows for the evaluation of net present value (NPV), internal rate of return (IRR), and investment payback period. Based on the modelling, it is demonstrated that the comprehensive implementation of innovative energy conservation measures ensures a reduction in facility energy consumption by 28–40% with an investment payback period of 3.5–5.5 years.

  • The Strategic Potential of Renewable Energy Microgrids: Global Transformations and Determinants of Sustainable Development

    by Volodymyr Lypov, Natalya Ushenko, Viktoriia Hurochkina, Tomasz Szapiro, Larysa Shaulska, Viacheslav Dzhedzhula

  • Impact of Energy-Saving Technological Changes on the Level of Competitiveness of Enterprises

    by Olexandr Yemelyanov, Tetyana Petrushka, Orest Koleshchuk, Kateryna Petrushka, Viacheslav Dzhedzhula


  • Open Access

    MATHEMATICAL MODELING AND OPTIMIZATION OF ENERGY CONSUMPTION OF VENTILATION SYSTEMS IN PUBLIC CATERING FACILITIES

    by В’ячеслав Васильович Джеджула, Maksym Riabchynskyi, Mykhailo Chuhu, Максим Олександрович Рябчинський, Михайло Анатолійович Чугу

    In this work, an analysis of modern approaches to optimizing the energy consumption of ventilation systems in publiccatering facilities is carried out. Regulatory requirements for air quality and microclimate parameters are considered, inparticular the permissible levels of CO₂ concentration and temperature. Based on the analysis, it was found that traditionalsystems with constant air supply have increased energy costs and do not always ensure optimal conditions. A mathematicalmodel is proposed that describes the energy consumption of the ventilation system, as well as the changes in CO₂concentration and indoor temperature depending on the ventilation operating mode. Two scenarios are implemented: constantair supply and optimized variable supply regulated according to the load. The calculations were performed in the MATLABenvironment, and the results were visualized in the form of graphs indicating regulatory limits and key points. The simulationshowed that the optimized mode allows for a significant reduction in energy consumption while maintaining comfortableconditions. A quantitative comparison of energy costs for both modes was carried out, confirming the effectiveness of theapproach. The results of the work can be used to modernize ventilation systems in public catering facilities. The proposedmethod can also be adapted for other types of public buildings.

  • Open Access

    RESEARCH ON HEAT TRANSFER MECHANISM AND THERMAL PERFORMANCE OF WHEAT STRAW FLY ASH CONCRETE

    by В’ячеслав Васильович Джеджула, Guo Zhiyong, Го Чжионг

    A large number of rural residential buildings in the world did not take effective thermal insulation measures. The poorthermal insulation performance of the envelope led to low indoor temperatures in winter, and energy consumption was huge.The purpose of this study was to explore the effect of wheat straw and fly ash incorporated into concrete on its thermalproperties, and to provide a low-cost and energy-efficient solution for rural building wall materials. The experiment involvedpreparing concrete block samples containing different doses of fly ash and straw, building an experimental platform todetermine compressive strength and thermal conductivity, and simulating different humid environments using a saturatedsaline solution to analyse the effect of moisture content on thermal conductivity. The effect of moisture content on thermalconductivity was analysed by simulating different humidity environments with saturated salt solution. Combined with data fittingand comparative analysis, the mechanism of straw admixture, morphology and humidity on the material properties wasrevealed. The study showed that the thermal conductivity of wheat straw fly ash concrete decreased gradually as the contentof fly ash and straw increased, and the larger the content, the smaller the thermal conductivity. The thermal conductivity ofwheat straw fly ash concrete increased significantly with the increase in air humidity, and the relationship between moisturecontent and thermal conductivity was closely related to the content of straw and fly ash. The incorporation of fly ash and strawin concrete effectively improved the thermal insulation performance of building materials, and was an effective alternative forimproving building energy efficiency and reducing carbon emissions