Hideo Kawabata
Research Subjects
Hideo Kawabata has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Kazushige Isobe
Tokyo Plastic Dental Society, Kita-ku, Tokyo 114-0002, Japan
6 shared publications - Taisuke Watanabe
Tokyo Plastic Dental Society, Kita-ku, Tokyo 114-0002, Japan
6 shared publications - Tomoyuki Kawase
Division of Oral Bioengineering, Institute of Medicine and Dentistry, Niigata University, Niigata 951-8514, Japan
6 shared publications - Koh Nakata
Bioscience Medical Research Center, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
5 shared publications - Hachidai Aizawa
Tokyo Plastic Dental Society, Kita-ku, Tokyo 114-0002, Japan
4 shared publications - Hajime Okudera
Tokyo Plastic Dental Society, Kita-ku, Tokyo 114-0002, Japan
4 shared publications
Latest Publications
- Open Access
- 6 July 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (14) , 7257
Fluorometric Quantification of Human Platelet Polyphosphate Using 4′,6-Diamidine-2-phenylindole Dihydrochloride: Applications in the Japanese Population
Polyphosphate (polyP), a biopolymer of inorganic phosphate, is widely distributed in living organisms. In platelets, polyP is released upon activation and plays important roles in coagulation and tissue regeneration. However, the lack of a specific quantification method has delayed the in-depth study of polyP. The fluorescent dye 4′,6-diamidine-2-phenylindole dihydrochloride (DAPI) has recently received attention as a promising probe for the visualization and quantification of cellular polyP levels. In this study, we further optimized quantification conditions and applied this protocol in quantification of platelet polyP levels in a Japanese population. Blood samples were collected from non-smoking, healthy Japanese subjects (23 males, 23 females). Washed platelets were fixed and probed with DAPI for fluorometric determination. PolyP levels per platelet count were significantly higher in women than that in men. A moderate negative correlation between age and polyP levels was found in women. Responsiveness to CaCl2 stimulation was also significantly higher in women than that in men. Overall, our optimized protocol requires neither purification nor degradation steps, reducing both the time and bias for reproducible quantification. Thus, we suggest that despite its low specificity, this DAPI-based protocol would be useful in routine laboratory testing to quantify platelet polyP levels efficiently and economically.
- 6 July 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (14) , 7257
Open AccessFluorometric Quantification of Human Platelet Polyphosphate Using 4′,6-Diamidine-2-phenylindole Dihydrochloride: Applications in the Japanese Population
Polyphosphate (polyP), a biopolymer of inorganic phosphate, is widely distributed in living organisms. In platelets, polyP is released upon activation and plays important roles in coagulation and tissue regeneration. However, the lack of a specific quantification method has delayed the in-depth study of polyP. The fluorescent dye 4′,6-diamidine-2-phenylindole dihydrochloride (DAPI) has recently received attention as a promising probe for the visualization and quantification of cellular polyP levels. In this study, we further optimized quantification conditions and applied this protocol in quantification of platelet polyP levels in a Japanese population. Blood samples were collected from non-smoking, healthy Japanese subjects (23 males, 23 females). Washed platelets were fixed and probed with DAPI for fluorometric determination. PolyP levels per platelet count were significantly higher in women than that in men. A moderate negative correlation between age and polyP levels was found in women. Responsiveness to CaCl2 stimulation was also significantly higher in women than that in men. Overall, our optimized protocol requires neither purification nor degradation steps, reducing both the time and bias for reproducible quantification. Thus, we suggest that despite its low specificity, this DAPI-based protocol would be useful in routine laboratory testing to quantify platelet polyP levels efficiently and economically.
- Open Access
- 25 February 2020
- Published by MDPI AG in Biomedicines
- Vol. 8 (3) , 42
A Comparative Study of the Effects of Anticoagulants on Pure Platelet-Rich Plasma Quality and Potency
It is generally accepted that citrate or the A-form of acid-citrate-dextrose (ACD-A) are suitable for preparing platelet-rich plasma (PRP) for regenerative therapy. However, this is based on evidence from blood transfusions and not from regenerative medicine. Thus, we examined the effects of anticoagulants, such as ACD-A, ethylenediaminetetraacetic acid (EDTA), and heparin, on the regenerative quality of PRP to address this gap. The blood samples were collected in the presence of anticoagulants and were processed to prepare pure-PRP. Platelet size, activation status, and intra-platelet free Ca2+ concentration were determined while using a hematology analyzer and flow cytometer. Platelet-derived growth factor-BB (PDGF-BB) was quantified while using an ELISA. In pure-PRP samples, EDTA caused platelet swelling and activation, but yielded the highest number of platelets. Heparin aggregated platelets and disturbed the overall counting of blood cells. However, no significant differences in PDGF-BB levels were observed among the anticoagulants tested. Moreover, when considering the easy preparation of platelet suspensions, without the need for high-level pipetting skills, these findings suggest the comparable potency of EDTA-derived pure-PRP in tissue regeneration and support the use of EDTA in the preparation of pure-PRP. Further in vivo studies are required in animal models to exclude the possible negative effects of including EDTA in pure-PRP preparations.
- 25 February 2020
- Published by MDPI AG in Biomedicines
- Vol. 8 (3) , 42
Open AccessA Comparative Study of the Effects of Anticoagulants on Pure Platelet-Rich Plasma Quality and Potency
It is generally accepted that citrate or the A-form of acid-citrate-dextrose (ACD-A) are suitable for preparing platelet-rich plasma (PRP) for regenerative therapy. However, this is based on evidence from blood transfusions and not from regenerative medicine. Thus, we examined the effects of anticoagulants, such as ACD-A, ethylenediaminetetraacetic acid (EDTA), and heparin, on the regenerative quality of PRP to address this gap. The blood samples were collected in the presence of anticoagulants and were processed to prepare pure-PRP. Platelet size, activation status, and intra-platelet free Ca2+ concentration were determined while using a hematology analyzer and flow cytometer. Platelet-derived growth factor-BB (PDGF-BB) was quantified while using an ELISA. In pure-PRP samples, EDTA caused platelet swelling and activation, but yielded the highest number of platelets. Heparin aggregated platelets and disturbed the overall counting of blood cells. However, no significant differences in PDGF-BB levels were observed among the anticoagulants tested. Moreover, when considering the easy preparation of platelet suspensions, without the need for high-level pipetting skills, these findings suggest the comparable potency of EDTA-derived pure-PRP in tissue regeneration and support the use of EDTA in the preparation of pure-PRP. Further in vivo studies are required in animal models to exclude the possible negative effects of including EDTA in pure-PRP preparations.
- Open Access
- 17 September 2019
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 10 (3) , 43
Striking Differences in Platelet Distribution between Advanced-Platelet-Rich Fibrin and Concentrated Growth Factors: Effects of Silica-Containing Plastic Tubes
Compared with platelet-rich plasma, the preparation of platelet-rich fibrin (PRF) is simple and has not been overly modified. However, it was recently demonstrated that centrifugation conditions influence the composition of PRF and that silica microparticles from silica-coated plastic tubes can enter the PRF matrix. These factors may also modify platelet distribution. To examine these possibilities, we prepared PRF matrices using various types of blood-collection tubes (plain glass tubes and silica-containing plastic tubes) and different centrifugation speeds. The protocols of concentrated growth factors and advanced-PRF represented high- and low-speed centrifugation, respectively. Platelet distribution in the PRF matrix was examined immunohistochemically. Using low-speed centrifugation, platelets were distributed homogeneously within the PRF matrix regardless of tube types. In high-speed centrifugation, platelets were distributed mainly on one surface region of the PRF matrix in glass tubes, whereas in silica-coated tubes, platelet distribution was commonly more diffusive than in glass tubes. Therefore, both blood-collection tube types and centrifugal conditions appeared to influence platelet distribution in the PRF matrix. Platelets distributed in the deep regions of the PRF matrix may contribute to better growth factor retention and release. However, clinicians should be careful in using silica-coated tubes because their silica microparticles may be a health hazard.
- 17 September 2019
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 10 (3) , 43
Open AccessStriking Differences in Platelet Distribution between Advanced-Platelet-Rich Fibrin and Concentrated Growth Factors: Effects of Silica-Containing Plastic Tubes
Compared with platelet-rich plasma, the preparation of platelet-rich fibrin (PRF) is simple and has not been overly modified. However, it was recently demonstrated that centrifugation conditions influence the composition of PRF and that silica microparticles from silica-coated plastic tubes can enter the PRF matrix. These factors may also modify platelet distribution. To examine these possibilities, we prepared PRF matrices using various types of blood-collection tubes (plain glass tubes and silica-containing plastic tubes) and different centrifugation speeds. The protocols of concentrated growth factors and advanced-PRF represented high- and low-speed centrifugation, respectively. Platelet distribution in the PRF matrix was examined immunohistochemically. Using low-speed centrifugation, platelets were distributed homogeneously within the PRF matrix regardless of tube types. In high-speed centrifugation, platelets were distributed mainly on one surface region of the PRF matrix in glass tubes, whereas in silica-coated tubes, platelet distribution was commonly more diffusive than in glass tubes. Therefore, both blood-collection tube types and centrifugal conditions appeared to influence platelet distribution in the PRF matrix. Platelets distributed in the deep regions of the PRF matrix may contribute to better growth factor retention and release. However, clinicians should be careful in using silica-coated tubes because their silica microparticles may be a health hazard.
- Open Access
- 3 June 2019
- Published by MDPI AG in Dentistry Journal
- Vol. 7 (2) , 61
Spectrophotometric Determination of the Aggregation Activity of Platelets in Platelet-Rich Plasma for Better Quality Control
Although platelet-rich plasma (PRP) is now widely used in regenerative medicine and dentistry, contradictory clinical outcomes have often been obtained. To minimize such differences and to obtain high quality evidence from clinical studies, the PRP preparation protocol needs to be standardized. In addition, emphasis must be placed on quality control. Following our previous spectrophotometric method of platelet counting, in this study, another simple and convenient spectrophotometric method to determine platelet aggregation activity has been developed. Citrated blood samples were collected from healthy donors and used. After centrifugation twice, platelets were suspended in phosphate buffered saline (PBS) and adenosine diphosphate (ADP)-induced aggregation was determined using a spectrophotometer at 615 nm. For validation, platelets pretreated with aspirin, an antiplatelet agent, or hydrogen peroxide (H2O2), an oxidative stress-inducing agent, were also analyzed. Optimal platelet concentration, assay buffer solution, and representative time point for determination of aggregation were found to be 50–100 × 104/μL, PBS, and 3 min after stimulation, respectively. Suppressed or injured platelets showed a significantly lower aggregation response to ADP. Therefore, it suggests that this spectrophotometric method may be useful in quick chair-side evaluation of individual PRP quality.
- 3 June 2019
- Published by MDPI AG in Dentistry Journal
- Vol. 7 (2) , 61
Open AccessSpectrophotometric Determination of the Aggregation Activity of Platelets in Platelet-Rich Plasma for Better Quality Control
Although platelet-rich plasma (PRP) is now widely used in regenerative medicine and dentistry, contradictory clinical outcomes have often been obtained. To minimize such differences and to obtain high quality evidence from clinical studies, the PRP preparation protocol needs to be standardized. In addition, emphasis must be placed on quality control. Following our previous spectrophotometric method of platelet counting, in this study, another simple and convenient spectrophotometric method to determine platelet aggregation activity has been developed. Citrated blood samples were collected from healthy donors and used. After centrifugation twice, platelets were suspended in phosphate buffered saline (PBS) and adenosine diphosphate (ADP)-induced aggregation was determined using a spectrophotometer at 615 nm. For validation, platelets pretreated with aspirin, an antiplatelet agent, or hydrogen peroxide (H2O2), an oxidative stress-inducing agent, were also analyzed. Optimal platelet concentration, assay buffer solution, and representative time point for determination of aggregation were found to be 50–100 × 104/μL, PBS, and 3 min after stimulation, respectively. Suppressed or injured platelets showed a significantly lower aggregation response to ADP. Therefore, it suggests that this spectrophotometric method may be useful in quick chair-side evaluation of individual PRP quality.
- Open Access
- 18 September 2017
- Published by MDPI AG in Biomedicines
- Vol. 5 (3) , 57
Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage
The platelet-rich fibrin–like matrix (PRFM) is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB) samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl2 in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB) levels were examined by scanning electron microscopy (SEM), flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA), respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method.
- 18 September 2017
- Published by MDPI AG in Biomedicines
- Vol. 5 (3) , 57
Open AccessQuality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage
The platelet-rich fibrin–like matrix (PRFM) is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB) samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl2 in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB) levels were examined by scanning electron microscopy (SEM), flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA), respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method.
- Open Access
- 12 January 2017
- Published by MDPI AG in Dentistry Journal
- Vol. 5 (1) , 7
An Evaluation of the Accuracy of the Subtraction Method Used for Determining Platelet Counts in Advanced Platelet-Rich Fibrin and Concentrated Growth Factor Preparations
Platelet concentrates should be quality-assured of purity and identity prior to clinical use. Unlike for the liquid form of platelet-rich plasma, platelet counts cannot be directly determined in solid fibrin clots and are instead calculated by subtracting the counts in other liquid or semi-clotted fractions from those in whole blood samples. Having long suspected the validity of this method, we herein examined the possible loss of platelets in the preparation process. Blood samples collected from healthy male donors were immediately centrifuged for advanced platelet-rich fibrin (A-PRF) and concentrated growth factors (CGF) according to recommended centrifugal protocols. Blood cells in liquid and semi-clotted fractions were directly counted. Platelets aggregated on clot surfaces were observed by scanning electron microscopy. A higher centrifugal force increased the numbers of platelets and platelet aggregates in the liquid red blood cell fraction and the semi-clotted red thrombus in the presence and absence of the anticoagulant, respectively. Nevertheless, the calculated platelet counts in A-PRF/CGF preparations were much higher than expected, rendering the currently accepted subtraction method inaccurate for determining platelet counts in fibrin clots. To ensure the quality of solid types of platelet concentrates chairside in a timely manner, a simple and accurate platelet-counting method should be developed immediately.
- 12 January 2017
- Published by MDPI AG in Dentistry Journal
- Vol. 5 (1) , 7
Open AccessAn Evaluation of the Accuracy of the Subtraction Method Used for Determining Platelet Counts in Advanced Platelet-Rich Fibrin and Concentrated Growth Factor Preparations
Platelet concentrates should be quality-assured of purity and identity prior to clinical use. Unlike for the liquid form of platelet-rich plasma, platelet counts cannot be directly determined in solid fibrin clots and are instead calculated by subtracting the counts in other liquid or semi-clotted fractions from those in whole blood samples. Having long suspected the validity of this method, we herein examined the possible loss of platelets in the preparation process. Blood samples collected from healthy male donors were immediately centrifuged for advanced platelet-rich fibrin (A-PRF) and concentrated growth factors (CGF) according to recommended centrifugal protocols. Blood cells in liquid and semi-clotted fractions were directly counted. Platelets aggregated on clot surfaces were observed by scanning electron microscopy. A higher centrifugal force increased the numbers of platelets and platelet aggregates in the liquid red blood cell fraction and the semi-clotted red thrombus in the presence and absence of the anticoagulant, respectively. Nevertheless, the calculated platelet counts in A-PRF/CGF preparations were much higher than expected, rendering the currently accepted subtraction method inaccurate for determining platelet counts in fibrin clots. To ensure the quality of solid types of platelet concentrates chairside in a timely manner, a simple and accurate platelet-counting method should be developed immediately.