Denise Pontes Raldi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Denise Pontes Raldi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- José Luiz Lage-Marques
University of Taubate
4 shared publications Erica dos Santos Carvalho
Division of Endodontics, Department of Dentistry, Federal University of Bahia, Salvador, Bahia, Brazil
3 shared publicationsIsabel Mello
Division of Endodontics, Department of Dental Clinical Sciences, Dalhousie University, Halifax, NS, Canada
3 shared publicationsSandra Márcia Habitante
Department of Dentistry, University of Taubaté, Taubaté, São Paulo
3 shared publicationsAna Christina Claro Neves
Department of Dentistry, University of Taubaté, Taubaté, São Paulo
2 shared publicationsSandra Marcia Habitante
Department of Dentistry, University of Taubaté, Taubaté, São Paulo, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 February 2021
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 32 (1) , 53-58
Tooth Discoloration Using Calcium Silicate-Based Cements For Simulated Revascularization in Vitro
The endodontic revascularization may be an alternative treatment for necrotic immature teeth, however, several treatment steps may cause tooth discoloration. This study evaluated the use of three calcium silicate-based cements with different radiopacifying agents on the color alteration (∆E) of extracted premolars after simulation of revascularization. Forty single rooted extracted premolars were shaped with #1-6 gates Glidden drills, rinsed with sodium hypochlorite, and filled with fresh human blood. Three calcium silicate-based cements with different radiopacifying agents (bismuth oxide - CSBi, calcium tungstate - CSW, and zirconium oxide - CSZr) were applied over the blood clot (n=10). The control group received the application of a temporary zinc oxide-based cement (TFZn) (n=10). ∆E was measured with a spectrophotometer, using the L*a*b* color system of the International Commission on Illumination (CIELab), in different times: prior to the preparation of the access cavity (t0); right after treatment (t1); and after one (t2), two (t3), three (t4) and four (t5) months. The tooth site for color evaluation was standardized by silicon matrix, the color reading was performed 3 times per tooth, and the teeth were stored in 37º water between evaluations. ∆E, whiteness (WID index) and yellowness (b*) were evaluated. Data were subjected to one-way ANOVA and repeated measures ANOVA, followed by Tukey’s post hoc test (α=0.05). All groups were similar in ∆E1 (t0-t1). The ∆E was the lowest and constant in the control group. In all evaluation times, CSBi presented the highest ∆E (p<0.01). CSW and CSZr were similar in all evaluated times and presented intermediate ∆E values. WID index from CSBi and CSW presented more distancing from ‘white’ reference. CSBi presented the greatest decrease in yellowness (b* value). The cement containing bismuth oxide presented the highest color alteration values. All tested calcium silicate-based cements presented clinically perceptible discoloration. Calcium tungstate and zirconium oxide may be used as alternative radiopacifiers to decrease tooth discoloration after endodontic tooth revascularization.
- 1 February 2021
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 32 (1) , 53-58
Open AccessTooth Discoloration Using Calcium Silicate-Based Cements For Simulated Revascularization in Vitro
The endodontic revascularization may be an alternative treatment for necrotic immature teeth, however, several treatment steps may cause tooth discoloration. This study evaluated the use of three calcium silicate-based cements with different radiopacifying agents on the color alteration (∆E) of extracted premolars after simulation of revascularization. Forty single rooted extracted premolars were shaped with #1-6 gates Glidden drills, rinsed with sodium hypochlorite, and filled with fresh human blood. Three calcium silicate-based cements with different radiopacifying agents (bismuth oxide - CSBi, calcium tungstate - CSW, and zirconium oxide - CSZr) were applied over the blood clot (n=10). The control group received the application of a temporary zinc oxide-based cement (TFZn) (n=10). ∆E was measured with a spectrophotometer, using the L*a*b* color system of the International Commission on Illumination (CIELab), in different times: prior to the preparation of the access cavity (t0); right after treatment (t1); and after one (t2), two (t3), three (t4) and four (t5) months. The tooth site for color evaluation was standardized by silicon matrix, the color reading was performed 3 times per tooth, and the teeth were stored in 37º water between evaluations. ∆E, whiteness (WID index) and yellowness (b*) were evaluated. Data were subjected to one-way ANOVA and repeated measures ANOVA, followed by Tukey’s post hoc test (α=0.05). All groups were similar in ∆E1 (t0-t1). The ∆E was the lowest and constant in the control group. In all evaluation times, CSBi presented the highest ∆E (p<0.01). CSW and CSZr were similar in all evaluated times and presented intermediate ∆E values. WID index from CSBi and CSW presented more distancing from ‘white’ reference. CSBi presented the greatest decrease in yellowness (b* value). The cement containing bismuth oxide presented the highest color alteration values. All tested calcium silicate-based cements presented clinically perceptible discoloration. Calcium tungstate and zirconium oxide may be used as alternative radiopacifiers to decrease tooth discoloration after endodontic tooth revascularization.
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Efeitos do laser de diodo de alta potência e da fotobiomodulação em dentes de ratos reimplantados tardiamente
Resumo Introdução A busca por protocolos efetivos para reduzir a incidência de reabsorções radiculares e favorecer a reparação do ligamento periodontal perdido ainda representa um grande desafio, tendo em vista o prognóstico desfavorável dos reimplantes dentais tardios. Objetivo Avaliar, por meio da análise histológica, os efeitos do laser de alta potência e da fotobiomodulação na ocorrência de reabsorção radicular e no reparo periodontal, em dentes reimplantados tardiamente. Material e método Foram utilizados 50 incisivos centrais direitos de ratos Wistar. Após a extração, os espécimes foram divididos em cinco grupos (n = 10): G1 (controle positivo): reimplante imediato; G2 (controle negativo): reimplante tardio (RT): espécimes mantidos em ambiente seco por 60 minutos, sem tratamento adicional; G3: RT associado ao tratamento da superfície radicular com laser diodo de alta potência (810 nm, 1.5 W); G4: RT + superfícies radiculares e feridas alveolares tratadas com fotobiomodulação (laser diodo 660 nm, 30 mW e 780 nm, 40 mW, respectivamente); G5: RT + superfícies radiculares irradiadas com laser de alta e alvéolos com fotobiomodulação, nos mesmos parâmetros que G3 e G4, respectivamente. Após 60 dias, os animais foram eutanasiados. Os espécimes foram processados para análise histológica. Resultado G3 e G5 apresentaram as menores médias de scores com relação à ocorrência de reabsorções radiculares e anquilose, quando comparados a G2 e G4 (Teste Kruskall-Wallis, p<0,05). Com relação ao reparo periodontal, todos os grupos experimentais (G3, G4 e G5) apresentaram médias de escores inferiores (Teste Kruskall-Wallis, p0,05). Conclusão O laser de alta potência, associado ou não à fotobiomodulação, diminuiu a ocorrência das reabsorções radiculares e da anquilose, e a fotobiomodulação não favoreceu o controle das reabsorções radiculares nem o reparo periodontal.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Open AccessEfeitos do laser de diodo de alta potência e da fotobiomodulação em dentes de ratos reimplantados tardiamente
Resumo Introdução A busca por protocolos efetivos para reduzir a incidência de reabsorções radiculares e favorecer a reparação do ligamento periodontal perdido ainda representa um grande desafio, tendo em vista o prognóstico desfavorável dos reimplantes dentais tardios. Objetivo Avaliar, por meio da análise histológica, os efeitos do laser de alta potência e da fotobiomodulação na ocorrência de reabsorção radicular e no reparo periodontal, em dentes reimplantados tardiamente. Material e método Foram utilizados 50 incisivos centrais direitos de ratos Wistar. Após a extração, os espécimes foram divididos em cinco grupos (n = 10): G1 (controle positivo): reimplante imediato; G2 (controle negativo): reimplante tardio (RT): espécimes mantidos em ambiente seco por 60 minutos, sem tratamento adicional; G3: RT associado ao tratamento da superfície radicular com laser diodo de alta potência (810 nm, 1.5 W); G4: RT + superfícies radiculares e feridas alveolares tratadas com fotobiomodulação (laser diodo 660 nm, 30 mW e 780 nm, 40 mW, respectivamente); G5: RT + superfícies radiculares irradiadas com laser de alta e alvéolos com fotobiomodulação, nos mesmos parâmetros que G3 e G4, respectivamente. Após 60 dias, os animais foram eutanasiados. Os espécimes foram processados para análise histológica. Resultado G3 e G5 apresentaram as menores médias de scores com relação à ocorrência de reabsorções radiculares e anquilose, quando comparados a G2 e G4 (Teste Kruskall-Wallis, p<0,05). Com relação ao reparo periodontal, todos os grupos experimentais (G3, G4 e G5) apresentaram médias de escores inferiores (Teste Kruskall-Wallis, p0,05). Conclusão O laser de alta potência, associado ou não à fotobiomodulação, diminuiu a ocorrência das reabsorções radiculares e da anquilose, e a fotobiomodulação não favoreceu o controle das reabsorções radiculares nem o reparo periodontal.
- Open Access
- 1 June 2017
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 18 (6) , 448-451
Radiopacity of Mineral Trioxide Aggregate with and without Inclusion of Silver Nanoparticles
Aim: The aim of this study was to investigate the inclusion of silver nanoparticles (Ag NPs) in the mineral trioxide aggregate (MTA) composition to know which changes will result in the radiopacity of the material.Materials and methods: The experiment was performed according to the American National Standard Institute/American Dental Association specification no. 57/2000 and ISO 6876/2001. Five plates with five holes measuring 1 mm in depth and 5 mm in internal diameter were filled according to the different experimental groups as follows: white mineral trioxide aggregate (WMTA) + NP50 – W MTA with liquid Ag NP 50 ppm, WMTA + NP30 – W MTA with liquid Ag NP 30 ppm, WMTA + NP22 – W MTA with liquid Ag NP 22 ppm, WMTA + NPP – white MTA with liquid Ag NP and powder 1%, WMTA (control). After filling the plates, they were kept in an incubator at 37°C in relative humidity for setting. Each sample was positioned along an aluminum step-wedge placed above the Opteo digital sensor system. The image was divided into four quadrants, and three readings were made for each quadrant to render the average of each quadrant. The resulting data were submitted to Kruskal–Wallis and Dunn's tests.Results: The results showed statistically significant differences between WMTA + NP30, WMTA + NP22, and WMTA + NPP interactions compared with WMTA (control) (p < 0.05). The radiopacity was in descending order: WMTA + NPP, WMTA + NP22, WMTA + NP30, MTA + NP50, and WMTA.Conclusion: Silver NPs changed the radiopacity of WMTA, being more evident in WMTA + NP powder at 1% weight.Clinical significance: The low radiopacity of MTA makes it difficult for any radiographic observation. The Ag NPs appear as an alternative, being an excellent radiopacifier as they have excellent antimicrobial property and relatively low toxicity.How to cite this article: Mendes MSS, Resende LD, Pinto CA, Raldi DP, Cardoso FGR, Habitante SM. Radiopacity of Mineral Trioxide Aggregate with and without Inclusion of Silver Nanoparticles. J Contemp Dent Pract 2017;18(6):448-451.
- 1 June 2017
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 18 (6) , 448-451
Open AccessRadiopacity of Mineral Trioxide Aggregate with and without Inclusion of Silver Nanoparticles
Aim: The aim of this study was to investigate the inclusion of silver nanoparticles (Ag NPs) in the mineral trioxide aggregate (MTA) composition to know which changes will result in the radiopacity of the material.Materials and methods: The experiment was performed according to the American National Standard Institute/American Dental Association specification no. 57/2000 and ISO 6876/2001. Five plates with five holes measuring 1 mm in depth and 5 mm in internal diameter were filled according to the different experimental groups as follows: white mineral trioxide aggregate (WMTA) + NP50 – W MTA with liquid Ag NP 50 ppm, WMTA + NP30 – W MTA with liquid Ag NP 30 ppm, WMTA + NP22 – W MTA with liquid Ag NP 22 ppm, WMTA + NPP – white MTA with liquid Ag NP and powder 1%, WMTA (control). After filling the plates, they were kept in an incubator at 37°C in relative humidity for setting. Each sample was positioned along an aluminum step-wedge placed above the Opteo digital sensor system. The image was divided into four quadrants, and three readings were made for each quadrant to render the average of each quadrant. The resulting data were submitted to Kruskal–Wallis and Dunn's tests.Results: The results showed statistically significant differences between WMTA + NP30, WMTA + NP22, and WMTA + NPP interactions compared with WMTA (control) (p < 0.05). The radiopacity was in descending order: WMTA + NPP, WMTA + NP22, WMTA + NP30, MTA + NP50, and WMTA.Conclusion: Silver NPs changed the radiopacity of WMTA, being more evident in WMTA + NP powder at 1% weight.Clinical significance: The low radiopacity of MTA makes it difficult for any radiographic observation. The Ag NPs appear as an alternative, being an excellent radiopacifier as they have excellent antimicrobial property and relatively low toxicity.How to cite this article: Mendes MSS, Resende LD, Pinto CA, Raldi DP, Cardoso FGR, Habitante SM. Radiopacity of Mineral Trioxide Aggregate with and without Inclusion of Silver Nanoparticles. J Contemp Dent Pract 2017;18(6):448-451.
- 25 November 2016
- Published by Wiley in Dental Traumatology
- Vol. 33 (2) , 91-99
Effects of diode laser irradiation and fibroblast growth factor on periodontal healing of replanted teeth after extended extra‐oral dry time
The search for effective protocols to reduce the incidence of root resorption and allow periodontal ligament repair is still challenging, given the unpredictable outcome of late tooth replantation. The aim of this study was to assess the effects of both high-power diode laser irradiation (DL) and basic fibroblast growth factor (FGF) on the periodontal healing of replanted teeth after extended extra-oral dry time. Maxillary incisors of 50 male rats were extracted and assigned to three experimental and two control groups (n = 10). DL: root surfaces treated with DL (810 nm, continuous mode, 1.0 W, 30 s), FGF: topical application of FGF gel to the root surface and in the alveolar wound, DL + FGF: DL and topical application of FGF gel, C+: no treatment after extraction and immediate replantation and C−: no treatment after extraction and replantation after 60 min. In the experimental groups, the specimens were kept dry for 60 min, the pulps were removed and the canals were filled with calcium hydroxide paste prior to tooth replantation. The animals were euthanized after 60 days. The specimens were processed for radiographic, histological and immunohistochemical analyses. The radiographic analysis showed fewer resorptive areas in DL + FGF (P < 0.05). The histological and immunohistochemical analyses showed that the DL group had lower mean values of ankylosis, replacement and inflammatory resorption when compared to C−, not differing statistically from C+. DL + FGF produced significantly more collagen fibers (type I and type III) than C−, not differing from C+ in the case of type I fibers (P < 0.05). DL, with or without FGF, reduced the occurrence of external root resorption and ankylosis. Periodontal healing was favored and some fiber reinsertion occurred only when FGF was used.
- 25 November 2016
- Published by Wiley in Dental Traumatology
- Vol. 33 (2) , 91-99
Effects of diode laser irradiation and fibroblast growth factor on periodontal healing of replanted teeth after extended extra‐oral dry time
The search for effective protocols to reduce the incidence of root resorption and allow periodontal ligament repair is still challenging, given the unpredictable outcome of late tooth replantation. The aim of this study was to assess the effects of both high-power diode laser irradiation (DL) and basic fibroblast growth factor (FGF) on the periodontal healing of replanted teeth after extended extra-oral dry time. Maxillary incisors of 50 male rats were extracted and assigned to three experimental and two control groups (n = 10). DL: root surfaces treated with DL (810 nm, continuous mode, 1.0 W, 30 s), FGF: topical application of FGF gel to the root surface and in the alveolar wound, DL + FGF: DL and topical application of FGF gel, C+: no treatment after extraction and immediate replantation and C−: no treatment after extraction and replantation after 60 min. In the experimental groups, the specimens were kept dry for 60 min, the pulps were removed and the canals were filled with calcium hydroxide paste prior to tooth replantation. The animals were euthanized after 60 days. The specimens were processed for radiographic, histological and immunohistochemical analyses. The radiographic analysis showed fewer resorptive areas in DL + FGF (P < 0.05). The histological and immunohistochemical analyses showed that the DL group had lower mean values of ankylosis, replacement and inflammatory resorption when compared to C−, not differing statistically from C+. DL + FGF produced significantly more collagen fibers (type I and type III) than C−, not differing from C+ in the case of type I fibers (P < 0.05). DL, with or without FGF, reduced the occurrence of external root resorption and ankylosis. Periodontal healing was favored and some fiber reinsertion occurred only when FGF was used.
- 12 January 2012
- Published by Wiley in Dental Traumatology
- Vol. 28 (6) , 429-436
Root surface treatment using diode laser in delayed tooth replantation: radiographic and histomorphometric analyses in rats
– Background aim: The aim of this study was to evaluate, by radiographic and histomorphometric analyses, the effects of high‐power diode laser irradiation on the root surfaces of delayed replanted rat teeth. Material and methods: Maxillary right incisors were extracted from 60 Wistar rats and kept dry for 60 min. Subsequently, the root canals were prepared and filled with calcium hydroxide paste. According to the root surface treatment before the replantation, the teeth were assigned to four groups (n = 15): G1 (negative control) – no root surface treatment; G2 (positive control) – treated with 2% sodium fluoride solution; G3 – irradiated with a high‐power diode laser (810 nm, continuous mode, 1.0 W, 30 s); and G4 – irradiated with a diode laser using the same parameters as those used for G3 but in pulsed mode. The rats were euthanized after 15, 30, and 60 days of replantation. The specimens were digitally radiographed and processed for histomorphometric analysis to determine the average root resorption areas and to evaluate the histological events. Results: The percentage of root resorption was in the following order: G1 > G2 > G4 > G3. Both histomorphometric and radiographic analyses showed significantly lower means (P < 0.05) of the occurrence of root resorption in the irradiated groups (G3 and G4) when compared to the control groups (G1 and G2). Replacement resorption and ankylosis were observed in histological sections only after 30 and 60 days; however, such events were not observed in G3. Conclusion: Root surface treatments with high‐powered diode laser irradiation prior to delayed replantation reduced the occurrence of external root resorption compared to no treatment or sodium fluoride treatment at up to 60 days.
- 12 January 2012
- Published by Wiley in Dental Traumatology
- Vol. 28 (6) , 429-436
Root surface treatment using diode laser in delayed tooth replantation: radiographic and histomorphometric analyses in rats
– Background aim: The aim of this study was to evaluate, by radiographic and histomorphometric analyses, the effects of high‐power diode laser irradiation on the root surfaces of delayed replanted rat teeth. Material and methods: Maxillary right incisors were extracted from 60 Wistar rats and kept dry for 60 min. Subsequently, the root canals were prepared and filled with calcium hydroxide paste. According to the root surface treatment before the replantation, the teeth were assigned to four groups (n = 15): G1 (negative control) – no root surface treatment; G2 (positive control) – treated with 2% sodium fluoride solution; G3 – irradiated with a high‐power diode laser (810 nm, continuous mode, 1.0 W, 30 s); and G4 – irradiated with a diode laser using the same parameters as those used for G3 but in pulsed mode. The rats were euthanized after 15, 30, and 60 days of replantation. The specimens were digitally radiographed and processed for histomorphometric analysis to determine the average root resorption areas and to evaluate the histological events. Results: The percentage of root resorption was in the following order: G1 > G2 > G4 > G3. Both histomorphometric and radiographic analyses showed significantly lower means (P < 0.05) of the occurrence of root resorption in the irradiated groups (G3 and G4) when compared to the control groups (G1 and G2). Replacement resorption and ankylosis were observed in histological sections only after 30 and 60 days; however, such events were not observed in G3. Conclusion: Root surface treatments with high‐powered diode laser irradiation prior to delayed replantation reduced the occurrence of external root resorption compared to no treatment or sodium fluoride treatment at up to 60 days.
- 1 August 2011
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 29 (8) , 559-563
Effect of Chemical Substances in Removing Methylene Blue After Photodynamic Therapy in Root Canal Treatment
Background and objective: The disadvantage of photodynamic therapy (PDT) is in the photosensitizing agents that may stain the tooth structure. There is no register of PDT studies evaluating protocols to minimize that concern. The present study evaluated the efficiency of chemical adjuncts in methylene blue dye (MB) removal after PDT. Materials and methods: Forty single-rooted teeth, after root canal preparation, were filled with 0.01% MB for 5 min, and irradiated with diode laser 660 nm at 40 mW for 240 sec (total energy 9.6 J). The specimens were divided into four groups ( n = 10), according to the chemical adjuncts used for dye removal: (a) 2.5% sodium hypochlorite (NaOCl); (b) 2.5% NaOCl + Endo-PTC cream; (c) 70% ethyl alcohol and (d) saline (control). The crowns were sectioned and fixed in a device. Photographs were taken before the PDT (T0), immediately after (T1) and upon dye removal (T2). The chromatic alterations were evaluated using Adobe Photoshop and K values were determined in four fixed points of each crown. Results: K values (dental staining) increased in all groups when comparing T0 and T1. The effectiveness of the tested adjuncts was, in decreasing order: G1 (−3.11) > G2 (−2.97) > G3 (−1.28) > G4 (−1.19), not observing significant statistical differences ( p < 0.05) between G1 and G2 and also between G3 and G4. Conclusions: Protocols to remove photosensitizing dyes should be applied after PDT in order to minimize dental stain. The protocols tested in this study by using 2.5% NaOCl, associated or not with Endo-PTC cream, were effective in avoiding tooth staining caused by MB during PDT.
- 1 August 2011
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 29 (8) , 559-563
Effect of Chemical Substances in Removing Methylene Blue After Photodynamic Therapy in Root Canal Treatment
Background and objective: The disadvantage of photodynamic therapy (PDT) is in the photosensitizing agents that may stain the tooth structure. There is no register of PDT studies evaluating protocols to minimize that concern. The present study evaluated the efficiency of chemical adjuncts in methylene blue dye (MB) removal after PDT. Materials and methods: Forty single-rooted teeth, after root canal preparation, were filled with 0.01% MB for 5 min, and irradiated with diode laser 660 nm at 40 mW for 240 sec (total energy 9.6 J). The specimens were divided into four groups ( n = 10), according to the chemical adjuncts used for dye removal: (a) 2.5% sodium hypochlorite (NaOCl); (b) 2.5% NaOCl + Endo-PTC cream; (c) 70% ethyl alcohol and (d) saline (control). The crowns were sectioned and fixed in a device. Photographs were taken before the PDT (T0), immediately after (T1) and upon dye removal (T2). The chromatic alterations were evaluated using Adobe Photoshop and K values were determined in four fixed points of each crown. Results: K values (dental staining) increased in all groups when comparing T0 and T1. The effectiveness of the tested adjuncts was, in decreasing order: G1 (−3.11) > G2 (−2.97) > G3 (−1.28) > G4 (−1.19), not observing significant statistical differences ( p < 0.05) between G1 and G2 and also between G3 and G4. Conclusions: Protocols to remove photosensitizing dyes should be applied after PDT in order to minimize dental stain. The protocols tested in this study by using 2.5% NaOCl, associated or not with Endo-PTC cream, were effective in avoiding tooth staining caused by MB during PDT.
- Open Access
- 1 April 2011
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 19 (2) , 113-117
Effect of nitric oxide inhibitor and donor substances on the infammatory process caused by endodontic irrigants
The aim of this study was to evaluate the effect of treatment with L-NAME and sodium nitroprussiate, substances that inhibit and release NO, respectively, on tissue tolerance to endodontic irrigants. The vital dye exudation method was used in a rat subcutaneous tissue model. Injections of 2% Evans blue were administered intravenously into the dorsal penial vein of 14 male rats (200-300 g). The NO inhibitor and donor substances were injected into the subcutaneous tissue in the dorsal region, forming two groups of animals: G1 was inoculated with L-NAME and G2 with sodium nitroprussiate. Both groups received injections of the test endodontic irrigants: acetic acid, 15% citric acid, 17% EDTA-T and saline (control). After 30 min, analysis of the extravasated dye was performed by light absorption spectrophotometry (620 nm). There was statistically significant difference (p<0.05) between groups 1 and 2 for all irrigants. L-NAME produced a less intense inflammatory reaction and nitroprussiate intensified this process. Independently of the administration of NO inhibitors and donors, EDTA-T produced the highest irritating potential in vital tissue among the tested irrigating solutions.
- 1 April 2011
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 19 (2) , 113-117
Open AccessEffect of nitric oxide inhibitor and donor substances on the infammatory process caused by endodontic irrigants
The aim of this study was to evaluate the effect of treatment with L-NAME and sodium nitroprussiate, substances that inhibit and release NO, respectively, on tissue tolerance to endodontic irrigants. The vital dye exudation method was used in a rat subcutaneous tissue model. Injections of 2% Evans blue were administered intravenously into the dorsal penial vein of 14 male rats (200-300 g). The NO inhibitor and donor substances were injected into the subcutaneous tissue in the dorsal region, forming two groups of animals: G1 was inoculated with L-NAME and G2 with sodium nitroprussiate. Both groups received injections of the test endodontic irrigants: acetic acid, 15% citric acid, 17% EDTA-T and saline (control). After 30 min, analysis of the extravasated dye was performed by light absorption spectrophotometry (620 nm). There was statistically significant difference (p<0.05) between groups 1 and 2 for all irrigants. L-NAME produced a less intense inflammatory reaction and nitroprussiate intensified this process. Independently of the administration of NO inhibitors and donors, EDTA-T produced the highest irritating potential in vital tissue among the tested irrigating solutions.
- 1 February 2010
- Published by Elsevier in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
- Vol. 109 (2) , e154-e161
Attachment of cultured fibroblasts and ultrastructural analysis of simulated cervical resorptions treated with high-power lasers and MTA
- 1 February 2010
- Published by Elsevier in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
- Vol. 109 (2) , e154-e161
Attachment of cultured fibroblasts and ultrastructural analysis of simulated cervical resorptions treated with high-power lasers and MTA