Syed Asad Hussain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Syed Asad Hussain has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Animesh Jha
School of Chemical and Process Engineering, University of Leeds, Leeds, LS2 9JT, UK
4 shared publications - Antonios D. Anastasiou
Laboratory of Complex fluids and microfluidics, Department of Chemical Engineering, University of Manchester, Manchester, M1 9PL, UK
4 shared publications S. Strafford
Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT, UK
4 shared publicationsA.P. Brown
School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT, UK
3 shared publicationsC.L. Thomson
SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS, UK
3 shared publicationsM. Malinowski
Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT, UK
3 shared publications
Latest Publications
- Open Access
- 30 October 2020
- Published by Wiley in Journal of Microscopy
- Vol. 288 (2) , 106-116
Wavefront‐sensorless adaptive optics with a laser‐free spinning disk confocal microscope
Adaptive optics is being applied widely to a range of microscopies in order to improve imaging quality in the presence of specimen‐induced aberrations. We present here the first implementation of wavefront‐sensorless adaptive optics for a laser‐free, aperture correlation, spinning disk microscope. This widefield method provides confocal‐like optical sectioning through use of a patterned disk in the illumination and detection paths. Like other high‐resolution microscopes, its operation is compromised by aberrations due to refractive index mismatch and variations within the specimen. Correction of such aberrations shows improved signal level, contrast and resolution. This article is protected by copyright. All rights reserved
- 30 October 2020
- Published by Wiley in Journal of Microscopy
- Vol. 288 (2) , 106-116
Open AccessWavefront‐sensorless adaptive optics with a laser‐free spinning disk confocal microscope
Adaptive optics is being applied widely to a range of microscopies in order to improve imaging quality in the presence of specimen‐induced aberrations. We present here the first implementation of wavefront‐sensorless adaptive optics for a laser‐free, aperture correlation, spinning disk microscope. This widefield method provides confocal‐like optical sectioning through use of a patterned disk in the illumination and detection paths. Like other high‐resolution microscopes, its operation is compromised by aberrations due to refractive index mismatch and variations within the specimen. Correction of such aberrations shows improved signal level, contrast and resolution. This article is protected by copyright. All rights reserved
- Open Access
- 27 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Discovery of Several New Families of Saturable Absorbers for Ultrashort Pulsed Laser Systems
Saturable Absorber (SA) is a key element of any passive mode-locked laser system to provide ultrashort laser system. So far various materials have been proposed that could be used for this purpose. However, the field is still looking for new ways to make the fabrication process easier and cost-effective. Another challenge in testing mode-locked laser systems using various SA samples is the lack of knowledge in preparing these by laser physicists given this is outside their remit of expertise. In this study, we have proposed a novel method to produce these SAs from plastic materials and glycol. Our new method relies upon increase in thickness up to a value where the modulation depth is enough to give stable ultrashort pulses. Although we have shown this method for four materials; similar approach could be applied to any material. This will open the door of unlimited families of SAs that could be easily prepared and applied without any prior knowledge in material sciences.
- 27 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessDiscovery of Several New Families of Saturable Absorbers for Ultrashort Pulsed Laser Systems
Saturable Absorber (SA) is a key element of any passive mode-locked laser system to provide ultrashort laser system. So far various materials have been proposed that could be used for this purpose. However, the field is still looking for new ways to make the fabrication process easier and cost-effective. Another challenge in testing mode-locked laser systems using various SA samples is the lack of knowledge in preparing these by laser physicists given this is outside their remit of expertise. In this study, we have proposed a novel method to produce these SAs from plastic materials and glycol. Our new method relies upon increase in thickness up to a value where the modulation depth is enough to give stable ultrashort pulses. Although we have shown this method for four materials; similar approach could be applied to any material. This will open the door of unlimited families of SAs that could be easily prepared and applied without any prior knowledge in material sciences.
- Open Access
- 21 November 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 17282
Comparison of Graphene and Carbon Nanotube Saturable Absorbers for Wavelength and Pulse Duration Tunability
Graphene (Gr) and Carbon nanotube (CNT) saturable absorbers (SAs) are considered as broadband absorbers and have been used in various studies in the past to get a broad wavelength and pulse duration tunable laser. However, the literature lacks a comparative study on these SAs where one will continue to give longer pulses than the other. In this paper we have compared these two SAs and provided a guideline on how to design them for tunable operation. The parameters that have been compared in this research can be used for other broad gain materials and SAs.
- 21 November 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 17282
Open AccessComparison of Graphene and Carbon Nanotube Saturable Absorbers for Wavelength and Pulse Duration Tunability
Graphene (Gr) and Carbon nanotube (CNT) saturable absorbers (SAs) are considered as broadband absorbers and have been used in various studies in the past to get a broad wavelength and pulse duration tunable laser. However, the literature lacks a comparative study on these SAs where one will continue to give longer pulses than the other. In this paper we have compared these two SAs and provided a guideline on how to design them for tunable operation. The parameters that have been compared in this research can be used for other broad gain materials and SAs.
- 10 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 31 (12) , 990-993
Ultrashort Dual Colour Laser at 1.55 and 1.88 $\mu$ m by Using a Carbon Nanotube Saturable AbsorberIn this study we have achieved passive modelocked lasers at 1.55 and 1.88 lm that can provide ultrashort (pulse duration~1ps) pulses by using a single carbon nanotube saturable absorber. The fibre cavity that has been constructed is compact, simple and stable against mechanical perturbation which makes this laser superior to solid-state lasers. This study has shown that a carbon nanotube saturable absorber is an alternative to graphene and has two mode-locked wavelengths that are approximately 250 nm apart. The resultant laser is useful for applications where compact dual colour wavelengths are required.
- 10 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 31 (12) , 990-993
Ultrashort Dual Colour Laser at 1.55 and 1.88 $\mu$ m by Using a Carbon Nanotube Saturable AbsorberIn this study we have achieved passive modelocked lasers at 1.55 and 1.88 lm that can provide ultrashort (pulse duration~1ps) pulses by using a single carbon nanotube saturable absorber. The fibre cavity that has been constructed is compact, simple and stable against mechanical perturbation which makes this laser superior to solid-state lasers. This study has shown that a carbon nanotube saturable absorber is an alternative to graphene and has two mode-locked wavelengths that are approximately 250 nm apart. The resultant laser is useful for applications where compact dual colour wavelengths are required.
- 5 November 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 113 (19) , 193102
Wavelength tunable soliton rains in a nanotube-mode locked Tm-doped fiber laser
We report soliton rains in a tunable Tm-doped fiber laser mode locked by carbon nanotubes. We also detect their second- and third-harmonics. We achieve a tunability of over 56 nm, from 1877 to 1933 nm, by introducing a polarization-maintaining isolator and two in-line polarization controllers. This makes our system promising as a tunable filter for ultrafast spectroscopy.
- 5 November 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 113 (19) , 193102
Wavelength tunable soliton rains in a nanotube-mode locked Tm-doped fiber laser
We report soliton rains in a tunable Tm-doped fiber laser mode locked by carbon nanotubes. We also detect their second- and third-harmonics. We achieve a tunability of over 56 nm, from 1877 to 1933 nm, by introducing a polarization-maintaining isolator and two in-line polarization controllers. This makes our system promising as a tunable filter for ultrafast spectroscopy.
- Open Access
- 1 April 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 71, 86-95
Exogenous mineralization of hard tissues using photo-absorptive minerals and femto-second lasers; the case of dental enamel
- 1 April 2018
- Published by Elsevier in Acta Biomaterialia
- Vol. 71, 86-95
Open AccessExogenous mineralization of hard tissues using photo-absorptive minerals and femto-second lasers; the case of dental enamel
- 1 January 2018
- Published by Optica Publishing Group
- p. JTh2A.179
Broadband Wavelength Tunable Mode-Locked Tm-Doped Fiber Laser Based on Carbon Nanotubes
We report a broadband tunable Tm-doped fiber laser mode-locked by carbon nanotubes. The wavelength tunability is achieved by introducing a polarization-maintaining isolator and two polarization controllers and the tunable range is up to 60 nm.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTh2A.179
Broadband Wavelength Tunable Mode-Locked Tm-Doped Fiber Laser Based on Carbon Nanotubes
We report a broadband tunable Tm-doped fiber laser mode-locked by carbon nanotubes. The wavelength tunability is achieved by introducing a polarization-maintaining isolator and two polarization controllers and the tunable range is up to 60 nm.
- Open Access
- 1 June 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 75, 885-894
β-pyrophosphate: A potential biomaterial for dental applications
- 1 June 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 75, 885-894
Open Accessβ-pyrophosphate: A potential biomaterial for dental applications
- 18 January 2017
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (5) , 945-953
Cell viability and shock wave amplitudes in the endothelium of porcine cornea exposed to ultrashort laser pulses
Purpose Some forms of keratoplasty assisted by ultrashort-pulse lasers require performing laser cuts close to the endothelium, which requires the knowledge of “safe” values concerning incision depth and pulse energy preserving endothelial cell viability. Our study aims to determine the thresholds for cell death in porcine corneas exposed to ultrashort laser pulses, in terms of laser pulse energy and nearness of the impacts to the endothelium. Methods Using a laboratory laser set-up, lamellar cuts were induced while varying pulse energies and distances from the endothelium. A fluorescent staining protocol was used to determine the percentage of surviving endothelial cells. Numerical simulations of the Euler equations for compressible fluids provided pressure level and axial and radial pressure gradient estimates at the endothelium. Results Ninety percent of the endothelial cells survived when using 16.5 μJ pulses no closer than 200 μm to the endothelium, or pulses not exceeding 2 μJ at a distance of 50 μm. The comparison of the observed percentage of surviving cells with the estimates of the shock wave amplitudes and gradients generated by the laser pulses yielded cell death thresholds at amplitudes in the megapascal range, or gradients of the order of 108 Pa/m. Conclusions Our results provide limits in terms of pulse energy and distance of the incision from the endothelium within which endothelial cell viability is preserved. Current forms of corneal laser surgery are compatible with these limits. However, these limits will need to be considered for the development of future laser routines working in close proximity to the endothelium.
- 18 January 2017
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (5) , 945-953
Cell viability and shock wave amplitudes in the endothelium of porcine cornea exposed to ultrashort laser pulses
Purpose Some forms of keratoplasty assisted by ultrashort-pulse lasers require performing laser cuts close to the endothelium, which requires the knowledge of “safe” values concerning incision depth and pulse energy preserving endothelial cell viability. Our study aims to determine the thresholds for cell death in porcine corneas exposed to ultrashort laser pulses, in terms of laser pulse energy and nearness of the impacts to the endothelium. Methods Using a laboratory laser set-up, lamellar cuts were induced while varying pulse energies and distances from the endothelium. A fluorescent staining protocol was used to determine the percentage of surviving endothelial cells. Numerical simulations of the Euler equations for compressible fluids provided pressure level and axial and radial pressure gradient estimates at the endothelium. Results Ninety percent of the endothelial cells survived when using 16.5 μJ pulses no closer than 200 μm to the endothelium, or pulses not exceeding 2 μJ at a distance of 50 μm. The comparison of the observed percentage of surviving cells with the estimates of the shock wave amplitudes and gradients generated by the laser pulses yielded cell death thresholds at amplitudes in the megapascal range, or gradients of the order of 108 Pa/m. Conclusions Our results provide limits in terms of pulse energy and distance of the incision from the endothelium within which endothelial cell viability is preserved. Current forms of corneal laser surgery are compatible with these limits. However, these limits will need to be considered for the development of future laser routines working in close proximity to the endothelium.