Venu Sonti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Venu Sonti has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Sachin Jain
Department of Physics, Indian Institute of Science Education and Research, Pune, India
15 shared publications - S. V. S. Phani Kumar Ch
Department of Electrical Engineering, National Institute of Technology, Raipur, India
5 shared publications - Arpan Hota
Indian Institute of Technology (IIT Kharagpur)
4 shared publications - Vivek Agarwal
Department of Electrical Engineering, Indian Institute of Technology Bombay, Mumbai, India
4 shared publications - Amit Kumar Singh
National Institute of Technology (NIT) Raipur
3 shared publications Sachin Jain
2 shared publications
Latest Publications
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. PP (00983063) , 1
An Optimized Half Bridge Type Single-Phase 5-level Switched Capacitor Inverter with Charging State Availability in Each Switching Period
Half Bridge (HB) type 5-level inverters (5LI) are gaining popularity due to negligible ground leakage current and improved harmonic performance. They often use a switched-capacitor (SC) network to prevent the loss of dc-bus utilization in a compact manner while incorporating HB feature. However, the existing SC-based 5LIs either have a high switch count or there is a lack of SC charging states in each switching cycle. To overcome these drawbacks, this paper presents a novel HB type 5LI with low switch count for transformer-less solar PV applications where the SC can be charged during each switching cycle. Other advantages of the proposed topology include reduced total blocking voltage of the switches, maximum DC-bus utilization, low SC voltage ripple, symmetric operation, reduced SC charging current and low losses. All the modes of operation and SC design method are presented. A thorough comparison has been carried out with the existing topologies to showcase the advantages of the proposed topology. Key experimental results obtained from a laboratory prototype are presented to justify the various theoretical claims.
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. PP (00983063) , 1
An Optimized Half Bridge Type Single-Phase 5-level Switched Capacitor Inverter with Charging State Availability in Each Switching Period
Half Bridge (HB) type 5-level inverters (5LI) are gaining popularity due to negligible ground leakage current and improved harmonic performance. They often use a switched-capacitor (SC) network to prevent the loss of dc-bus utilization in a compact manner while incorporating HB feature. However, the existing SC-based 5LIs either have a high switch count or there is a lack of SC charging states in each switching cycle. To overcome these drawbacks, this paper presents a novel HB type 5LI with low switch count for transformer-less solar PV applications where the SC can be charged during each switching cycle. Other advantages of the proposed topology include reduced total blocking voltage of the switches, maximum DC-bus utilization, low SC voltage ripple, symmetric operation, reduced SC charging current and low losses. All the modes of operation and SC design method are presented. A thorough comparison has been carried out with the existing topologies to showcase the advantages of the proposed topology. Key experimental results obtained from a laboratory prototype are presented to justify the various theoretical claims.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4024-4035
Reduction of Common Mode Voltage Transitions in Two-Level Voltage Source Inverters Using Predictive Control and H10 Inverter Topology
This paper presents a Predictive Control-based H10 inverter (PCH10) strategy designed to reduce common-mode voltage (CMV) transitions. The proposed solution mitigates the CMV transition particularly those caused by switching to zero-voltage vector (ZVV). The proposed solution also considers the effect of the DJC while retaining the CMV magnitude to the previous active state. Thus, the proposed predictive control method strategically avoids transitions during the zero state and the system experiences CMV transitions only during changes between active states. Reduction in the magnitude and number of CMV transitions further helps in the reduction of the common mode current (CMC). Reduced CMC directly reduces EMI, safeguards motor drive performance, and enhances overall system reliability. Details of the PCH10 strategy with the required analysis are presented in the manuscript. The effectiveness of the given approach is validated through detailed required simulations and experimental results.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4024-4035
Reduction of Common Mode Voltage Transitions in Two-Level Voltage Source Inverters Using Predictive Control and H10 Inverter Topology
This paper presents a Predictive Control-based H10 inverter (PCH10) strategy designed to reduce common-mode voltage (CMV) transitions. The proposed solution mitigates the CMV transition particularly those caused by switching to zero-voltage vector (ZVV). The proposed solution also considers the effect of the DJC while retaining the CMV magnitude to the previous active state. Thus, the proposed predictive control method strategically avoids transitions during the zero state and the system experiences CMV transitions only during changes between active states. Reduction in the magnitude and number of CMV transitions further helps in the reduction of the common mode current (CMC). Reduced CMC directly reduces EMI, safeguards motor drive performance, and enhances overall system reliability. Details of the PCH10 strategy with the required analysis are presented in the manuscript. The effectiveness of the given approach is validated through detailed required simulations and experimental results.
- Open Access
- 13 March 2026
- Published by Springer Nature in Energy Informatics
- Vol. 9 (1)
Explainable AI-driven energy forecasting: A DGMR-based feature extraction and EGST-Net prediction framework for transparent decision-making
- 13 March 2026
- Published by Springer Nature in Energy Informatics
- Vol. 9 (1)
Open AccessExplainable AI-driven energy forecasting: A DGMR-based feature extraction and EGST-Net prediction framework for transparent decision-making
- 2 January 2026
- Published by Springer Nature
- p. 435-441
Single-Phase Multilevel Inverter with Switched Capacitor Topology for Leakage Current and Common Mode Voltage Reduction
- 2 January 2026
- Published by Springer Nature
- p. 435-441
Single-Phase Multilevel Inverter with Switched Capacitor Topology for Leakage Current and Common Mode Voltage Reduction
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 6928-6940
Multi-Phase DC-Decoupled Inverter Topology to Enhance Performance of Electronic Pole Changing Induction Motor Drive
The electronic-pole/mode changing (E-PC) mechanism includes wide flexible speed-torque ranges by operating induction motor drive (IMD) in different pole-phase combinations/modes. To have varied pole-phase combinations in IMD an inverter employing diverse pulse-width-modulation (PWM) strategies is required. The diverse PWM strategies result in common-mode-voltage (CMV) at the inverter. The inverter's CMV produces space-harmonics in IMD stator periphery. The space-harmonics are attributed to the common-mode-current produced by inverter's CMV. Thus, by inverter driven E-PC operation in IMD, a predominant torque ripple exists especially during high-pole modes. Moreover, E-PC IMD grieves flux and torque distortions due to improper stator-core magnetization and demagnetization during pole-changeover. Consequently, E-PC mechanism significantly affects drive dynamics. Therefore, the inverter's PWM should minimize the CMV at its individual operating modes and enable gradual pole-change in IMD during mode transition operation. In addition, the inverter should be less complexity in operation with optimum switch count. Hence, the paper proposes a multi-phase DC-decoupled inverter topology with hybrid-PWM technique considering the above-mentioned key points. The paper also gives switching-function analysis to verify inverter's CMV and finite-element analysis to examine the pole-changing behavior in IMD. The realization studies of the system are carried out in the ANSYS environment and elucidated experimentally.
- 11 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 6928-6940
Multi-Phase DC-Decoupled Inverter Topology to Enhance Performance of Electronic Pole Changing Induction Motor Drive
The electronic-pole/mode changing (E-PC) mechanism includes wide flexible speed-torque ranges by operating induction motor drive (IMD) in different pole-phase combinations/modes. To have varied pole-phase combinations in IMD an inverter employing diverse pulse-width-modulation (PWM) strategies is required. The diverse PWM strategies result in common-mode-voltage (CMV) at the inverter. The inverter's CMV produces space-harmonics in IMD stator periphery. The space-harmonics are attributed to the common-mode-current produced by inverter's CMV. Thus, by inverter driven E-PC operation in IMD, a predominant torque ripple exists especially during high-pole modes. Moreover, E-PC IMD grieves flux and torque distortions due to improper stator-core magnetization and demagnetization during pole-changeover. Consequently, E-PC mechanism significantly affects drive dynamics. Therefore, the inverter's PWM should minimize the CMV at its individual operating modes and enable gradual pole-change in IMD during mode transition operation. In addition, the inverter should be less complexity in operation with optimum switch count. Hence, the paper proposes a multi-phase DC-decoupled inverter topology with hybrid-PWM technique considering the above-mentioned key points. The paper also gives switching-function analysis to verify inverter's CMV and finite-element analysis to examine the pole-changing behavior in IMD. The realization studies of the system are carried out in the ANSYS environment and elucidated experimentally.
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (3) , 1037-1048
High-Frequency Model for Analyzing Leakage Currents in Electronic Pole-Changing Induction Motor Drive
This paper presents a high-frequency model to analyze leakage current (LC) in electronic-pole-changing (EP-C) induction motor drives (IMDs). LC flows through parasitic capacitances in inverter-fed drive systems, resulting from the equivalent common-mode voltage (E-CMV) generated by the inverter's high-frequency PWM strategy. Further, for EP-C operation, different PWM strategies are required to operate IMD in different pole-phase combinations. Additionally, high-frequency LCs contribute to electromagnetic interference (EMI) in the system. Thus, it becomes essential to analyze in all different IMD's pole-phase combinations. This is because nature of these patterns is critical for both steady-state and pole transition operations in EP-C IMD, as they may lead to drive failure due to the breakdown of parasitic capacitances. Consequently, this paper proposes an analysis to examine E-CMV and LC patterns using the switching function concept and a high-frequency IMD model for EP-C IMD operation. Furthermore, this analysis assists in deducing PWM strategies with optimal switching frequency ranges for smoother EP-C operation. To demonstrate the proposed analysis, two pole-phase combinations (3-ϕ, 12-pole, 9-ϕ, 4-pole) in EP-C IMD are considered with different PWM techniques. The analysis is conducted in the ANSYS simulation environment and verified experimentally.
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (3) , 1037-1048
High-Frequency Model for Analyzing Leakage Currents in Electronic Pole-Changing Induction Motor Drive
This paper presents a high-frequency model to analyze leakage current (LC) in electronic-pole-changing (EP-C) induction motor drives (IMDs). LC flows through parasitic capacitances in inverter-fed drive systems, resulting from the equivalent common-mode voltage (E-CMV) generated by the inverter's high-frequency PWM strategy. Further, for EP-C operation, different PWM strategies are required to operate IMD in different pole-phase combinations. Additionally, high-frequency LCs contribute to electromagnetic interference (EMI) in the system. Thus, it becomes essential to analyze in all different IMD's pole-phase combinations. This is because nature of these patterns is critical for both steady-state and pole transition operations in EP-C IMD, as they may lead to drive failure due to the breakdown of parasitic capacitances. Consequently, this paper proposes an analysis to examine E-CMV and LC patterns using the switching function concept and a high-frequency IMD model for EP-C IMD operation. Furthermore, this analysis assists in deducing PWM strategies with optimal switching frequency ranges for smoother EP-C operation. To demonstrate the proposed analysis, two pole-phase combinations (3-ϕ, 12-pole, 9-ϕ, 4-pole) in EP-C IMD are considered with different PWM techniques. The analysis is conducted in the ANSYS simulation environment and verified experimentally.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (4) , 1634-1643
Common Mode and Terminal Voltages With Effect of Device Junction Capacitance in Five-Level Transformerless PV Inverter
This paper presents the analysis of common mode and terminal voltages by considering the effect of device junction capacitance in single-phase DC-decoupled transformerless PV inverter configuration. The common mode and terminal voltages (CMTVs) analysis considers device junction capacitance (DJC), inverter structure, and switching pattern. The generalized expression for CMTVs is derived considering DJC, inverter structure, and switching pattern. The inverter structure and PWM technique can be modified or designed to minimize or eliminate the highfrequency switching transitions (HFSTs) using the derived generalized expression of CMTVs. This further alleviates the common mode and leakage currents flowing through the parasitic capacitance of the PV inverter system. Further, an improved pulse width modulation (PWM) technique is also designed for the five-level cascaded multi-level inverter (CMLI), which reduces the distortions in the inverter output current apart from alleviating the leakage current. This manuscript presents a detailed analysis for the derivation of generalized expression using the given device junction capacitance-based switching function analysis. The derived expression is further validated using simulation and experimental results
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (4) , 1634-1643
Common Mode and Terminal Voltages With Effect of Device Junction Capacitance in Five-Level Transformerless PV Inverter
This paper presents the analysis of common mode and terminal voltages by considering the effect of device junction capacitance in single-phase DC-decoupled transformerless PV inverter configuration. The common mode and terminal voltages (CMTVs) analysis considers device junction capacitance (DJC), inverter structure, and switching pattern. The generalized expression for CMTVs is derived considering DJC, inverter structure, and switching pattern. The inverter structure and PWM technique can be modified or designed to minimize or eliminate the highfrequency switching transitions (HFSTs) using the derived generalized expression of CMTVs. This further alleviates the common mode and leakage currents flowing through the parasitic capacitance of the PV inverter system. Further, an improved pulse width modulation (PWM) technique is also designed for the five-level cascaded multi-level inverter (CMLI), which reduces the distortions in the inverter output current apart from alleviating the leakage current. This manuscript presents a detailed analysis for the derivation of generalized expression using the given device junction capacitance-based switching function analysis. The derived expression is further validated using simulation and experimental results
- Open Access
- 21 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
A Constant Common Mode Voltage Single-Phase Five-Level Transformerless PV Inverter Considering the Effect of Switch Device Junction Capacitance
Constant common mode voltage (CCMV) is critical in Solar Photovoltaic (SPV) systems. Maintaining CCMV further eliminates the transitions in the voltage across the parasitic capacitance of the PV panel, making it a low-frequency output voltage waveform. This further reduces the leakage and common mode current in the SPV systems. This paper presents a five-level switched capacitor PV inverter configuration that maintains the CCMV with low-frequency terminal voltage while considering the effect of switch device junction capacitance (SDJC). Thus, the proposed configuration eliminates the transitions in the common mode and terminal voltage due to the SDJC. The two switched capacitors employed in the proposed configuration are charged and discharged within each switching period, supporting the self-charge balance feature apart from low voltage and RMS current rating, reducing its size and value. Further, the proposed system effectively utilizes the PV source as switch capacitors, and the dc-bus buffer capacitor across the PV source comes in parallel in each switching period. The proposed configuration can also operate at lower modulation indices generating three levels with CCMV. A new mathematical analysis considering SDJC is given for the derivation of expression for terminal voltage and CMV, which is further verified using simulation and experimental results
- 21 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessA Constant Common Mode Voltage Single-Phase Five-Level Transformerless PV Inverter Considering the Effect of Switch Device Junction Capacitance
Constant common mode voltage (CCMV) is critical in Solar Photovoltaic (SPV) systems. Maintaining CCMV further eliminates the transitions in the voltage across the parasitic capacitance of the PV panel, making it a low-frequency output voltage waveform. This further reduces the leakage and common mode current in the SPV systems. This paper presents a five-level switched capacitor PV inverter configuration that maintains the CCMV with low-frequency terminal voltage while considering the effect of switch device junction capacitance (SDJC). Thus, the proposed configuration eliminates the transitions in the common mode and terminal voltage due to the SDJC. The two switched capacitors employed in the proposed configuration are charged and discharged within each switching period, supporting the self-charge balance feature apart from low voltage and RMS current rating, reducing its size and value. Further, the proposed system effectively utilizes the PV source as switch capacitors, and the dc-bus buffer capacitor across the PV source comes in parallel in each switching period. The proposed configuration can also operate at lower modulation indices generating three levels with CCMV. A new mathematical analysis considering SDJC is given for the derivation of expression for terminal voltage and CMV, which is further verified using simulation and experimental results
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 7103-7115
High-Performance Hybrid MPPT Algorithm Based Single-Stage Solar PV Fed Induction Motor Drive for Standalone Pump Application
The paper presents a high-performance hybrid sample-based perturb and observe (P&O) maximum power point tracking (MPPT) algorithm for a single-stage solar photovoltaic (SPV) fed open-end winding induction motor (OEWIM) driven standalone pumping system. Traditionally, the P&O algorithm utilizes slow sample-based computation for MPPT to avoid high oscillations near MPP. The slow sample-based algorithm has the drawback of poor tracking speed and loss of MPPT for the environmental change corresponding to the decrement in the PV power (i.e., step decrement in irradiance). Conversely, the algorithm designed for a faster sample rate faces the drawback of poor MPPT performance due to high oscillations near MPP. The proposed algorithm integrates the advantages of both fast and slow sample-based P&O MPPT algorithms. It switches to the fast sample-based MPPT when the PV operating point is away from MPP or there is a change in environmental conditions. It switches back to slow sample-based MPPT algorithms when the operating point reaches near MPP. The complete details of the proposed hybrid sample-based MPPT algorithm for the SPV pump application system are given in the paper. Further, a comparative analysis of the proposed algorithm performance with both fast and slow sample-based algorithms is also carried out using MATLAB/Simulink simulation environment. The simulation results demonstrate the superior performance of the proposed algorithm in terms of MPPT speed and accuracy. The enhanced MPP accuracy further improves the pump performance by minimizing torque and speed ripple. The robustness of the proposed strategy is also elucidated experimentally.
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 7103-7115
High-Performance Hybrid MPPT Algorithm Based Single-Stage Solar PV Fed Induction Motor Drive for Standalone Pump Application
The paper presents a high-performance hybrid sample-based perturb and observe (P&O) maximum power point tracking (MPPT) algorithm for a single-stage solar photovoltaic (SPV) fed open-end winding induction motor (OEWIM) driven standalone pumping system. Traditionally, the P&O algorithm utilizes slow sample-based computation for MPPT to avoid high oscillations near MPP. The slow sample-based algorithm has the drawback of poor tracking speed and loss of MPPT for the environmental change corresponding to the decrement in the PV power (i.e., step decrement in irradiance). Conversely, the algorithm designed for a faster sample rate faces the drawback of poor MPPT performance due to high oscillations near MPP. The proposed algorithm integrates the advantages of both fast and slow sample-based P&O MPPT algorithms. It switches to the fast sample-based MPPT when the PV operating point is away from MPP or there is a change in environmental conditions. It switches back to slow sample-based MPPT algorithms when the operating point reaches near MPP. The complete details of the proposed hybrid sample-based MPPT algorithm for the SPV pump application system are given in the paper. Further, a comparative analysis of the proposed algorithm performance with both fast and slow sample-based algorithms is also carried out using MATLAB/Simulink simulation environment. The simulation results demonstrate the superior performance of the proposed algorithm in terms of MPPT speed and accuracy. The enhanced MPP accuracy further improves the pump performance by minimizing torque and speed ripple. The robustness of the proposed strategy is also elucidated experimentally.