Henrique Resende Martins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Henrique Resende Martins has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Christine Azevedo Coste
Inria, Univ Montpellier, Montpellier, France
5 shared publications - Emerson Fachin-Martins
Universidade de Brasília
4 shared publications - Paulo Eugênio Silva
Physical Therapy Division, University Hospital of Brasília, University of Brasilia, Brasília, DF, Brazil; Health Sciences and Technologies PhD Program, University of Brasilia, DF, Brazil; Physical Therapy Division, Hospital de Base do Distrito Federal, Brasilia, DF, Brazil
3 shared publications - David Lobato Borges
Faculdade de Ceilândia (FCE) Programa de Pós‐Graduação em Ciências da Reabilitação (PPGCR) and Programa de Pós‐Graduação em Ciências e Tecnologias em Saúde (PPGCTS) Universidade de Brasília (UnB) Brasilia Brazil
2 shared publications - José Roberto de Deus Macedo
Health Sciences and Technologies PhD Program, Faculdade de Ciências e Tecnologias Em Saúde, Campus UnB Ceilândia Universidade de Brasília Brasília Brazil
2 shared publications - Martin Schmoll
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
2 shared publications
Latest Publications
- Open Access
- 4 September 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
Personalized FES-cycling patterns via optimal control: from musculoskeletal simulation to experimental validation
- 4 September 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
Open AccessPersonalized FES-cycling patterns via optimal control: from musculoskeletal simulation to experimental validation
- Open Access
- 26 May 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 23
FES-Cycling at the Cybathlon 2024: assessing accuracy of power-pedals for low power output in a virtual race scenario
The Cybathlon is a unique international competition platform for evaluating assistive technologies under real-life conditions. In the most recent edition,
- 26 May 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 23
Open AccessFES-Cycling at the Cybathlon 2024: assessing accuracy of power-pedals for low power output in a virtual race scenario
The Cybathlon is a unique international competition platform for evaluating assistive technologies under real-life conditions. In the most recent edition,
- 5 August 2024
- Published by Wiley in Physiotherapy Research International
- Vol. 29 (4) , e2115
Electrodiagnosis for mitigating false‐negative non‐responsiveness in electrical evoked contractions: A case series exploring probable polyneuromyopathy induced by nonuse
Introduction: The revised international standards for neurological classification of spinal cord injury (ISNCSCI) have facilitated the documentation of non‐spinal cord injury‐related impairments, such as chronic peripheral nerve injuries and muscle weakness due to immobility. This advancement addresses potential biases in muscle strength examinations. Utilizing electrically evoked contractions from paralyzed muscles, enhanced by electrodiagnosis, holds promise in identifying false‐negative diagnoses of non‐responsiveness to neuromuscular electrical stimulation. This concept prompts the exploration of polyneuromyopathy arising from nonuse in paralyzed muscles.Case Series Presentation: To substantiate our hypothesis, we recruited nine participants for a case series aimed at elucidating the potential benefits of incorporating the stimulus electrodiagnostic test (SET) to mitigate non‐responsiveness during preparation for functional electrical stimulation (FES)‐assisted cycling. In our convenience sample (n = 5), we conducted neurological mapping based on ISNCSCI and applied SET on the quadriceps. The SET guided optimal dosimetry for evoking contractions and revealed responses similar to those observed in peripheral neuropathies, with α coefficients equal to or lower than 2.00. This observation is likely attributable to nonuse of paralyzed muscles, indicative of an ongoing polyneuropathy in individuals with chronic spinal cord injury (SCI).Discussion: Among the nine initially recruited subjects, seven exhibited responsiveness to neuromuscular electrical stimulation (78% responsiveness), with two participants excluded based on exclusion criteria. In the final five reported cases, all displayed α coefficient values indicating impaired neuromuscular accommodation, and one presented no α coefficient within the normal range. The inclusion of electrodiagnosis appears effective in averting non‐responsiveness, suggesting the presence of ongoing polyneuropathies in paralyzed muscles.
- 5 August 2024
- Published by Wiley in Physiotherapy Research International
- Vol. 29 (4) , e2115
Electrodiagnosis for mitigating false‐negative non‐responsiveness in electrical evoked contractions: A case series exploring probable polyneuromyopathy induced by nonuse
Introduction: The revised international standards for neurological classification of spinal cord injury (ISNCSCI) have facilitated the documentation of non‐spinal cord injury‐related impairments, such as chronic peripheral nerve injuries and muscle weakness due to immobility. This advancement addresses potential biases in muscle strength examinations. Utilizing electrically evoked contractions from paralyzed muscles, enhanced by electrodiagnosis, holds promise in identifying false‐negative diagnoses of non‐responsiveness to neuromuscular electrical stimulation. This concept prompts the exploration of polyneuromyopathy arising from nonuse in paralyzed muscles.Case Series Presentation: To substantiate our hypothesis, we recruited nine participants for a case series aimed at elucidating the potential benefits of incorporating the stimulus electrodiagnostic test (SET) to mitigate non‐responsiveness during preparation for functional electrical stimulation (FES)‐assisted cycling. In our convenience sample (n = 5), we conducted neurological mapping based on ISNCSCI and applied SET on the quadriceps. The SET guided optimal dosimetry for evoking contractions and revealed responses similar to those observed in peripheral neuropathies, with α coefficients equal to or lower than 2.00. This observation is likely attributable to nonuse of paralyzed muscles, indicative of an ongoing polyneuropathy in individuals with chronic spinal cord injury (SCI).Discussion: Among the nine initially recruited subjects, seven exhibited responsiveness to neuromuscular electrical stimulation (78% responsiveness), with two participants excluded based on exclusion criteria. In the final five reported cases, all displayed α coefficient values indicating impaired neuromuscular accommodation, and one presented no α coefficient within the normal range. The inclusion of electrodiagnosis appears effective in averting non‐responsiveness, suggesting the presence of ongoing polyneuropathies in paralyzed muscles.
- 1 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1170-1179
Combining Functional Electrical Stimulation (FES) to Elicit Hand Movements and a Mechanical Orthosis to Passively Maintain Wrist and Fingers Position in Individuals With Tetraplegia: A Feasibility Test
- 1 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1170-1179
Combining Functional Electrical Stimulation (FES) to Elicit Hand Movements and a Mechanical Orthosis to Passively Maintain Wrist and Fingers Position in Individuals With Tetraplegia: A Feasibility Test
- 6 October 2023
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 39 (4) , 949-958
Towards innovative electrodiagnosis tests to investigate neuromuscular excitability dysfunction in critically ill patients: an agreement study
- 6 October 2023
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 39 (4) , 949-958
Towards innovative electrodiagnosis tests to investigate neuromuscular excitability dysfunction in critically ill patients: an agreement study
- Open Access
A Novel Functional Electrical Stimulation-Induced Cycling Controller Using Reinforcement Learning to Optimize Online Muscle Activation Pattern
This study introduces a novel controller based on a Reinforcement Learning (RL) algorithm for real-time adaptation of the stimulation pattern during FES-cycling. Core to our approach is the introduction of an RL agent that interacts with the cycling environment and learns through trial and error how to modulate the electrical charge applied to the stimulated muscle groups according to a predefined policy and while tracking a reference cadence. Instead of a static stimulation pattern to be modified by a control law, we hypothesized that a non-stationary baseline set of parameters would better adjust the amount of injected electrical charge to the time-varying characteristics of the musculature. Overground FES-assisted cycling sessions were performed by a subject with spinal cord injury (SCI AIS-A, T8). For tracking a predefined pedaling cadence, two closed-loop control laws were simultaneously used to modulate the pulse intensity of the stimulation channels responsible for evoking the muscle contractions. First, a Proportional-Integral (PI) controller was used to control the current amplitude of the stimulation channels over an initial parameter setting with predefined pulse amplitude, width and fixed frequency parameters. In parallel, an RL algorithm with a decayed-epsilon-greedy strategy was implemented to randomly explore nine different variations of pulse amplitude and width parameters over the same stimulation setting, aiming to adjust the injected electrical charge according to a predefined policy. The performance of this global control strategy was evaluated in two different RL settings and explored in two different cycling scenarios. The participant was able to pedal overground for distances over 3.5 km, and the results evidenced the RL agent learned to modify the stimulation pattern according to the predefined policy and was simultaneously able to track a predefined pedaling cadence. Despite the simplicity of our approach and the existence of more sophisticated RL algorithms, our method can be used to reduce the time needed to define stimulation patterns. Our results suggest interesting research possibilities to be explored in the future to improve cycling performance since more efficient stimulation cost dynamics can be explored and implemented for the agent to learn.
Open AccessA Novel Functional Electrical Stimulation-Induced Cycling Controller Using Reinforcement Learning to Optimize Online Muscle Activation Pattern
This study introduces a novel controller based on a Reinforcement Learning (RL) algorithm for real-time adaptation of the stimulation pattern during FES-cycling. Core to our approach is the introduction of an RL agent that interacts with the cycling environment and learns through trial and error how to modulate the electrical charge applied to the stimulated muscle groups according to a predefined policy and while tracking a reference cadence. Instead of a static stimulation pattern to be modified by a control law, we hypothesized that a non-stationary baseline set of parameters would better adjust the amount of injected electrical charge to the time-varying characteristics of the musculature. Overground FES-assisted cycling sessions were performed by a subject with spinal cord injury (SCI AIS-A, T8). For tracking a predefined pedaling cadence, two closed-loop control laws were simultaneously used to modulate the pulse intensity of the stimulation channels responsible for evoking the muscle contractions. First, a Proportional-Integral (PI) controller was used to control the current amplitude of the stimulation channels over an initial parameter setting with predefined pulse amplitude, width and fixed frequency parameters. In parallel, an RL algorithm with a decayed-epsilon-greedy strategy was implemented to randomly explore nine different variations of pulse amplitude and width parameters over the same stimulation setting, aiming to adjust the injected electrical charge according to a predefined policy. The performance of this global control strategy was evaluated in two different RL settings and explored in two different cycling scenarios. The participant was able to pedal overground for distances over 3.5 km, and the results evidenced the RL agent learned to modify the stimulation pattern according to the predefined policy and was simultaneously able to track a predefined pedaling cadence. Despite the simplicity of our approach and the existence of more sophisticated RL algorithms, our method can be used to reduce the time needed to define stimulation patterns. Our results suggest interesting research possibilities to be explored in the future to improve cycling performance since more efficient stimulation cost dynamics can be explored and implemented for the agent to learn.
- Open Access
- 1 September 2022
- Published by FapUNIFESP (SciELO) in Fisioterapia e Pesquisa
- Vol. 29 (3) , 245-251
Assessment of neuromuscular electrical stimulation in critically ill patients: physical therapists’ knowledge and barriers to its use
Transcutaneous neuromuscular electrical stimulation (NMES) is considered an important tool to prevent muscle mass and strength loss in patients admitted to intensive care units (ICU). This study aimed to evaluate physical therapists’ profile and knowledge of NMES and identify the main barriers to its use in ICUs. This observational cross-sectional study was conducted via a structured questionnaire created by the authors. It consisted of 12 objective questions to analyze physical therapists’ knowledge of NMES use in critically ill patients. Physical therapists were invited to participate in this study during an international symposium on NMES. In total, 56 physical therapists, with a mean age of 33.5±7.2 years and working an average of 9.7±7 years after graduation, completed the survey. Overall, 34 respondents worked in ICUs, of which only four (12%) reported regular NMES use in their ICUs. We found a low average of correct answers to our questionnaire (25%; 3/12). The main barriers reported to using NMES in ICUs were lack of knowledge (28; 50%) and equipment (24; 43%). The number of correct answers expert and non-expert physical therapists was not statistically significant (p=0.68). Thus, we observed participants’ poor knowledge of NMES use in critically ill patients. Respondents showed that NMES has been underused in their ICUs. Lack of knowledge and equipment seems to be the main barriers for the use of NMES in ICUs.
- 1 September 2022
- Published by FapUNIFESP (SciELO) in Fisioterapia e Pesquisa
- Vol. 29 (3) , 245-251
Open AccessAssessment of neuromuscular electrical stimulation in critically ill patients: physical therapists’ knowledge and barriers to its use
Transcutaneous neuromuscular electrical stimulation (NMES) is considered an important tool to prevent muscle mass and strength loss in patients admitted to intensive care units (ICU). This study aimed to evaluate physical therapists’ profile and knowledge of NMES and identify the main barriers to its use in ICUs. This observational cross-sectional study was conducted via a structured questionnaire created by the authors. It consisted of 12 objective questions to analyze physical therapists’ knowledge of NMES use in critically ill patients. Physical therapists were invited to participate in this study during an international symposium on NMES. In total, 56 physical therapists, with a mean age of 33.5±7.2 years and working an average of 9.7±7 years after graduation, completed the survey. Overall, 34 respondents worked in ICUs, of which only four (12%) reported regular NMES use in their ICUs. We found a low average of correct answers to our questionnaire (25%; 3/12). The main barriers reported to using NMES in ICUs were lack of knowledge (28; 50%) and equipment (24; 43%). The number of correct answers expert and non-expert physical therapists was not statistically significant (p=0.68). Thus, we observed participants’ poor knowledge of NMES use in critically ill patients. Respondents showed that NMES has been underused in their ICUs. Lack of knowledge and equipment seems to be the main barriers for the use of NMES in ICUs.
- Open Access
Development of a High-Power Capacity Open Source Electrical Stimulation System to Enhance Research into FES-Assisted Devices: Validation of FES Cycling
Since the first Cybathlon 2016, when twelve teams competed in the FES bike race, we have witnessed a global effort towards the development of stimulation and control strategies to improve FES-assisted devices, particularly for cycling, as a means to practice a recreational physical activity. As a result, a set of technical notes and research paved the way for many other studies and the potential behind FES-assisted cycling has been consolidated. However, engineering research needs instrumented devices to support novel developments and enable precise assessment. Therefore, some researchers struggle to develop their own FES-assisted devices or find it challenging to implement their instrumentation using commercial devices, which often limits the implementation of advanced control strategies and the possibility to connect different types of sensor. In this regard, we hypothesize that it would be advantageous for some researchers in our community to enjoy access to an entire open-source FES platform that allows different control strategies to be implemented, offers greater adaptability and power capacity than commercial devices, and can be used to assist different functional activities in addition to cycling. Hence, it appears to be of interest to make our proprietary electrical stimulation system an open-source device and to prove its capabilities by addressing all the aspects necessary to implement a FES cycling system. The high-power capacity stimulation device is based on a constant current topology that allows the creation of biphasic electrical pulses with amplitude, width, and frequency up to 150 mA, 1000 µs, and 100 Hz, respectively. A mobile application (Android) was developed to set and modify the stimulation parameters of up to eight stimulation channels. A proportional-integral controller was implemented for cadence tracking with the aim to improve the overall cycling performance. A volunteer with complete paraplegia participated in the functional testing of the system. He was able to cycle indoors for 45 min, accomplish distances of more than 5 km using a passive cycling trainer, and pedal 2400 m overground in 32 min. The results evidenced the capacity of our FES cycling system to be employed as a cycling tool for individuals with spinal cord injury. The methodological strategies used to improve FES efficiency suggest the possibility of maximizing pedaling duration through more advanced control techniques.
Open AccessDevelopment of a High-Power Capacity Open Source Electrical Stimulation System to Enhance Research into FES-Assisted Devices: Validation of FES Cycling
Since the first Cybathlon 2016, when twelve teams competed in the FES bike race, we have witnessed a global effort towards the development of stimulation and control strategies to improve FES-assisted devices, particularly for cycling, as a means to practice a recreational physical activity. As a result, a set of technical notes and research paved the way for many other studies and the potential behind FES-assisted cycling has been consolidated. However, engineering research needs instrumented devices to support novel developments and enable precise assessment. Therefore, some researchers struggle to develop their own FES-assisted devices or find it challenging to implement their instrumentation using commercial devices, which often limits the implementation of advanced control strategies and the possibility to connect different types of sensor. In this regard, we hypothesize that it would be advantageous for some researchers in our community to enjoy access to an entire open-source FES platform that allows different control strategies to be implemented, offers greater adaptability and power capacity than commercial devices, and can be used to assist different functional activities in addition to cycling. Hence, it appears to be of interest to make our proprietary electrical stimulation system an open-source device and to prove its capabilities by addressing all the aspects necessary to implement a FES cycling system. The high-power capacity stimulation device is based on a constant current topology that allows the creation of biphasic electrical pulses with amplitude, width, and frequency up to 150 mA, 1000 µs, and 100 Hz, respectively. A mobile application (Android) was developed to set and modify the stimulation parameters of up to eight stimulation channels. A proportional-integral controller was implemented for cadence tracking with the aim to improve the overall cycling performance. A volunteer with complete paraplegia participated in the functional testing of the system. He was able to cycle indoors for 45 min, accomplish distances of more than 5 km using a passive cycling trainer, and pedal 2400 m overground in 32 min. The results evidenced the capacity of our FES cycling system to be employed as a cycling tool for individuals with spinal cord injury. The methodological strategies used to improve FES efficiency suggest the possibility of maximizing pedaling duration through more advanced control techniques.
- Open Access
A Novel Framework for Quantifying Accuracy and Precision of Event Detection Algorithms in FES-Cycling
Functional electrical stimulation (FES) is a technique used in rehabilitation, allowing the recreation or facilitation of a movement or function, by electrically inducing the activation of targeted muscles. FES during cycling often uses activation patterns which are based on the crank angle of the pedals. Dynamic changes in their underlying predefined geometrical models (e.g., change in seating position) can lead to desynchronised contractions. Adaptive algorithms with a real-time interpretation of anatomical segments can avoid this and open new possibilities for the automatic design of stimulation patterns. However, their ability to accurately and precisely detect stimulation triggering events has to be evaluated in order to ensure their adaptability to real-case applications in various conditions. In this study, three algorithms (Hilbert, BSgonio, and Gait Cycle Index (GCI) Observer) were evaluated on passive cycling inertial data of six participants with spinal cord injury (SCI). For standardised comparison, a linear phase reference baseline was used to define target events (i.e., 10%, 40%, 60%, and 90% of the cycle’s progress). Limits of agreement (LoA) of ±10% of the cycle’s duration and Lin’s concordance correlation coefficient (CCC) were used to evaluate the accuracy and precision of the algorithm’s event detections. The delays in the detection were determined for each algorithm over 780 events. Analysis showed that the Hilbert and BSgonio algorithms validated the selected criteria (LoA: +5.17/−6.34% and +2.25/−2.51%, respectively), while the GCI Observer did not (LoA: +8.59/−27.89%). When evaluating control algorithms, it is paramount to define appropriate criteria in the context of the targeted practical application. To this end, normalising delays in event detection to the cycle’s duration enables the use of a criterion that stays invariable to changes in cadence. Lin’s CCC, comparing both linear correlation and strength of agreement between methods, also provides a reliable way of confirming comparisons between new control methods and an existing reference.
Open AccessA Novel Framework for Quantifying Accuracy and Precision of Event Detection Algorithms in FES-Cycling
Functional electrical stimulation (FES) is a technique used in rehabilitation, allowing the recreation or facilitation of a movement or function, by electrically inducing the activation of targeted muscles. FES during cycling often uses activation patterns which are based on the crank angle of the pedals. Dynamic changes in their underlying predefined geometrical models (e.g., change in seating position) can lead to desynchronised contractions. Adaptive algorithms with a real-time interpretation of anatomical segments can avoid this and open new possibilities for the automatic design of stimulation patterns. However, their ability to accurately and precisely detect stimulation triggering events has to be evaluated in order to ensure their adaptability to real-case applications in various conditions. In this study, three algorithms (Hilbert, BSgonio, and Gait Cycle Index (GCI) Observer) were evaluated on passive cycling inertial data of six participants with spinal cord injury (SCI). For standardised comparison, a linear phase reference baseline was used to define target events (i.e., 10%, 40%, 60%, and 90% of the cycle’s progress). Limits of agreement (LoA) of ±10% of the cycle’s duration and Lin’s concordance correlation coefficient (CCC) were used to evaluate the accuracy and precision of the algorithm’s event detections. The delays in the detection were determined for each algorithm over 780 events. Analysis showed that the Hilbert and BSgonio algorithms validated the selected criteria (LoA: +5.17/−6.34% and +2.25/−2.51%, respectively), while the GCI Observer did not (LoA: +8.59/−27.89%). When evaluating control algorithms, it is paramount to define appropriate criteria in the context of the targeted practical application. To this end, normalising delays in event detection to the cycle’s duration enables the use of a criterion that stays invariable to changes in cadence. Lin’s CCC, comparing both linear correlation and strength of agreement between methods, also provides a reliable way of confirming comparisons between new control methods and an existing reference.