Legeng Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Legeng Lin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoling Hu
The Hong Kong Polytechnic University
3 shared publications Fuhai Zhang
2 shared publications- Fuqiang Ye
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
2 shared publications Lei Yang
2 shared publicationsWaiming Li
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China
2 shared publications- Wanyi Qing
Department of Biomedical Engineering, Research Institute for Smart Aging (RISA), The Hong Kong Polytechnic University, Hong Kong, China
2 shared publications
Latest Publications
- Open Access
- 27 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 7
Sensorimotor Integration by Targeted Priming in Muscles with Electromyography-Driven Electro-vibro-feedback in Robot-Assisted Wrist/Hand Rehabilitation after Stroke
Restoring precise muscular control in the poststroke wrist/hand (W/H) demands sensorimotor integration to correct compensatory neuroplasticity. However, current rehabilitation robots inadequately modulate ascending somatosensory pathways from specific muscles. This study developed an electromyography (EMG)-driven soft robot with electro-vibro-feedback (EVF-robot) for targeted somatosensory priming in W/H muscles. This system integrates (a) focal vibratory stimulation and neuromuscular electrical stimulation for recruiting the somatosensory pathways of the targeted W/H flexors and extensors; (b) an EMG-driven control algorithm for strengthening the voluntary motor control of a driving muscle; and (c) robot assistance to achieve coordinated joint extension and flexion. In a single-arm trial with 20 sessions, 15 chronic stroke participants assisted by the system achieved significant improvements in voluntary W/H behavioral control, somatosensory feedback, and intermuscular coordination in the paretic upper limb ( P < 0.05). During their W/H extension, the cortical peaks of corticomuscular coherence shifted contralaterally for W/H extensors, and the ascending corticomuscular coherence from W/H flexors increased ( P < 0.05). These improvements persisted at the 3-month follow-up. The findings provide preliminary evidence that sensorimotor integration training with the EMG-driven EVF-robot may modulate compensatory neuroplasticity and facilitate improvements in coordinated motor control of the distal joints in individuals with chronic stroke.
- 27 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 7
Open AccessSensorimotor Integration by Targeted Priming in Muscles with Electromyography-Driven Electro-vibro-feedback in Robot-Assisted Wrist/Hand Rehabilitation after Stroke
Restoring precise muscular control in the poststroke wrist/hand (W/H) demands sensorimotor integration to correct compensatory neuroplasticity. However, current rehabilitation robots inadequately modulate ascending somatosensory pathways from specific muscles. This study developed an electromyography (EMG)-driven soft robot with electro-vibro-feedback (EVF-robot) for targeted somatosensory priming in W/H muscles. This system integrates (a) focal vibratory stimulation and neuromuscular electrical stimulation for recruiting the somatosensory pathways of the targeted W/H flexors and extensors; (b) an EMG-driven control algorithm for strengthening the voluntary motor control of a driving muscle; and (c) robot assistance to achieve coordinated joint extension and flexion. In a single-arm trial with 20 sessions, 15 chronic stroke participants assisted by the system achieved significant improvements in voluntary W/H behavioral control, somatosensory feedback, and intermuscular coordination in the paretic upper limb ( P < 0.05). During their W/H extension, the cortical peaks of corticomuscular coherence shifted contralaterally for W/H extensors, and the ascending corticomuscular coherence from W/H flexors increased ( P < 0.05). These improvements persisted at the 3-month follow-up. The findings provide preliminary evidence that sensorimotor integration training with the EMG-driven EVF-robot may modulate compensatory neuroplasticity and facilitate improvements in coordinated motor control of the distal joints in individuals with chronic stroke.
- 17 September 2025
- Published by Taylor & Francis
- p. 94-107
Mobile Upper Limb Robots for Self-Help Telerehabilitation
The current rehabilitation treatments for poststroke upper limb motor deficits are facing challenges such as resource-intensive rehabilitation programs, insufficient provision of effective rehabilitation services, and unequal access to necessary care after stroke. Mobile robots for self-help telerehabilitation in nontraditional settings are emerging as a promising supplement to the healthcare system. In this chapter, we will introduce a novel hybrid soft robot called the exoneuromusculoskeleton (ENMS). This robot integrates neuromuscular electrical stimulation, soft pneumatic muscle, exoskeleton techniques, and electromyography (EMG)-based detection of voluntary motor effort in one system. The assistive capability of ENMS was validated in patients with chronic stroke. It was also used in a home-based telerehabilitation clinical trial for participants with chronic stroke. The trial results demonstrated the feasibility and training effectiveness of the wrist–hand module in this system based on both clinical assessments and EMG parameters before and after the training program. Additionally, we proposed some future perspectives for the design of mobile robotic systems for telerehabilitation after stroke.
- 17 September 2025
- Published by Taylor & Francis
- p. 94-107
Mobile Upper Limb Robots for Self-Help Telerehabilitation
The current rehabilitation treatments for poststroke upper limb motor deficits are facing challenges such as resource-intensive rehabilitation programs, insufficient provision of effective rehabilitation services, and unequal access to necessary care after stroke. Mobile robots for self-help telerehabilitation in nontraditional settings are emerging as a promising supplement to the healthcare system. In this chapter, we will introduce a novel hybrid soft robot called the exoneuromusculoskeleton (ENMS). This robot integrates neuromuscular electrical stimulation, soft pneumatic muscle, exoskeleton techniques, and electromyography (EMG)-based detection of voluntary motor effort in one system. The assistive capability of ENMS was validated in patients with chronic stroke. It was also used in a home-based telerehabilitation clinical trial for participants with chronic stroke. The trial results demonstrated the feasibility and training effectiveness of the wrist–hand module in this system based on both clinical assessments and EMG parameters before and after the training program. Additionally, we proposed some future perspectives for the design of mobile robotic systems for telerehabilitation after stroke.
- Open Access
- 17 March 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 286
Comparison of Immediate Neuromodulatory Effects between Focal Vibratory and Electrical Sensory Stimulations after Stroke
Focal vibratory stimulation (FVS) and neuromuscular electrical stimulation (NMES) are promising technologies for sensory rehabilitation after stroke. However, the differences between these techniques in immediate neuromodulatory effects on the poststroke cortex are not yet fully understood. In this research, cortical responses in persons with chronic stroke (n = 15) and unimpaired controls (n = 15) were measured by whole-brain electroencephalography (EEG) when FVS and NMES at different intensities were applied transcutaneously to the forearm muscles. Both FVS and sensory-level NMES induced alpha and beta oscillations in the sensorimotor cortex after stroke, significantly exceeding baseline levels (p < 0.05). These oscillations exhibited bilateral sensory deficiency, early adaptation, and contralesional compensation compared to the control group. FVS resulted in a significantly faster P300 response (p < 0.05) and higher theta oscillation (p < 0.05) compared to NMES. The beta desynchronization over the contralesional frontal–parietal area remained during NMES (p > 0.05), but it was significantly weakened during FVS (p < 0.05) after stroke. The results indicated that both FVS and NMES effectively activated the sensorimotor cortex after stroke. However, FVS was particularly effective in eliciting transient involuntary attention, while NMES primarily fostered the cortical responses of the targeted muscles in the contralesional motor cortex.
- 17 March 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 286
Open AccessComparison of Immediate Neuromodulatory Effects between Focal Vibratory and Electrical Sensory Stimulations after Stroke
Focal vibratory stimulation (FVS) and neuromuscular electrical stimulation (NMES) are promising technologies for sensory rehabilitation after stroke. However, the differences between these techniques in immediate neuromodulatory effects on the poststroke cortex are not yet fully understood. In this research, cortical responses in persons with chronic stroke (n = 15) and unimpaired controls (n = 15) were measured by whole-brain electroencephalography (EEG) when FVS and NMES at different intensities were applied transcutaneously to the forearm muscles. Both FVS and sensory-level NMES induced alpha and beta oscillations in the sensorimotor cortex after stroke, significantly exceeding baseline levels (p < 0.05). These oscillations exhibited bilateral sensory deficiency, early adaptation, and contralesional compensation compared to the control group. FVS resulted in a significantly faster P300 response (p < 0.05) and higher theta oscillation (p < 0.05) compared to NMES. The beta desynchronization over the contralesional frontal–parietal area remained during NMES (p > 0.05), but it was significantly weakened during FVS (p < 0.05) after stroke. The results indicated that both FVS and NMES effectively activated the sensorimotor cortex after stroke. However, FVS was particularly effective in eliciting transient involuntary attention, while NMES primarily fostered the cortical responses of the targeted muscles in the contralesional motor cortex.
- 1 December 2021
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 212
Design and modeling of a hybrid soft-rigid hand exoskeleton for poststroke rehabilitation
- 1 December 2021
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 212
Design and modeling of a hybrid soft-rigid hand exoskeleton for poststroke rehabilitation
- 7 October 2019
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 47 (1) , 23-32
Variable impedance control of finger exoskeleton for hand rehabilitation following stroke
Purpose: The purpose of this paper is to propose a variable impedance control method of finger exoskeleton for hand rehabilitation using the contact forces between the finger and the exoskeleton, making the output trajectory of finger exoskeleton comply with the natural flexion-extension (NFE) trajectory accurately and adaptively. Design/methodology/approach: This paper presents a variable impedance control method based on fuzzy neural network (FNN). The impedance control system sets the contact forces and joint angles collected by sensors as input. Then it uses the offline-trained FNN system to acquire the impedance parameters in real time, thus realizing tracking the NFE trajectory. K-means clustering method is applied to construct FNN, which can obtain the number of fuzzy rules automatically. Findings: The results of simulations and experiments both show that the finger exoskeleton has an accurate output trajectory and an adaptive performance on three subjects with different physiological parameters. The variable impedance control system can drive the finger exoskeleton to comply with the NFE trajectory accurately and adaptively using the continuously changing contact forces. Originality/value: The finger is regarded as a part of the control system to get the contact forces between finger and exoskeleton, and the impedance parameters can be updated in real time to make the output trajectory comply with the NFE trajectory accurately and adaptively during the rehabilitation.
- 7 October 2019
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 47 (1) , 23-32
Variable impedance control of finger exoskeleton for hand rehabilitation following stroke
Purpose: The purpose of this paper is to propose a variable impedance control method of finger exoskeleton for hand rehabilitation using the contact forces between the finger and the exoskeleton, making the output trajectory of finger exoskeleton comply with the natural flexion-extension (NFE) trajectory accurately and adaptively. Design/methodology/approach: This paper presents a variable impedance control method based on fuzzy neural network (FNN). The impedance control system sets the contact forces and joint angles collected by sensors as input. Then it uses the offline-trained FNN system to acquire the impedance parameters in real time, thus realizing tracking the NFE trajectory. K-means clustering method is applied to construct FNN, which can obtain the number of fuzzy rules automatically. Findings: The results of simulations and experiments both show that the finger exoskeleton has an accurate output trajectory and an adaptive performance on three subjects with different physiological parameters. The variable impedance control system can drive the finger exoskeleton to comply with the NFE trajectory accurately and adaptively using the continuously changing contact forces. Originality/value: The finger is regarded as a part of the control system to get the contact forces between finger and exoskeleton, and the impedance parameters can be updated in real time to make the output trajectory comply with the NFE trajectory accurately and adaptively during the rehabilitation.
- Open Access
- 3 June 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (11) , 2291
Design of an Active and Passive Control System of Hand Exoskeleton for Rehabilitation
Aiming at stroke patients’ hand rehabilitation training, we present a hand exoskeleton with both active and passive control modes for neural rehabilitation. The exoskeleton control system is designed as a human–robot interaction control system based on field-programmable gate array (FPGA) and Android mobile terminal with good portability and openness. Passive rehabilitation pattern based on proportional derivative (PD) inverse dynamic control method and active rehabilitation pattern based on impedance method, are established respectively. By the comparison of the threshold value and the force on the fingertip of the exoskeleton from the sensor, the automatic switch between active and passive rehabilitation mode is accomplished. The hand model is built in Android environment that can synchronize the movement of the hand. It can also induce patients to participate in rehabilitation training actively. To verify the proposed control approach, we set up and conduct an experiment to do the passive rehabilitation mode, active rehabilitation mode, and active plus passive mode experimental researches. The experiment results effectively verify the feasibility of the exoskeleton system fulfilling the proposed control strategy.
- 3 June 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (11) , 2291
Open AccessDesign of an Active and Passive Control System of Hand Exoskeleton for Rehabilitation
Aiming at stroke patients’ hand rehabilitation training, we present a hand exoskeleton with both active and passive control modes for neural rehabilitation. The exoskeleton control system is designed as a human–robot interaction control system based on field-programmable gate array (FPGA) and Android mobile terminal with good portability and openness. Passive rehabilitation pattern based on proportional derivative (PD) inverse dynamic control method and active rehabilitation pattern based on impedance method, are established respectively. By the comparison of the threshold value and the force on the fingertip of the exoskeleton from the sensor, the automatic switch between active and passive rehabilitation mode is accomplished. The hand model is built in Android environment that can synchronize the movement of the hand. It can also induce patients to participate in rehabilitation training actively. To verify the proposed control approach, we set up and conduct an experiment to do the passive rehabilitation mode, active rehabilitation mode, and active plus passive mode experimental researches. The experiment results effectively verify the feasibility of the exoskeleton system fulfilling the proposed control strategy.