Johan S. van Den Brink
Research Subjects
Johan S. van Den Brink has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Alexander Y. Pogromsky
Eindhoven University of Technology
1 shared publication- Andrew G. Webb
C. J. Gorter MRI Centre, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
1 shared publication Celso Matos
Department of Radiology, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium
1 shared publicationChristiane K Kuhl
Department of Radiology, University of Bonn, Bonn, Germany
1 shared publication- Dennis M. J. van de Sande
Department of Biomedical Engineering Eindhoven University of Technology Eindhoven The Netherlands
1 shared publication - Evgeniy N. Ivanov
Eindhoven University of Technology
1 shared publication
Latest Publications
- Open Access
- 4 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1253-1270
A review of machine learning applications for the proton MR spectroscopy workflow
This literature review presents a comprehensive overview of machine learning (ML) applications in proton MR spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state‐of‐the‐art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the MR field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field.
- 4 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1253-1270
Open AccessA review of machine learning applications for the proton MR spectroscopy workflow
This literature review presents a comprehensive overview of machine learning (ML) applications in proton MR spectroscopy (MRS). As the use of ML techniques in MRS continues to grow, this review aims to provide the MRS community with a structured overview of the state‐of‐the‐art methods. Specifically, we examine and summarize studies published between 2017 and 2023 from major journals in the MR field. We categorize these studies based on a typical MRS workflow, including data acquisition, processing, analysis, and artificial data generation. Our review reveals that ML in MRS is still in its early stages, with a primary focus on processing and analysis techniques, and less attention given to data acquisition. We also found that many studies use similar model architectures, with little comparison to alternative architectures. Additionally, the generation of artificial data is a crucial topic, with no consistent method for its generation. Furthermore, many studies demonstrate that artificial data suffers from generalization issues when tested on in vivo data. We also conclude that risks related to ML models should be addressed, particularly for clinical applications. Therefore, output uncertainty measures and model biases are critical to investigate. Nonetheless, the rapid development of ML in MRS and the promising results from the reviewed studies justify further research in this field.
- Open Access
- 17 June 2019
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 2019, 1-17
Thermal Effects Associated with RF Exposures in Diagnostic MRI: Overview of Existing and Emerging Concepts of Protection
Apart from magnetic attraction risks, the primary biophysical concern associated with MRI is radiofrequency heating of the human body and associated discomfort, health deterioration, or potential burns. This paper reviews experimental data and numerical modeling of systemic (core and brain) temperature and local thermal effects associated with diagnostic MRI exposures at 1.5T (64 MHz) and 3.0T (128 MHz). Allowable temperatures and duration of systemic exposure are established based on knowledge of (short-term) human thermobiology. Longer term effects related to DNA damage or altered cellular pathways are not covered in this review. Updated limits are proposed for core temperature increase (≤1.3°C) and for Specific Absorption (<4 kJ/kg). The potential use of thermal dose (CEM43) for local thermal protection is described, and previously proposed exposure limit values are evaluated against available data from current MRI practice. Gaps in knowledge are identified, and recommendations for additional research are provided.
- 17 June 2019
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 2019, 1-17
Open AccessThermal Effects Associated with RF Exposures in Diagnostic MRI: Overview of Existing and Emerging Concepts of Protection
Apart from magnetic attraction risks, the primary biophysical concern associated with MRI is radiofrequency heating of the human body and associated discomfort, health deterioration, or potential burns. This paper reviews experimental data and numerical modeling of systemic (core and brain) temperature and local thermal effects associated with diagnostic MRI exposures at 1.5T (64 MHz) and 3.0T (128 MHz). Allowable temperatures and duration of systemic exposure are established based on knowledge of (short-term) human thermobiology. Longer term effects related to DNA damage or altered cellular pathways are not covered in this review. Updated limits are proposed for core temperature increase (≤1.3°C) and for Specific Absorption (<4 kJ/kg). The potential use of thermal dose (CEM43) for local thermal protection is described, and previously proposed exposure limit values are evaluated against available data from current MRI practice. Gaps in knowledge are identified, and recommendations for additional research are provided.
- Open Access
- 26 May 2019
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 2019, 1-8
Inherent Geometry Correction for Diffusion EPI Using the Reference Echoes as Navigators
Diffusion-weighted EPI has become an indispensable tool in body MRI. Geometric distortions due to field inhomogeneities are more prominent at large field–of–view and require correction for comparison with T2W TSE. Several known correction methods require acquisition of additional lengthy scans, which are difficult to apply in body imaging. We implement and evaluate a geometry correction method based on the already available non phase-encoded EPI reference data used for Nyquist ghost removal. The method is shown to provide accurate and robust global geometry correction in the absence of strong, local phase offsets. It does not require additional time for calibrations and is directly compatible with parallel imaging methods. The resulting images can serve as improved starting point for additional geometry correction methods relying on feature extraction and registration.
- 26 May 2019
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 2019, 1-8
Open AccessInherent Geometry Correction for Diffusion EPI Using the Reference Echoes as Navigators
Diffusion-weighted EPI has become an indispensable tool in body MRI. Geometric distortions due to field inhomogeneities are more prominent at large field–of–view and require correction for comparison with T2W TSE. Several known correction methods require acquisition of additional lengthy scans, which are difficult to apply in body imaging. We implement and evaluate a geometry correction method based on the already available non phase-encoded EPI reference data used for Nyquist ghost removal. The method is shown to provide accurate and robust global geometry correction in the absence of strong, local phase offsets. It does not require additional time for calibrations and is directly compatible with parallel imaging methods. The resulting images can serve as improved starting point for additional geometry correction methods relying on feature extraction and registration.
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 82
The effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 82
Open AccessThe effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T
- 22 September 2010
- Published by Springer Nature
- p. 227-243
Scheduling in MRI Scans processing
- 1 April 2003
- Published by Elsevier in European Journal of Radiology
- Vol. 46 (1) , 3-27
Implications of SENSE MR in routine clinical practice
- 1 April 2003
- Published by Elsevier in European Journal of Radiology
- Vol. 46 (1) , 3-27
Implications of SENSE MR in routine clinical practice