Maxim Pyrysunko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maxim Pyrysunko has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mykola Radchenko
Admiral Makarov National University of Shipbuilding, Heroes of Ukraine Avenue 9, 54025 Mykolaiv, Ukraine
8 shared publications - Victoria Kornienko
Admiral Makarov National University of Shipbuilding
7 shared publications - Andrii Andreev
Department of Air Conditioning and Refrigeration, Admiral Makarov National University of Shipbuilding, Heroes of Ukraine Avenue 9, 54025 Mykolaiv, Ukraine
4 shared publications - Dmytro Konovalov
Department of Energy and Process Engineering, Norwegian University of Science and Technology, Kolbjørn Hejes vei 1, 7034 Trondheim, Norway
4 shared publications - Andrii Radchenko
Admiral Makarov National University of Shipbuilding, Heroes of Ukraine Avenue 9, 54025 Mykolaiv, Ukraine
2 shared publications - Halina Kobalava
Admiral Makarov National University of Shipbuilding
2 shared publications
Latest Publications
- 6 July 2024
- Published by Springer Nature
- p. 241-252
Study of Thermophysical Processes in the Thermopressor for Contact Cooling Systems
- 6 July 2024
- Published by Springer Nature
- p. 241-252
Study of Thermophysical Processes in the Thermopressor for Contact Cooling Systems
- Open Access
- 4 July 2023
- Published by Odessa National Maritime University in Transport development
- No. 2(17),p. 29-41
ПЕРСПЕКТИВНІ НАПРЯМИ ОХОЛОДЖЕННЯ НАДДУВНОГО ПОВІТРЯ СУДНОВИХ МАЛООБЕРТОВИХ ДИЗЕЛІВ З УТИЛІЗАЦІЄЮ ВТОРИННОЇ ТЕПЛОТИ
Introduction. Structurally, the most simple and reliable in operation is the heatusing cooling system (HUCS) of the ejector-type for supercharged air (EHUCS), in which the function of the compressor is performed by the ejector, and the integration of which into the regular turbocharging system of ship low-speed engines (LSE) does not lead to a noticeable complication of the latter. However, the thermodynamic efficiency of EHUCS (thermal coefficients ζ) is less than that of more complex and bulky, for example, absorption cooling systems (AHUCS). Therefore, if, due to the need to remove a large amount of heat from the supercharged air, caused by insufficiently high ζ EHUCS, the heat exchange surface of the heat-using stages of the air-cooler, and, accordingly, their aerodynamic resistances turn out to be significant, it will be necessary to use thermodynamically more efficient HUCS, for example, AHUCS or an intermediate stage of cooling air with seawater. It is also possible to use additional sources of heat, in particular exhaust gases or engine cooling water, the removal of heat from which is not related to the placement of heat exchange units in the air or gas exhaust tracts and, therefore, does not lead to an additional increase in aerodynamic resistance. On the basis of the above premises, the HUCS of supercharged air of ship LSEs was developed and analyzed. Purpose: the use of low-boiling working bodies (LBB) in HUCS allows to cool the water of the intermediate water circuit of supercharged air cooling to low temperatures, close to 0ºС, and without the need to maintain a vacuum in the evaporator of LBB-water coolers. Results: a three-stage, three-circuit supercharged air cooling system is proposed, in which the presence of an intermediate stage of supercharged air cooling with water (regular air-cooler) allows to compensate for the deficit of high potential heat of air for EHUCS and, accordingly, cooling capacity, and therefore leads to a reduction of the surface of the air-cooler, primarily its economizer (tail, in the direction of the air) section, respectively, and the aerodynamic resistance, which is Р < 3000 Pa, that is, less than 1 % of the supercharged air pressure Рк . Conclusions: the presence of an intermediate degree of cooling of supercharged air with seawater makes the three-stage three-circuit cooling system practically independent of the temperature of the seawater, and in terms of the efficiency (depth) of air cooling it exceeds the two-stage three-circuit cooling system.
- 4 July 2023
- Published by Odessa National Maritime University in Transport development
- No. 2(17),p. 29-41
Open AccessПЕРСПЕКТИВНІ НАПРЯМИ ОХОЛОДЖЕННЯ НАДДУВНОГО ПОВІТРЯ СУДНОВИХ МАЛООБЕРТОВИХ ДИЗЕЛІВ З УТИЛІЗАЦІЄЮ ВТОРИННОЇ ТЕПЛОТИ
Introduction. Structurally, the most simple and reliable in operation is the heatusing cooling system (HUCS) of the ejector-type for supercharged air (EHUCS), in which the function of the compressor is performed by the ejector, and the integration of which into the regular turbocharging system of ship low-speed engines (LSE) does not lead to a noticeable complication of the latter. However, the thermodynamic efficiency of EHUCS (thermal coefficients ζ) is less than that of more complex and bulky, for example, absorption cooling systems (AHUCS). Therefore, if, due to the need to remove a large amount of heat from the supercharged air, caused by insufficiently high ζ EHUCS, the heat exchange surface of the heat-using stages of the air-cooler, and, accordingly, their aerodynamic resistances turn out to be significant, it will be necessary to use thermodynamically more efficient HUCS, for example, AHUCS or an intermediate stage of cooling air with seawater. It is also possible to use additional sources of heat, in particular exhaust gases or engine cooling water, the removal of heat from which is not related to the placement of heat exchange units in the air or gas exhaust tracts and, therefore, does not lead to an additional increase in aerodynamic resistance. On the basis of the above premises, the HUCS of supercharged air of ship LSEs was developed and analyzed. Purpose: the use of low-boiling working bodies (LBB) in HUCS allows to cool the water of the intermediate water circuit of supercharged air cooling to low temperatures, close to 0ºС, and without the need to maintain a vacuum in the evaporator of LBB-water coolers. Results: a three-stage, three-circuit supercharged air cooling system is proposed, in which the presence of an intermediate stage of supercharged air cooling with water (regular air-cooler) allows to compensate for the deficit of high potential heat of air for EHUCS and, accordingly, cooling capacity, and therefore leads to a reduction of the surface of the air-cooler, primarily its economizer (tail, in the direction of the air) section, respectively, and the aerodynamic resistance, which is Р < 3000 Pa, that is, less than 1 % of the supercharged air pressure Рк . Conclusions: the presence of an intermediate degree of cooling of supercharged air with seawater makes the three-stage three-circuit cooling system practically independent of the temperature of the seawater, and in terms of the efficiency (depth) of air cooling it exceeds the two-stage three-circuit cooling system.
- 25 May 2022
- Published by Springer Nature
- p. 259-268
Marine Diesel Engine Inlet Air Cooling by Ejector Chiller on the Vessel Route Line
- 25 May 2022
- Published by Springer Nature
- p. 259-268
Marine Diesel Engine Inlet Air Cooling by Ejector Chiller on the Vessel Route Line
- 1 January 2022
- Published by Springer Nature
- p. 509-519
Effect of Utilization Exhaust and Recirculation Gases of Ship Diesel Engine in Absorption Chiller
- 1 January 2022
- Published by Springer Nature
- p. 509-519
Effect of Utilization Exhaust and Recirculation Gases of Ship Diesel Engine in Absorption Chiller
- 1 January 2022
- Published by Springer Nature
- p. 474-483
Increasing Ecological and Energy Efficiency of Combustion Engines by Using a Thermopressor
- 1 January 2022
- Published by Springer Nature
- p. 474-483
Increasing Ecological and Energy Efficiency of Combustion Engines by Using a Thermopressor
- 29 May 2021
- Published by Springer Nature
- p. 391-400
Enhancing Energy Efficiency of Ship Diesel Engine with Gas Ecological Recirculation
- 29 May 2021
- Published by Springer Nature
- p. 391-400
Enhancing Energy Efficiency of Ship Diesel Engine with Gas Ecological Recirculation
- 5 February 2021
- Published by Springer Nature
- p. 664-674
Improvement of Characteristics of Water-Fuel Rotary Cup Atomizer in a Boiler
- 5 February 2021
- Published by Springer Nature
- p. 664-674
Improvement of Characteristics of Water-Fuel Rotary Cup Atomizer in a Boiler
- 5 February 2021
- Published by Springer Nature
- p. 734-743
Ship Engine Intake Air Cooling by Ejector Chiller Using Recirculation Gas Heat
- 5 February 2021
- Published by Springer Nature
- p. 734-743
Ship Engine Intake Air Cooling by Ejector Chiller Using Recirculation Gas Heat