CACollin R. Anderson

Collin R. Anderson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Collin R. Anderson has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Mark MacKay

    Primary Children's Hospital, Salt Lake City, Utah

    2 shared publications
  • Sabrina Boehme

    Department of Pharmacy, Primary Children's Hospital, Salt Lake City, UT

    2 shared publications
  • Angela Wolsey

    Department of Pharmacy, Primary Children's Hospital, Salt Lake City, UT

    1 shared publication
  • Brent A. Kay

    Pediatric Intensive Care Unit, Primary Children’s Medical Center, Salt Lake City, UT

    1 shared publication
  • Chanelle Stidham

    Pharmacy Team Lead, Pediatric Intensive Care Unit/Neuroscience Trauma Unit, Primary Children's Hospital

    1 shared publication
  • Daniel Jackson

    University of Utah Health, Salt Lake City, UT, USA

    1 shared publication

Latest Publications

  • Calcium and Phosphate Solubility Curve Equation for Determining Precipitation Limits in Compounding Parenteral Nutrition

    by Collin Anderson, Larry Eggert, Kristie Fitzgerald, Daniel Jackson, Fred Farr

    Clinicians have published research and reports on calcium and phosphate solubility within parenteral nutrition (PN) for over 40 years. Foundational empirical laboratory investigation in the 1980s motivated by the prevalence of neonatal rickets and osteomalacia in the Neonatal Intensive Care Unit (NICU) population led to precipitation curves that have guided PN prescribing and compounding. Over subsequent decades, numerous publications have expanded the knowledge of factors influencing calcium and phosphate solubility in formulating optimal and safe PN admixtures. Failure to adhere to known principles has led to serious injury and death. Known solubility curves are derived from empiric analysis of a finite number of conditions and concentrations, whereas custom PN orders vary widely and rarely match the admixture composition in the data set used to derive the published precipitation curves. Various commercial platforms have been developed to aid the pharmacist in assessing the potential for precipitation when evaluating a PN order. Some applications plot the calcium and phosphate concentrations of the prescribed PN against known published graphs most similar to the order, allowing the pharmacist to judge the risk of precipitation. Other approaches use intellectually protected trade secret algorithms to determine calcium and phosphate solubility across a continuum of conditions. This publication reports equations that have been used successfully for over 2 decades in our regional network of NICUs and shared with others to determine safe prescribing limits for calcium and phosphate concentrations using an electronic PN prescribing program.


  • Retrospective comparison of two enoxaparin dosing and monitoring protocols at a pediatric hospital

    by Angela Wolsey, Roger A Wilcox, Jared A Olson, Sabrina Boehme, Collin R Anderson

    The study analyzes the effectiveness and safety of a higher than standard enoxaparin dosing protocol implemented for pediatric patients requiring initiation of therapeutic anticoagulation. A retrospective review of 2 enoxaparin dosing and monitoring protocols was performed. The standard protocol used 1.5 mg/kg/dose (in patients n = 87) and high-dose groups (n = 132) (p = 0.17), respectively. The median number of dose adjustments to achieve target anti-Xa levels in the 3 through 11 months of age subgroup declined from 2 (IQR, 1–3.25) to 0 (IQR, 0–1) in the standard- versus high-dose groups, respectively (p < 0.01). No difference was seen in other age subgroups. Patients with above-target levels did not differ statistically between groups. Initiating enoxaparin at higher doses in pediatric patients may result in fewer dosing changes than standard dosing. Benefit was demonstrated for the 3–11 months of age high-dose subgroup. Across all groups, the high-dose strategy was safe and did not result in a statistically significant increase in above-target levels.


  • Open Access

    Influencing the timing of parenteral nutrition initiation in the pediatric intensive care unit

    by Collin R. Anderson, Jennifer Lueckler, Jared A. Olson

    Pharmacy Practice is a free full-text journal with a scope on the practice of pharmacy. Pharmacy Practice covers pharmaceutical care, social pharmacy, pharmacy education, process and outcome research, health promotion and education, health informatics, pharmacoepidemiology


    • 1 January 2016
      • Vol. 20  (5) , 435-437

    Stability of Sodium Nitroprusside in 5% Dextrose Stored at 4°C in Polypropylene Syringes Protected from Light.

    by Collin R Anderson, Deborah Collins, Trevor Laursen, Trevor Arave, Michael Helm

    Sodium nitroprusside is a potent vasodilator employed intraoperatively and within critical care areas. The photolabile pharmaceutical agent has been used for decades and various stability studies have been executed. Due to potential shortages and the desire to batch compound sodium nitroprusside at a concentration of 1 mg/mL in polypropylene syringes, a new stability study was performed. Chromatographic analysis was conducted on a C18 column, with elution via an aqueous phase of 0.01 M sodium phosphate monobasic, adjusted to pH 6.5 with sodium hydroxide, and methanol (97.5:2.5) at a rate of 1 mL/min, and subsequent ultraviolet detection at 210 nm. Triplicate determinations of four samples, stored under refrigeration at 4°C, were obtained initially and on days 2, 5, and 9. Turbidity and pH measurements were performed in conjunction with visual observation on days of chromatographic analysis. Results demonstrate that sodium nitroprusside compounded in 5% dextrose at a concentration of 1 mg/mL, stored at 4°C protected from light in polypropylene syringes, is physically and chemically stable for at least 9 days.

  • Open Access

    Stability of Fentanyl Citrate, Hydromorphone Hydrochloride, Ketamine Hydrochloride, Midazolam, Morphine Sulfate, and Pentobarbital Sodium in Polypropylene Syringes

    by Collin Anderson, Mark MacKay

    Purpose: Determine the stability of fentanyl 10 mcg/mL in 0.9% sodium chloride, fentanyl 10 mcg/mL in 5% dextrose, fentanyl 50 mcg/mL, hydromorphone 100 mcg/mL in 0.9% sodium chloride, ketamine 10 mg/mL, midazolam 0.4 mg/mL in 5% dextrose, midazolam 5 mg/mL, morphine 1 mg/mL in 0.9% sodium chloride, morphine 1 mg/mL in 5% dextrose, and pentobarbital 50 mg/mL when stored as single drug entities at room temperature in polypropylene syringes. Methods: Four 5 mL samples of each drug and concentration were prepared in 10 mL polypropylene syringes. The samples were stored at ambient room temperature in a locked cabinet. Triplicate determinations of drug concentration for each sample were performed initially, on day 50 or 51, and on day 100 using high-performance liquid chromatography with diode-array detection. Results: With the exception of the hydromorphone 100 mcg/mL dilution, all compounds were found to contain greater than 95% of their initial concentration remaining at 100 days. Each sample remained clear and colorless when visually inspected.


  • Physical Compatibility of Calcium Chloride and Sodium Glycerophosphate in Pediatric Parenteral Nutrition Solutions

    by Collin Anderson, Mark MacKay

    Background: Calcium and phosphate precipitation is an ongoing concern when compounding pediatric parenteral nutrition (PN) solutions. Considerable effort has been expended in producing graphs, tables, and equations to guide the practitioner in prescribing PN that will remain stable. Calcium gluconate is preferred over calcium chloride when compounding PN because of its superior compatibility with inorganic phosphates. PN solutions containing calcium gluconate carry a higher aluminum load than equivalent solutions compounded with calcium chloride, leading to increased potential for aluminum toxicity. This study tested the solubility of calcium chloride in PN solutions compounded with an organic phosphate component, sodium glycerophosphate (NaGP), in place of sodium phosphate. Methods: Five PN solutions were compounded by adding calcium chloride at 10, 20, 30, 40, and 50 mEq/L and corresponding concentrations of NaGP at 10, 20, 30, 40, and 50 mmol/L. Each of the 5 solutions was compounded using 1.5% and 4% amino acids, cysteine, and lipids. The physical stability was evaluated by visual inspection (precipitation, haze, and color change). Solutions were evaluated microscopically for any microcrystals using U.S. Pharmacopeia standards. Results: Compatibility testing showed no changes in the PN solution in any of the concentrations tested. Calcium chloride was found to be physically compatible with NaGP in PN at the tested concentrations. Conclusion: Utilization of NaGP in PN solutions would eliminate the need for precipitation curves and allow for the use of calcium chloride. Compounding with NaGP and calcium chloride allows the practitioner a mechanism for reducing the aluminum load in PN.


  • Correlation of weight-based i.v. immune globulin doses with changes in serum immunoglobulin G levels

    by Collin R. Anderson, Jared A. Olson

    Correlations between the i.v. immune globulin (IVIG) dose and the change in serum immunoglobulin G (IgG) concentration with three methods of weight-based dosing were investigated. A retrospective medical records review was conducted to identify patients in a multicenter healthcare system who received IVIG over a 10-year period and had serum IgG measurements within two days before and two days after the date of IVIG administration. For each of the 11 adults and 7 adolescents identified, the relationship between the weight-based dose of IVIG (determined using actual body weight [BW], adjusted BW, or ideal BW [IBW]) and the resulting change in serum IgG was evaluated. Correlation coefficients and corresponding p values for the three dosing methods were calculated and compared. Among adult patients, the correlation of IVIG dose and postdose change in serum IgG was strongest with dosing by IBW (correlation coefficient [r], 0.83 [p < 0.05] versus r values of 0.73 and 0.70 for dosing by adjusted BW or actual BW, respectively [p = 0.05 for both]); the corresponding r values in adolescent patients were 0.99, 0.99, and 0.95, respectively (p < 0.005 for all). There were no statistically significant differences between the r values calculated for the three weight-based dosing methods in either adults or adolescents. In adult patients, the correlation between the dose of IVIG and the change in IgG level was strongest when doses were calculated using IBW; comparable degrees of correlation were observed with the three evaluated methods of weight-based dosing in the adolescent population.


  • Physical and Chemical Compatibility of Injectable Acetaminophen during Simulated Y-Site Administration

    by Collin Anderson, Sabrina Boehme, Jacquelyn Ouellette, Chanelle Stidham, Mark MacKay

    Purpose: The physical and chemical compatibility of intravenous acetaminophen with commonly administered injectable medications was evaluated. Methods: Simulated Y-site evaluation was accomplished by mixing 2 mL of acetaminophen (10 mg/mL) with 2 mL of an alternative intravenous medication and subsequently storing the mixture in a polypropylene syringe for 4 hours. The aliquot solutions were visually inspected and evaluated for crystal content at 4 hours by infusing 4 mL of the medication mixture through a 0.45-μm nitrocellulose filter disc. Medication mixtures that were selected for chemical stability testing were analyzed by high-performance liquid chromatography at 0, 1, and 4 hours using a Zorbax Eclipse Plus C18, 4.6 × 100 mm, 3.5-μm column for separation of analytes with subsequent diode-array detection. Medications were considered chemically compatible if the concentrations of all components were >90% of the original concentrations during the 4 hour simulated Y-site compatibility test. Results: U.S. Pharmacopeial Convention (USP) standards for physical particle counts were met for acetaminophen injection (10 mg/mL) when combined with cefoxitin, ceftriaxone, clindamycin, dexamethasone, diphenhydramine, dolasetron, fentanyl, granisetron, hydrocortisone, hydromorphone, ketorolac, meperidine, methylprednisolone, midazolam, morphine, nalbuphine, ondansetron, piperacillin/tazobactam, ranitidine, and vancomycin. Injectable acetaminophen is incompatible with acyclovir and diazepam and therefore should not be administered concomitantly with either of these products. Further testing confirmed the chemical compatibility of acetaminophen with ceftriaxone, diphenhydramine, granisetron, ketorolac, nalbuphine, ondansetron, piperacillin/tazobactam, and vancomycin. Conclusion: All medications tested with acetaminophen were physically compatible except for acyclovir and diazepam. All 8 medications tested for chemical compatibility with acetaminophen were stable over the 4 hour simulated Y-site administration study.


  • Stability of dexmedetomidine 4 μg/mL in polypropylene syringes

    by Collin R. Anderson, Mark W. Mackay, Marc Holley, Brent A. Kay

    The results of a study to determine the long-term (up to 14 days) stability of diluted dexmedetomidine kept in polypropylene syringes under typical pharmacy storage conditions are presented.