Yujie Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yujie Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Qi Yu
Department of Environmental Science and Engineering, Fudan University, Shanghai 200438, China
3 shared publications - Weichun Ma
Department of Environmental Science and Engineering, Fudan University, Shanghai, China
3 shared publications - Zihan Huang
Department of Environmental Science and Engineering, Fudan University, Shanghai 200438, China
3 shared publications - Limin Chen
Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention (LAP3), Department of Environmental Science and Engineering, Fudan University, Shanghai 200438, China
1 shared publication - Yan Zhang
Fudan University
1 shared publication - Yuan Wang
Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China
1 shared publication
Latest Publications
- Open Access
- 11 June 2019
- Published by MDPI AG in Atmosphere
- Vol. 10 (6) , 318
Optimal Design of Air Quality Monitoring Network for Pollution Detection and Source Identification in Industrial Parks
Dense air quality monitoring network (AQMN) is one of main ways to surveil industrial air pollution. This paper is concerned with the design of a dense AQMN for H2S for a chemical industrial park in Shanghai, China. An indicator (Surveillance Efficiency, SE) for the long-term performance of AQMN was constructed by averaging pollution detection efficiency (rd) and source identification efficiency (rb). A ranking method was developed by combing Gaussian puff model and Source area analysis for improving calculation efficiency. Candidate combinations with highest score were given priority in the selection of next site. Two existing monitors were suggested to relocate to the west and southwest of this park. SE of optimized AQMN increased quickly with monitor number, and then the growth trend started to flatten when the number reached about 60. The highest SE occurred when the number reached 110. Optimal schemes of AQMNs were suggested which can achieve about 98% of the highest SE, while using only about 60 monitors. Finally, the reason why the highest SE is less than 1 and the variation characteristics of rd and rb were discussed. Overall, the proposed method is an effective tool for designing AQMN with optimal SE in industrial parks.
- 11 June 2019
- Published by MDPI AG in Atmosphere
- Vol. 10 (6) , 318
Open AccessOptimal Design of Air Quality Monitoring Network for Pollution Detection and Source Identification in Industrial Parks
Dense air quality monitoring network (AQMN) is one of main ways to surveil industrial air pollution. This paper is concerned with the design of a dense AQMN for H2S for a chemical industrial park in Shanghai, China. An indicator (Surveillance Efficiency, SE) for the long-term performance of AQMN was constructed by averaging pollution detection efficiency (rd) and source identification efficiency (rb). A ranking method was developed by combing Gaussian puff model and Source area analysis for improving calculation efficiency. Candidate combinations with highest score were given priority in the selection of next site. Two existing monitors were suggested to relocate to the west and southwest of this park. SE of optimized AQMN increased quickly with monitor number, and then the growth trend started to flatten when the number reached about 60. The highest SE occurred when the number reached 110. Optimal schemes of AQMNs were suggested which can achieve about 98% of the highest SE, while using only about 60 monitors. Finally, the reason why the highest SE is less than 1 and the variation characteristics of rd and rb were discussed. Overall, the proposed method is an effective tool for designing AQMN with optimal SE in industrial parks.
- Open Access
- 17 December 2018
- Published by MDPI AG in Atmosphere
- Vol. 9 (12) , 501
Identifying Key Potential Source Areas for Ambient Methyl Mercaptan Pollution Based on Long-Term Environmental Monitoring Data in an Industrial Park
Precise source identification for ambient pollution incidents in industrial parks were often difficult due to limited measurements. Source area analysis method was one of the applicable source identification methods, which could provide potential source areas under these circumstances. However, a source area usually covered several sources and the method was unable to identify the real one. This article introduces a case study on the statistical source identification of methyl mercaptan based on the long-term measurements, in 2014, in an industrial park. A procedure for statistical source area analysis was established, which contains independent pollution episode extraction, source area calculation scenario definition, meteorological data selection, and source area statistical analysis. A total of 414 violation records were detected by five monitors inside the park. Three kinds of calculation scenarios were found and, finally, three key source areas were revealed. The typical scenarios of source area calculations were described in detail. The characteristics of the statistical source areas for all pollution episodes were examined. Finally, the applicability of the method, as well as the source of uncertainties, was discussed. This study shows that more concentrated source areas can be identified through the statistical source area method if several excessive emission sources exist in an industrial park.
- 17 December 2018
- Published by MDPI AG in Atmosphere
- Vol. 9 (12) , 501
Open AccessIdentifying Key Potential Source Areas for Ambient Methyl Mercaptan Pollution Based on Long-Term Environmental Monitoring Data in an Industrial Park
Precise source identification for ambient pollution incidents in industrial parks were often difficult due to limited measurements. Source area analysis method was one of the applicable source identification methods, which could provide potential source areas under these circumstances. However, a source area usually covered several sources and the method was unable to identify the real one. This article introduces a case study on the statistical source identification of methyl mercaptan based on the long-term measurements, in 2014, in an industrial park. A procedure for statistical source area analysis was established, which contains independent pollution episode extraction, source area calculation scenario definition, meteorological data selection, and source area statistical analysis. A total of 414 violation records were detected by five monitors inside the park. Three kinds of calculation scenarios were found and, finally, three key source areas were revealed. The typical scenarios of source area calculations were described in detail. The characteristics of the statistical source areas for all pollution episodes were examined. Finally, the applicability of the method, as well as the source of uncertainties, was discussed. This study shows that more concentrated source areas can be identified through the statistical source area method if several excessive emission sources exist in an industrial park.
- Open Access
- 2 June 2017
- Published by MDPI AG in Atmosphere
- Vol. 8 (6) , 99
Back-Calculation of Traffic-Related PM10 Emission Factors Based on Roadside Concentration Measurements
Many researchers have failed to utilize back-calculation to estimate traffic emissions effectively or have obtained unclear results. In this study, the back-calculation of traffic-related PM10 emission factors based on roadside concentration measurements was analyzed. Experimental conditions were considered to ensure the success of back-calculation. Roadside measurements were taken in a street canyon in Shanghai, China. Concentrations from a background site were often found to exceed the measured concentrations at the roadside on polluted days as more errors occurred in the background concentrations. On clean days, these impacts were negligible. Thus, only samples collected on clean days were used in back-calculation. The mean value from back-calculation was 0.138 g/km, which was much smaller than the results obtained using official emission models. Emission factors for light-duty vehicles (LDV), medium-duty vehicles (MDV), heavy-duty vehicles (HDV), and motorcycles were approximately 0.121, 0.427, 0.445, and 0.096 g/km, respectively. The fleet-averaged non-exhaust emission factor was approximately 0.121 g/km, indicating that road dust accounted for 87.7% of the roadside concentration increments. According to the dispersion simulation of reserved samples, the concentrations simulated using back-calculated emission factors were in better agreement with the measured data than the concentrations derived using modeled emission factors.
- 2 June 2017
- Published by MDPI AG in Atmosphere
- Vol. 8 (6) , 99
Open AccessBack-Calculation of Traffic-Related PM10 Emission Factors Based on Roadside Concentration Measurements
Many researchers have failed to utilize back-calculation to estimate traffic emissions effectively or have obtained unclear results. In this study, the back-calculation of traffic-related PM10 emission factors based on roadside concentration measurements was analyzed. Experimental conditions were considered to ensure the success of back-calculation. Roadside measurements were taken in a street canyon in Shanghai, China. Concentrations from a background site were often found to exceed the measured concentrations at the roadside on polluted days as more errors occurred in the background concentrations. On clean days, these impacts were negligible. Thus, only samples collected on clean days were used in back-calculation. The mean value from back-calculation was 0.138 g/km, which was much smaller than the results obtained using official emission models. Emission factors for light-duty vehicles (LDV), medium-duty vehicles (MDV), heavy-duty vehicles (HDV), and motorcycles were approximately 0.121, 0.427, 0.445, and 0.096 g/km, respectively. The fleet-averaged non-exhaust emission factor was approximately 0.121 g/km, indicating that road dust accounted for 87.7% of the roadside concentration increments. According to the dispersion simulation of reserved samples, the concentrations simulated using back-calculated emission factors were in better agreement with the measured data than the concentrations derived using modeled emission factors.