Guillaume Bucher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guillaume Bucher has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Douglas Gilliland
European Commission, Joint Research Centre (JRC), 21027 Ispra, Italy
5 shared publications - Dora Mehn
European Commission, Joint Research Centre (JRC), 21027 Ispra, Italy
4 shared publications - Gabriella F. Schirinzi
European Commission, Joint Research Centre (JRC), 21027 Ispra, Italy
4 shared publications - Jessica Ponti
European Commission, Joint Research Centre (JRC), 21027 Ispra, Italy
3 shared publications - Marisa Passos Sárria
Institute of Biotechnology, RWTH Aachen University, Aachen, Germany, Germany
3 shared publications - Amaia Orbea
CBET+ Research Group, Department Zoology and Animal Cell Biology, Faculty of Science and Technology and Research Centre for Experimental Marine Biology and Biotechnology PiE, Univeristy of the Basque Country EHU, Leioa, Spain, Spain
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by MDPI AG in Preprints.org
Gene Transcription Levels in Acartia tonsa Exposed to Waterborne or Foodborne Nanoplastics of Different Size and Composition
The widespread presence of nanoplastics (NPs) of different sizes and polymer compositions in aquatic ecosystems has raised increasing concern. Yet, their quantification remains difficult due to analytical limitations. Metal-doped model NPs offer a useful approach in toxicological studies enabling more quantitative assessment of NPs occurrence in organisms. This study provides a novel link between quantitative NP uptake and their transcriptomic effects in Acartia tonsa, highlighting the influence of polymer composition and exposure route. This study examined transcriptional responses in the marine copepod following both waterborne and foodborne exposure to NPs of varying sizes and polymer types, including polystyrene (PS) with and without a palladium tracer (Pd-doped PS and PS) as well as gold-doped polyvinyl chloride (Au-doped PVC), polypropylene (Au-doped PP) and polyethylene (Au-doped PE) NPs. Accumulation of Pd or Au was measured as a proxy of NPs in microalgae, copepods and their feces. All studied NPs were found in the feces. In exposed copepods, Pd-doped PS NPs showed the highest accumulation within organisms, followed by Au-doped PP NPs. These differences in accumulation may be influenced by the physicochemical properties of the NPs. The presence of Au/Pd-doped PS NPs in copepods and the routes of exposure were linked to alterations of transcription levels of general and oxidative stress genes. In contrast, non-doped PS NPs of different sizes did not affect the transcription levels of the selected genes. Overall, this study demonstrates that NP accumulation and excretion, as well as the molecular mechanisms regulated in A. tonsa, vary depending on NP polymer chemistry as well as on the exposure route.
- 7 October 2026
- Published by MDPI AG in Preprints.org
Open AccessGene Transcription Levels in Acartia tonsa Exposed to Waterborne or Foodborne Nanoplastics of Different Size and Composition
The widespread presence of nanoplastics (NPs) of different sizes and polymer compositions in aquatic ecosystems has raised increasing concern. Yet, their quantification remains difficult due to analytical limitations. Metal-doped model NPs offer a useful approach in toxicological studies enabling more quantitative assessment of NPs occurrence in organisms. This study provides a novel link between quantitative NP uptake and their transcriptomic effects in Acartia tonsa, highlighting the influence of polymer composition and exposure route. This study examined transcriptional responses in the marine copepod following both waterborne and foodborne exposure to NPs of varying sizes and polymer types, including polystyrene (PS) with and without a palladium tracer (Pd-doped PS and PS) as well as gold-doped polyvinyl chloride (Au-doped PVC), polypropylene (Au-doped PP) and polyethylene (Au-doped PE) NPs. Accumulation of Pd or Au was measured as a proxy of NPs in microalgae, copepods and their feces. All studied NPs were found in the feces. In exposed copepods, Pd-doped PS NPs showed the highest accumulation within organisms, followed by Au-doped PP NPs. These differences in accumulation may be influenced by the physicochemical properties of the NPs. The presence of Au/Pd-doped PS NPs in copepods and the routes of exposure were linked to alterations of transcription levels of general and oxidative stress genes. In contrast, non-doped PS NPs of different sizes did not affect the transcription levels of the selected genes. Overall, this study demonstrates that NP accumulation and excretion, as well as the molecular mechanisms regulated in A. tonsa, vary depending on NP polymer chemistry as well as on the exposure route.
- Open Access
- 10 September 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (18) , 1133
Distribution and Effects of Model Palladium-Doped Nanoplastics in the Marine Mussel Mytilus galloprovincialis
While nanoplastics (NPs, Mytilus galloprovincialis. For this, mussels were dietarily exposed for 7 days to model palladium-doped-polystyrene NPs (Pd-PS NPs) of 142.6 ± 1.0 nm at 1 × 109 Pd-PS NPs/mL. ICP-MS analysis on water samples showed that after one day of exposure no Pd was detected suggesting that mussels cleared the NPs. After 7 days of exposure, 14% of the Pd introduced in the tanks was found in feces. Less than 0.02% passed into the hemolymph of mussels and consequently, no responses were observed on hemocytes. Approximately 1% of the Pd was found in soft tissues. This could be linked to the significantly higher prevalence of digestive tubule atrophy observed in exposed mussels in comparison to controls. No effects were observed at the whole organism level. In conclusion, mussels were able to uptake and to eliminate Pd-PS NPs through feces. Whether longer exposures could cause a significant accumulation of NPs and produce associated biological effects remains to be studied.
- 10 September 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (18) , 1133
Open AccessDistribution and Effects of Model Palladium-Doped Nanoplastics in the Marine Mussel Mytilus galloprovincialis
While nanoplastics (NPs, Mytilus galloprovincialis. For this, mussels were dietarily exposed for 7 days to model palladium-doped-polystyrene NPs (Pd-PS NPs) of 142.6 ± 1.0 nm at 1 × 109 Pd-PS NPs/mL. ICP-MS analysis on water samples showed that after one day of exposure no Pd was detected suggesting that mussels cleared the NPs. After 7 days of exposure, 14% of the Pd introduced in the tanks was found in feces. Less than 0.02% passed into the hemolymph of mussels and consequently, no responses were observed on hemocytes. Approximately 1% of the Pd was found in soft tissues. This could be linked to the significantly higher prevalence of digestive tubule atrophy observed in exposed mussels in comparison to controls. No effects were observed at the whole organism level. In conclusion, mussels were able to uptake and to eliminate Pd-PS NPs through feces. Whether longer exposures could cause a significant accumulation of NPs and produce associated biological effects remains to be studied.
- Open Access
- 31 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (36) , 26284-26289
An Easy and Reliable Method for Calibrating Combustion-Based Total Organic Carbon Analyzers for Solid Samples Containing Less than 100 μg of Carbon Using Polystyrene Microspheres
Combustion-based total organic carbon (TOC) analyzers for solid samples are interesting tools for estimating the mass of microplastics in environmental samples. However, the low concentration of microplastics to be quantified may require TOC calibration below 100 μg of carbon (μgC), which could be laborious and tedious. This study proposes a fast, reliable, and easy-to-use calibration procedure that uses monomodal, compact polystyrene (PS) microspheres with nominal diameters of either 200 or 250 μm. Calibration curves obtained with the PS microspheres within the range of 8 to 50 μgC were linear and statistically equivalent to the reference calibration curve obtained with a diluted glucose solution. This demonstrates the effectiveness of this approach. This calibration procedure was successfully used to quantify the carbon content and accurately determine the size of unknown PS microspheres. The average size recovery was 98% ± 2% for 13 randomly selected particles ranging from 400 to 525 μm in diameter. Additionally, the study showed that the increase in carbon content following durable Nile Red staining of PS microspheres can be assessed using TOC analysis. This increase is likely due to organic solvent being trapped in the polymeric structure when PS particles are heated above their glass transition temperature. This alternative calibration procedure could improve the accuracy and ease of TOC analysis in various fields, including the monitoring of low microplastic content in environmental samples.
- 31 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (36) , 26284-26289
Open AccessAn Easy and Reliable Method for Calibrating Combustion-Based Total Organic Carbon Analyzers for Solid Samples Containing Less than 100 μg of Carbon Using Polystyrene Microspheres
Combustion-based total organic carbon (TOC) analyzers for solid samples are interesting tools for estimating the mass of microplastics in environmental samples. However, the low concentration of microplastics to be quantified may require TOC calibration below 100 μg of carbon (μgC), which could be laborious and tedious. This study proposes a fast, reliable, and easy-to-use calibration procedure that uses monomodal, compact polystyrene (PS) microspheres with nominal diameters of either 200 or 250 μm. Calibration curves obtained with the PS microspheres within the range of 8 to 50 μgC were linear and statistically equivalent to the reference calibration curve obtained with a diluted glucose solution. This demonstrates the effectiveness of this approach. This calibration procedure was successfully used to quantify the carbon content and accurately determine the size of unknown PS microspheres. The average size recovery was 98% ± 2% for 13 randomly selected particles ranging from 400 to 525 μm in diameter. Additionally, the study showed that the increase in carbon content following durable Nile Red staining of PS microspheres can be assessed using TOC analysis. This increase is likely due to organic solvent being trapped in the polymeric structure when PS particles are heated above their glass transition temperature. This alternative calibration procedure could improve the accuracy and ease of TOC analysis in various fields, including the monitoring of low microplastic content in environmental samples.
- Open Access
- 25 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (26) , 19427-19439
In-Depth Characterization of PEGylated Liposomes: Using AF4 and HPLC-CAD in Tandem as a Strategy for Composition Assessment and Postinsertion Optimization
The surface of nanoparticles for pharmaceutical use is crucial as it is the first interface that interacts with the biological environment in the body and therefore determines the fate of the nanoparticle itself. Aware of its key role, regulatory agencies urgently require rigorous quality control of the surface, including polyethylene glycol (PEG) coatings, a component widely used in nanomedicine, which is also present in recent vaccines against SARS-CoV-2, to ensure efficacy and safety. Building on a review of the literature and experimental testing, this study proposes a workflow to overcome critical issues related to liposome PEG coating. It integrates microfluidic synthesis with PEG postinsertion, using mild incubation conditions and a straightforward quality control analysis for method efficiency and reliability. Using multidetector Asymmetric-Flow Field-Flow Fractionation (AF4-MD) in combination with High-Performance Liquid Chromatography coupled to a Charged Aerosol Detector (HPLC-CAD) proved to be an efficient strategy for analyzing simultaneously both the size distribution and other size-dependent parameters with special attention on the precise composition of PEGylated liposomes. By exploiting the AF4 size separation of PEGylated liposomes from unincorporated PEG-lipid micelles, this approach enables the optimization of postinsertion reaction conditions and the validation of traditional purification methods. This comprehensive workflow allows for in-depth liposome characterization, focusing on critical quality attributes. It includes reliable and straightforward PEG coating determination, essential for postinsertion tuning, and offers potential adaptability to other stealth coatings, thus providing a valuable reference for nanomedicine developers, control laboratories, and regulatory bodies.
- 25 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (26) , 19427-19439
Open AccessIn-Depth Characterization of PEGylated Liposomes: Using AF4 and HPLC-CAD in Tandem as a Strategy for Composition Assessment and Postinsertion Optimization
The surface of nanoparticles for pharmaceutical use is crucial as it is the first interface that interacts with the biological environment in the body and therefore determines the fate of the nanoparticle itself. Aware of its key role, regulatory agencies urgently require rigorous quality control of the surface, including polyethylene glycol (PEG) coatings, a component widely used in nanomedicine, which is also present in recent vaccines against SARS-CoV-2, to ensure efficacy and safety. Building on a review of the literature and experimental testing, this study proposes a workflow to overcome critical issues related to liposome PEG coating. It integrates microfluidic synthesis with PEG postinsertion, using mild incubation conditions and a straightforward quality control analysis for method efficiency and reliability. Using multidetector Asymmetric-Flow Field-Flow Fractionation (AF4-MD) in combination with High-Performance Liquid Chromatography coupled to a Charged Aerosol Detector (HPLC-CAD) proved to be an efficient strategy for analyzing simultaneously both the size distribution and other size-dependent parameters with special attention on the precise composition of PEGylated liposomes. By exploiting the AF4 size separation of PEGylated liposomes from unincorporated PEG-lipid micelles, this approach enables the optimization of postinsertion reaction conditions and the validation of traditional purification methods. This comprehensive workflow allows for in-depth liposome characterization, focusing on critical quality attributes. It includes reliable and straightforward PEG coating determination, essential for postinsertion tuning, and offers potential adaptability to other stealth coatings, thus providing a valuable reference for nanomedicine developers, control laboratories, and regulatory bodies.
- Open Access
- 14 October 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (20) , 1565
Characterisation of Nanocellulose Types Using Complementary Techniques and Its Application to Detecting Bacterial Nanocellulose in Food Products
Nanocellulose has attracted significant attention in recent years due to its distinctive properties and vast potential applications across various fields. This study encompasses two distinct yet interconnected activities: the characterisation of eight different types of nanocellulose test materials, including crystalline, fibrillated, and bacterial nanocellulose, using a range of analytical techniques such as dynamic light scattering (DLS), asymmetric flow field-flow fractionation (AF4) coupled to multi-angle light scattering (MALS) and DLS, and transmission electron microscopy (TEM), and a focused case study employing a tiered analytical approach to identify bacterial nanocellulose in commercially available food products like pudding and drinks with nata de coco, SCOBY, and kombucha. The results demonstrate that different types of nanocellulose can be distinguished by their unique physicochemical properties using a combination of analytical techniques. This finding was used for the identification of bacterial nanocellulose in food products by combining pyGC-MS for cellulose identification, TEM for nanosize range determination, and XRD for crystallinity analysis to distinguish between bacterial and fibrillated nanocellulose. The study advances fundamental understanding of nanocellulose and provides tools to facilitate potential future regulatory compliance.
- 14 October 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (20) , 1565
Open AccessCharacterisation of Nanocellulose Types Using Complementary Techniques and Its Application to Detecting Bacterial Nanocellulose in Food Products
Nanocellulose has attracted significant attention in recent years due to its distinctive properties and vast potential applications across various fields. This study encompasses two distinct yet interconnected activities: the characterisation of eight different types of nanocellulose test materials, including crystalline, fibrillated, and bacterial nanocellulose, using a range of analytical techniques such as dynamic light scattering (DLS), asymmetric flow field-flow fractionation (AF4) coupled to multi-angle light scattering (MALS) and DLS, and transmission electron microscopy (TEM), and a focused case study employing a tiered analytical approach to identify bacterial nanocellulose in commercially available food products like pudding and drinks with nata de coco, SCOBY, and kombucha. The results demonstrate that different types of nanocellulose can be distinguished by their unique physicochemical properties using a combination of analytical techniques. This finding was used for the identification of bacterial nanocellulose in food products by combining pyGC-MS for cellulose identification, TEM for nanosize range determination, and XRD for crystallinity analysis to distinguish between bacterial and fibrillated nanocellulose. The study advances fundamental understanding of nanocellulose and provides tools to facilitate potential future regulatory compliance.
- Open Access
- 19 May 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (14) , 2983-2996
Total organic carbon (TOC): a simple tool for assessing micro(nano)plastics and nanocellulose recovery during size-based fractionation
The assessment of analyte recovery during sample preparation is a critical quality control parameter in method development. While elemental mass spectrometry techniques, such as ICP-MS, are very effective for assessing the recovery of particulate materials containing metallic elements, there is no equivalent applicable to metal-free carbon or CHNO-based particulate polymer materials. Vibrational spectro-microscopy or thermo-analytical techniques can be used to quantify polymer-based micro- and nanoparticles, but are typically expensive and time-consuming techniques that require higher levels of expertise. This study investigated the potential of a liquid-based total organic carbon (TOC) analyzer as a simple, cost-effective, and universal method for determining the recovery of polymer-based particulate micro- and nanomaterials following filtration, centrifugation, and asymmetric flow field flow fractionation (AF4) processes. A good correlation between solid contents and TOC analysis was demonstrated for standard polystyrene (PS) particle suspensions of various sizes, ranging from 50 nm to 90 μm (79.2 to 113.6% recovery), and other types of synthetic and natural polymeric particle suspensions, including polyethylene (PE), polypropylene (PP), polyvinyl chloride (PVC), polyethylene terephthalate (PET), and cellulose (86.2 to 126.2% recovery). Liquid-based TOC was then successfully applied to estimate particle recovery after various preparatory and fractionation steps, including the determination of filtration recoveries for nanocellulose suspensions (99.0 to 101.4% recovery) and PS micro- and nanoparticles spiked into environmental lake and river freshwater samples (70 to 96% recovery). The combination of TOC and single particle extinction and scattering (SPES) measurements allowed the tracking and quantification of three different populations of PS particles in a mixture (200, 500, and 1000 nm) during successive centrifugation steps (113.8 ± 13.9% cumulative recovery). Finally, this study demonstrated the suitability of TOC for determining both the absolute and relative recoveries of polymer-based particulate materials after AF4 fractionation in line with ISO standards. Liquid-based TOC proved to be a valuable tool for directly tracking, quantifying, and evaluating the recovery of polymer-based micro- and nanoparticles in model and environmental water samples before and after routine size-based fractionation steps. Graphical abstract Graphical abstract created in BioRender (https://BioRender.com/u57r657)
- 19 May 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (14) , 2983-2996
Open AccessTotal organic carbon (TOC): a simple tool for assessing micro(nano)plastics and nanocellulose recovery during size-based fractionation
The assessment of analyte recovery during sample preparation is a critical quality control parameter in method development. While elemental mass spectrometry techniques, such as ICP-MS, are very effective for assessing the recovery of particulate materials containing metallic elements, there is no equivalent applicable to metal-free carbon or CHNO-based particulate polymer materials. Vibrational spectro-microscopy or thermo-analytical techniques can be used to quantify polymer-based micro- and nanoparticles, but are typically expensive and time-consuming techniques that require higher levels of expertise. This study investigated the potential of a liquid-based total organic carbon (TOC) analyzer as a simple, cost-effective, and universal method for determining the recovery of polymer-based particulate micro- and nanomaterials following filtration, centrifugation, and asymmetric flow field flow fractionation (AF4) processes. A good correlation between solid contents and TOC analysis was demonstrated for standard polystyrene (PS) particle suspensions of various sizes, ranging from 50 nm to 90 μm (79.2 to 113.6% recovery), and other types of synthetic and natural polymeric particle suspensions, including polyethylene (PE), polypropylene (PP), polyvinyl chloride (PVC), polyethylene terephthalate (PET), and cellulose (86.2 to 126.2% recovery). Liquid-based TOC was then successfully applied to estimate particle recovery after various preparatory and fractionation steps, including the determination of filtration recoveries for nanocellulose suspensions (99.0 to 101.4% recovery) and PS micro- and nanoparticles spiked into environmental lake and river freshwater samples (70 to 96% recovery). The combination of TOC and single particle extinction and scattering (SPES) measurements allowed the tracking and quantification of three different populations of PS particles in a mixture (200, 500, and 1000 nm) during successive centrifugation steps (113.8 ± 13.9% cumulative recovery). Finally, this study demonstrated the suitability of TOC for determining both the absolute and relative recoveries of polymer-based particulate materials after AF4 fractionation in line with ISO standards. Liquid-based TOC proved to be a valuable tool for directly tracking, quantifying, and evaluating the recovery of polymer-based micro- and nanoparticles in model and environmental water samples before and after routine size-based fractionation steps. Graphical abstract Graphical abstract created in BioRender (https://BioRender.com/u57r657)
- Open Access
Representative Test Material for Validation of Density Separation as Part of Microplastic Quantification in Drinking Water
The evolving regulatory landscape for microplastics—including the European Union’s Drinking Water Directive—underscores the importance of addressing the analytics of emerging contaminants in water, ensuring public health protection, and fostering scientific advancements in environmental monitoring. This work aims to contribute to these advancements by sharing the strategy of test material selection and characterisation for the validation of sample treatment protocols. The article describes a PVC-based representative test material of industrial origin, its physicochemical characterisation, and its application in density separation procedure evaluation, compatibly with the European Commission’s recommendations for quantifying microplastics in water for human consumption. The work shares our protocol for the durable fluorescent labelling of microplastic particles and for the centrifugal density separation of microplastics from other particulate contaminants in drinking water samples. It reports density and viscosity values for the zinc chloride solutions used to feed the theoretical calculations and recovery values achieved with the presented density separation protocol.
Open AccessRepresentative Test Material for Validation of Density Separation as Part of Microplastic Quantification in Drinking Water
The evolving regulatory landscape for microplastics—including the European Union’s Drinking Water Directive—underscores the importance of addressing the analytics of emerging contaminants in water, ensuring public health protection, and fostering scientific advancements in environmental monitoring. This work aims to contribute to these advancements by sharing the strategy of test material selection and characterisation for the validation of sample treatment protocols. The article describes a PVC-based representative test material of industrial origin, its physicochemical characterisation, and its application in density separation procedure evaluation, compatibly with the European Commission’s recommendations for quantifying microplastics in water for human consumption. The work shares our protocol for the durable fluorescent labelling of microplastic particles and for the centrifugal density separation of microplastics from other particulate contaminants in drinking water samples. It reports density and viscosity values for the zinc chloride solutions used to feed the theoretical calculations and recovery values achieved with the presented density separation protocol.
- Open Access
- 15 January 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (2) , 116
Exploring Nanoplastics Bioaccumulation in Freshwater Organisms: A Study Using Gold-Doped Polymeric Nanoparticles
The evaluation of nanoplastics bioaccumulation in living organisms is still considered an emerging challenge, especially as global plastic production continues to grow, posing a significant threat to humans, animals, and the environment. The goal of this work is to advance the development of standardized methods for reliable biomonitoring in the future. It is crucial to employ sensitive techniques that can detect and measure nanoplastics effectively, while ensuring minimal impact on the environment. To understand nanoplastics retention by freshwater organisms, phyto- and zooplankton, and mussels were exposed to gold-doped polymeric nanoparticles synthesized in our laboratory. The results demonstrated that measuring gold content using inductively coupled plasma mass spectrometry (ICP-MS), along with confirmation of its presence through electron microscopy in selected exposed samples provides insight into the accumulation and release of nanoplastics by organisms playing a relevant ecological role at the early levels of aquatic food webs.
- 15 January 2025
- Published by MDPI AG in Nanomaterials
- Vol. 15 (2) , 116
Open AccessExploring Nanoplastics Bioaccumulation in Freshwater Organisms: A Study Using Gold-Doped Polymeric Nanoparticles
The evaluation of nanoplastics bioaccumulation in living organisms is still considered an emerging challenge, especially as global plastic production continues to grow, posing a significant threat to humans, animals, and the environment. The goal of this work is to advance the development of standardized methods for reliable biomonitoring in the future. It is crucial to employ sensitive techniques that can detect and measure nanoplastics effectively, while ensuring minimal impact on the environment. To understand nanoplastics retention by freshwater organisms, phyto- and zooplankton, and mussels were exposed to gold-doped polymeric nanoparticles synthesized in our laboratory. The results demonstrated that measuring gold content using inductively coupled plasma mass spectrometry (ICP-MS), along with confirmation of its presence through electron microscopy in selected exposed samples provides insight into the accumulation and release of nanoplastics by organisms playing a relevant ecological role at the early levels of aquatic food webs.
- Open Access
- 10 September 2023
- Published by Elsevier in Food Control
- Vol. 155
Large-scale screening of E171 food additive (TiO2) on the French market from 2018 to 2022: Occurrence and particle size distribution in various food categories
- 10 September 2023
- Published by Elsevier in Food Control
- Vol. 155
Open AccessLarge-scale screening of E171 food additive (TiO2) on the French market from 2018 to 2022: Occurrence and particle size distribution in various food categories
- 22 May 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (7) , 1380-1386
Combination of 47Ti and 48Ti for the determination of highly polydisperse TiO2 particle size distributions by spICP-MS
Particle size distribution (PSD) of a highly polydisperse TiO2 sample determined by spICP-MS.
- 22 May 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (7) , 1380-1386
Combination of 47Ti and 48Ti for the determination of highly polydisperse TiO2 particle size distributions by spICP-MS
Particle size distribution (PSD) of a highly polydisperse TiO2 sample determined by spICP-MS.