Dan-Qing Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dan-Qing Guo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Shun-Cong Zhang
Guangzhou University of Chinese Medicine
4 shared publications - De Liang
Department of Spinal Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
3 shared publications - Hui-Zhi Guo
Guangzhou University of Chinese Medicine
3 shared publications - Jian-Cheng Peng
The 1st Institute of Clinical Medicine, Guangzhou University of Chinese Medicine, 12 Airport Road, Baiyun District, Guangzhou 510405, Guangdong, People's Republic of China; Spine Surgery Department, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510407, China
3 shared publications - Yan-Huai Ma
The 1st Institute of Clinical Medicine, Guangzhou University of Chinese Medicine, 12 Airport Road, Baiyun District, Guangzhou 510405, Guangdong, People's Republic of China; Spine Surgery Department, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510407, China
3 shared publications - Yong-Chao Tang
Spine Surgery Department, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
3 shared publications
Latest Publications
- 1 August 2020
- Published by Elsevier in World Neurosurgery
- Vol. 140, e121-e128
Pedicle Screw Fixation in Single-Level, Double-Level, or Multilevel Posterior Lumbar Fusion for Osteoporotic Spine: A Retrospective Study with a Minimum 2-Year Follow-Up
- 1 August 2020
- Published by Elsevier in World Neurosurgery
- Vol. 140, e121-e128
Pedicle Screw Fixation in Single-Level, Double-Level, or Multilevel Posterior Lumbar Fusion for Osteoporotic Spine: A Retrospective Study with a Minimum 2-Year Follow-Up
- Open Access
- 13 July 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-10
Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
Background: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3 ml) can be injected to enhance screw stability. To date, there have been no studies on the relationship between adjacent segment degeneration and the volume of PMMA. This study aimed to explore the influence of CAPSI with different volumes of PMMA in osteoporotic lumbar vertebrae over adjacent segments by using finite element analysis. Methods: Seven different finite element models were reconstructed and simulated under different loading conditions, including (1) an intact model, (2) three single-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml), and (3) three double-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml). To improve the accuracy of the finite element analysis, the models of the injectable pedicle screw and bone cement were created by using a three-dimensional scanning machine and the CAPSI patient’s CT data, respectively. The range of motion (ROM), the stress of intervertebral discs, and the stress of facet in the adjacent segment were comparatively analyzed among the different models. Results: The ROMs of the different segments were compared with experimental data, with good agreement under the different load conditions (21.3°, 13.55°, 13.99°, and 6.11° in flexion, extension, bending, and rotation at L3-S1 level, respectively). Compared with the intact model, the ROM, disc stresses, and facet stress in adjacent segments were found to be higher in the six operative models. Otherwise, with a larger volume of PMMA injected, the ROM, disc stresses, and facet stress slightly increased at the adjacent segment. However, the differences were insignificant with the biggest difference less than 3.8%. Conclusions: CAPSI could increase the incidence of disk degeneration in the adjacent segment, while within a certain range, different volumes of PMMA provided an approximate impact over the adjacent segment degeneration.
- 13 July 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-10
Open AccessInfluence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: a 3D finite element analysis
Background: Polymethylmethacrylate (PMMA) is commonly used for cement-augmented pedicle screw instrumentation (CAPSI) to improve the fixation stability and reduce the risk of screw loosening in the osteoporotic thoracolumbar spine. Biomechanical researches have shown that various dose of cement (1-3 ml) can be injected to enhance screw stability. To date, there have been no studies on the relationship between adjacent segment degeneration and the volume of PMMA. This study aimed to explore the influence of CAPSI with different volumes of PMMA in osteoporotic lumbar vertebrae over adjacent segments by using finite element analysis. Methods: Seven different finite element models were reconstructed and simulated under different loading conditions, including (1) an intact model, (2) three single-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml), and (3) three double-level CAPSI models with different volumes of PMMA (1, 1.73, and 2.5 ml). To improve the accuracy of the finite element analysis, the models of the injectable pedicle screw and bone cement were created by using a three-dimensional scanning machine and the CAPSI patient’s CT data, respectively. The range of motion (ROM), the stress of intervertebral discs, and the stress of facet in the adjacent segment were comparatively analyzed among the different models. Results: The ROMs of the different segments were compared with experimental data, with good agreement under the different load conditions (21.3°, 13.55°, 13.99°, and 6.11° in flexion, extension, bending, and rotation at L3-S1 level, respectively). Compared with the intact model, the ROM, disc stresses, and facet stress in adjacent segments were found to be higher in the six operative models. Otherwise, with a larger volume of PMMA injected, the ROM, disc stresses, and facet stress slightly increased at the adjacent segment. However, the differences were insignificant with the biggest difference less than 3.8%. Conclusions: CAPSI could increase the incidence of disk degeneration in the adjacent segment, while within a certain range, different volumes of PMMA provided an approximate impact over the adjacent segment degeneration.
- Open Access
- 28 April 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-12
Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease
Background: The increase of augmented level and bone cement dose are accompanied by the rising incidence of cement leakage (CL) of cement-augmented pedicle screw instrumentation (CAPSI). But the effect and potential risks of the application of CAPSI to osteoporotic lumbar degenerative disease (LDD) have not been studied in the case of multilevel fixation. This study aimed to investigate the effectiveness and potential complications of using multilevel CAPSI for patients with osteoporotic LDD. Methods: A total of 93 patients with multilevel LDD were divided into the CAPSI group (46 subjects) and the conventional pedicle screw (CPS) group (47 subjects), including 75 cases for three levels and 18 cases for four levels. Relevant data were compared between two groups, including baseline data, clinical results, and complications. Results: In the CAPSI group, a total of 336 augmented screws was placed bilaterally. The CL was observed in 116 screws (34.52%). Three cemented screws (0.89%) were found loosened during the follow-up and the overall fusion rate was 93.47%. For perioperative complications, two patients (4.35%) experienced pulmonary cement embolism (PCE), one patient augmented vertebral fracture, and three patients (6.52%) wound infection. And in the CPS group, thirty-three screws (8.46%) suffered loosening in cranial and caudal vertebra with a fusion rate of 91.49%. The operation time and hospital stay of CAPSI group were longer than the CPS group, but CAPSI group has a lower screw loosening percentage (P<0. 05). And in terms of blood loss, perioperative complications, fusion rate, and VAS and ODI scores at the follow-up times, there were no significant differences between the two groups. Conclusions: Patients with osteoporotic LDD underwent multilevel CPS fixation have a higher rate of screw loosening in the cranial and caudal vertebra. The application of cemented pedicle screws for multilevel LDD can achieve better stability and less screw loosening, but it also accompanied by longer operating time, higher incidence of CL, PCE and wound infections. Selective cement augmentation of cranial and caudal pedicle screws may be a worthy strategy to decrease the complications.
- 28 April 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-12
Open AccessEffect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease
Background: The increase of augmented level and bone cement dose are accompanied by the rising incidence of cement leakage (CL) of cement-augmented pedicle screw instrumentation (CAPSI). But the effect and potential risks of the application of CAPSI to osteoporotic lumbar degenerative disease (LDD) have not been studied in the case of multilevel fixation. This study aimed to investigate the effectiveness and potential complications of using multilevel CAPSI for patients with osteoporotic LDD. Methods: A total of 93 patients with multilevel LDD were divided into the CAPSI group (46 subjects) and the conventional pedicle screw (CPS) group (47 subjects), including 75 cases for three levels and 18 cases for four levels. Relevant data were compared between two groups, including baseline data, clinical results, and complications. Results: In the CAPSI group, a total of 336 augmented screws was placed bilaterally. The CL was observed in 116 screws (34.52%). Three cemented screws (0.89%) were found loosened during the follow-up and the overall fusion rate was 93.47%. For perioperative complications, two patients (4.35%) experienced pulmonary cement embolism (PCE), one patient augmented vertebral fracture, and three patients (6.52%) wound infection. And in the CPS group, thirty-three screws (8.46%) suffered loosening in cranial and caudal vertebra with a fusion rate of 91.49%. The operation time and hospital stay of CAPSI group were longer than the CPS group, but CAPSI group has a lower screw loosening percentage (P<0. 05). And in terms of blood loss, perioperative complications, fusion rate, and VAS and ODI scores at the follow-up times, there were no significant differences between the two groups. Conclusions: Patients with osteoporotic LDD underwent multilevel CPS fixation have a higher rate of screw loosening in the cranial and caudal vertebra. The application of cemented pedicle screws for multilevel LDD can achieve better stability and less screw loosening, but it also accompanied by longer operating time, higher incidence of CL, PCE and wound infections. Selective cement augmentation of cranial and caudal pedicle screws may be a worthy strategy to decrease the complications.
- Open Access
- 6 June 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-7
Augmented pedicle trajectory applied on the osteoporotic spine with lumbar degenerative disease: mid-term outcome
To compare the safety and efficiency of cement-augmented pedicle screw with traditional pedicle screw technique applied on the patients in the osteoporotic spine with lumbar degenerative diseases. Fifty-six patients followed up at least 2 years were enrolled in our institute with retrospectively reviewed from January 2009 to June 2014, diagnosed as lumbar spondylolisthesis, or lumbar stenosis, with T score ≤− 2.5 SD of BMD, and received less than three-segment PLIF or TLIF. All patients were divided into 2 groups: 28 (2 males, 26 females) in polymethylmethacrylate-augmented pedicle screw group (PSA) group, the other 28 (3 males, 25 females) in traditional pedicle screw group (TPS). Surgical data including the operation time, intra-operative blood loss, hospitalization day and surgical complications were recorded, as well as the radiological parameters measured from the postoperative X-rays and CT scans containing the rates of fusion, screw loosening, and cage subsidence incidence. In addition, the visual analog scores (VAS) and Oswestry Disability Index (ODI) were evaluated preoperatively and postoperatively. The average follow-up period was 34.32 months (ranging from 24 months to 51 months). Compared with PSA group, operation time and average hospital stay in the TPS group decreased significantly (P < 0.05). While no statistical difference for blood loss between 2 groups (P > 0.05). At 2 years postoperation, from CT-scans, 2/172 screws loosening and 1/56 segment non-union occurred in PSA group, with significantly lower incidence than those in TPS group (8/152 screws loosening and 6/50 segments non-union occurred, P < 0.05). Regarding the cage subsidence, 24 segments found height loss (5.30 ± 1.92 mm) in PSA group without difference compared with that of 19 segments (4.78 ± 1.37 mm) in TPS group (P > 0.05). Besides, the number and the location of cages and the leakage of the cement were found out little related with the subsidence in the PSA group (P > 0.05). After surgeries, VAS and ODI at 1 month, 6 months, 12 months, and last follow-up improved significantly in two groups (P < 0.05). There were no significant differences in VAS and ODI preoperatively and postoperatively between 2 groups (P > 0.05). In addition, eight patients with asymptomatic trajectory PMMA leakages were detected. Cement-augmented pedicle screw technique is effective and safe in the osteoporotic spine with lumbar degenerative diseases, with better fusion rates and less screw loosening incidence. There is no difference in the fusion rate and loosening rate between the two groups in the single segment patients; however, there are better fusion rate and lower pedicle screw loosening rate of the PSA group in the double or multiple group patients.
- 6 June 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-7
Open AccessAugmented pedicle trajectory applied on the osteoporotic spine with lumbar degenerative disease: mid-term outcome
To compare the safety and efficiency of cement-augmented pedicle screw with traditional pedicle screw technique applied on the patients in the osteoporotic spine with lumbar degenerative diseases. Fifty-six patients followed up at least 2 years were enrolled in our institute with retrospectively reviewed from January 2009 to June 2014, diagnosed as lumbar spondylolisthesis, or lumbar stenosis, with T score ≤− 2.5 SD of BMD, and received less than three-segment PLIF or TLIF. All patients were divided into 2 groups: 28 (2 males, 26 females) in polymethylmethacrylate-augmented pedicle screw group (PSA) group, the other 28 (3 males, 25 females) in traditional pedicle screw group (TPS). Surgical data including the operation time, intra-operative blood loss, hospitalization day and surgical complications were recorded, as well as the radiological parameters measured from the postoperative X-rays and CT scans containing the rates of fusion, screw loosening, and cage subsidence incidence. In addition, the visual analog scores (VAS) and Oswestry Disability Index (ODI) were evaluated preoperatively and postoperatively. The average follow-up period was 34.32 months (ranging from 24 months to 51 months). Compared with PSA group, operation time and average hospital stay in the TPS group decreased significantly (P < 0.05). While no statistical difference for blood loss between 2 groups (P > 0.05). At 2 years postoperation, from CT-scans, 2/172 screws loosening and 1/56 segment non-union occurred in PSA group, with significantly lower incidence than those in TPS group (8/152 screws loosening and 6/50 segments non-union occurred, P < 0.05). Regarding the cage subsidence, 24 segments found height loss (5.30 ± 1.92 mm) in PSA group without difference compared with that of 19 segments (4.78 ± 1.37 mm) in TPS group (P > 0.05). Besides, the number and the location of cages and the leakage of the cement were found out little related with the subsidence in the PSA group (P > 0.05). After surgeries, VAS and ODI at 1 month, 6 months, 12 months, and last follow-up improved significantly in two groups (P < 0.05). There were no significant differences in VAS and ODI preoperatively and postoperatively between 2 groups (P > 0.05). In addition, eight patients with asymptomatic trajectory PMMA leakages were detected. Cement-augmented pedicle screw technique is effective and safe in the osteoporotic spine with lumbar degenerative diseases, with better fusion rates and less screw loosening incidence. There is no difference in the fusion rate and loosening rate between the two groups in the single segment patients; however, there are better fusion rate and lower pedicle screw loosening rate of the PSA group in the double or multiple group patients.