Yan Jin Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yan Jin Lee has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Hao Wang
Department of Mechanical Engineering, National University of Singapore, Singapore, Singapore
5 shared publications - Naresh Kumar
Department of Orthopaedic Surgery, National University Hospital, Singapore
3 shared publications A. Senthil Kumar
Department of Mechanical Engineering, College of Design and Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore
2 shared publications- Gabriel Zihui Mbbs Leow
Department of Orthopaedic Surgery, National University Hospital, National University Health System Tower Block, Level 11, 1E Kent Ridge Road, 119228, Singapore
2 shared publications Hao Wang
2 shared publications- Joshua Mbbs Kalai
Department of Orthopaedic Surgery, National University Hospital, National University Health System Tower Block, Level 11, 1E Kent Ridge Road, 119228, Singapore
2 shared publications
Latest Publications
- 26 March 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 207, 111634
Mapping fusion zones to motion resistance: Finite element insights into return-to-activity after interbody fusion
- 26 March 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 207, 111634
Mapping fusion zones to motion resistance: Finite element insights into return-to-activity after interbody fusion
- Open Access
- 16 February 2026
- Published by Wolters Kluwer Health in Spine Open
- Vol. 2 (1)
Evaluating Two Recombinant BMP-2 Formulations in Transforaminal Lumbar Fusion: Does the Carrier Matter?
Study Design: Retrospective cohort study. Objective: To perform an exploratory comparison of clinical, radiologic, and perioperative outcomes of transforaminal lumbar interbody fusion (TLIF) using two recombinant human bone morphogenetic protein-2 (rhBMP-2) formulations, Infuse® (Medtronic, Minneapolis) and Novosis® (CG Bio, Seoul, South Korea). Summary of Background Data: Bone morphogenetic protein-2 has become a common osteoinductive agent in lumbar fusion. Infuse®, derived from Chinese Hamster Ovary cells, is effective but associated with inflammatory complications. Novosis®, an Escherichia coli –derived rhBMP-2 embedded in a hydroxyapatite/β-tricalcium phosphate carrier, potentially allows sustained protein release and lower local inflammatory response. Comparative data between these two agents in TLIF remains limited. Materials and Methods: We retrospectively reviewed patients who underwent 1- to 3-level TLIF for degenerative lumbar disorders using either Infuse® or Novosis® between 2018 and 2023. Demographics, perioperative parameters, and complications were extracted from medical records. Radiologic fusion was assessed using a six-zone scoring system at 3, 6, and 12 months. Clinical outcomes included visual analogue scale (VAS) for pain, Oswestry Disability Index (ODI), and SF-36 physical (PCS) and mental (MCS) scores. Groups were compared using t -tests or χ 2 analysis with significance at P vs . 10.5% at 3 mo; P vs . 5.1±1.9 d; P =0.011). At 12 months, fusion rates were comparable (100% vs . 93%; P =0.162). ODI improvement favored Novosis® ( P =0.007), while SF-36 MCS improvement favored Infuse® ( P <0.001). Subgroup analysis for 1- and 2-level TLIFs did not show any significant difference in the measured outcomes. No ectopic bone formation or malignancy was observed. Conclusion: Novosis® showed earlier radiographic consolidation and a shorter drain duration, findings that may reflect carrier-specific properties, whereas Infuse® demonstrated greater mental health improvement. Overall, fusion and clinical outcomes were satisfactory with each formulation, although these observations remain exploratory and require validation in larger, prospective studies. Level of Evidence: Level III.
- 16 February 2026
- Published by Wolters Kluwer Health in Spine Open
- Vol. 2 (1)
Open AccessEvaluating Two Recombinant BMP-2 Formulations in Transforaminal Lumbar Fusion: Does the Carrier Matter?
Study Design: Retrospective cohort study. Objective: To perform an exploratory comparison of clinical, radiologic, and perioperative outcomes of transforaminal lumbar interbody fusion (TLIF) using two recombinant human bone morphogenetic protein-2 (rhBMP-2) formulations, Infuse® (Medtronic, Minneapolis) and Novosis® (CG Bio, Seoul, South Korea). Summary of Background Data: Bone morphogenetic protein-2 has become a common osteoinductive agent in lumbar fusion. Infuse®, derived from Chinese Hamster Ovary cells, is effective but associated with inflammatory complications. Novosis®, an Escherichia coli –derived rhBMP-2 embedded in a hydroxyapatite/β-tricalcium phosphate carrier, potentially allows sustained protein release and lower local inflammatory response. Comparative data between these two agents in TLIF remains limited. Materials and Methods: We retrospectively reviewed patients who underwent 1- to 3-level TLIF for degenerative lumbar disorders using either Infuse® or Novosis® between 2018 and 2023. Demographics, perioperative parameters, and complications were extracted from medical records. Radiologic fusion was assessed using a six-zone scoring system at 3, 6, and 12 months. Clinical outcomes included visual analogue scale (VAS) for pain, Oswestry Disability Index (ODI), and SF-36 physical (PCS) and mental (MCS) scores. Groups were compared using t -tests or χ 2 analysis with significance at P vs . 10.5% at 3 mo; P vs . 5.1±1.9 d; P =0.011). At 12 months, fusion rates were comparable (100% vs . 93%; P =0.162). ODI improvement favored Novosis® ( P =0.007), while SF-36 MCS improvement favored Infuse® ( P <0.001). Subgroup analysis for 1- and 2-level TLIFs did not show any significant difference in the measured outcomes. No ectopic bone formation or malignancy was observed. Conclusion: Novosis® showed earlier radiographic consolidation and a shorter drain duration, findings that may reflect carrier-specific properties, whereas Infuse® demonstrated greater mental health improvement. Overall, fusion and clinical outcomes were satisfactory with each formulation, although these observations remain exploratory and require validation in larger, prospective studies. Level of Evidence: Level III.
- Open Access
- 5 August 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 38, 1856-1867
Printability assessment and mechanical properties of filament-free 3D printed polyether-ether-ketone (PEEK) composites
- 5 August 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 38, 1856-1867
Open AccessPrintability assessment and mechanical properties of filament-free 3D printed polyether-ether-ketone (PEEK) composites
- Open Access
- 7 January 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (10) , 12587-12599
Effects of differential plasticity on thermally enhanced machining of calcium fluoride
- 7 January 2025
- Published by Elsevier in Ceramics International
- Vol. 51 (10) , 12587-12599
Open AccessEffects of differential plasticity on thermally enhanced machining of calcium fluoride
- Open Access
- 2 March 2023
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 249
Predictive modelling for enhanced scratching of brittle ceramics with magneto-plasticity
- 2 March 2023
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 249
Open AccessPredictive modelling for enhanced scratching of brittle ceramics with magneto-plasticity
- 30 March 2022
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 124, 121-134
Magneto-plasticity in micro-cutting of single-crystal copper
- 30 March 2022
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 124, 121-134
Magneto-plasticity in micro-cutting of single-crystal copper
- 1 November 2021
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 91, 178-186
Microstructure evaluation of shear bands of microcutting chips in AA6061 alloy under the mechanochemical effect
- 1 November 2021
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 91, 178-186
Microstructure evaluation of shear bands of microcutting chips in AA6061 alloy under the mechanochemical effect
- 1 October 2021
- Published by Elsevier in Ceramics International
- Vol. 47 (20) , 28543-28556
Characterizing crack morphology toward improving ductile mode cutting of calcium fluoride
- 1 October 2021
- Published by Elsevier in Ceramics International
- Vol. 47 (20) , 28543-28556
Characterizing crack morphology toward improving ductile mode cutting of calcium fluoride
- 1 September 2021
- Published by Elsevier in International Journal of Machine Tools and Manufacture
- Vol. 168
Beneficial stress of a coating on ductile-mode cutting of single-crystal brittle material
- 1 September 2021
- Published by Elsevier in International Journal of Machine Tools and Manufacture
- Vol. 168
Beneficial stress of a coating on ductile-mode cutting of single-crystal brittle material
- Open Access
- 11 August 2020
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 4 (3) , 81
Suppression of Polycrystalline Diamond Tool Wear with Mechanochemical Effects in Micromachining of Ferrous Metal
A mechanochemical effect is investigated to reduce diamond tool wear by means of applying a surfactant to low-carbon magnetic iron during diamond turning. Orthogonal microcutting demonstrates the manifestation of the mechanochemical effect through the reduction of cutting forces by 30%, which supports the notion of lower cutting temperatures for reduced tribo-chemical wear. This is affirmed by the reduction in tool flank wear by up to 56% with the mechanochemical effect during diamond turning. While wear suppression increases by 9.4–16.15% with feeds from 5–20 μm/rev, it is not proportional to the reduction in cutting forces (31–39.8%), which suggests that the reduction in cutting energy does not directly correspond with the reduction in heat energy to sustain tribo-chemical tool wear. The strain localization during chip formation is proposed to serve as a heat source that hinders the wear mitigation efficiency. Finite element simulations demonstrate the heat generation during strain localization under the mechanochemical effect, which counteracts the reduced heat conversion from the plastic deformation and the transfer from tool–chip contact. Hence, this paper demonstrates the effectiveness of the mechanochemical method and its ability to reduce tool wear, but also establishes its limitations due to its inherent nature for heat generation.
- 11 August 2020
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 4 (3) , 81
Open AccessSuppression of Polycrystalline Diamond Tool Wear with Mechanochemical Effects in Micromachining of Ferrous Metal
A mechanochemical effect is investigated to reduce diamond tool wear by means of applying a surfactant to low-carbon magnetic iron during diamond turning. Orthogonal microcutting demonstrates the manifestation of the mechanochemical effect through the reduction of cutting forces by 30%, which supports the notion of lower cutting temperatures for reduced tribo-chemical wear. This is affirmed by the reduction in tool flank wear by up to 56% with the mechanochemical effect during diamond turning. While wear suppression increases by 9.4–16.15% with feeds from 5–20 μm/rev, it is not proportional to the reduction in cutting forces (31–39.8%), which suggests that the reduction in cutting energy does not directly correspond with the reduction in heat energy to sustain tribo-chemical tool wear. The strain localization during chip formation is proposed to serve as a heat source that hinders the wear mitigation efficiency. Finite element simulations demonstrate the heat generation during strain localization under the mechanochemical effect, which counteracts the reduced heat conversion from the plastic deformation and the transfer from tool–chip contact. Hence, this paper demonstrates the effectiveness of the mechanochemical method and its ability to reduce tool wear, but also establishes its limitations due to its inherent nature for heat generation.