Yusuke Hakuta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yusuke Hakuta has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Toshiaki Watanabe
System & Electronics Engineering Dept. II, Toyota Central R&D Labs., Inc., Nagakute 480-1192 Japan
2 shared publications - Akimasa Hirata
Nagoya Institute of Technology
1 shared publication Shuji Tomura
Toyota Central R&D Labs., Inc 41-1 480-1192 Yokomichi Nagakute Aichi Japan
1 shared publication- Takahiro Ito
Hiroshima City University
1 shared publication Tomohiko Jimbo
1 shared publication- Tomohiro Takenaka
Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya 466-8555 Japan
1 shared publication
Latest Publications
- Open Access
Decentralized Control for Heterogeneous Battery Energy Storage System
Battery energy storage systems (BESSs) are essential for stable power supply in renewable energy systems that can operate in all weather. Future BESSs will be massive and pluggable with several heterogeneous batteries. In this paper, a novel decentralized control method for a heterogeneous BESS is proposed, in which each battery autonomously operates based on its characteristics. First, a control method that uses only one broadcast signal for each type of battery is proposed. Second, the asymptotic stability of the tracking error is proved. Third, numerical simulations confirm that the proposed control method has robust tracking performance of the total electric power to the demanded power when some batteries fail and are detached from the system. Last, in order to suppress degradation of battery, equalization of the state of charge is achieved for each type of battery without communication among the batteries.
Open AccessDecentralized Control for Heterogeneous Battery Energy Storage System
Battery energy storage systems (BESSs) are essential for stable power supply in renewable energy systems that can operate in all weather. Future BESSs will be massive and pluggable with several heterogeneous batteries. In this paper, a novel decentralized control method for a heterogeneous BESS is proposed, in which each battery autonomously operates based on its characteristics. First, a control method that uses only one broadcast signal for each type of battery is proposed. Second, the asymptotic stability of the tracking error is proved. Third, numerical simulations confirm that the proposed control method has robust tracking performance of the total electric power to the demanded power when some batteries fail and are detached from the system. Last, in order to suppress degradation of battery, equalization of the state of charge is achieved for each type of battery without communication among the batteries.
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (1) , 313-318
Safety Standard Compliance of Human Exposure From Vehicle Cables Using Coupling Factors in the Frequency Range of 0.3–400 kHz
Human safety from electromagnetic fields in the cabin of automotive vehicles has become an important issue with the increased use of powertrain electrification. A current passing through the cable above the floor is one of the dominant sources emitting magnetic fields. However, the presently used method of assessing the compliance of the measured magnetic field with the permissible magnetic field (called reference level in International Commission on Non-Ionizing Radiation Protection guidelines) is overly conservative because the reference level is derived assuming a uniform field distribution. In such cases, internal electric fields should be evaluated for proper compliance. However, it is unclear how to best approach this in a practical situation. In this study, frequency- and body-part-dependent coupling factors corresponding to the guidelines for the general public are proposed for the assessment of internal electric field induced by nonuniform magnetic fields from the cable. The measured spatial peak magnetic field strength should be multiplied by the coupling factor before comparison with the field reference levels. In the simulated exposure scenario, the computational results indicate that the basic restrictions provide a safety margin of 11 over the field reference levels. The coupling factors may prove useful as a new straightforward compliance assessment measure in vehicle cabins.
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (1) , 313-318
Safety Standard Compliance of Human Exposure From Vehicle Cables Using Coupling Factors in the Frequency Range of 0.3–400 kHz
Human safety from electromagnetic fields in the cabin of automotive vehicles has become an important issue with the increased use of powertrain electrification. A current passing through the cable above the floor is one of the dominant sources emitting magnetic fields. However, the presently used method of assessing the compliance of the measured magnetic field with the permissible magnetic field (called reference level in International Commission on Non-Ionizing Radiation Protection guidelines) is overly conservative because the reference level is derived assuming a uniform field distribution. In such cases, internal electric fields should be evaluated for proper compliance. However, it is unclear how to best approach this in a practical situation. In this study, frequency- and body-part-dependent coupling factors corresponding to the guidelines for the general public are proposed for the assessment of internal electric field induced by nonuniform magnetic fields from the cable. The measured spatial peak magnetic field strength should be multiplied by the coupling factor before comparison with the field reference levels. In the simulated exposure scenario, the computational results indicate that the basic restrictions provide a safety margin of 11 over the field reference levels. The coupling factors may prove useful as a new straightforward compliance assessment measure in vehicle cabins.
- Open Access
- 13 June 2019
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 10 (2) , 41
Evaluation of the Magnetic Field Leakage from Two Wireless Power Transfer Systems for EV/PHV Driven Simultaneously
Wireless power transfer for electric and plug-in hybrid vehicles has been developed to facilitate battery charging. In a wireless power transfer system, because the magnetic field leaks to the surroundings of the vehicle, it is important to evaluate the quantitative human exposure. The International Commission on Non-Ionizing Radiation Protection provides guidelines for human exposure assessment. In this study, we evaluate the magnetic field leakage under two parking configurations and current phase differences for two vehicles being simultaneously charged (3.7 kW at 85 kHz per vehicle). The results of the analysis show that the magnetic field leakage is lower than the reference level of the guidelines for all cases and that the leakage could be reduced by controlling the phase difference between the two wireless power transfer systems equally distributed from the single high-frequency power source for each parking configuration.
- 13 June 2019
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 10 (2) , 41
Open AccessEvaluation of the Magnetic Field Leakage from Two Wireless Power Transfer Systems for EV/PHV Driven Simultaneously
Wireless power transfer for electric and plug-in hybrid vehicles has been developed to facilitate battery charging. In a wireless power transfer system, because the magnetic field leaks to the surroundings of the vehicle, it is important to evaluate the quantitative human exposure. The International Commission on Non-Ionizing Radiation Protection provides guidelines for human exposure assessment. In this study, we evaluate the magnetic field leakage under two parking configurations and current phase differences for two vehicles being simultaneously charged (3.7 kW at 85 kHz per vehicle). The results of the analysis show that the magnetic field leakage is lower than the reference level of the guidelines for all cases and that the leakage could be reduced by controlling the phase difference between the two wireless power transfer systems equally distributed from the single high-frequency power source for each parking configuration.