Lei Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Yuan has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Anfei Xu
5 shared publicationsAn-Fei Xu
School of Electrical and Electronic Engineering, Hubei University of Technology, Wuhan, China
2 shared publicationsHaiqing Cai
Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System, Guangzhou, China
2 shared publicationsJiawei Mei
Hubei University of Technology, Wuhan, China
2 shared publicationsKun Han
Hubei University of Technology, Wuhan, China
2 shared publicationsLiang Tu
Guangdong Provincial Key Laboratory of Intelligent Operation and Control for New Energy Power System, Guangzhou, China
2 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4820
Research on Customer-Side Microgrid Inverters for Grid-Connected Non-Export Operation
To address two key issues caused by the disorderly connection of high-penetration photovoltaic (PV) grid-connected devices to low-voltage distribution networks, power quality deterioration and bidirectional active power flow, the latter of which may cause voltage violations, protection mis-operation, and metering errors, existing conventional control strategies for grid-connected inverters, such as droop control, active and reactive Power control, Virtual Synchronous Generator control, and Voltage and Frequency control, cannot simultaneously solve these two problems. To address this issue, this study proposes a customer-side microgrid grid-connected inverter device and its command signal calculation method. The method compares the load active current with the active current calculated based on PV output, load demand, and energy storage state of charge (SOC) to generate per-phase command currents, strictly limiting active power to flow from the grid to local loads, thereby achieving grid-connected non-export operation. The device has four operating modes: power quality compensation, bidirectional power supply, unidirectional power supply, and nighttime charging. MATLAB/Simulink simulations show that the proposed device can suppress the grid-side current total harmonic distortion (THD) below 5%, with a mode-switching response time of only 10–30 ms. Under load step changes, the grid active current remains zero, and reverse power flow is completely eliminated in all operating modes.
- 19 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4820
Open AccessResearch on Customer-Side Microgrid Inverters for Grid-Connected Non-Export Operation
To address two key issues caused by the disorderly connection of high-penetration photovoltaic (PV) grid-connected devices to low-voltage distribution networks, power quality deterioration and bidirectional active power flow, the latter of which may cause voltage violations, protection mis-operation, and metering errors, existing conventional control strategies for grid-connected inverters, such as droop control, active and reactive Power control, Virtual Synchronous Generator control, and Voltage and Frequency control, cannot simultaneously solve these two problems. To address this issue, this study proposes a customer-side microgrid grid-connected inverter device and its command signal calculation method. The method compares the load active current with the active current calculated based on PV output, load demand, and energy storage state of charge (SOC) to generate per-phase command currents, strictly limiting active power to flow from the grid to local loads, thereby achieving grid-connected non-export operation. The device has four operating modes: power quality compensation, bidirectional power supply, unidirectional power supply, and nighttime charging. MATLAB/Simulink simulations show that the proposed device can suppress the grid-side current total harmonic distortion (THD) below 5%, with a mode-switching response time of only 10–30 ms. Under load step changes, the grid active current remains zero, and reverse power flow is completely eliminated in all operating modes.
- 5 January 2026
- Published by Springer Nature in Journal of Power Electronics
LADRC-based fast transient response control strategy for FSBB converters
- 5 January 2026
- Published by Springer Nature in Journal of Power Electronics
LADRC-based fast transient response control strategy for FSBB converters
- 17 September 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (6) , 1249-1260
Double-vector model free current predictive control based on LESO for single-phase NPC three-level inverters
- 17 September 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (6) , 1249-1260
Double-vector model free current predictive control based on LESO for single-phase NPC three-level inverters
- 22 August 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (12) , 15267-15277
Three-vector model predictive control without weight coefficient based on three-phase neutral point clamped inverter
- 22 August 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (12) , 15267-15277
Three-vector model predictive control without weight coefficient based on three-phase neutral point clamped inverter
- Open Access
- 29 May 2025
- Published by Springer Nature in Research Square
Three-vector Model Predictive Control without Weight Coefficient based on Three-phase Neutral Point Clamped Inverter
Three-phase three-level neutral point clamped inverters are widely used in new energy fields such as photovoltaic power generation and wind power generation by virtue of their multilevel topology. The traditional three-vector model predictive control can solve the problems of current harmonics and unfixed switching frequency that exist in the single-vector model predictive control, but the traditional three-vector model predictive control still has the problems of large computation and difficult design of weighting factors. Based on this, this paper proposes a three-vector model predictive current control without weighting factors. The method firstly selects the voltage vectors by dividing the sectors to eliminate the weighting factors, secondly adopts the principle of non-differential beat control to obtain the reference voltage and the optimal sectors, and finally calculates the action time of each vector and designs the switching sequences by means of the cost function. The experimental results show that the proposed control strategy can quickly regulate the midpoint potential balance, and the current harmonic content is reduced to 3.5%.
- 29 May 2025
- Published by Springer Nature in Research Square
Open AccessThree-vector Model Predictive Control without Weight Coefficient based on Three-phase Neutral Point Clamped Inverter
Three-phase three-level neutral point clamped inverters are widely used in new energy fields such as photovoltaic power generation and wind power generation by virtue of their multilevel topology. The traditional three-vector model predictive control can solve the problems of current harmonics and unfixed switching frequency that exist in the single-vector model predictive control, but the traditional three-vector model predictive control still has the problems of large computation and difficult design of weighting factors. Based on this, this paper proposes a three-vector model predictive current control without weighting factors. The method firstly selects the voltage vectors by dividing the sectors to eliminate the weighting factors, secondly adopts the principle of non-differential beat control to obtain the reference voltage and the optimal sectors, and finally calculates the action time of each vector and designs the switching sequences by means of the cost function. The experimental results show that the proposed control strategy can quickly regulate the midpoint potential balance, and the current harmonic content is reduced to 3.5%.
- Open Access
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 33049-33061
Hybrid Model Flux Observer for PMSM Sensorless Control System Considering Parameter Disturbances and Measurement Noise
The hybrid model flux observer integrates the advantages of the voltage and current models to improve its control performance. However, at low speeds, the observer is more sensitive to the noise present in the measurement signals, causing the observation results to deviate from the actual values, and the situation of parameter mismatch will pose a serious challenge to the stability of the control system. Through mathematical derivation in this paper, the influence degree of resistance and inductance parameters on the observation angle error at different rotational speeds is obtained, and it is proposed to introduce an improved extended state observer to compensate for the system parameter disturbances to enhance the system robustness. By constructing a state equation considering measurement noise and analyzing the Bode diagram in this paper, it is concluded that the improved extended state observer, compared to the traditional observer, can reduce the sensitivity to high-frequency measurement noise and improve the estimation performance of low-frequency disturbances, and its stability conditions are derived. Finally, comparison experiments of the starting process, load mutation, parameter mutation and different flux observer methods under different load conditions are designed. The experimental results show that this control strategy, in the low-speed domain, can enhance the system’s resistance to parameter disturbances, improve the measurement accuracy of the system, and effectively suppress the measurement noise existing in the system, verifying the effectiveness and feasibility of this control strategy.
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 33049-33061
Open AccessHybrid Model Flux Observer for PMSM Sensorless Control System Considering Parameter Disturbances and Measurement Noise
The hybrid model flux observer integrates the advantages of the voltage and current models to improve its control performance. However, at low speeds, the observer is more sensitive to the noise present in the measurement signals, causing the observation results to deviate from the actual values, and the situation of parameter mismatch will pose a serious challenge to the stability of the control system. Through mathematical derivation in this paper, the influence degree of resistance and inductance parameters on the observation angle error at different rotational speeds is obtained, and it is proposed to introduce an improved extended state observer to compensate for the system parameter disturbances to enhance the system robustness. By constructing a state equation considering measurement noise and analyzing the Bode diagram in this paper, it is concluded that the improved extended state observer, compared to the traditional observer, can reduce the sensitivity to high-frequency measurement noise and improve the estimation performance of low-frequency disturbances, and its stability conditions are derived. Finally, comparison experiments of the starting process, load mutation, parameter mutation and different flux observer methods under different load conditions are designed. The experimental results show that this control strategy, in the low-speed domain, can enhance the system’s resistance to parameter disturbances, improve the measurement accuracy of the system, and effectively suppress the measurement noise existing in the system, verifying the effectiveness and feasibility of this control strategy.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 2410-2421
Model-Free Predictive Control With Super-Twisting Observer of Single-Phase Neutral-Clamped H-Bridge Cascade Inverters With Fixed Switching Frequency
A continuous control set model-free predictive control (CCS-MFPC) algorithm study based on single-phase neutral-clamped H-bridge cascade (CHB-NPC) inverters is proposed to address the problems of unfixed switching frequency and parameter mismatch in finite control set model predictive control (FCS-MPC). Firstly, in order to achieve a fixed switching frequency, three voltage vectors are employed in each control cycle, with the number of applications inversely proportional to their respective cost functions. The 27 switching vectors are combined into a sequence of 32 switching vectors from the consideration of both the reduction of switching action as well as the balance of the neutral point potential. Secondly, the effect of neutral point potential on system performance is investigated, and multi-objective prediction is used to balance the neutral point potential effectively by adding the neutral point potential difference to the cost function. Finally, in order to solve the parameter dependence problem of model prediction, a ultralocal model of single-phase CHB-NPC inverter is established, and a super-twisting sliding mode observer (ST-SMO) is designed to estimate the centralized perturbation, which makes the controller more parametrically robust. The corresponding experimental platform is built to demonstrate the correctness and superiority of the proposed method.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 2410-2421
Model-Free Predictive Control With Super-Twisting Observer of Single-Phase Neutral-Clamped H-Bridge Cascade Inverters With Fixed Switching Frequency
A continuous control set model-free predictive control (CCS-MFPC) algorithm study based on single-phase neutral-clamped H-bridge cascade (CHB-NPC) inverters is proposed to address the problems of unfixed switching frequency and parameter mismatch in finite control set model predictive control (FCS-MPC). Firstly, in order to achieve a fixed switching frequency, three voltage vectors are employed in each control cycle, with the number of applications inversely proportional to their respective cost functions. The 27 switching vectors are combined into a sequence of 32 switching vectors from the consideration of both the reduction of switching action as well as the balance of the neutral point potential. Secondly, the effect of neutral point potential on system performance is investigated, and multi-objective prediction is used to balance the neutral point potential effectively by adding the neutral point potential difference to the cost function. Finally, in order to solve the parameter dependence problem of model prediction, a ultralocal model of single-phase CHB-NPC inverter is established, and a super-twisting sliding mode observer (ST-SMO) is designed to estimate the centralized perturbation, which makes the controller more parametrically robust. The corresponding experimental platform is built to demonstrate the correctness and superiority of the proposed method.
- 6 June 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (8) , 5153-5164
A Simplified single-phase neutral-clamped H-bridge cascade converter FCS-MPC control
- 6 June 2024
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (8) , 5153-5164
A Simplified single-phase neutral-clamped H-bridge cascade converter FCS-MPC control
- Open Access
- 13 May 2024
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 18 (8) , 849-858
Research on cascaded multilevel converters for dual motor drive systems based on a nine‐switch converter
In order to address the issues of complexity, high cost, large volume, and low reliability associated with traditional H‐bridge cascaded converters when operating under high voltage, high capacity, and dual electric motor loads, the authors propose the utilisation of a nine‐switch converter as an alternative to the conventional H‐bridge converter for implementing cascaded multilevel converters in dual electric motor drive systems. After conducting an analysis and research on the topology and operational control strategy of cascaded multilevel converters based on the nine‐switch converter, a design is presented using six individual nine‐switch converter units to develop a cascaded multilevel converter capable of driving two 3 MW asynchronous electric motors at a 6 kV voltage level. Simulation verification is performed, and a scaled‐down prototype is built for experimental validation. The results demonstrate that, in comparison to traditional H‐bridge cascaded converters, the proposed cascaded multilevel converter can effectively drive dual electric motors at the same or different frequencies while reducing the number of switches to 1/4, the total transformer windings to 1/2, and Direct Current‐side capacitors to 1/6. This improvement enhances system reliability, portability, and load adaptability, thus offering increased versatility in dual electric motor drive applications.
- 13 May 2024
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 18 (8) , 849-858
Open AccessResearch on cascaded multilevel converters for dual motor drive systems based on a nine‐switch converter
In order to address the issues of complexity, high cost, large volume, and low reliability associated with traditional H‐bridge cascaded converters when operating under high voltage, high capacity, and dual electric motor loads, the authors propose the utilisation of a nine‐switch converter as an alternative to the conventional H‐bridge converter for implementing cascaded multilevel converters in dual electric motor drive systems. After conducting an analysis and research on the topology and operational control strategy of cascaded multilevel converters based on the nine‐switch converter, a design is presented using six individual nine‐switch converter units to develop a cascaded multilevel converter capable of driving two 3 MW asynchronous electric motors at a 6 kV voltage level. Simulation verification is performed, and a scaled‐down prototype is built for experimental validation. The results demonstrate that, in comparison to traditional H‐bridge cascaded converters, the proposed cascaded multilevel converter can effectively drive dual electric motors at the same or different frequencies while reducing the number of switches to 1/4, the total transformer windings to 1/2, and Direct Current‐side capacitors to 1/6. This improvement enhances system reliability, portability, and load adaptability, thus offering increased versatility in dual electric motor drive applications.