Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Laura Micheli has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Interferon‐γ Mitigates Oxaliplatin‐Induced Neurotoxicity: Analogies With Connexin 43

    by Alessandra Toti, Valentina Ferrara, Elena Lucarini, Laura Micheli, Clara Ciampi, Francesco Margiotta, Daniel Venturi, Carmen Parisio, Elisabetta Gerace, Lorenzo Curti, et al.

    Aims: Chemotherapy‐induced neuropathy is a major side effect of platinum‐based drugs such as oxaliplatin. Given the context‐dependent pro‐inflammatory or neuroprotective actions of interferon‐γ (IFN‐γ), this study investigated its role in an in vitro model of oxaliplatin‐induced neurotoxicity (OIPN). Methods: Rat organotypic spinal cord slices were exposed to oxaliplatin to model chemotherapy‐induced neurotoxicity responses in vitro. IFN‐γ cytotoxicity was assessed at 6 and 24 h. Neurotoxicity, inflammatory mediators, neurotrophic factors, and markers of glial and neuronal activation were analyzed by biochemical and immunohistochemical assays. Connexin 43 (Cx43) was assessed using Gap19 and Gap27 to probe hemichannel and gap‐junction contributions. Electrophysiological recordings characterized neuronal excitability. Results: IFN‐γ (6.5–200 ng/mL) was non‐toxic and, at 65 ng/mL, significantly reduced oxaliplatin‐induced neurotoxicity, decreasing LDH release and suppressing pro‐inflammatory mediators (CCL2, SerpinA3N, CGRP, substance P, c‐Fos). IFN‐γ modulated its signaling by reducing IFNγR and increasing IRF1 expression. It prevented oxaliplatin‐induced overexpression of neurotrophic factors and reduced glial and neuronal hyperactivation markers, preserving neuronal integrity. IFN‐γ reduced Cx43 expression and hemichannel activity, and Gap19 reproduced selected protective effects. Electrophysiology showed attenuation of oxaliplatin‐induced neuronal hyperexcitability. Conclusion: IFN‐γ attenuates oxaliplatin‐induced neurotoxic responses in an in vitro spinal cord model. The parallel reduction in Cx43 expression and hemichannel activity supports further investigation of Cx43 signaling as a candidate pharmacological target in OIPN.

  • Fragility Curves for Highway Embankment Slope Stability under Extreme Rainfall

    by Ege Can Kurter, Mohammad Sadik Khan, Laura Micheli, Austin R.J. Downey, Jasim Imran


  • Track 5: Design of Interconnected Infrastructure Systems for Resilient and Sustainable Communities

    by Teresa Vangeli, Laura Micheli, Mehrshad Ketabdar, Scott Campbell, Brian McSweeney, Amit Joshi, Chris Horiuchi

    Resilient and sustainable infrastructures, including buildings, bridges, and lifeline systems, play a central role in the socio-economic developm |

  • Life‐cycle cost optimization of wind‐excited tall buildings using surrogate models

    by Laura Micheli, Alice Alipour, Simon Laflamme

    Summary: As buildings become taller and slender, they become more sensitive to wind‐induced vibrations. Commonly used solutions to mitigate wind‐induced vibrations are structural system modifications and integration of supplemental damping devices. This paper presents a procedure to optimize the structural system and the damping device configuration with the goal of reducing wind‐induced vibrations. The performance of the building is expressed in terms of life‐cycle cost (LCC), allowing to consider not only the initial costs associated with the integration of wind‐induced vibration mitigation system but also the lifetime savings due to vibration suppression. The proposed procedure employs a set of Kriging surrogate models to analyze a large number of different structural properties/damping device characteristics. The combination that minimizes the LCC is taken as the optimal configuration. The procedure is demonstrated on a wind‐sensitive 39‐story building equipped with passive dampers. Results demonstrated that the accuracy of the Kriging surrogate models depends on the number of input variables considered, with an average root mean square error of 2.5% for the floors without dampers and 5% for the floors equipped with damping devices, respectively. It was also demonstrated that optimal stiffness–damping device configuration and LCC depend on the assumed cost of the structural system modifications.


  • Multiple-Surrogate Models for Probabilistic Performance Assessment of Wind-Excited Tall Buildings under Uncertainties

    by Laura Micheli, Alice Alipour, Simon Laflamme

    Performance-based design (PBD) is becoming a benchmark approach for design and performance assessment of civil structures because it facilitates communication between stakeholders and design professionals with decision metrics such as economic losses, downtime, and probabilistic cost functions. However, to reliably estimate the response of a building, it is necessary to consider uncertainties in structural parameters and external load characteristics, which makes the probabilistic assessment phase of PBD time consuming and often impractical. In wind-excited tall buildings, this aspect is combined with the long duration of typical wind events (in the order of hours) and the time required to conduct a single numerical simulation, further increasing the computational demand of the uncertainty analysis. As a solution, this paper presents a novel multiple-surrogate models framework for the probabilistic assessment of wind-excited tall buildings. In the proposed framework, the structural system is decomposed into a set of subsystems and multiple-surrogate models are used to map the uncertain building dynamic properties and wind load characteristics to its structural response, expressed in terms of peak floor acceleration and maximum story drift ratio. The proposed approach is demonstrated on a 40-story building, located in Boston, Massachusetts, and exposed to synthetic wind load time histories. The accuracy of the multiple-surrogate models to estimate the structural response of the building is first evaluated. Then, an application of the multiple-surrogate models to the cost assessment of the case study building is presented to demonstrate the capabilities of the proposed approach to probabilistically assess the performance of a structure and its potential integration in PBD. Results show that using the multiple-surrogate models framework represents a viable solution to handle the large dimensional probabilistic assessment of wind-excited tall buildings under uncertainties in dynamic properties and wind load characteristics.


  • Kriging-Based Design for Robust High-Performance Control Systems

    by Laura Micheli, Simon Laflamme

    High-performance control systems (HPCS) are sophisticated vibration-mitigation devices that include active, semiactive, and hybrid systems. HPCS leverage feedback mechanisms to dynamically adjust the damping force in response to motion, offering a good mitigation performance over a wide excitation bandwidth. These damping systems are attractive for multihazard mitigation of civil structures. However, the application of HPCS necessitates the design and integration of a closed-loop control system that can be susceptible to local failure or reduction in performance in the form of, for example, malfunctions of HPCS components, noisy measurements, wear, aging, and power unavailability. It follows that these sources of uncertainties may cause concerns and impede the wide acceptability and deployment of HPCS. A solution is to enhance the robustness of the closed-loop configuration through, for example, added redundancies and/or more robust, yet more expensive, components. In this paper, a Kriging-based design procedure is presented enabling the robust design of closed-loop control systems. The design procedure consists of constructing a Kriging surrogate that maps uncertainties to structural performance, and using that surrogate to identify the most influential sources of uncertainties. After, these identified uncertainties are made more robust in order to decrease the variance in the HPCS performance over the lifetime of the structure. The performance of the HPCS is directly quantified through a life cycle cost analysis to obtain probability distributions on the expected financial impacts. The proposed procedure is demonstrated on a numerically simulated 39-story structure exposed to wind loads. Uncertainties in both the HPCS configuration (i.e., damping devices and sensors) and external load are considered. Results demonstrate that the proposed framework can be used to substantially improve the robustness of the closed-loop system. Also, through a comparison against a robust passive-viscous case, it is shown that robustly designed HPCS significantly outperform a passive system in terms of vibration mitigation and life cycle costs.


  • Life-Cycle Cost Evaluation Strategy for High-Performance Control Systems under Uncertainties

    by Laura Micheli, Liang Cao, Simon Laflamme, Alice Alipour

    High-performance control systems (HPCSs), including active, hybrid, and semiactive control strategies, can perform over a wide excitation bandwidth and are therefore good candidates for multihazard mitigation. However, the number of HPCS applications in the field is very limited. This is likely due to the perceived higher costs of installation, maintenance, possible malfunction, and lack of tools to financially justify their implementation. Such financial justifications could be conducted through life-cycle cost (LCC) analysis, but would result in a computationally demanding task due to the very large number of simulations required given the large number of uncertainties. In this paper, two sets of methods for conducting LCC analyses are compared and their performance is assessed as a function of LCC estimation accuracy and computational requirements. The first set is based on deterministic scenarios and on the simulation of all possible scenarios; it is termed “what-if analysis.” Variations of the what-if method are investigated, where the simulations are conducted only for the most likely scenarios, termed “most-likely (ML)” analysis. The second set is based on stochastic scenarios and on Monte-Carlo (MC) analysis. Variations of the MC method are investigated, one based on the coefficient of variation of output data and one proposed by the authors based on the convergence of the estimated costs, termed bounded MC. A demonstration of the LCC analysis methodology is conducted where an HPCS is used for the mitigation of seismic-induced vibrations on a five-story structure. Uncertainties under consideration include sensor failure, mechanical wear, tear, and seismic events. Results are compared against the uncontrolled structure and a passive viscous strategy, and demonstrate that (1) the LCC methodology can be used to financially justify the utilization on an HPCS; and (2) the bounded MC method leads to accurate cost estimations using a lower number of simulations.