Diego Conde-Cid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Diego Conde-Cid has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Juan Manuel Antolín-Rodríguez
Departamento de Ciencias Agroforestales, ETSIIAA, Universidad de Valladolid, Avenida de Madrid 44, 34004 Palencia, Spain
1 shared publication - María Soto-Herranz
Department of Agroforestry Sciences, ETSIIAA, University of Valladolid, Avenida de Madrid 44, 34004 Palencia, Spain
1 shared publication - Matias B. Vanotti
Agricultural Research Service, Coastal Plains Soil, Water and Plant Research Center, United States Department of Agriculture, 2611 W. Lucas St., Florence, SC 29501, USA
1 shared publication - Mercedes Sánchez-Báscones
Department of Agroforestry Sciences, ETSIIAA, University of Valladolid, Avenida de Madrid 44, 34004 Palencia, Spain
1 shared publication
Latest Publications
- Open Access
- 16 June 2019
- Published by MDPI AG in Environments
- Vol. 6 (6) , 70
Effect of the Type of Gas-Permeable Membrane in Ammonia Recovery from Air
Animal production is one of the largest contributors to ammonia emissions. A project, “Ammonia Trapping”, was designed to recover gaseous ammonia from animal barns in Spain. Laboratory experiments were conducted to select a type of membrane most suitable for gaseous ammonia trapping. Three types of gas-permeable membranes (GPM), all made of expanded polytetrafluoroethylene (ePTFE), but with different diameter (3.0 to 8.6 mm), polymer density (0.45 to 1.09), air permeability (2 to 40 L·min−1·cm2), and porosity (5.6 to 21.8%) were evaluated for their effectiveness to recover gas phase ammonia. The ammonia evolved from a synthetic solution (NH4Cl + NaHCO3 + allylthiourea), and an acidic solution (1 N H2SO4) was used as the ammonia trapping solution. Replicated tests were performed simultaneously during a period of 7 days with a constant flow of acidic solution circulating through the lumen of the tubular membrane. The ammonia recovery yields were higher with the use of membranes of greater diameter and corresponding surface area, but they were not affected by the large differences in material density, porosity, air permeability, and wall thickness in the range evaluated. A higher fluid velocity of the acidic solution significantly increased—approximately 3 times—the mass NH3–N recovered per unit of membrane surface area and time (N-flux), from 1.7 to 5.8 mg N·cm−2·d−1. Therefore, to optimize the effectiveness of GPM system to capture gaseous ammonia, the appropriate velocity of the circulating acidic solution should be an important design consideration.
- 16 June 2019
- Published by MDPI AG in Environments
- Vol. 6 (6) , 70
Open AccessEffect of the Type of Gas-Permeable Membrane in Ammonia Recovery from Air
Animal production is one of the largest contributors to ammonia emissions. A project, “Ammonia Trapping”, was designed to recover gaseous ammonia from animal barns in Spain. Laboratory experiments were conducted to select a type of membrane most suitable for gaseous ammonia trapping. Three types of gas-permeable membranes (GPM), all made of expanded polytetrafluoroethylene (ePTFE), but with different diameter (3.0 to 8.6 mm), polymer density (0.45 to 1.09), air permeability (2 to 40 L·min−1·cm2), and porosity (5.6 to 21.8%) were evaluated for their effectiveness to recover gas phase ammonia. The ammonia evolved from a synthetic solution (NH4Cl + NaHCO3 + allylthiourea), and an acidic solution (1 N H2SO4) was used as the ammonia trapping solution. Replicated tests were performed simultaneously during a period of 7 days with a constant flow of acidic solution circulating through the lumen of the tubular membrane. The ammonia recovery yields were higher with the use of membranes of greater diameter and corresponding surface area, but they were not affected by the large differences in material density, porosity, air permeability, and wall thickness in the range evaluated. A higher fluid velocity of the acidic solution significantly increased—approximately 3 times—the mass NH3–N recovered per unit of membrane surface area and time (N-flux), from 1.7 to 5.8 mg N·cm−2·d−1. Therefore, to optimize the effectiveness of GPM system to capture gaseous ammonia, the appropriate velocity of the circulating acidic solution should be an important design consideration.