Maki Okamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maki Okamoto has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Christian Butter
Department of Cardiology, Heart Center Brandenburg, Bernau, Germany
1 shared publication- Christian Butter
Department of Cardiology, Immanuel Clinic Bernau, Heart Center Brandenburg, Bernau, Germany
1 shared publication Claudius Jacobshagen
Heart Center, University of Göttingen, Göttingen, Germany
1 shared publicationCornelia Deutsch
Institute for Pharmacology and Preventive Medicine, Cloppenburg, Germany
1 shared publication- Derk Frank
Department of Internal Medicine III, Cardiology and Critical Care, University Hospital Schleswig-Holstein , Campus Kiel, Kiel
1 shared publication Emi Kanaya
Department of Surgery and Science, Faculty of Medicine, Academic Assembly, University of Toyama, Toyama 9300194, Japan
1 shared publication
Latest Publications
- Open Access
- 1 July 2021
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2021 (7) , rjab241
Immediate one-stage breast reconstruction for an 85-year-old breast cancer patient using deep inferior epigastric perforator flap surgery
The deep inferior epigastric perforator (DIEP) flap is widely recognized as safe for use as a first-choice option in autologous tissue breast reconstruction; however, DIEP is often not performed for breast reconstruction in the elderly. We report a case of an 85-year-old woman who underwent DIEP flap reconstruction. Immediate reconstruction was performed after mastectomy. The patient successfully underwent DIEP flap reconstruction with no complications. Other options for reconstruction include a latissimus dorsi flap, a transverse rectus abdominis flap and implant-based reconstruction. DIEP flap reconstruction was performed, which does not cause muscle damage and provides sufficient volume. To our knowledge, this study is the first to report DIEP breast reconstruction in a patient over 85 years of age. This case demonstrates the usefulness of DIEP flap reconstruction for elderly patients.
- 1 July 2021
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2021 (7) , rjab241
Open AccessImmediate one-stage breast reconstruction for an 85-year-old breast cancer patient using deep inferior epigastric perforator flap surgery
The deep inferior epigastric perforator (DIEP) flap is widely recognized as safe for use as a first-choice option in autologous tissue breast reconstruction; however, DIEP is often not performed for breast reconstruction in the elderly. We report a case of an 85-year-old woman who underwent DIEP flap reconstruction. Immediate reconstruction was performed after mastectomy. The patient successfully underwent DIEP flap reconstruction with no complications. Other options for reconstruction include a latissimus dorsi flap, a transverse rectus abdominis flap and implant-based reconstruction. DIEP flap reconstruction was performed, which does not cause muscle damage and provides sufficient volume. To our knowledge, this study is the first to report DIEP breast reconstruction in a patient over 85 years of age. This case demonstrates the usefulness of DIEP flap reconstruction for elderly patients.
- Open Access
- 1 September 2019
- Published by BMJ in Open Heart
- Vol. 6 (2) , e001082
Balloon-expandable transfemoral transcatheter aortic valve implantation with or without predilation: findings from the prospective EASE-IT TF multicentre registry
Background Predilation of the native valve has long been deemed necessary in transfemoral transcatheter aortic valve implantation (TF-TAVI), despite little trial evidence to support its clinical use. As most evidence is derived from retrospective analyses of observational studies, we conducted a two-armed, prospective multicentre registry. Methods Patients undergoing TF-TAVI with the Edwards SAPIEN 3 valve, with or without balloon aortic valvuloplasty (BAV), were included and their procedural characteristics, short-term safety and short-term efficacy outcomes compared. We hypothesised that BAV may be safely omitted in many patients and omission could be associated with procedural benefits. Results Overall, 196 consecutive patients underwent TF-TAVI, 56 with BAV and 140 without. The mean age was 81.2±6.2 years, and the mean logistic EuroSCORE I was 17.1±13.6. Device success according to Valve Academic Research Consortium-2 (VARC-2) was achieved in 96.4%. The median procedural duration was shorter without BAV (56 min vs 90 min; p=0.001), as was fluoroscopy time (10 min vs 13 min; p=0.001). The need for balloon postdilation was less frequent in patients without BAV (15.7% vs 30.4%, p=0.029). There was no difference in the proportion of patients meeting the VARC-2 defined composite safety endpoint at 30 days (9.3% without vs 8.9% with BAV; adjusted OR (adjOR) 2.55; 95% CI 0.56 to 18.84) and at 6 months (15.2% without vs 16.4% with BAV; adjOR 1.66; 95% CI 0.49 to 6.55). Conclusions In the majority of patients, BAV can be safely omitted from the TAVI procedure without adverse effects. The omission of BAV is associated with shorter procedural duration and could be advantageous for the majority of patients. Trial registration number NCT02760771.
- 1 September 2019
- Published by BMJ in Open Heart
- Vol. 6 (2) , e001082
Open AccessBalloon-expandable transfemoral transcatheter aortic valve implantation with or without predilation: findings from the prospective EASE-IT TF multicentre registry
Background Predilation of the native valve has long been deemed necessary in transfemoral transcatheter aortic valve implantation (TF-TAVI), despite little trial evidence to support its clinical use. As most evidence is derived from retrospective analyses of observational studies, we conducted a two-armed, prospective multicentre registry. Methods Patients undergoing TF-TAVI with the Edwards SAPIEN 3 valve, with or without balloon aortic valvuloplasty (BAV), were included and their procedural characteristics, short-term safety and short-term efficacy outcomes compared. We hypothesised that BAV may be safely omitted in many patients and omission could be associated with procedural benefits. Results Overall, 196 consecutive patients underwent TF-TAVI, 56 with BAV and 140 without. The mean age was 81.2±6.2 years, and the mean logistic EuroSCORE I was 17.1±13.6. Device success according to Valve Academic Research Consortium-2 (VARC-2) was achieved in 96.4%. The median procedural duration was shorter without BAV (56 min vs 90 min; p=0.001), as was fluoroscopy time (10 min vs 13 min; p=0.001). The need for balloon postdilation was less frequent in patients without BAV (15.7% vs 30.4%, p=0.029). There was no difference in the proportion of patients meeting the VARC-2 defined composite safety endpoint at 30 days (9.3% without vs 8.9% with BAV; adjusted OR (adjOR) 2.55; 95% CI 0.56 to 18.84) and at 6 months (15.2% without vs 16.4% with BAV; adjOR 1.66; 95% CI 0.49 to 6.55). Conclusions In the majority of patients, BAV can be safely omitted from the TAVI procedure without adverse effects. The omission of BAV is associated with shorter procedural duration and could be advantageous for the majority of patients. Trial registration number NCT02760771.
- 18 June 2019
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 94 (2) , 285-288
Technical aspects of a successful transvascular retrieval of an acutely dislodged WaveCrest® left atrial appendage occluder
Percutaneous left atrial appendage (LAA) closure is an alternative therapy in patients with atrial fibrillation who are not suitable for anticoagulation. However, device embolization is one of the notable complications which inevitably requires catheter or surgical retrieval. In addition to previously reported Watchman® or AMULET® occluder embolization, here we report the first case of a WaveCrest® occluder dislodgement which was successfully removed by transcatheter technique. Instead of using the well‐known snaring technique, we used a “wiring and ballooning technique” for retrieval. Considering its specific architecture without having hooks or feet where suitable for grasping, this technique is an option for retrieving WaveCrest® devices.
- 18 June 2019
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 94 (2) , 285-288
Technical aspects of a successful transvascular retrieval of an acutely dislodged WaveCrest® left atrial appendage occluder
Percutaneous left atrial appendage (LAA) closure is an alternative therapy in patients with atrial fibrillation who are not suitable for anticoagulation. However, device embolization is one of the notable complications which inevitably requires catheter or surgical retrieval. In addition to previously reported Watchman® or AMULET® occluder embolization, here we report the first case of a WaveCrest® occluder dislodgement which was successfully removed by transcatheter technique. Instead of using the well‐known snaring technique, we used a “wiring and ballooning technique” for retrieval. Considering its specific architecture without having hooks or feet where suitable for grasping, this technique is an option for retrieving WaveCrest® devices.