Giuseppe Brunetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Giuseppe Brunetti has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Caterina Ciminelli
Optoelectronics Laboratory, Politecnico Di Bari, Bari, Italy
50 shared publications - Francesco Dell’oLio
Politecnico di Bari
19 shared publications - Mario Nicola Armenise
Optoelectronics Laboratory, Department of Electrical and Information Engineering, Politecnico di Bari, Bari, Italy
11 shared publications Donato Conteduca
York University, York, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
10 shared publicationsMario N. Armenise
10 shared publications- Giuseppe Coviello
Optoelectronics Laboratory, Politecnico Di Bari, Bari, Italy
9 shared publications
Latest Publications
- Open Access
- 14 August 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (8) , 439
Ultra-Broadband Metasurface Absorber Enabled by a Central-Bar-Coupled Split-Disk Dimer
A hybrid metasurface absorber (MSA) based on a central-bar-coupled split-disk dimer is proposed and numerically investigated for high-resolution refractive-index sensing in the near-infrared spectral region. The metasurface consists of silicon nitride dielectric resonators integrated with a gold plasmonic layer, enabling strong electromagnetic confinement, enhanced light–matter interaction, and ultra-narrow resonant features within the 1000–1400 nm wavelength range. The optimized structure supports multiple resonant modes under both x- and y-polarized excitation, producing sharp reflection dips with full-width-at-half-maximum values as low as 0.58 nm and quality factors reaching 2007. Refractive-index sensing performance was evaluated by varying the aqueous superstrate refractive index from 1.33 to 1.35, resulting in bulk sensitivities up to 860 nm/RIU under normal incidence. The angular response was further analyzed for incidence angles up to 5°, revealing polarization-dependent resonance splitting and the emergence of additional high-Q resonant branches under oblique excitation. Several angularly induced resonances exhibit narrower linewidths than those observed at normal incidence while preserving high refractive-index sensitivity up to 870 nm/RIU. Electric-field distributions confirm strong field localization near the dielectric boundaries and coupling regions, validating the hybrid resonant mechanism responsible for the enhanced spectral selectivity and sensing performance. The proposed MSA provides a promising platform for compact and ultrasensitive biosensing applications.
- 14 August 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (8) , 439
Open AccessUltra-Broadband Metasurface Absorber Enabled by a Central-Bar-Coupled Split-Disk Dimer
A hybrid metasurface absorber (MSA) based on a central-bar-coupled split-disk dimer is proposed and numerically investigated for high-resolution refractive-index sensing in the near-infrared spectral region. The metasurface consists of silicon nitride dielectric resonators integrated with a gold plasmonic layer, enabling strong electromagnetic confinement, enhanced light–matter interaction, and ultra-narrow resonant features within the 1000–1400 nm wavelength range. The optimized structure supports multiple resonant modes under both x- and y-polarized excitation, producing sharp reflection dips with full-width-at-half-maximum values as low as 0.58 nm and quality factors reaching 2007. Refractive-index sensing performance was evaluated by varying the aqueous superstrate refractive index from 1.33 to 1.35, resulting in bulk sensitivities up to 860 nm/RIU under normal incidence. The angular response was further analyzed for incidence angles up to 5°, revealing polarization-dependent resonance splitting and the emergence of additional high-Q resonant branches under oblique excitation. Several angularly induced resonances exhibit narrower linewidths than those observed at normal incidence while preserving high refractive-index sensitivity up to 870 nm/RIU. Electric-field distributions confirm strong field localization near the dielectric boundaries and coupling regions, validating the hybrid resonant mechanism responsible for the enhanced spectral selectivity and sensing performance. The proposed MSA provides a promising platform for compact and ultrasensitive biosensing applications.
- Open Access
- 10 June 2026
- Published by IOP Publishing in Journal of Optics
- Vol. 28 (6)
In-plane reconfigurable beamforming for optical inter-satellite links based on PCM metasurface
We present a planar beamforming metasurface that, unlike conventional architectures, generates optical beams through in-plane excitation rather than out-of-plane illumination. This configuration simplifies fabrication, enhances scalability, and enables cost-effective integration of all transceiver components. The device achieves a ± 30° field of view with an 4° beamwidth and no sidelobes, making it particularly suitable for compact free-space optical communication systems. Energy efficiency is achieved through the integration of non-volatile Sb2Se3 phase-change materials, which significantly reduce power consumption while satisfying the stringent Size, Weight, and Power constraints of NewSpace missions. The metasurface employs only 18 meta-atoms with a maximum length of 2 µm, minimizing the energy required for beam steering and enabling wide-angle control via partial crystallization. Numerical simulations predict ultra-low switching energy (2.18 nJ per event) and a total worst-case consumption of 0.35 W, orders of magnitude lower than conventional tuning mechanisms. Far-field analysis confirms stable, well-collimated beam propagation, supporting the feasibility of the proposed metasurface architecture for intersatellite optical links.
- 10 June 2026
- Published by IOP Publishing in Journal of Optics
- Vol. 28 (6)
Open AccessIn-plane reconfigurable beamforming for optical inter-satellite links based on PCM metasurface
We present a planar beamforming metasurface that, unlike conventional architectures, generates optical beams through in-plane excitation rather than out-of-plane illumination. This configuration simplifies fabrication, enhances scalability, and enables cost-effective integration of all transceiver components. The device achieves a ± 30° field of view with an 4° beamwidth and no sidelobes, making it particularly suitable for compact free-space optical communication systems. Energy efficiency is achieved through the integration of non-volatile Sb2Se3 phase-change materials, which significantly reduce power consumption while satisfying the stringent Size, Weight, and Power constraints of NewSpace missions. The metasurface employs only 18 meta-atoms with a maximum length of 2 µm, minimizing the energy required for beam steering and enabling wide-angle control via partial crystallization. Numerical simulations predict ultra-low switching energy (2.18 nJ per event) and a total worst-case consumption of 0.35 W, orders of magnitude lower than conventional tuning mechanisms. Far-field analysis confirms stable, well-collimated beam propagation, supporting the feasibility of the proposed metasurface architecture for intersatellite optical links.
- Open Access
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Tri-Sensor dToF Architecture for Contactless Neonatal Respiratory Monitoring with Edge-Based Multi-View Fusion
Early detection of respiratory instability in neonates requires reliable, contactless monitoring solutions capable of operating in crib-scale environments without physical attachment to the patient. This work presents a tri-sensor direct Time-of-Flight (dToF) architecture for contactless neonatal respiratory monitoring, based on three 8×8 multizone infrared depth sensors arranged to provide multi-view geometric coverage. The proposed system integrates centroid-based displacement tracking with amplitude-driven multi-view fusion executed on an STM32F401 microcontroller, enabling fully embedded edge processing. Respiratory motion is extracted from localized depth variations within the 100–350 mm range using spatial filtering and band-limited temporal analysis. The weighted fusion strategy dynamically prioritizes the sensor exhibiting the highest oscillatory signal quality, enhancing robustness under viewpoint changes and partial occlusions. Experimental validation was conducted using a programmable mechanical neonatal model reproducing thoracic displacements between 5 and 20 mm, including simulated supine, lateral, and apnea-like conditions. In addition, preliminary measurements on healthy adult subjects were performed to verify the capability of the proposed sensing approach to detect respiratory motion on real human surfaces under realistic conditions, including both bare and clothed configurations. Results demonstrate stable respiratory rate estimation across tested configurations while maintaining low computational complexity compatible with real-time embedded operation. Although clinical validation on neonates remains future work, the proposed architecture establishes a system-level framework for robust contactless respiratory monitoring based on geometric redundancy and lightweight edge-based fusion.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Open AccessA Tri-Sensor dToF Architecture for Contactless Neonatal Respiratory Monitoring with Edge-Based Multi-View Fusion
Early detection of respiratory instability in neonates requires reliable, contactless monitoring solutions capable of operating in crib-scale environments without physical attachment to the patient. This work presents a tri-sensor direct Time-of-Flight (dToF) architecture for contactless neonatal respiratory monitoring, based on three 8×8 multizone infrared depth sensors arranged to provide multi-view geometric coverage. The proposed system integrates centroid-based displacement tracking with amplitude-driven multi-view fusion executed on an STM32F401 microcontroller, enabling fully embedded edge processing. Respiratory motion is extracted from localized depth variations within the 100–350 mm range using spatial filtering and band-limited temporal analysis. The weighted fusion strategy dynamically prioritizes the sensor exhibiting the highest oscillatory signal quality, enhancing robustness under viewpoint changes and partial occlusions. Experimental validation was conducted using a programmable mechanical neonatal model reproducing thoracic displacements between 5 and 20 mm, including simulated supine, lateral, and apnea-like conditions. In addition, preliminary measurements on healthy adult subjects were performed to verify the capability of the proposed sensing approach to detect respiratory motion on real human surfaces under realistic conditions, including both bare and clothed configurations. Results demonstrate stable respiratory rate estimation across tested configurations while maintaining low computational complexity compatible with real-time embedded operation. Although clinical validation on neonates remains future work, the proposed architecture establishes a system-level framework for robust contactless respiratory monitoring based on geometric redundancy and lightweight edge-based fusion.
- Open Access
- 19 May 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (2)
A compact SOI based high-resolution broadband RF beamformer with phase change material aided programmability
The future of wireless communication depends on broadband, high-frequency operation, where microwave photonic beamformers have shown remarkable potential to overcome the bandwidth and loss limitations of electronic systems. However, achieving a compact, squintfree, and energy-efficient broadband beamformer with high-resolution steering remains a key challenge. Here, we present a numerically validated 7-bit optical switchable delay-line (OSDL) beamformer on a standard silicon-on-insulator (SOI) platform that leverages lowloss phase change materials (PCMs) for compact, energy-efficient programmability. The localized and non-volatile tuning of PCM enables a compact footprint of 2.5×3.1 mm² and supports 128 squint-free beam directions over a 20 GHz bandwidth (up to 40 GHz). The nonvolatile nature of PCM halves the number of switching operations compared with conventional thermo-optic tuning, reducing energy consumption while maintaining performance. Additionally, carrier-suppressed dual sideband modulation removes the need for optical filtering as well as halves the modulation bandwidth. Statistical analysis confirms excellent robustness, showing negligible degradation under ±10 nm fabrication variations. These results highlight the potential of PCM-assisted photonic beamformers for scalable, energy-efficient 5/6G and satellite communication systems.
- 19 May 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (2)
Open AccessA compact SOI based high-resolution broadband RF beamformer with phase change material aided programmability
The future of wireless communication depends on broadband, high-frequency operation, where microwave photonic beamformers have shown remarkable potential to overcome the bandwidth and loss limitations of electronic systems. However, achieving a compact, squintfree, and energy-efficient broadband beamformer with high-resolution steering remains a key challenge. Here, we present a numerically validated 7-bit optical switchable delay-line (OSDL) beamformer on a standard silicon-on-insulator (SOI) platform that leverages lowloss phase change materials (PCMs) for compact, energy-efficient programmability. The localized and non-volatile tuning of PCM enables a compact footprint of 2.5×3.1 mm² and supports 128 squint-free beam directions over a 20 GHz bandwidth (up to 40 GHz). The nonvolatile nature of PCM halves the number of switching operations compared with conventional thermo-optic tuning, reducing energy consumption while maintaining performance. Additionally, carrier-suppressed dual sideband modulation removes the need for optical filtering as well as halves the modulation bandwidth. Statistical analysis confirms excellent robustness, showing negligible degradation under ±10 nm fabrication variations. These results highlight the potential of PCM-assisted photonic beamformers for scalable, energy-efficient 5/6G and satellite communication systems.
- 1 May 2026
- Published by Springer Nature
- p. 281-287
Development of ISFET Array Architectures for Real-Time Multiparametric Analysis
- 1 May 2026
- Published by Springer Nature
- p. 281-287
Development of ISFET Array Architectures for Real-Time Multiparametric Analysis
- Open Access
- 23 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (9) , 4162
Efficient Nanoparticle Sorting Through an Optofluidic Waveguide Splitter for Early Cancer Diagnosis: A Numerical Study
In this work, we present a numerical proof-of-concept study of a device for nanoparticle sorting, targeting size ranges relevant to exosome-like dimensions (typically 40–200 nm), which remains challenging for passive sorting techniques. The system consists of three silicon waveguides embedded in a CYTOP layer and arranged in a two-step directional-coupler configuration, integrated with a microchannel that carries a water-based buffer as the carrier fluid, transporting the suspended nanoparticles. Three-dimensional Finite Element Method (3D-FEM) simulations were performed, incorporating both optical and hydrodynamic forces to track particle dynamics within the microchannel and demonstrate controlled, size-selective particle deflection. First, numerical simulations show that nanospheres with diameters ranging from 500 nm to 700 nm can be effectively separated by the transverse trapping force at a 4:1 power-splitting ratio. Then, to extend the concept toward smaller size ranges, a bifurcated microchannel is introduced, enabling fluid-assisted transport in low-optical-field regions and allowing reliable separation of particles with smaller diameters (between 200 nm and 400 nm), accompanied by an 8:1 power-splitting ratio. These results demonstrate, within a numerical framework, the feasibility of an integrated photonic–microfluidic approach for size-selective nanoparticle sorting. The proposed strategy may support future pre-processing steps in liquid biopsy workflows, particularly for enriching nanoscale components such as exosome-sized vesicles, rather than constituting a direct diagnostic tool.
- 23 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (9) , 4162
Open AccessEfficient Nanoparticle Sorting Through an Optofluidic Waveguide Splitter for Early Cancer Diagnosis: A Numerical Study
In this work, we present a numerical proof-of-concept study of a device for nanoparticle sorting, targeting size ranges relevant to exosome-like dimensions (typically 40–200 nm), which remains challenging for passive sorting techniques. The system consists of three silicon waveguides embedded in a CYTOP layer and arranged in a two-step directional-coupler configuration, integrated with a microchannel that carries a water-based buffer as the carrier fluid, transporting the suspended nanoparticles. Three-dimensional Finite Element Method (3D-FEM) simulations were performed, incorporating both optical and hydrodynamic forces to track particle dynamics within the microchannel and demonstrate controlled, size-selective particle deflection. First, numerical simulations show that nanospheres with diameters ranging from 500 nm to 700 nm can be effectively separated by the transverse trapping force at a 4:1 power-splitting ratio. Then, to extend the concept toward smaller size ranges, a bifurcated microchannel is introduced, enabling fluid-assisted transport in low-optical-field regions and allowing reliable separation of particles with smaller diameters (between 200 nm and 400 nm), accompanied by an 8:1 power-splitting ratio. These results demonstrate, within a numerical framework, the feasibility of an integrated photonic–microfluidic approach for size-selective nanoparticle sorting. The proposed strategy may support future pre-processing steps in liquid biopsy workflows, particularly for enriching nanoscale components such as exosome-sized vesicles, rather than constituting a direct diagnostic tool.
- Open Access
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (6) , 2283-2291
Boosting SiN Ring Resonator Linewidth Lower Than 10 fm Through Optical Bistability
Ring resonator features are of paramount importance in various optical systems. In this context, the enhancement of linewidth, and in turn the Q-factor, stands as the pivotal achievement. However, a distinctive trait of ring resonators lies in the delicate balance between the linewidth and resonance depth; an improvement in the linewidth may entail a compromise in the resonance extinction ratio. In this context, here a silicon nitride ring resonator is presented, boosting a record-breaking linewidth for a single-mode ring resonator lower than 10 fm (Q-factor > 108), alongside an extinction ratio of 5 dB. This significant improvement of linewidth is experimentally demonstrated by harnessing the optical bistability effect through the combination of low optical losses (in dB/m) and the Kerr effect, suppressing the detrimental impact of self-heating-induced dissipation. This breakthrough holds several advantages, primarily in the realm of selectivity and signal-to-noise ratio, thereby paving the way for its utilization for data storage as well as numerous sensing applications.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 44 (6) , 2283-2291
Open AccessBoosting SiN Ring Resonator Linewidth Lower Than 10 fm Through Optical Bistability
Ring resonator features are of paramount importance in various optical systems. In this context, the enhancement of linewidth, and in turn the Q-factor, stands as the pivotal achievement. However, a distinctive trait of ring resonators lies in the delicate balance between the linewidth and resonance depth; an improvement in the linewidth may entail a compromise in the resonance extinction ratio. In this context, here a silicon nitride ring resonator is presented, boosting a record-breaking linewidth for a single-mode ring resonator lower than 10 fm (Q-factor > 108), alongside an extinction ratio of 5 dB. This significant improvement of linewidth is experimentally demonstrated by harnessing the optical bistability effect through the combination of low optical losses (in dB/m) and the Kerr effect, suppressing the detrimental impact of self-heating-induced dissipation. This breakthrough holds several advantages, primarily in the realm of selectivity and signal-to-noise ratio, thereby paving the way for its utilization for data storage as well as numerous sensing applications.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 4017413
Real-Time SNR-Adaptable Muscle Activation Detection Using an Embedded Shallow Neural Network and Frequency–Amplitude sEMG Features
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 4017413
Open AccessReal-Time SNR-Adaptable Muscle Activation Detection Using an Embedded Shallow Neural Network and Frequency–Amplitude sEMG Features
- Open Access
- 1 January 2026
- Published by Walter de Gruyter GmbH in Nanotechnology Reviews
- Vol. 15 (1)
Numerical investigation of IgG sensing through nanoscale topological-assisted metasurface for liquid biopsy
Topological photonics offers tightly confined, defect-immune optical modes ideal for biosensing, where sensitivity, spectral resolution, and fabrication tolerance must coexist. Conventional Guided-Mode Resonances (GMRs) sensors typically exhibit limited Q -factors, whereas high- Q photonic crystal cavities require complex fabrication and lack robustness. To bridge this gap, we present a refractive-index sensor based on a Jackiw-Rebbi topological resonance at the interface of two oppositely phased 2D GMR gratings. Under normal-incidence transverse-magnetic excitation, the device achieves Q > 1,600, bulk sensitivity of 97 nm/RIU, and a figure of merit (sensitivity × Q ) of 1.7 × 10 5 across 870–970 nm. The enhanced tolerance to fabrication deviations, together with high- Q , high-amplitude resonant behavior and a fully planar, photolithography-compatible geometry, makes the proposed topological GMR platform a strong candidate for next-generation label-free biosensing implementations.
- 1 January 2026
- Published by Walter de Gruyter GmbH in Nanotechnology Reviews
- Vol. 15 (1)
Open AccessNumerical investigation of IgG sensing through nanoscale topological-assisted metasurface for liquid biopsy
Topological photonics offers tightly confined, defect-immune optical modes ideal for biosensing, where sensitivity, spectral resolution, and fabrication tolerance must coexist. Conventional Guided-Mode Resonances (GMRs) sensors typically exhibit limited Q -factors, whereas high- Q photonic crystal cavities require complex fabrication and lack robustness. To bridge this gap, we present a refractive-index sensor based on a Jackiw-Rebbi topological resonance at the interface of two oppositely phased 2D GMR gratings. Under normal-incidence transverse-magnetic excitation, the device achieves Q > 1,600, bulk sensitivity of 97 nm/RIU, and a figure of merit (sensitivity × Q ) of 1.7 × 10 5 across 870–970 nm. The enhanced tolerance to fabrication deviations, together with high- Q , high-amplitude resonant behavior and a fully planar, photolithography-compatible geometry, makes the proposed topological GMR platform a strong candidate for next-generation label-free biosensing implementations.
- 5 December 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 198
Innovative optical beam steering network for sub-meter satellite SAR
- 5 December 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 198
Innovative optical beam steering network for sub-meter satellite SAR