Kwai Hei Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kwai Hei Li has a total of 174 co-authors. Here are the top co-authors by number of shared publications:
Yumeng Luo
Southern University of Science and Technology
23 shared publicationsLiang Chen
Foshan Electrical and Lighting Company Ltd., Foshan, China
20 shared publications- Zhiqin Chu
Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, China
20 shared publications Xiaoshuai An
School of Microelectronics, Southern University of Science and Technology, Shenzhen, CHINA
18 shared publications- Hoi Wai Choi
The University of Hong Kong Pokfulam Road
17 shared publications Jixiang Jing
Department of Electrical and Electronic Engineering
14 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 47 (11) , 2235-2238
Monolithic GaN Opto-Thermal Logic Array With On-Chip Optical and Thermal Inputs
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 47 (11) , 2235-2238
Monolithic GaN Opto-Thermal Logic Array With On-Chip Optical and Thermal Inputs
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6905-6910
Monolithic GaN-on-Sapphire Optofluidic Devices for Droplet Logic Operations
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6905-6910
Monolithic GaN-on-Sapphire Optofluidic Devices for Droplet Logic Operations
- 11 September 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (37) , 12471-12480
Ion-Selective GaN Optopairs with Rapid Response and High Stability for Intelligent Biomimetic Sensing
Ion concentration variation can indicate dynamic physiological metabolism and environmental media changes. Although electrochemical biosensors with high sensitivity and selectivity are widely used, achieving rapid response and minimal signal drift remains challenging. Herein, a gallium nitride (GaN) chip was functionalized with an ion-selective membrane to enable highly sensitive, fast, and stable optical readout. During real-time continuous monitoring, a minimized response time of 0.15 s with high signal recovery was achieved, and the drift was reduced to about 0.5 μA/h and 0.3 μA/h for Na+ and K+, respectively. To reduce the cross-interference in mixed ion analysis, a dual-channel ion decoding algorithm was implemented to improve the accuracy. The sensor was integrated into a flexible platform for real-time sweat electrolytes monitoring during exercise and further applied to a robotic fish for biomimetic detection of abnormal ion-concentration hazard zones and closed-loop obstacle avoidance, demonstrating its potential for wearable health monitoring and environmental perception.
- 11 September 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (37) , 12471-12480
Ion-Selective GaN Optopairs with Rapid Response and High Stability for Intelligent Biomimetic Sensing
Ion concentration variation can indicate dynamic physiological metabolism and environmental media changes. Although electrochemical biosensors with high sensitivity and selectivity are widely used, achieving rapid response and minimal signal drift remains challenging. Herein, a gallium nitride (GaN) chip was functionalized with an ion-selective membrane to enable highly sensitive, fast, and stable optical readout. During real-time continuous monitoring, a minimized response time of 0.15 s with high signal recovery was achieved, and the drift was reduced to about 0.5 μA/h and 0.3 μA/h for Na+ and K+, respectively. To reduce the cross-interference in mixed ion analysis, a dual-channel ion decoding algorithm was implemented to improve the accuracy. The sensor was integrated into a flexible platform for real-time sweat electrolytes monitoring during exercise and further applied to a robotic fish for biomimetic detection of abnormal ion-concentration hazard zones and closed-loop obstacle avoidance, demonstrating its potential for wearable health monitoring and environmental perception.
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (5) , 2574-2581
Tailoring the Sensitivity-Range Tradeoff in Monolithic InGaN/GaN Temperature Sensing Devices via Indium Content Engineering
Monolithic integration of InGaN-based optoelectronics offers a promising platform for compact sensing devices, yet the influence of key material parameters such as indium content on temperature-sensing performance remains unexplored. This work systematically studies the effect of the indium concentration in InGaN/GaN multiquantum wells (MQWs) on the performance of monolithically integrated light-emitting diode (LED)–photodetector (PD) devices. Devices with indium fractions from 0.137 to 0.302, yielding room-temperature emission from 431 to 540 nm, are fabricated and characterized from $0~^{\circ }$ C to $220~^{\circ }$ C. The sensing mechanism is driven by the temperature-dependent spectral overlap between the LED emission and PD responsivity, influenced by thermal bandgap narrowing, thermal depolarization, and carrier dynamics. Experimental results demonstrate that higher indium content extends the linear operational range (from 0– $140~^{\circ }$ C to 0– $220~^{\circ }$ C) but reduces sensitivity (from 0.441%/°C to 124%/°C), revealing a direct design tradeoff. All devices exhibit high reversibility, stability, and linearity (R ${}^{{2}} \gt 0.98$ ). This study identifies indium concentration as a critical parameter for tailoring the sensitivity-range compromise, providing essential design guidelines for optimizing monolithic III-nitride optoelectronic devices.
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (5) , 2574-2581
Tailoring the Sensitivity-Range Tradeoff in Monolithic InGaN/GaN Temperature Sensing Devices via Indium Content Engineering
Monolithic integration of InGaN-based optoelectronics offers a promising platform for compact sensing devices, yet the influence of key material parameters such as indium content on temperature-sensing performance remains unexplored. This work systematically studies the effect of the indium concentration in InGaN/GaN multiquantum wells (MQWs) on the performance of monolithically integrated light-emitting diode (LED)–photodetector (PD) devices. Devices with indium fractions from 0.137 to 0.302, yielding room-temperature emission from 431 to 540 nm, are fabricated and characterized from $0~^{\circ }$ C to $220~^{\circ }$ C. The sensing mechanism is driven by the temperature-dependent spectral overlap between the LED emission and PD responsivity, influenced by thermal bandgap narrowing, thermal depolarization, and carrier dynamics. Experimental results demonstrate that higher indium content extends the linear operational range (from 0– $140~^{\circ }$ C to 0– $220~^{\circ }$ C) but reduces sensitivity (from 0.441%/°C to 124%/°C), revealing a direct design tradeoff. All devices exhibit high reversibility, stability, and linearity (R ${}^{{2}} \gt 0.98$ ). This study identifies indium concentration as a critical parameter for tailoring the sensitivity-range compromise, providing essential design guidelines for optimizing monolithic III-nitride optoelectronic devices.
- Open Access
- 20 March 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (12) , eaea8318
Uncovering piezoelectric effect in polycrystalline diamond membranes
Diamonds have been regarded as nonpiezoelectric materials for more than one century. Here, we uncover a notable piezoelectric effect in ultrathin and ultraflexible polycrystalline diamond membranes. Our experiments show that the piezoelectricity depends on membrane thickness, with peak response (exhibiting a piezoelectric voltage coefficient of ~82.2 millivolt meters per newton that surpasses many conventional piezoelectric materials) seen in ~5-micrometer-thick membranes. First-principles calculations reveal that the unexpected piezoelectricity in polycrystalline membranes originates from local asymmetry induced by grain boundaries, which alter the electric polarization within a finite region near the boundary during deformation. This finding together with the outstanding properties of our membranes is expected to catalyze the exploration and development of diamond-based applications in energy harvesting, intelligent sensing, and wearable electronics.
- 20 March 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (12) , eaea8318
Open AccessUncovering piezoelectric effect in polycrystalline diamond membranes
Diamonds have been regarded as nonpiezoelectric materials for more than one century. Here, we uncover a notable piezoelectric effect in ultrathin and ultraflexible polycrystalline diamond membranes. Our experiments show that the piezoelectricity depends on membrane thickness, with peak response (exhibiting a piezoelectric voltage coefficient of ~82.2 millivolt meters per newton that surpasses many conventional piezoelectric materials) seen in ~5-micrometer-thick membranes. First-principles calculations reveal that the unexpected piezoelectricity in polycrystalline membranes originates from local asymmetry induced by grain boundaries, which alter the electric polarization within a finite region near the boundary during deformation. This finding together with the outstanding properties of our membranes is expected to catalyze the exploration and development of diamond-based applications in energy harvesting, intelligent sensing, and wearable electronics.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (12) , 7014-7019
Cantilever-Assisted GaN Integrated Optical Devices for Vector Magnetic Field Detection
This study introduces a compact optomagnetic device for vector magnetic field detection, addressing the limitations of conventional optical systems in portability and integration. The millimeter-scale device integrates a GaN optoelectronic chip with a PDMS-CaCO3 composite cantilever coated with silver gel, enabling bidirectional magnetic field detection via optomechanical coupling. Through the optimization of cantilever geometry and CaCO3 doping for balanced reflectivity and mechanical compliance, the integrated device exhibits sensitivities of 96 nA/mT and 67 nA/mT across field ranges of ±510mT. Experimental validation reveals linear response characteristics, rapid dynamics (163 ms response time), and stable operation over 1000 cycles. Demonstrations include 2-D field mapping and photomagnetic rotation tracking, highlighting potential in non-contact control and spatial diagnostics. The design offers enhanced robustness, eliminates reliance on external optical components, and supports scalable manufacturing processes, making it suitable for industrial, biomedical, and portable sensing scenarios.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (12) , 7014-7019
Cantilever-Assisted GaN Integrated Optical Devices for Vector Magnetic Field Detection
This study introduces a compact optomagnetic device for vector magnetic field detection, addressing the limitations of conventional optical systems in portability and integration. The millimeter-scale device integrates a GaN optoelectronic chip with a PDMS-CaCO3 composite cantilever coated with silver gel, enabling bidirectional magnetic field detection via optomechanical coupling. Through the optimization of cantilever geometry and CaCO3 doping for balanced reflectivity and mechanical compliance, the integrated device exhibits sensitivities of 96 nA/mT and 67 nA/mT across field ranges of ±510mT. Experimental validation reveals linear response characteristics, rapid dynamics (163 ms response time), and stable operation over 1000 cycles. Demonstrations include 2-D field mapping and photomagnetic rotation tracking, highlighting potential in non-contact control and spatial diagnostics. The design offers enhanced robustness, eliminates reliance on external optical components, and supports scalable manufacturing processes, making it suitable for industrial, biomedical, and portable sensing scenarios.
- 9 October 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (45) , 16115-16122
Self-Powered, Ultrathin, Flexible, and Scalable Ultraviolet Detector Utilizing a Diamond–MoS 2 Heterojunction
The escalating demand for ultraviolet (UV) sensing necessitates detectors that are both environmentally and mechanically resilient. Diamond emerges as a highly promising material for next-generation UV detection due to its unique properties. However, conventional diamond-based UV detectors are constrained by rigid bulk architectures and a reliance on external power supplies, hindering their integration and complicating device design. To tackle these challenges, herein, we first demonstrate a large-scale, self-powered, and flexible diamond UV detector by heterogeneously integrating a MoS2 monolayer with an ultrathin, freestanding diamond membrane. The fabricated device operates at zero external bias and exhibits high responsivity and detectivity. Notably, mechanical bending enables strain-induced bandgap modulation of the diamond membrane, allowing dynamically tunable photoresponse─a capability absent in rigid diamond counterparts. To validate its practicality and scalability, a proof-of-concept UV imager was demonstrated. This newly developed configuration will undoubtedly open new routes toward scalable, integrable, and flexible UV sensing.
- 9 October 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (45) , 16115-16122
Self-Powered, Ultrathin, Flexible, and Scalable Ultraviolet Detector Utilizing a Diamond–MoS 2 Heterojunction
The escalating demand for ultraviolet (UV) sensing necessitates detectors that are both environmentally and mechanically resilient. Diamond emerges as a highly promising material for next-generation UV detection due to its unique properties. However, conventional diamond-based UV detectors are constrained by rigid bulk architectures and a reliance on external power supplies, hindering their integration and complicating device design. To tackle these challenges, herein, we first demonstrate a large-scale, self-powered, and flexible diamond UV detector by heterogeneously integrating a MoS2 monolayer with an ultrathin, freestanding diamond membrane. The fabricated device operates at zero external bias and exhibits high responsivity and detectivity. Notably, mechanical bending enables strain-induced bandgap modulation of the diamond membrane, allowing dynamically tunable photoresponse─a capability absent in rigid diamond counterparts. To validate its practicality and scalability, a proof-of-concept UV imager was demonstrated. This newly developed configuration will undoubtedly open new routes toward scalable, integrable, and flexible UV sensing.
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 36059-36063
GaN Optical Refractometer With Hemispherical Resin Lens
Refractive index (RI) sensing is critical for diverse applications, yet conventional optical approaches face limitations, including complex instrumentation and alignment requirements. In this work, a compact optical refractometer integrates a GaN-based chip with a resin lens. The device, fabricated via wafer-scale epitaxy and microfabrication, incorporates on-chip light-emitting diode and photodiode. A cost-effective molding technique enables the integration of a hemispherical resin lens, eliminating external components and enhancing optical coupling. Device characterization confirms robust electro-optical performance, with lens integration significantly enhancing optical coupling. Variations in the ambient RI modulate the total internal reflection at the lens interface, altering the light received by the on-chip detector. The sensor demonstrates a sensitivity of 69.36 μA/RIU across a broad RI range (1.3331–1.5405) and a resolution of 7.2 × 10⁻⁷ RIU. It exhibits rapid response (0.118 s) and recovery (0.140 s), along with excellent repeatability over 100 cycles. Real-time monitoring of glucose dilution dynamics and quantitative detection of honey adulteration validate its practicality. This compact, high-performance platform offers a promising solution for scalable RI sensing in biomedical, environmental, and food integrity applications.
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 36059-36063
GaN Optical Refractometer With Hemispherical Resin Lens
Refractive index (RI) sensing is critical for diverse applications, yet conventional optical approaches face limitations, including complex instrumentation and alignment requirements. In this work, a compact optical refractometer integrates a GaN-based chip with a resin lens. The device, fabricated via wafer-scale epitaxy and microfabrication, incorporates on-chip light-emitting diode and photodiode. A cost-effective molding technique enables the integration of a hemispherical resin lens, eliminating external components and enhancing optical coupling. Device characterization confirms robust electro-optical performance, with lens integration significantly enhancing optical coupling. Variations in the ambient RI modulate the total internal reflection at the lens interface, altering the light received by the on-chip detector. The sensor demonstrates a sensitivity of 69.36 μA/RIU across a broad RI range (1.3331–1.5405) and a resolution of 7.2 × 10⁻⁷ RIU. It exhibits rapid response (0.118 s) and recovery (0.140 s), along with excellent repeatability over 100 cycles. Real-time monitoring of glucose dilution dynamics and quantitative detection of honey adulteration validate its practicality. This compact, high-performance platform offers a promising solution for scalable RI sensing in biomedical, environmental, and food integrity applications.
- Open Access
- 5 September 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-10
GaN/PDMS-based opto-electro-mechanical tactile sensors
Tactile sensors are crucial in robotics and medical diagnostics, requiring precise real-time detection. However, the development of a compact sensor that can measure force across a wide range, with high resolution and rapid response along three axes, remains extremely limited. Herein, an opto-electro-mechanical tactile sensor is reported, utilizing a monolithically integrated GaN-based optochip with a fingerprint-patterned polydimethylsiloxane (PDMS) film. The sensor exhibits a linear response over a broad measurement range of ±100 mN for shear force and 0–200 mN for normal force, with a detection resolution of 0.07 mN. It also demonstrates fast response and recovery times of 0.85 ms and 0.82 ms, respectively. Experimental verification of its application in surface topography scanning and organ lesion assessment highlights its potential for enhancing robotic perception and medical diagnosis.
- 5 September 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-10
Open AccessGaN/PDMS-based opto-electro-mechanical tactile sensors
Tactile sensors are crucial in robotics and medical diagnostics, requiring precise real-time detection. However, the development of a compact sensor that can measure force across a wide range, with high resolution and rapid response along three axes, remains extremely limited. Herein, an opto-electro-mechanical tactile sensor is reported, utilizing a monolithically integrated GaN-based optochip with a fingerprint-patterned polydimethylsiloxane (PDMS) film. The sensor exhibits a linear response over a broad measurement range of ±100 mN for shear force and 0–200 mN for normal force, with a detection resolution of 0.07 mN. It also demonstrates fast response and recovery times of 0.85 ms and 0.82 ms, respectively. Experimental verification of its application in surface topography scanning and organ lesion assessment highlights its potential for enhancing robotic perception and medical diagnosis.