XWXuehua Wang

Xuehua Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xuehua Wang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Variable Parameter Series Compensation Method Featuring Fast Dynamic Response for Dual Active Bridge Converter in Battery Charging/Discharging Applications

    by Feng Wang, Xuehua Wang, Jialing Yuan, Xinbo Ruan

    The extended-phase-shift (EPS) modulated dual-active-bridge (DAB) converter has become prevalent in battery charging/discharging systems, where low overshoot and short settling time are critically required. However, wide variations in battery voltage and current and abrupt operating mode transitions tend to challenge the dynamic performance of the converter. In this article, a small-signal model is developed, the potential challenge due to the wide-range variations or abrupt mode transitions is evaluated, and a variable parameter series compensation (VPSC) method is proposed. The proposed method can adjust its parameters in real time according to the variations in battery voltage and current, making the dynamics of the EPS-DAB converter immune to the variations. For practical implementation, a polynomial-fit approximation is conducted to minimize the computational complexity. An execution-optimized flowchart is also provided. Experimental results on a 45-kW prototype demonstrate the effectiveness of the VPSC method. Even under the worst case when the battery voltage is 107 V and the battery current steps from 100 to −100 A, no overshoot arises and the settling time is less than 6 ms.


  • Novel High-Frequency Pulse Permutation Scheme for DC-Link Voltage Balance of CHB-Based PV Solid-State Transformer

    by Yuying He, Chuan Yao, Xuehua Wang, Jingxin Hu

    The cascaded H-bridge (CHB) based solid-state transformer is an attractive solution to integrate large-scale photovoltaic (PV) power plants into medium-voltage grids with high power quality in a controllable and scalable manner. The dc-link voltage balance of the CHB is critical to the lifespan of capacitors and semiconductor devices, grid-current quality, and the system's stable operation. However, with the conventional level-shifted pulsewidth modulation, the output power and dc-link voltage of each module are intrinsically imbalanced, which make the switching pulse permutation necessary. Although voltage balancing can be reclaimed using the pulse rotation scheme, the low permutation frequency in the existing methods increases the ripples in the dc-link voltages, which affects the maximum power point tracking efficiency. To tackle this challenge, a novel high-frequency pulse permutation scheme is proposed for the CHB-based PV solid-state transformer, and the implementation procedure based on an improved sorting method is provided. The proposed scheme can effectively ensure the dc-link voltage balance over a wide regulation range without the penalty of additional switching actions. The effectiveness of the proposed high-frequency pulse permutation scheme is validated with the experiments on a 3-kW prototype.


  • Graphical Impedance Reshaping Approach for LCL-Filtered Voltage Source Inverter

    by Xinyi Yu, Jin Wang, Xuehua Wang, Xinbo Ruan

    Impedance reshaping has proven to be effective to ensure the stability of the LCL -filtered voltage source inverters against the grid impedance variation. Lots of reshaping approaches have been developed to date. However, there lacks an intuitive approach for the engineers to quickly determine a proper one from various reshaping approaches. This letter proposes a graphical impedance reshaping approach, which can not only evaluate the existing reshaping ones, but also provide guidance to both explore the suitable reshaping ones for dissipativity up to the Nyquist frequency and tune the associated compensator parameters. The correctness of their theoretical analysis and the effectiveness of the proposed approach are verified by the experimental results.


  • Impact of Power Control Parameters on the Passivity of Grid-Forming Inverters

    by Yuying He, Guotao Wu, Xuehua Wang, Wen Zou

    The grid-forming (GFM) inverter, which has the function of supporting grid voltage/frequency, has drawn much attention. However, like the grid-following (GFL) inverter, the inverter-grid interaction also poses instability risk to the GFM inverter. To address the stability issue, the passivity-based approach has been widely applied to GFL inverters, and is proved to be effective and promising. In this paper, we applied the passivity-based approach to the GFM inverter and focuses on the impact of power control parameters on the system passivity. The findings will contribute to the controller parameter optimization of the GFM inverter.

  • A Synchronous Rectification Scheme for Three-Phase LLC Considering Phase Shedding

    by Shuaichen Guo, Xuehua Wang

    The three-phase LLC resonant converter has gained much attention in battery charger application due to its excellent characteristics such as automatic current sharing, increased power levels, and lower output capacitor current ripple. Moreover, three-phase LLC could improve the converter’s efficiency at light load through phase shedding, which is suitable for the absorption stage in charging cycle. However, phase shedding changes actual topology of the converter, which brings challenges to synchronous rectification (SR) scheme. To solve this issue, this paper presents a universal SR scheme for all operating modes of three-phase LLC considering phase shedding. Considering the characteristics of three operating modes and the differences of phase shedding strategy corresponding to every charging stage, how to generate driving signals for synchronous rectifier is discussed in detail. Finally, the effectiveness of the proposed scheme is verified by simulation results.


  • Passivity-Based Stability Analysis and Generic Controller Design for Grid-Forming Inverter

    by Guotao Wu, Yuying He, Hao Zhang, Xuehua Wang, Donghua Pan, Xinbo Ruan, Chuan Yao

    With the remarkable growth of renewable energy resources, the grid-forming (GFM) inverter with the function of grid voltage/frequency support attracts much attention. Due to the inverter-grid interaction, the stability of the GFM inverter is a critical issue. The passivity-based analysis approach, which was widely applied to the conventional grid-following inverter, has been proved to be promising. Yet, its application to the GFM inverter is still insufficient. To this end, this article conducts a comprehensive passivity-based analysis for the GFM inverter with single-loop voltage control. It finds that the two indices of the passivity-based stability criterion, i.e., the individual stability and the output impedance passivity, bring identical constraints on the voltage controller, and the passivity cannot be ensured with typical voltage controllers. To shrink the unexpected nonpassive frequency ranges, a generic grid-current feedforward scheme is explored, and the proper feedforward functions compatible with different voltage controllers are derived. With the proposed scheme, the passivity can be guaranteed up to the Nyquist frequency. Finally, experimental results from a 6-kVA prototype are provided to verify the theoretical analysis.


  • A General Graphical Method for Filter-Based Active Damping: Evaluation, Exploration, and Design

    by Cheng Wang, Donghua Pan, Xuehua Wang, Yuying He, Hao Zhang, Xinbo Ruan, Xia Chen

    Filter-based active damping is a promising solution to tackle the resonance hazard of LCL-filtered inverters. Although various methods have been developed it still lacks guidelines to evaluate and select them In this paper, a general graphical method is proposed to fill this void, and the desired phase regions of the damping filters for stabilization are identified. As a benchmark, the proposed method is used to evaluate the existing damping filters and further explore the proper ones on the robustness against the drift of LCL resonance frequency. It reveals that the low pass filter, the all-pass filter the delay filter, and the resonant-notch filter are less robust, and finds that the phase-lag filter, the notch filter with its notch frequency equaling one third of the sampling frequency, the quasi-notch filter and the bi-quad filter are highly robust. Taking the phase-lag filter as an example, the design guideline of the filter parameters is presented according to the proposed method Experiments tested on a 6-kW prototype validate the theoretical analysis.


  • Passivity-Oriented Impedance Shaping for LCL -Filtered Grid-Connected Inverters

    by Cheng Wang, Xuehua Wang, Yuying He, Donghua Pan, Hao Zhang, Xinbo Ruan, Xia Chen

    The passivity theory provides an effective way to tackle the instability due to the inverter-grid interaction, which tells that the system stability can be guaranteed if the grid impedance and the inverter output impedance are both passive. Since the grid impedance is generally passive, the system stability can be immune to the grid impedance variation if the inverter output impedance is also passive. This article develops a series and parallel impedance shaping method to ensure that the output impedance of the LCL -filtered grid-connected inverter is dissipative up to the Nyquist frequency. Since the inverter output impedance can be decomposed into two passive elements and one active element, its nondissipative property results from the latter, and thus the virtual series impedance shaping is introduced to cancel out the active element. Unfortunately, it poses impact on the low-frequency loop gain and system phase margin in the meantime. To alleviate this impact, a high-pass filter is inserted in the series impedance shaping function. Subsequently, a virtual parallel impedance is introduced to enhance the passivity robustness, such as against filter parameter variations. Moreover, the proposed method does not require any additional sensors. Experiments from a 6-kW prototype confirm the effectiveness of the proposed method.


  • Impact of Controller Saturation on Instability Behavior of Grid-Connected Inverters

    by Xuehua Wang, Yuying He, Kuang Qin, Hao Zhang, Donghua Pan, Xinbo Ruan, Qingfeng Zhou, Chuan Yao

    For the power-electronics-based power system, a kind of stable operation with constant-amplitude oscillation was often witnessed in the reported instability incidents. In some cases, the root is proved to be negative damping by the theoretical analysis based on the linear model and the impedance-based stability theory. However, the negative damped resonances should diverge. This leaves a void why the analysis result is not in accord with the field measurement. This article aims to provide a potential answer for the disaccord, i.e., the controller saturation which is commonly ignored in the modeling process due to its nonlinearity. The controller saturation is linearized by the describing function and the improved linear model is developed. By applying the generalized Nyquist stability criterion, the impact of the controller saturation on the instability behavior of grid-connected inverters is identified, which reveals the underlying mechanism of the constant-amplitude oscillation. The theoretical expectations are finally validated by the experimental results.


  • Harmonic Instability of LCL -Type Grid-Connected Inverter Caused by the Pole-Zero Cancellation: A Case Study

    by Xuehua Wang, Yuying He, Donghua Pan, Hao Zhang, Yixiao Ma, Xinbo Ruan

    Pole-zero cancellation technique has drawn much attention to tackle the filter resonance of the LCL -type grid-connected inverter for simplifying the stability-oriented design. However, its potential stability risk was rarely concerned. As one representative of this technique, the weighted average current (WAC) control is assessed. It is found that the LCL resonance in the state variable WAC is cancelled out by pole-zero cancellation, but the ones in some uncontrollable or unobservable state variables such as the grid current are still inherited, resulting in harmonic instability. From this perspective, this article appeals that this technique should be cautiously used or even avoided. An extended WAC control which avoids pole-zero cancellation is proposed accordingly. The theoretical expectations are finally validated by simulation and experimental results.