RYRong Yan

Rong Yan

*This is an algorithmically generated author record based on publicly available information.

Rong Yan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Machine learning modeling on acoustic emission leak detection of metal-sealed pressure vessel

    by Fen Li, Yuefeng Li, Rong Yan, Yunlong Wu, Ziqiang Zhang, Xuehao Xu

    The metal-sealed pressure vessels are often used to provide a sealed pressure environment for storage and transportation of gas or liquid. Once the leakage occurs, it will cause serious financial loss and even casualties. Therefore, it is very necessary to monitor the operation state of the metal-sealed pressure vessel in time. This paper describes a real-time detecting method for metal-sealed pressure vessels, which is based on a machine learning (ML) framework and acoustic emission (AE) signal. The result of leakage detection based on AE is susceptible to different factors, such as environmental noise, the material of detected pressure vessels, and the position of the AE sensor, these factors may lead to a poor detection result. To address these drawbacks, an effective ML model, the decision tree (DT) based on AE signals is presented. At the core of this methodology, a DT model was trained on over 20 thousand AE signal records for classifying the leak sections. The experimental result illustrated that the accuracy of the proposed model to detect leakage of the metal-sealed pressure vessel is 98.3%, F1 score is 0.98, which has significant advantages compared with the traditional method. Instead of tedious feature extraction, ML methods have the advantage of being simple and real-time.

  • Active Distribution System Synthesis via Unbalanced Graph Generative Adversarial Network

    by Rong Yan, Yuxuan Yuan, Zhaoyu Wang, Guangchao Geng, Quanyuan Jiang

    Real active distribution networks with associated smart meter (SM) data are critical for power researchers. However, it is practically difficult for researchers to obtain such comprehensive datasets from utilities due to privacy concerns. To bridge this gap, an implicit generative model with Wasserstein GAN objectives, namely unbalanced graph generative adversarial network (UG-GAN), is designed to generate synthetic three-phase unbalanced active distribution system connectivity. The basic idea is to learn the distribution of random walks both over a real-world system and across each phase of line segments, capturing the underlying local properties of an individual real-world distribution network and generating specific synthetic networks accordingly. Then, to create a comprehensive synthetic test case, a network correction and extension process is proposed to obtain time-series nodal demands and standard distribution grid components with realistic parameters, including distributed energy resources (DERs) and capacitor banks. A Midwest distribution system with 1-year SM data has been utilized to validate the performance of our method. Case studies with several power applications demonstrate that synthetic active networks generated by the proposed framework can mimic almost all features of real-world networks while avoiding the disclosure of confidential information.


  • Data-Driven Transient Stability Boundary Generation for Online Security Monitoring

    by Rong Yan, Guangchao Geng, Quanyuan Jiang

    Transient stability boundary (TSB) is an important tool in power system online security monitoring, but practically it suffers from high computational burden using state-of-the-art methods, such as time-domain simulation (TDS), with numerous scenarios taken into account (e.g., operating points (OPs) and N-1 contingencies). The purpose of this work is to establish a data-driven framework to generate sufficient critical samples close to the boundary within a limited time, covering all critical scenarios in current OP. Therefore, accurate TSB can be periodically refreshed by tracking current OP in time. The idea is to develop a search strategy to obtain more data samples near the stability boundary, while traverse the rest part with fewer samples. To achieve this goal, a specially designed transient index sensitivity based search strategy and critical scenarios selection mechanism are proposed, in order to find out the most representative scenarios and periodically update TSB for online monitoring. Two case studies validate effectiveness of the proposed method.


  • Dataless Text Classification with Pseudo Topic Representation

    by Rong Yan, Qi Chen, Guanglai Gao

    As for an automatic text classification approach, a large body of research on latent-topic based Dataless Text Classification (DTC) has been emerged in recent years. Perusing the candidate seed words or guaranteeing the quality of the category-topics is the core mission of this approach. However, few previous studies consider the quality of specific category-topics at the collection level instead at the document level, because not all topics are equally coherent or category sparsity. In this paper, we focus on alleviating the dilemma for the seed words selection problem in DTC by using pseudo text understanding. Differently from the existing latent-topic based DTC approach, we propose an unsupervised method named Pseudo Document Labeled Classification (PDLC). It extracts the most representative word list to capture the best latent semantic category-topic description. Experimental results indicate that our PDLC scheme achieves better classification accuracy without any labeled data or external resource.

  • Single-Ended Fault Location for Hybrid Transmission Line using Embedded Artificial Intelligence

    by Rong Yan, Guangchao Geng, Guoqiang Zeng, Quanyuan Jiang

    Fault line identification, phase selection, and exact location play a significant role in power system daily protection and maintenance. There is always a trade off between location accuracy and data acquisition cost (e.g., data communication time, measurement equipment cost) using state-of-the-art methods like steady-state phasor-based or traveling wave-based approaches for hybrid transmission line: overhead line combined with cable. The idea of this work is to construct a novel framework summarized as “train in the cloud and infer on the edge”, deploying the fault-location task on the edge of data source for distributed inference instead of sending measured data to a centralized cloud. To archive this goal, a modified long short-term memory (LSTM) network is trained in the cloud, covering various fault scenarios. Meanwhile, the trained model is imported on a small embedded artificial intelligence (e-AI) module equipped in fault recorder of the substation, in order to infer fault information using local single-ended measurements in real time. The performance of the proposed method is tested for various fault scenarios with satisfactory results in real time.


  • Fast Transient Stability Batch Assessment Using Cascaded Convolutional Neural Networks

    by Rong Yan, Guangchao Geng, Quanyuan Jiang, Yanglin Li

    Stability assessment is a regular routine in both power system planning and operation. It is computationally demanding using state-of-the-art approaches like time-domain simulation (TDS), as numerous scenarios (e.g., N-1 contingencies) have to be assessed for a large batch of contingencies. The purpose of this work is to determine stability conclusion before the simulator reaches the end of simulating time windows. Therefore, TDS can be terminated early so as to reduce the average simulation time for batch assessment without losses of accuracy. The idea is to develop a data-driven methodology to “learn” from existing TDS results in the batch and “infer” stability conclusions using current available TDS output. To achieve this goal, cascaded convolutional neural networks (CNNs) are designed to capture data from different TDS time intervals, extract features, predict stability probability and determine TDS termination. While accumulating more knowledge in batch processing, early termination criterion is refreshed continuously via feedback learning to terminate TDS increasingly earlier, with the increase of existing TDS results in the batch. Case studies in IEEE 39-bus and Polish 2383-bus system illustrate effectiveness of the proposed method.