Danielle L. Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Danielle L. Brown has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Michael Staup
Pathology Department, Charles River Laboratories, Durham, NC, USA
3 shared publications- Daniel Rudmann
Charles River Laboratories International, Inc., Wilmington, Massachusetts, USA
2 shared publications - Famke Aeffner
Amgen, Inc., South San Francisco, California, USA
2 shared publications - Aleksandra Zuraw
Charles River Laboratories International, Inc, United States
1 shared publication Anantharaman Muthuswamy
Regeneron Pharmaceuticals Inc, Tarrytown, NY, USA
1 shared publicationBhupinder Bawa
AbbVie, Preclinical Safety, North Chicago, IL, USA
1 shared publication
Latest Publications
- 1 June 2021
- Published by Elsevier in Toxicology Letters
- Vol. 344, 34-45
Neurotoxicity studies with a tropomyosin-related kinase A inhibitor, ASP7962, on the sympathetic and sensory nervous systems in rats
- 1 June 2021
- Published by Elsevier in Toxicology Letters
- Vol. 344, 34-45
Neurotoxicity studies with a tropomyosin-related kinase A inhibitor, ASP7962, on the sympathetic and sensory nervous systems in rats
- 29 December 2020
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 49  (4) , 773-783
Developing a Qualification and Verification Strategy for Digital Tissue Image Analysis in Toxicological Pathology
Digital tissue image analysis is a computational method for analyzing whole-slide images and extracting large, complex, and quantitative data sets. However, as with any analysis method, the quality of generated results is dependent on a well-designed quality control system for the entire digital pathology workflow. Such system requires clear procedural controls, appropriate user training, and involvement of specialists to oversee key steps of the workflow. The toxicologic pathologist is responsible for reporting data obtained by digital image analysis and therefore needs to ensure that it is correct. To accomplish that, they must understand the main parameters of the quality control system and should play an integral part in its conception and implementation. This manuscript describes the most common digital tissue image analysis end points and potential sources of analysis errors. In addition, it outlines recommended approaches for ensuring quality and correctness of results for both classical and machine-learning based image analysis solutions, as adapted from a recently proposed Food and Drug Administration regulatory framework for modifications to artificial intelligence/machine learning-based software as a medical device. These approaches are beneficial for any type of toxicopathologic study which uses the described end points and can be adjusted based on the intended use of the image analysis solution.
- 29 December 2020
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 49  (4) , 773-783
Developing a Qualification and Verification Strategy for Digital Tissue Image Analysis in Toxicological Pathology
Digital tissue image analysis is a computational method for analyzing whole-slide images and extracting large, complex, and quantitative data sets. However, as with any analysis method, the quality of generated results is dependent on a well-designed quality control system for the entire digital pathology workflow. Such system requires clear procedural controls, appropriate user training, and involvement of specialists to oversee key steps of the workflow. The toxicologic pathologist is responsible for reporting data obtained by digital image analysis and therefore needs to ensure that it is correct. To accomplish that, they must understand the main parameters of the quality control system and should play an integral part in its conception and implementation. This manuscript describes the most common digital tissue image analysis end points and potential sources of analysis errors. In addition, it outlines recommended approaches for ensuring quality and correctness of results for both classical and machine-learning based image analysis solutions, as adapted from a recently proposed Food and Drug Administration regulatory framework for modifications to artificial intelligence/machine learning-based software as a medical device. These approaches are beneficial for any type of toxicopathologic study which uses the described end points and can be adjusted based on the intended use of the image analysis solution.
- Open Access
- 2 December 2020
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 48  (8) , 965-980
Qualitative and Quantitative Neuropathology Approaches Using Magnetic Resonance Microscopy (Diffusion Tensor Imaging) and Stereology in a Hexachlorophene Model of Myelinopathy in Sprague-Dawley Rats
It is well established that hexachlorophene, which is used as an antibacterial agent, causes intramyelinic edema in humans and animal models. The hexachlorophene myelinopathy model, in which male Sprague-Dawley rats received 25 to 30 mg/kg hexachlorophene by gavage for up to 5 days, provided an opportunity to compare traditional neuropathology evaluations with magnetic resonance microscopy (MRM) findings. In addition, stereology assessments of 3 neuroanatomical sites were compared to quantitative measurements of similar structures by MRM. There were positive correlations between hematoxylin and eosin and luxol fast blue stains and MRM for identifying intramyelinic edema in the cingulum of corpus callosum, optic chiasm, anterior commissure (aca), lateral olfactory tracts, pyramidal tracts (py), and white matter tracts in the cerebellum. Stereology assessments were focused on the aca, longitudinal fasciculus of the pons, and py and demonstrated differences between control and treated rats, as was observed using MRM. The added value of MRM assessments was the ability to acquire qualitative 3-dimensional (3-D) images and obtain quantitative measurements of intramyelinic edema in 26 neuroanatomical sites in the intact brain. Also, diffusion tensor imaging (fractional anisotropy [FA]) indicated that there were changes in the cytoarchitecture of the white matter as detected by decreases in the FA in the treated compared to the control rats. This study demonstrates creative strategies that are possible using qualitative and quantitative assessments of potential white matter neurotoxicants in nonclinical toxicity studies. Our results lead us to the conclusion that volumetric analysis by MRM and stereology adds significant value to the standard 2-D microscopic evaluations.
- 2 December 2020
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 48  (8) , 965-980
Open AccessQualitative and Quantitative Neuropathology Approaches Using Magnetic Resonance Microscopy (Diffusion Tensor Imaging) and Stereology in a Hexachlorophene Model of Myelinopathy in Sprague-Dawley Rats
It is well established that hexachlorophene, which is used as an antibacterial agent, causes intramyelinic edema in humans and animal models. The hexachlorophene myelinopathy model, in which male Sprague-Dawley rats received 25 to 30 mg/kg hexachlorophene by gavage for up to 5 days, provided an opportunity to compare traditional neuropathology evaluations with magnetic resonance microscopy (MRM) findings. In addition, stereology assessments of 3 neuroanatomical sites were compared to quantitative measurements of similar structures by MRM. There were positive correlations between hematoxylin and eosin and luxol fast blue stains and MRM for identifying intramyelinic edema in the cingulum of corpus callosum, optic chiasm, anterior commissure (aca), lateral olfactory tracts, pyramidal tracts (py), and white matter tracts in the cerebellum. Stereology assessments were focused on the aca, longitudinal fasciculus of the pons, and py and demonstrated differences between control and treated rats, as was observed using MRM. The added value of MRM assessments was the ability to acquire qualitative 3-dimensional (3-D) images and obtain quantitative measurements of intramyelinic edema in 26 neuroanatomical sites in the intact brain. Also, diffusion tensor imaging (fractional anisotropy [FA]) indicated that there were changes in the cytoarchitecture of the white matter as detected by decreases in the FA in the treated compared to the control rats. This study demonstrates creative strategies that are possible using qualitative and quantitative assessments of potential white matter neurotoxicants in nonclinical toxicity studies. Our results lead us to the conclusion that volumetric analysis by MRM and stereology adds significant value to the standard 2-D microscopic evaluations.
- 23 October 2019
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 48  (2) , 277-294
Society of Toxicologic Pathology Digital Pathology and Image Analysis Special Interest Group Article*: Opinion on the Application of Artificial Intelligence and Machine Learning to Digital Toxicologic Pathology
Toxicologic pathology is transitioning from analog to digital methods. This transition seems inevitable due to a host of ongoing social and medical technological forces. Of these, artificial intelligence (AI) and in particular machine learning (ML) are globally disruptive, rapidly growing sectors of technology whose impact on the long-established field of histopathology is quickly being realized. The development of increasing numbers of algorithms, peering ever deeper into the histopathological space, has demonstrated to the scientific community that AI pathology platforms are now poised to truly impact the future of precision and personalized medicine. However, as with all great technological advances, there are implementation and adoption challenges. This review aims to define common and relevant AI and ML terminology, describe data generation and interpretation, outline current and potential future business cases, discuss validation and regulatory hurdles, and most importantly, propose how overcoming the challenges of this burgeoning technology may shape toxicologic pathology for years to come, enabling pathologists to contribute even more effectively to answering scientific questions and solving global health issues. [Box: see text]
- 23 October 2019
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 48  (2) , 277-294
Society of Toxicologic Pathology Digital Pathology and Image Analysis Special Interest Group Article*: Opinion on the Application of Artificial Intelligence and Machine Learning to Digital Toxicologic Pathology
Toxicologic pathology is transitioning from analog to digital methods. This transition seems inevitable due to a host of ongoing social and medical technological forces. Of these, artificial intelligence (AI) and in particular machine learning (ML) are globally disruptive, rapidly growing sectors of technology whose impact on the long-established field of histopathology is quickly being realized. The development of increasing numbers of algorithms, peering ever deeper into the histopathological space, has demonstrated to the scientific community that AI pathology platforms are now poised to truly impact the future of precision and personalized medicine. However, as with all great technological advances, there are implementation and adoption challenges. This review aims to define common and relevant AI and ML terminology, describe data generation and interpretation, outline current and potential future business cases, discuss validation and regulatory hurdles, and most importantly, propose how overcoming the challenges of this burgeoning technology may shape toxicologic pathology for years to come, enabling pathologists to contribute even more effectively to answering scientific questions and solving global health issues. [Box: see text]
- 20 June 2019
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 48  (1) , 37-48
Stereology of the Peripheral Nervous System
Qualitative histopathology has been the gold standard for evaluation of morphological tissue changes in all organ systems, including the peripheral nervous system. However, the human eye is not sensitive enough to detect small changes in quantity or size. Peripheral nervous system toxicity can manifest as subtle changes in neuron size, neuron number, axon size, number of myelinated or unmyelinated axons, or number of nerve fibers. Detection of these changes may be beyond the sensitivity of the human eye alone, necessitating quantitative approaches in some cases. Although 2-dimensional (2D) histomorphometry can provide additional information and is more sensitive than qualitative evaluation alone, the results are not always representative of the entire tissue and assumptions about the tissue can lead to bias, or inaccuracies, in the data. Design-based stereology provides 3D estimates of number, volume, surface area, or length, and stereological principles can be applied to peripheral nervous system tissues to obtain accurate and precise estimates, such as neuron number and size, axon number, and total intraepidermal nerve fiber length. This review describes practical stereological approaches to 3 compartments of the peripheral nervous system: ganglia, peripheral nerves, and intraepidermal nerve fibers.
- 20 June 2019
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 48  (1) , 37-48
Stereology of the Peripheral Nervous System
Qualitative histopathology has been the gold standard for evaluation of morphological tissue changes in all organ systems, including the peripheral nervous system. However, the human eye is not sensitive enough to detect small changes in quantity or size. Peripheral nervous system toxicity can manifest as subtle changes in neuron size, neuron number, axon size, number of myelinated or unmyelinated axons, or number of nerve fibers. Detection of these changes may be beyond the sensitivity of the human eye alone, necessitating quantitative approaches in some cases. Although 2-dimensional (2D) histomorphometry can provide additional information and is more sensitive than qualitative evaluation alone, the results are not always representative of the entire tissue and assumptions about the tissue can lead to bias, or inaccuracies, in the data. Design-based stereology provides 3D estimates of number, volume, surface area, or length, and stereological principles can be applied to peripheral nervous system tissues to obtain accurate and precise estimates, such as neuron number and size, axon number, and total intraepidermal nerve fiber length. This review describes practical stereological approaches to 3 compartments of the peripheral nervous system: ganglia, peripheral nerves, and intraepidermal nerve fibers.
- Open Access
- 1 June 2018
- Published by Elsevier in Bone Reports
- Vol. 8, 90-94
Decreased osteoprogenitor proliferation precedes attenuation of cancellous bone formation in ovariectomized rats treated with sclerostin antibody
- 1 June 2018
- Published by Elsevier in Bone Reports
- Vol. 8, 90-94
Open AccessDecreased osteoprogenitor proliferation precedes attenuation of cancellous bone formation in ovariectomized rats treated with sclerostin antibody
- 29 March 2017
- Published by Springer Nature
- p. 329-417
Immunopathology of the Hepatobiliary System
- 23 March 2017
- Published by SAGE Publications in Veterinary Pathology
- Vol. 54  (3) , 358-368
Practical Stereology Applications for the Pathologist
Qualitative histopathology is the gold standard for routine examination of morphological tissue changes in the regulatory or academic environment. The human eye is exceptional for pattern recognition but often cannot detect small changes in quantity. In cases where detection of subtle quantitative changes is critical, more sensitive methods are required. Two-dimensional histomorphometry can provide additional quantitative information and is quite useful in many cases. However, the provided data may not be referent to the entire tissue and, as such, it makes several assumptions, which are sources of bias. In contrast, stereology is design based rather than assumption based and uses stringent sampling methods to obtain accurate and precise 3-dimensional information using geometrical and statistical principles. Recent advances in technology have made stereology more approachable and practical for the pathologist in both regulatory and academic environments. This review introduces pathologists to the basic principles of stereology and walks the reader through some real-world examples for the application of these principles in the workplace.
- 23 March 2017
- Published by SAGE Publications in Veterinary Pathology
- Vol. 54  (3) , 358-368
Practical Stereology Applications for the Pathologist
Qualitative histopathology is the gold standard for routine examination of morphological tissue changes in the regulatory or academic environment. The human eye is exceptional for pattern recognition but often cannot detect small changes in quantity. In cases where detection of subtle quantitative changes is critical, more sensitive methods are required. Two-dimensional histomorphometry can provide additional quantitative information and is quite useful in many cases. However, the provided data may not be referent to the entire tissue and, as such, it makes several assumptions, which are sources of bias. In contrast, stereology is design based rather than assumption based and uses stringent sampling methods to obtain accurate and precise 3-dimensional information using geometrical and statistical principles. Recent advances in technology have made stereology more approachable and practical for the pathologist in both regulatory and academic environments. This review introduces pathologists to the basic principles of stereology and walks the reader through some real-world examples for the application of these principles in the workplace.
- Open Access
- 1 January 2017
- Published by Japanese Society of Toxicologic Pathology in Journal of Toxicologic Pathology
- Vol. 30  (3) , 183-191
Bias in image analysis and its solution: unbiased stereology
Although the human eye is excellent for pattern recognition, it often lacks the sensitivity to detect subtle changes in particle density. Because of this, quantitative evaluation may be required in some studies. A common type of quantitative assessment used for routine toxicology studies is two-dimensional histomorphometry. Although this technique can provide additional information about the tissue section being examined, it does not give information about the tissue as a whole. Furthermore, it produces biased (inaccurate) data that does not take into account the size, shape, or orientation of particles. In contrast, stereology is a technique that utilizes stringent sampling methods to obtain three-dimensional information about the entire tissue that is unbiased. The purpose of this review is to illuminate the sources of bias with two-dimensional morphometry, how it can affect the data, and how that bias is minimized with stereology.
- 1 January 2017
- Published by Japanese Society of Toxicologic Pathology in Journal of Toxicologic Pathology
- Vol. 30  (3) , 183-191
Open AccessBias in image analysis and its solution: unbiased stereology
Although the human eye is excellent for pattern recognition, it often lacks the sensitivity to detect subtle changes in particle density. Because of this, quantitative evaluation may be required in some studies. A common type of quantitative assessment used for routine toxicology studies is two-dimensional histomorphometry. Although this technique can provide additional information about the tissue section being examined, it does not give information about the tissue as a whole. Furthermore, it produces biased (inaccurate) data that does not take into account the size, shape, or orientation of particles. In contrast, stereology is a technique that utilizes stringent sampling methods to obtain three-dimensional information about the entire tissue that is unbiased. The purpose of this review is to illuminate the sources of bias with two-dimensional morphometry, how it can affect the data, and how that bias is minimized with stereology.