Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Isabelle Quidu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Derivation of New Orthonormal Basis Functions for Magnetic Detection of Submarine Telecommunications Cables

    by Khaled Hleis, Isabelle Quidu, Michel Legris, Alain Bertholom

    This paper presents a novel set of orthonormal basis functions (OBF) adapted for passive magnetic anomaly detection of underwater telecommunications cables carrying a DC current, extending Anderson's approach from dipole to cable detection. We derive two orthonormal basis functions for the magnetic field of an infinite straight cable and develop an optimal matched filter detector using the generalised likelihood ratio test. Experimental validation in both simulation and a lake environment demonstrates successful detection of the cable using an unmanned surface vehicle (USV)‐mounted triaxial magnetometer.

  • Open Access

    A Likelihood-Based Triangulation Method for Uncertainties in Through-Water Depth Mapping

    by Mohamed Ali Ghannami, Sylvie Daniel, Guillaume Sicot, Isabelle Quidu

    Coastal environments, which are crucial for economic and strategic reasons, heavily rely on accurate bathymetry for safe navigation and resource monitoring. Recent advancements in through-water photogrammetry have shown promise in mapping shallow waters efficiently. However, robust uncertainty modeling methods for these techniques, especially in challenging coastal environments, are lacking. This study introduces a novel likelihood-based approach for through-water photogrammetry, focusing on uncertainties associated with camera pose—a key factor affecting depth mapping accuracy. Our methodology incorporates probabilistic modeling and stereo-photogrammetric triangulation to provide realistic estimates of uncertainty in Water Column Depth (WCD) and Water–Air Interface (WAI) height. Using simulated scenarios for both drone and airborne surveys, we demonstrate that viewing geometry and camera pose quality significantly influence resulting uncertainties, often overshadowing the impact of depth itself. Our results reveal the superior performance of the likelihood ratio statistic in scenarios involving high attitude noise, high flight altitude, and complex viewing geometries. Notably, drone-based applications show particular promise, achieving decimeter-level WCD precision and WAI height estimations comparable to high-quality GNSS measurements when using large samples. These findings highlight the potential of drone-based surveys in producing more accurate bathymetric charts for shallow coastal waters. This research contributes to the refinement of uncertainty quantification in bathymetric charting and sets a foundation for future advancements in through-water surveying methodologies.


  • Open Access

    High contrast and resolution 3-D ultrasonography with a clinical linear transducer array scanned in a rotate-translate geometry

    by Théotim Lucas, Isabelle Quidu, S. Lori Bridal, Jerome Gateau

    We propose a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic-aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound platform. The rotate-translate scanning scheme increases the elevation angular aperture by pivoting the array [-45{\textdegree} to 45{\textdegree}] around its array axis (axis along the row of its elements) and then, scans the imaged object for each pivoted angle by translating the array perpendicularly to the rotation axis. A theoretical basis is presented so that the angular and translational scan sampling periods can be best adjusted for any linear transducer array. We experimentally implemented scanning with a 5-MHz array. In vitro characterization was performed with phantoms designed to test resolution and contrast. Spatial resolution assessed based on the full-width half-maximum of images from isolated microspheres was increased by a factor 3 along the translational direction from a simple translation scan of the array. Moreover, the resolution is uniform over a cross-sectional area of 4.5 cm 2. Angular sampling periods were optimized and tapered to decrease the scan duration while maintaining image contrast (contrast at the center of a 5 mm cyst on the order of-26 dB for 4{\textdegree} angular period and a scan duration of 10 s for a 9cm 3 volume). We demonstrate that superior 3-D US imaging can be obtained with a clinical array using our scanning strategy. This technique offers a promising and flexible alternative to development of costly matrix arrays toward the development of sensitive volumetric ultrasonography.

  • Open Access

    High-Contrast and -Resolution 3-D Ultrasonography with a Clinical Linear Transducer Array Scanned in a Rotate-Translate Geometry

    by Théotim Lucas, Isabelle Quidu, S. Lori Bridal, Jerome Gateau

    We proposed a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound platform. The rotate-translate scanning scheme increases the elevation angular aperture by pivoting the array (−45° to 45°) around its array axis (axis along the row of its elements) and then scans the imaged object for each pivoted angle by translating the array perpendicularly to the rotation axis. A theoretical basis is presented so that the angular and translational scan sampling periods can be best adjusted for any linear transducer array. We experimentally implemented scanning with a 5-MHz array. In vitro characterization was performed with phantoms designed to test resolution and contrast. Spatial resolution assessed based on the full-width half-maximum of images from isolated microspheres was increased by a factor of 3 along the translational direction from a simple translation scan of the array. Moreover, the resolution was uniform over a cross-sectional area of 4.5 cm2. Angular sampling periods were optimized and tapered to decrease the scan duration while maintaining image contrast (contrast at the center of a 5-mm cyst on the order of −26 dB for 4° angular period and a scan duration of 10 s for a 9-cm3 volume). We demonstrated that superior 3-D ultrasound imaging can be obtained with a clinical array using our scanning strategy. This technique offers a promising and flexible alternative to development of costly matrix arrays toward the development of sensitive volumetric ultrasonography.


  • Open Access

    Low Frequency SAS: Influence of multipaths on Spatial Coherence

    by Fabien Novella, Yan Pailhas, Gilles Le Chenadec, Isabelle Quidu, Michel Legris

    Multipath is an issue for the performance of synthetic aperture sonars. In HF-SAS (high frequency SAS) images, multipaths effects manifest in the hiding of targets, the loss of image contrast and the degradation of interferometry bathymetric estimates and degradation of spatial coherence due to a decrease of the SNR. In this study, the behaviour of a LF-SAS (low frequency SAS) equipped with a full 2D receiving array is analysed. This 2D Rx array enables the observation of the 2D spatial coherence. On the vertical axis, the existence of a multipath reflects on the emergence of lobes in the figure of coherence. Intuitively, the lobes can be understood considering that the direct path and a multipath can be seen from the reception array as two sources that act as a dipole antenna. This study aims at evaluating effects of multipaths on these lobes establishing the link between multipaths and lobes). The study builds upon data acquired by the HRLFSAS designed by NATO CMRE. The effect of multipath is highlighted thanks analytical modelisation and a comparison between observed coherence and the one predicted from application of the Van Cittert Zernike theorem to the distribution of energy estimated by a vertical beamforming.


  • Open Access

    Low Frequency SAS: Spatial Coherence Study

    by Fabien Novella, Yan Pailhas, Isabelle Quidu, Gilles Le Chenadec

    The notion spatial coherence is used by sonar systems such as Correlation Velocity Logs (CVL) and Synthetic Aperture Sonars (SAS). It exploits correlation between acoustic signals sensed in space and time to estimate for example platform displacement. The Van Cittert Zernike (VCZ) theorem, is a classical statistical optics theorem that predicts the spatial coherence of a pressure field backscattered by a random medium. However it appears that intrinsic characteristics of Low Frequency Synthetic Aperture Sonar (LFSAS) can breach VCZ asumptions. In this paper, the notion of spatial coherence applied to a Low Frequency SAS system (LFSAS) is investigated. In a first part, the notion of spatial coherence and the VCZ therorem is presented. Then the High Resolution LFSAS (HRLFSAS) developed by NATO CMRE and used in this work is introduced. In the same time, a simulation tool is presented. In this paper, typical coherence functions obtained on simulation are presented. That allows to point out the link between the shape of the coherence function and the length of the transmit antenna. These functions are compared to the coherence observed on LFSAS data. Differences are investigated in terms of signal to noise ratio.


  • Synthetic Aperture Sonar Track Registration With Motion Compensation for Coherent Change Detection

    by Vincent Myers, Isabelle Quidu, Benoit Zerr, Torstein Olsmo Sabo, Roy Edgar Hansen

    The capability to detect changes in an underwater scene has many applications, including environmental monitoring, surveillance of strategic maritime waterways, and naval mine countermeasures. This paper examines the automated detection of changes in repeat-pass synthetic aperture sonar (SAS) imagery by exploiting the loss of phase coherence caused by differences in the scene. A renavigation method based on track registration is developed for performing the coregistration of images. The method first determines the corrections to be applied to the repeat-pass navigation data by optimizing a linear track model using the estimated across-track pixel displacements. A second optimization is then performed using the along-track pixel displacements to determine a velocity correction for each ping location of the repeat-pass image to compensate for residual motion errors. The corrected navigation solution is then used to rebeamform the repeat-pass image onto the same focal points as the reference image. The method is demonstrated on a pair of repeat-pass SAS images acquired using the AquaPix INSAS2 sonar, where it is shown that it is not necessary to have access to raw element data to coregister images accurately enough for coherent change detection requirements. This technique is then applied to the second data set obtained using the HISAS 1030 sonar for the purpose of comparing both coherent and noncoherent (amplitude-only) approaches to change detection in scenes with low and high clutters. False alarms caused by the acoustic shadows of objects in high-clutter areas are mitigated using the single-pass interferometric coherence as a reference mask. The results show the successful use of the repeat-pass coherence to detect changes between SAS images with temporal baselines of several days on scenes consisting of mud, gravel, and sand, and demonstrate that a coherent approach is capable of detecting large-scale differences (caused by the introduction or removal of targets) as well as subtle scene changes that are not detectable using noncoherent methods.


  • Open Access

    Markov-based approaches for ternary change detection between two high resolution synthetic aperture sonar tracks

    by Florian Nicolas, Andreas Arnold-Bos, Isabelle Quidu, Benoit Zerr

    Change detection methods, consisting in detecting potential changes between two images, representing the same geographical area but acquired at different times, have been widely used in sonar imagery. Such methods are very useful to accurately monitor, potentially low, variations in complex environments. Coherent methods, relying on both amplitude and phase of the backscattered signal, are limited because of the signals correlation that plummets with both frequency and temporal baseline. In this paper, we propose an incoherent method, only using the amplitude images, to solve the change detection problem. This method relies on a robust mathematical expression for the class conditional probability density functions of the log-ratio image along with various Markov-based approaches to provide a ternary change map, thus allowing to better understand the changes that have occured on the seafloor.