Changbin Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Changbin Yu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Changbin Yu
College of Artificial Intelligence and Big Data Shandong First Medical University & Shandong Academy of Medical Sciences Jinan China
2 shared publications- Bo Wang
Department of Pathology The First Affiliated Hospital, Zhejiang University School of Medicine Hangzhou China
1 shared publication - Chen Chen
SCIEX
1 shared publication - Christie L. Hunter
SCIEX
1 shared publication Chun Cheng
School of Computer Science, Fudan University, Shanghai, China
1 shared publication- Chun Cheng1 shared publication
Latest Publications
- Open Access
- 9 March 2021
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 15 (8) , 1148-1156
Global asymptotic stability of a general biased min‐consensus protocol
In this paper, a general biased min‐consensus protocol for continuous‐time multi‐agent systems is presented. In this protocol, agents considered as sources maintain static states, while the state of each non‐source agent evolves using a general min‐consensus‐like function, which takes the states of its neighbours and a biased term as inputs. The properties of the general function have been identified so that the proposed protocol can achieve global asymptotic stability. Unlike conventional consensus protocols where a network of agents reach an agreement on certain quantities of interest, agents under the general biased min‐consensus protocol will converge to different states but can generate various design results pertaining to complex combinatorial optimization problems, such as the shortest path problem and its variants.
- 9 March 2021
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 15 (8) , 1148-1156
Open AccessGlobal asymptotic stability of a general biased min‐consensus protocol
In this paper, a general biased min‐consensus protocol for continuous‐time multi‐agent systems is presented. In this protocol, agents considered as sources maintain static states, while the state of each non‐source agent evolves using a general min‐consensus‐like function, which takes the states of its neighbours and a biased term as inputs. The properties of the general function have been identified so that the proposed protocol can achieve global asymptotic stability. Unlike conventional consensus protocols where a network of agents reach an agreement on certain quantities of interest, agents under the general biased min‐consensus protocol will converge to different states but can generate various design results pertaining to complex combinatorial optimization problems, such as the shortest path problem and its variants.
- 1 February 2021
- Published by Springer Nature in Science China Information Sciences
- Vol. 65 (2) , 1-3
Social conformity creates consensus and strong diversity of Hegselmann-Krause opinion dynamics
- 1 February 2021
- Published by Springer Nature in Science China Information Sciences
- Vol. 65 (2) , 1-3
Social conformity creates consensus and strong diversity of Hegselmann-Krause opinion dynamics
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 2483-2488
Consensus for Expressed and Private Opinions under Self-Persuasion
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 2483-2488
Consensus for Expressed and Private Opinions under Self-Persuasion
- Open Access
Accelerated Protein Biomarker Discovery from FFPE tissue samples using Single-shot, Short Gradient Microflow SWATH MS
We report and evaluated a microflow, single-shot, short gradient SWATH MS method intended to accelerate the discovery and verification of protein biomarkers in clinical specimens. The method uses 15-min gradient microflow-LC peptide separation, an optimized SWATH MS window configuration and OpenSWATH software for data analysis. We applied the method to a cohort 204 of FFPE prostate tissue samples from 58 prostate cancer patients and 10 prostatic hyperplasia patients. Altogether we identified 27,976 proteotypic peptides and 4,043 SwissProt proteins from these 204 samples. Compared to a reference SWATH method with 2-hour gradient the accelerated method consumed only 27% instrument time, quantified 80% proteins and showed reduced batch effects. 3,800 proteins were quantified by both methods in two different instruments with relatively high consistency (r = 0.77). 75 proteins detected by the accelerated method with differential abundance between clinical groups were selected for further validation. A shortlist of 134 selected peptide precursors from the 75 proteins were analyzed using MRM-HR, exhibiting high quantitative consistency with the 15-min SWATH method (r = 0.89) in the same sample set. We further verified the capacity of these 75 proteins in separating benign and malignant tissues (AUC = 0.99) in an independent prostate cancer cohort (n=154). Overall our data show that the single-shot short gradient microflow-LC SWATH MS method achieved about 4-fold acceleration of data acquisition with reduced batch effect and a moderate level of protein attrition compared to a standard SWATH acquisition method. Finally, the results showed comparable ability to separate clinical groups.
Open AccessAccelerated Protein Biomarker Discovery from FFPE tissue samples using Single-shot, Short Gradient Microflow SWATH MS
We report and evaluated a microflow, single-shot, short gradient SWATH MS method intended to accelerate the discovery and verification of protein biomarkers in clinical specimens. The method uses 15-min gradient microflow-LC peptide separation, an optimized SWATH MS window configuration and OpenSWATH software for data analysis. We applied the method to a cohort 204 of FFPE prostate tissue samples from 58 prostate cancer patients and 10 prostatic hyperplasia patients. Altogether we identified 27,976 proteotypic peptides and 4,043 SwissProt proteins from these 204 samples. Compared to a reference SWATH method with 2-hour gradient the accelerated method consumed only 27% instrument time, quantified 80% proteins and showed reduced batch effects. 3,800 proteins were quantified by both methods in two different instruments with relatively high consistency (r = 0.77). 75 proteins detected by the accelerated method with differential abundance between clinical groups were selected for further validation. A shortlist of 134 selected peptide precursors from the 75 proteins were analyzed using MRM-HR, exhibiting high quantitative consistency with the 15-min SWATH method (r = 0.89) in the same sample set. We further verified the capacity of these 75 proteins in separating benign and malignant tissues (AUC = 0.99) in an independent prostate cancer cohort (n=154). Overall our data show that the single-shot short gradient microflow-LC SWATH MS method achieved about 4-fold acceleration of data acquisition with reduced batch effect and a moderate level of protein attrition compared to a standard SWATH acquisition method. Finally, the results showed comparable ability to separate clinical groups.