Florian Meneau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Florian Meneau has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Amélie Rochet
Brazilian Synchrotron Light Laboratory (LNLS)
6 shared publications - Carla Cristina Polo
Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM), 13083-970, Campinas, SP, Brazil
6 shared publications Tiago A. Kalile
Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM)
4 shared publications- Aline Ribeiro Passos
Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas, Brazil
3 shared publications Ross Harder
Advanced Photon Source, Argonne National Laboratory, 9700 S. Cass Avenue, Lemont, Illinois, 60439-4801, UNITED STATES
3 shared publicationsAmélie Rochet
2 shared publications
Latest Publications
- Open Access
- 10 August 2026
- Published by American Chemical Society (ACS) in Photon Science
Geometric Correction Method for Large-Area Pixel-Detectors for Improved Resolution in X-ray Imaging
Large-area hybrid pixel detectors are widely used in synchrotron facilities in small-angle X-ray scattering and crystallography beamlines but also for imaging techniques, due to their high dynamic range and single-photon sensitivity. However, their modular construction introduces gaps that limit the effective use of detector pixels and degrade data quality and reconstruction fidelity for imaging techniques. Here we present a method for geometric calibration and correction framework for the PIMEGA 540D detector installed at the Cateretê beamline of Sirius. This detector consists of modular constructions with large active area (∼ 170 × 170 mm2), with 300 μm thick silicon sensors, and pixel sizes of 55 × 55 μm2. It has a tiled architecture with reduced gaps minimising data losses; however it introduces geometric complexities requiring accurate calibration. Existing calibration approaches typically assume planar detector geometry and rely on continuous transformations, which may introduce artifacts in the scattering signal. The presented method is based on the alignment of detector substructures through discrete rotations and integer in-plane translations within a common coordinate system, while explicitly accounting for gaps between elements, calibrated using the scattering of a grid pattern, without the need of a priori knowledge of the detector mounting. By applying these corrections, the full active detector area can be exploited in diffraction and scattering experiments. We demonstrate the impact of this approach using ptychographic measurements of a Siemens star test pattern and a nano porous glass sample, both achieving spatial resolution of 8 nm in two and three-dimensions, respectively. The results highlight the importance of accurate detector geometry for high-resolution imaging and provide a practical method for large-area detectors geometrical corrections, of broad interest to the photon science community.
- 10 August 2026
- Published by American Chemical Society (ACS) in Photon Science
Open AccessGeometric Correction Method for Large-Area Pixel-Detectors for Improved Resolution in X-ray Imaging
Large-area hybrid pixel detectors are widely used in synchrotron facilities in small-angle X-ray scattering and crystallography beamlines but also for imaging techniques, due to their high dynamic range and single-photon sensitivity. However, their modular construction introduces gaps that limit the effective use of detector pixels and degrade data quality and reconstruction fidelity for imaging techniques. Here we present a method for geometric calibration and correction framework for the PIMEGA 540D detector installed at the Cateretê beamline of Sirius. This detector consists of modular constructions with large active area (∼ 170 × 170 mm2), with 300 μm thick silicon sensors, and pixel sizes of 55 × 55 μm2. It has a tiled architecture with reduced gaps minimising data losses; however it introduces geometric complexities requiring accurate calibration. Existing calibration approaches typically assume planar detector geometry and rely on continuous transformations, which may introduce artifacts in the scattering signal. The presented method is based on the alignment of detector substructures through discrete rotations and integer in-plane translations within a common coordinate system, while explicitly accounting for gaps between elements, calibrated using the scattering of a grid pattern, without the need of a priori knowledge of the detector mounting. By applying these corrections, the full active detector area can be exploited in diffraction and scattering experiments. We demonstrate the impact of this approach using ptychographic measurements of a Siemens star test pattern and a nano porous glass sample, both achieving spatial resolution of 8 nm in two and three-dimensions, respectively. The results highlight the importance of accurate detector geometry for high-resolution imaging and provide a practical method for large-area detectors geometrical corrections, of broad interest to the photon science community.
- 1 July 2026
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 38 (13) , 6812-6821
Revealing Microscale Hydrogel 3D Structural Features at Ambient Conditions Using Ptychographic X-ray Computed Tomography
- 1 July 2026
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 38 (13) , 6812-6821
Revealing Microscale Hydrogel 3D Structural Features at Ambient Conditions Using Ptychographic X-ray Computed Tomography
- Open Access
- 18 March 2026
- Published by American Chemical Society (ACS) in JACS Au
- Vol. 6 (4) , 2489-2497
Framework Flexibility Governs Molecular Accessibility and Selectivity in Zeolite Catalysts
Crystalline microporous zeolites are pivotal materials in the petrochemical industry, catalysis, separation, and energy conversion. Their performance arises from ordered frameworks that govern molecular transport and reactivity, complemented by tunable acidity. Although traditionally regarded as rigid, zeolite frameworks display remarkable structural flexibility under working conditions, a feature often overlooked but crucial for understanding their catalytic activity. Here, we report the direct imaging of nanozeolite flexibility during ethanol conversion using in situ Bragg coherent diffractive imaging (BCDI). We directly visualize and quantitatively measure zeolite flexibility through its interconnected manifestations as lattice distortion and strain. Three-dimensional strain maps reveal dynamic, facet-specific distortions that correlate with the anisotropic channel orientations of the MFI framework, establishing a link among directional flexibility, molecular selectivity, and catalytic performance. Our measurements achieve picometer-level strain sensitivity and picojoule-scale deformation energy quantification, providing unprecedented insight into the energetics of zeolite framework elasticity. These findings challenge the rigid-host paradigm and establish flexibility as a major parameter for tuning molecular accessibility and selectivity. More broadly, they demonstrate how coherent X-ray imaging can capture real-time lattice dynamics in complex materials, paving the way for adaptive catalysts and advanced separation processes that harness the structural flexibility for enhanced performance.
- 18 March 2026
- Published by American Chemical Society (ACS) in JACS Au
- Vol. 6 (4) , 2489-2497
Open AccessFramework Flexibility Governs Molecular Accessibility and Selectivity in Zeolite Catalysts
Crystalline microporous zeolites are pivotal materials in the petrochemical industry, catalysis, separation, and energy conversion. Their performance arises from ordered frameworks that govern molecular transport and reactivity, complemented by tunable acidity. Although traditionally regarded as rigid, zeolite frameworks display remarkable structural flexibility under working conditions, a feature often overlooked but crucial for understanding their catalytic activity. Here, we report the direct imaging of nanozeolite flexibility during ethanol conversion using in situ Bragg coherent diffractive imaging (BCDI). We directly visualize and quantitatively measure zeolite flexibility through its interconnected manifestations as lattice distortion and strain. Three-dimensional strain maps reveal dynamic, facet-specific distortions that correlate with the anisotropic channel orientations of the MFI framework, establishing a link among directional flexibility, molecular selectivity, and catalytic performance. Our measurements achieve picometer-level strain sensitivity and picojoule-scale deformation energy quantification, providing unprecedented insight into the energetics of zeolite framework elasticity. These findings challenge the rigid-host paradigm and establish flexibility as a major parameter for tuning molecular accessibility and selectivity. More broadly, they demonstrate how coherent X-ray imaging can capture real-time lattice dynamics in complex materials, paving the way for adaptive catalysts and advanced separation processes that harness the structural flexibility for enhanced performance.
- Open Access
Three-dimensional nano-imaging reveals subtle changes in xylem structure in CAD-deficient sorghum
Lignin plays a central role in the formation and function of secondary cell walls in vascular plants. However, the structural consequences of lignin modification for cell wall properties and cellular function in grasses remain poorly understood. Here, we investigated how cinnamyl alcohol dehydrogenase (CAD) deficiency alters vascular cell architecture in Sorghum bicolor , using the brown midrib-6 ( bmr6 ) mutant as a model system. Biochemical and histochemical analyses confirmed altered lignin chemistry in bmr6 , including increased incorporation of hydroxycinnamaldehyde residues and reduced tricin levels. We applied ptychographic X-ray computed tomography (PXCT) to quantify the cell wall geometry, in three dimensions, at nanometer-scale resolution. PXCT enabled measurements of wall thickness distribution and lumen shape along tracheary elements. Analyses revealed no significant differences in wall thickness between wild-type and bmr6 plants. However, three-dimensional morphometric descriptors indicated reduced lumen convexity in bmr6 , suggesting localized modifications not detectable by conventional two-dimensional imaging. Water flow numerical simulations through PXCT-derived images indicated reduced vessel permeability and simulated hydraulic conductivity in bmr6 , suggesting that subtle geometric changes may influence performance. These findings highlight the value of three-dimensional imaging for resolving cell wall organization and provide new insight into the architectural resilience of grass xylem in response to targeted lignin modification. Highlight: Three-dimensional X-ray nano-imaging reveals alterations in the cell wall architecture that affect simulated hydraulic performance under reduced CAD activity in sorghum.
Open AccessThree-dimensional nano-imaging reveals subtle changes in xylem structure in CAD-deficient sorghum
Lignin plays a central role in the formation and function of secondary cell walls in vascular plants. However, the structural consequences of lignin modification for cell wall properties and cellular function in grasses remain poorly understood. Here, we investigated how cinnamyl alcohol dehydrogenase (CAD) deficiency alters vascular cell architecture in Sorghum bicolor , using the brown midrib-6 ( bmr6 ) mutant as a model system. Biochemical and histochemical analyses confirmed altered lignin chemistry in bmr6 , including increased incorporation of hydroxycinnamaldehyde residues and reduced tricin levels. We applied ptychographic X-ray computed tomography (PXCT) to quantify the cell wall geometry, in three dimensions, at nanometer-scale resolution. PXCT enabled measurements of wall thickness distribution and lumen shape along tracheary elements. Analyses revealed no significant differences in wall thickness between wild-type and bmr6 plants. However, three-dimensional morphometric descriptors indicated reduced lumen convexity in bmr6 , suggesting localized modifications not detectable by conventional two-dimensional imaging. Water flow numerical simulations through PXCT-derived images indicated reduced vessel permeability and simulated hydraulic conductivity in bmr6 , suggesting that subtle geometric changes may influence performance. These findings highlight the value of three-dimensional imaging for resolving cell wall organization and provide new insight into the architectural resilience of grass xylem in response to targeted lignin modification. Highlight: Three-dimensional X-ray nano-imaging reveals alterations in the cell wall architecture that affect simulated hydraulic performance under reduced CAD activity in sorghum.
- Open Access
Correlative Synchrotron X-ray Microscopy Reveals Dose- and Division-Dependent Nanoparticle Redistribution in Macrophages
Understanding the intracellular fate of nanoparticles is essential for designing safer and more effective nanomedicines, yet most studies rely on static observations and lack high-resolution, near-native volumetric information. Here, we establish a synchrotron-based correlative X-ray microscopy framework to investigate how fluorescent silica nanoparticles (SiNPs) redistribute within macrophages as a function of concentration and successive cell-division cycles. SiNPs were internalized by RAW 264.7 macrophages at different concentrations and analyzed using a synchrotron-based correlative X-ray microscopy workflow integrating cryogenic soft X-ray tomography (cryo-SXT), cryogenic structured illumination microscopy (cryo-SIM), and coherent X-ray ptychography, with confocal fluorescence microscopy used to establish population-level uptake tendencies. Cryo-SXT reveals a concentration-dependent redistribution of nanoparticle-containing vesicles from peripheral endosomes toward the perinuclear region, while correlative cryo-SIM confirms strict vesicular confinement, with no evidence of free nanoparticle diffusion into the nucleoplasm. At higher doses, nanoparticles approach the nuclear region via vesicles extending into nuclear-envelope invaginations, rather than by true nuclear entry. Successive cell divisions redistribute the intracellular nanoparticle load and promote stable perinuclear clustering, identifying a long-term sequestration route in macrophages. Coherent X-ray ptychography further reveals nanoscale deformations of the nuclear envelope associated with dense perinuclear vesicles. Together, these results establish synchrotron-based correlative X-ray microscopy as a mechanistic, multiscale platform for unveiling the dynamic intracellular fate of nanoparticles and providing mechanistic insight into their apparent nuclear localization.
Open AccessCorrelative Synchrotron X-ray Microscopy Reveals Dose- and Division-Dependent Nanoparticle Redistribution in Macrophages
Understanding the intracellular fate of nanoparticles is essential for designing safer and more effective nanomedicines, yet most studies rely on static observations and lack high-resolution, near-native volumetric information. Here, we establish a synchrotron-based correlative X-ray microscopy framework to investigate how fluorescent silica nanoparticles (SiNPs) redistribute within macrophages as a function of concentration and successive cell-division cycles. SiNPs were internalized by RAW 264.7 macrophages at different concentrations and analyzed using a synchrotron-based correlative X-ray microscopy workflow integrating cryogenic soft X-ray tomography (cryo-SXT), cryogenic structured illumination microscopy (cryo-SIM), and coherent X-ray ptychography, with confocal fluorescence microscopy used to establish population-level uptake tendencies. Cryo-SXT reveals a concentration-dependent redistribution of nanoparticle-containing vesicles from peripheral endosomes toward the perinuclear region, while correlative cryo-SIM confirms strict vesicular confinement, with no evidence of free nanoparticle diffusion into the nucleoplasm. At higher doses, nanoparticles approach the nuclear region via vesicles extending into nuclear-envelope invaginations, rather than by true nuclear entry. Successive cell divisions redistribute the intracellular nanoparticle load and promote stable perinuclear clustering, identifying a long-term sequestration route in macrophages. Coherent X-ray ptychography further reveals nanoscale deformations of the nuclear envelope associated with dense perinuclear vesicles. Together, these results establish synchrotron-based correlative X-ray microscopy as a mechanistic, multiscale platform for unveiling the dynamic intracellular fate of nanoparticles and providing mechanistic insight into their apparent nuclear localization.
- Open Access
- 30 January 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (5) , 3828-3838
In Situ Ptychographic X-ray Computed Tomography of Fully Hydrated Polyamide Membranes
Understanding the morphology of membranes under operational conditions is essential for advancing membrane material development for water purification and industrial applications. Traditional characterization methods, such as scanning and transmission electron microscopy, require vacuum environments and sample modifications that could alter membrane structures susceptible to hydration and swelling. Here, we present the first application of synchrotron-based ptychographic X-ray computed tomography (PXCT) for direct in situ nanoscale 3D imaging of hydrated thin-film composite polyamide membranes immersed in water. This method requires no staining, vitrification, or layer separation from the porous support by exposure to organic solvents. It preserves the polyamide membrane's native state. We studied lab-fabricated membranes containing 2-hydroxy-N-(diphenylmethyl) acetamide artificial water channels, revealing significant hydration-induced changes in structure, including up to 51% volume swelling, and increased surface roughness, attributed to the presence of artificial water channels in the polyamide matrix. Morphological features of the ridge-and-valley surface, such as bowl-shaped nodule structures, notably expanded in water. PXCT data were compared to atomic force microscopy measurements, highlighting both the capabilities and limitations of each technique. The in situ PXCT method demonstrated here offers invaluable insight into the hydrated polyamide membrane morphology. The demonstrated high-resolution PXCT method can be applied across disciplines in materials science and life sciences, enabling a detailed analysis of hydrated nanostructures under realistic conditions.
- 30 January 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (5) , 3828-3838
Open AccessIn Situ Ptychographic X-ray Computed Tomography of Fully Hydrated Polyamide Membranes
Understanding the morphology of membranes under operational conditions is essential for advancing membrane material development for water purification and industrial applications. Traditional characterization methods, such as scanning and transmission electron microscopy, require vacuum environments and sample modifications that could alter membrane structures susceptible to hydration and swelling. Here, we present the first application of synchrotron-based ptychographic X-ray computed tomography (PXCT) for direct in situ nanoscale 3D imaging of hydrated thin-film composite polyamide membranes immersed in water. This method requires no staining, vitrification, or layer separation from the porous support by exposure to organic solvents. It preserves the polyamide membrane's native state. We studied lab-fabricated membranes containing 2-hydroxy-N-(diphenylmethyl) acetamide artificial water channels, revealing significant hydration-induced changes in structure, including up to 51% volume swelling, and increased surface roughness, attributed to the presence of artificial water channels in the polyamide matrix. Morphological features of the ridge-and-valley surface, such as bowl-shaped nodule structures, notably expanded in water. PXCT data were compared to atomic force microscopy measurements, highlighting both the capabilities and limitations of each technique. The in situ PXCT method demonstrated here offers invaluable insight into the hydrated polyamide membrane morphology. The demonstrated high-resolution PXCT method can be applied across disciplines in materials science and life sciences, enabling a detailed analysis of hydrated nanostructures under realistic conditions.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-03 (1) , 151
Ptychographic Computed X-Ray Tomography of Ni-YSZ Anode Support
Solid oxide fuel cells (SOFCs) are efficient and flexible devices capable of operating with various fuels [1-3]. However, the complex microstructure and its intricate relation with the reactions taking place in SOFCs present significant challenges in terms of fabrication and understanding [4]. Key factors that need to be thoroughly understood for optimal device fabrication include the efficient electrode/electrolyte interface, the mechanical behavior of each component at operational temperatures, undesirable chemical interactions, and the detailed description of the dense/porous layered structures. To address these challenges, the use of advanced characterization tools ensures a more accurate understanding of the SOFC, thereby improving production processes and ultimately enhancing performance. Synchrotron X-ray techniques have been widely employed for characterizing various types of devices, demonstrating the capabilities of these light sources to interact with matter. Techniques based on diffraction or absorption phenomena can provide detailed information on the composition, structure, strain, and physical distribution of materials [5,6]. In this study, we used a 4th generation synchrotron light source to measure the distribution, interconnections, tortuosity, length, diameter, and density of pores in tape-cast Ni-YSZ anode support. A highly coherent X-ray beam was directed at a 60 µm high, 20 µm diameter pillar of the anode fabricated by focused ion beam (FIB) milling. The interaction (absorption and diffraction) between the X-ray beam and the sample allowed us to reconstruct a 3D image of the sample, revealing detailed information about the porous structure of the Ni-YSZ anode. Acknowledgments: CNPq, FAPESP, CNEN References [1] Singh, M., Zappa, D., & Comini, E. (2021). Solid oxide fuel cell: Decade of progress, future perspectives and challenges. International Journal of Hydrogen Energy , 46 (54), 27643-27674. [2] Kasaeian, A., Javidmehr, M., Mirzaie, M. R., & Fereidooni, L. (2023). Integration of solid oxide fuel cells with solar energy systems: A review. Applied Thermal Engineering , 224 , 120117. [3] Xu, Q., Guo, Z., Xia, L., He, Q., Li, Z., Bello, I. T., ... & Ni, M. (2022). A comprehensive review of solid oxide fuel cells operating on various promising alternative fuels. Energy Conversion and Management , 253 , 115175. [4] Mahmud, L. S., Muchtar, A., & Somalu, M. R. (2017). Challenges in fabricating planar solid oxide fuel cells: A review. Renewable and Sustainable Energy Reviews , 72 , 105-116. [5] Mino, L., Borfecchia, E., Segura-Ruiz, J., Giannini, C., Martinez-Criado, G., & Lamberti, C. (2018). Materials characterization by synchrotron x-ray microprobes and nanoprobes. Reviews of Modern Physics , 90 (2), 025007.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-03 (1) , 151
Ptychographic Computed X-Ray Tomography of Ni-YSZ Anode Support
Solid oxide fuel cells (SOFCs) are efficient and flexible devices capable of operating with various fuels [1-3]. However, the complex microstructure and its intricate relation with the reactions taking place in SOFCs present significant challenges in terms of fabrication and understanding [4]. Key factors that need to be thoroughly understood for optimal device fabrication include the efficient electrode/electrolyte interface, the mechanical behavior of each component at operational temperatures, undesirable chemical interactions, and the detailed description of the dense/porous layered structures. To address these challenges, the use of advanced characterization tools ensures a more accurate understanding of the SOFC, thereby improving production processes and ultimately enhancing performance. Synchrotron X-ray techniques have been widely employed for characterizing various types of devices, demonstrating the capabilities of these light sources to interact with matter. Techniques based on diffraction or absorption phenomena can provide detailed information on the composition, structure, strain, and physical distribution of materials [5,6]. In this study, we used a 4th generation synchrotron light source to measure the distribution, interconnections, tortuosity, length, diameter, and density of pores in tape-cast Ni-YSZ anode support. A highly coherent X-ray beam was directed at a 60 µm high, 20 µm diameter pillar of the anode fabricated by focused ion beam (FIB) milling. The interaction (absorption and diffraction) between the X-ray beam and the sample allowed us to reconstruct a 3D image of the sample, revealing detailed information about the porous structure of the Ni-YSZ anode. Acknowledgments: CNPq, FAPESP, CNEN References [1] Singh, M., Zappa, D., & Comini, E. (2021). Solid oxide fuel cell: Decade of progress, future perspectives and challenges. International Journal of Hydrogen Energy , 46 (54), 27643-27674. [2] Kasaeian, A., Javidmehr, M., Mirzaie, M. R., & Fereidooni, L. (2023). Integration of solid oxide fuel cells with solar energy systems: A review. Applied Thermal Engineering , 224 , 120117. [3] Xu, Q., Guo, Z., Xia, L., He, Q., Li, Z., Bello, I. T., ... & Ni, M. (2022). A comprehensive review of solid oxide fuel cells operating on various promising alternative fuels. Energy Conversion and Management , 253 , 115175. [4] Mahmud, L. S., Muchtar, A., & Somalu, M. R. (2017). Challenges in fabricating planar solid oxide fuel cells: A review. Renewable and Sustainable Energy Reviews , 72 , 105-116. [5] Mino, L., Borfecchia, E., Segura-Ruiz, J., Giannini, C., Martinez-Criado, G., & Lamberti, C. (2018). Materials characterization by synchrotron x-ray microprobes and nanoprobes. Reviews of Modern Physics , 90 (2), 025007.
- 21 November 2025
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 401
Three-dimensional visualisation of hierarchical zeolitic materials with ptychographic X-ray computed tomography
- 21 November 2025
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 401
Three-dimensional visualisation of hierarchical zeolitic materials with ptychographic X-ray computed tomography
- 6 November 2024
- Published by Elsevier in Catalysis Today
- Vol. 446
In situ visualisation of zeolite anisotropic framework flexibility during catalysis
- 6 November 2024
- Published by Elsevier in Catalysis Today
- Vol. 446
In situ visualisation of zeolite anisotropic framework flexibility during catalysis
- 22 August 2024
- Published by Elsevier in Catalysis Today
- Vol. 443
Monitoring the dynamics of nanozeolite formation by combined in situ coherent small angle X-ray scattering techniques
- 22 August 2024
- Published by Elsevier in Catalysis Today
- Vol. 443
Monitoring the dynamics of nanozeolite formation by combined in situ coherent small angle X-ray scattering techniques