Adam Borzsonyi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adam Borzsonyi has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Attila Pál Kovács
University of Szeged
1 shared publication - Karoly Osvay
National Laser-Initiated Transmutation Laboratory, University of Szeged, Szeged, Hungary
1 shared publication
Latest Publications
- 27 October 2014
- Published by University of Szeged
Optimization of process parameters of coated pellet production
- 27 October 2014
- Published by University of Szeged
Optimization of process parameters of coated pellet production
- Open Access
- 26 April 2013
- Published by MDPI AG in Applied Sciences
- Vol. 3 (2) , 515-544
What We Can Learn about Ultrashort Pulses by Linear Optical Methods
Spatiotemporal compression of ultrashort pulses is one of the key issues of chirped pulse amplification (CPA), the most common method to achieve high intensity laser beams. Successful shaping of the temporal envelope and recombination of the spectral components of the broadband pulses need careful alignment of the stretcher-compressor stages. Pulse parameters are required to be measured at the target as well. Several diagnostic techniques have been developed so far for the characterization of ultrashort pulses. Some of these methods utilize nonlinear optical processes, while others based on purely linear optics, in most cases, combined with spectrally resolving device. The goal of this work is to provide a review on the capabilities and limitations of the latter category of the ultrafast diagnostical methods. We feel that the importance of these powerful, easy-to-align, high-precision techniques needs to be emphasized, since their use could gradually improve the efficiency of different CPA systems. We give a general description on the background of spectrally resolved linear interferometry and demonstrate various schematic experimental layouts for the detection of material dispersion, angular dispersion and carrier-envelope phase drift. Precision estimations and discussion of potential applications are also provided.
- 26 April 2013
- Published by MDPI AG in Applied Sciences
- Vol. 3 (2) , 515-544
Open AccessWhat We Can Learn about Ultrashort Pulses by Linear Optical Methods
Spatiotemporal compression of ultrashort pulses is one of the key issues of chirped pulse amplification (CPA), the most common method to achieve high intensity laser beams. Successful shaping of the temporal envelope and recombination of the spectral components of the broadband pulses need careful alignment of the stretcher-compressor stages. Pulse parameters are required to be measured at the target as well. Several diagnostic techniques have been developed so far for the characterization of ultrashort pulses. Some of these methods utilize nonlinear optical processes, while others based on purely linear optics, in most cases, combined with spectrally resolving device. The goal of this work is to provide a review on the capabilities and limitations of the latter category of the ultrafast diagnostical methods. We feel that the importance of these powerful, easy-to-align, high-precision techniques needs to be emphasized, since their use could gradually improve the efficiency of different CPA systems. We give a general description on the background of spectrally resolved linear interferometry and demonstrate various schematic experimental layouts for the detection of material dispersion, angular dispersion and carrier-envelope phase drift. Precision estimations and discussion of potential applications are also provided.