Jung Ho Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jung Ho Lee has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Dong Jun Kim
Dept. of Civil Eng Dept. of Civil Eng Dept. of Civil and Environmental Eng Hanbat National University Hanbat National University Hanbat National University
11 shared publications - Yang Ho Song
Department of Civil and Environmental Engineering, Hanbat National University, Daejeon 34158, Korea
10 shared publications - Da Hae Yu
Department of Civil Engineering, Hanbat National University, 125, Dongseo-daero, Yuseong-gu, Daejeon 34049, Republic of Korea
7 shared publications Yang Ho Song
4 shared publicationsDong Jun Kim
3 shared publications- Eui Hoon Lee
School of Civil Engineering, Chungbuk National University, Cheongju 28644, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 451-460
Multi-Criteria Evaluation of Operation Priorities for Urban Drainage Pump Stations Using a Flood Damage Index
This study presents a simple framework for prioritizing the operation of multiple urban stormwater pump stations using the Flood Damage Index (FD) and Flood Damage Reduction Index (FDR). Two-dimensional inundation modelling was used to estimate FD for each basin, and FDR is derived from the difference between FD with and without pump operation. Linear performance curves are then developed for each pump, and all feasible pump combinations are generated under river-based allowable discharge scenarios (60-300 m3/min). Each combination was compared from four perspectives: maximum flood damage reduction, flood damage reduction efficiency per unit discharge, distributed reduction (equity among catchments), and minimum safety, defined by the lower bound of the 95% confidence interval. The case study shows that when the discharge capacity is sufficient, the maximum reduction and efficiency criteria provide strategies that most effectively reduce the total damage, whereas the distributed criterion improves equity at the cost of some total reduction. The minimum safety criterion incorporates regression uncertainty and yields more conservative operational plans for the same allowable discharge.
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 451-460
Open AccessMulti-Criteria Evaluation of Operation Priorities for Urban Drainage Pump Stations Using a Flood Damage Index
This study presents a simple framework for prioritizing the operation of multiple urban stormwater pump stations using the Flood Damage Index (FD) and Flood Damage Reduction Index (FDR). Two-dimensional inundation modelling was used to estimate FD for each basin, and FDR is derived from the difference between FD with and without pump operation. Linear performance curves are then developed for each pump, and all feasible pump combinations are generated under river-based allowable discharge scenarios (60-300 m3/min). Each combination was compared from four perspectives: maximum flood damage reduction, flood damage reduction efficiency per unit discharge, distributed reduction (equity among catchments), and minimum safety, defined by the lower bound of the 95% confidence interval. The case study shows that when the discharge capacity is sufficient, the maximum reduction and efficiency criteria provide strategies that most effectively reduce the total damage, whereas the distributed criterion improves equity at the cost of some total reduction. The minimum safety criterion incorporates regression uncertainty and yields more conservative operational plans for the same allowable discharge.
- Open Access
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 425-438
Analysis of the Characteristics of Urban Flood Inundation Modeling in GUDS (Grid-Based Urban Drainage System Analysis Model) Using Idealized Topography
Recent climate change and urbanization have increased localized heavy rainfall, leading to repeated urban inundation events and a growing need for two-dimensional inundation models that can quickly and accurately simulate various rainfall scenarios. This study compares the inundation behavior of a Grid-Based Urban Drainage System Analysis Model (GUDS), a grid-based urban drainage model which has a WCA2D-based surface module, with that of the shallow-water-equation-based commercial model XP-SWMM. Three idealized catchments—inclined, single-grid inclined, and funnel-type—were configured, and both models were run under identical inflow conditions. Model performance was evaluated using pointwise flow velocity and water depth, inundation propagation, and the occurrence of numerical instabilities. In the longitudinal single-grid case, the differences in maximum velocity and water depth were within approximately 10%, confirming that the GUDS can reproduce one-dimensional flow behavior. In the inclined and funnel-type cases, XP-SWMM produced locally faster and deeper flows, whereas GUDS yielded smoother fields. Differences in maximum water depth and inundation area were 13.3% and 14.6% in the inclined case and 9.8% and 6.7% in the funnel case, respectively. Additionally, the XP-SWMM showed numerical instabilities in steep-slope sections, while the GUDS remained stable. However, only idealized topographies and simple inflow conditions were considered, and future work should verify the reliability and generality of the GUDS for real urban catchments.
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 425-438
Open AccessAnalysis of the Characteristics of Urban Flood Inundation Modeling in GUDS (Grid-Based Urban Drainage System Analysis Model) Using Idealized Topography
Recent climate change and urbanization have increased localized heavy rainfall, leading to repeated urban inundation events and a growing need for two-dimensional inundation models that can quickly and accurately simulate various rainfall scenarios. This study compares the inundation behavior of a Grid-Based Urban Drainage System Analysis Model (GUDS), a grid-based urban drainage model which has a WCA2D-based surface module, with that of the shallow-water-equation-based commercial model XP-SWMM. Three idealized catchments—inclined, single-grid inclined, and funnel-type—were configured, and both models were run under identical inflow conditions. Model performance was evaluated using pointwise flow velocity and water depth, inundation propagation, and the occurrence of numerical instabilities. In the longitudinal single-grid case, the differences in maximum velocity and water depth were within approximately 10%, confirming that the GUDS can reproduce one-dimensional flow behavior. In the inclined and funnel-type cases, XP-SWMM produced locally faster and deeper flows, whereas GUDS yielded smoother fields. Differences in maximum water depth and inundation area were 13.3% and 14.6% in the inclined case and 9.8% and 6.7% in the funnel case, respectively. Additionally, the XP-SWMM showed numerical instabilities in steep-slope sections, while the GUDS remained stable. However, only idealized topographies and simple inflow conditions were considered, and future work should verify the reliability and generality of the GUDS for real urban catchments.
- Open Access
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 407-414
Implementation of a Prototype Genetic Algorithm for Optimal, Coordinated Operation of Stormwater Pump Stations
As heavy rainfall events increase, the need for efficient operation of urban drainage systems is becoming critical. In this study, we implement a prototype model designed to generate an optimal, coordinated operating schedule for an urban drainage system with the objective of minimizing system-wide flood damage. The proposed model rapidly estimates the total damage reduction by combining precomputed flood mitigation performance curves for each station with period-specific initial inundation indicators, and then selects the schedule that maximizes total damage reduction. The model is implemented as a Genetic Algorithm (GA) in a Python/DEAP environment and validated using a hypothetical pilot area. Validation using a hypothetical case confirmed that by rationally excluding inferior combinations of solutions, the optimization mechanism can be appropriately embedded in pump station operational decision-making, and its short execution time indicates the potential for deployment as a tool for real-time operation.
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 407-414
Open AccessImplementation of a Prototype Genetic Algorithm for Optimal, Coordinated Operation of Stormwater Pump Stations
As heavy rainfall events increase, the need for efficient operation of urban drainage systems is becoming critical. In this study, we implement a prototype model designed to generate an optimal, coordinated operating schedule for an urban drainage system with the objective of minimizing system-wide flood damage. The proposed model rapidly estimates the total damage reduction by combining precomputed flood mitigation performance curves for each station with period-specific initial inundation indicators, and then selects the schedule that maximizes total damage reduction. The model is implemented as a Genetic Algorithm (GA) in a Python/DEAP environment and validated using a hypothetical pilot area. Validation using a hypothetical case confirmed that by rationally excluding inferior combinations of solutions, the optimization mechanism can be appropriately embedded in pump station operational decision-making, and its short execution time indicates the potential for deployment as a tool for real-time operation.
- Open Access
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 391-398
Risk Assessment of Public Wastewater Treatment Facilities for Climate Crisis Adaptation: The Case of Sejong City
This study assessed the climate crisis risks of public wastewater treatment facilities in Sejong City, where structural and operational vulnerabilities are increasing owing to the accelerating impact of climate change. Nine public wastewater treatment facilities with a treatment capacity of more than 500 m3 per day were analyzed to evaluate the risks associated with 6 major climatic factors, namely heat wave, cold wave, heavy rainfall, snowfall, high wind, and drought across 3 key domains: facility, operator, and public services. The evaluation method involved calculating the “likelihood of occurrence” using extreme climate indices based on Representative Concentration Pathway scenarios, deriving the “magnitude of impact” for each sector through survey-based checklists, and then applying a process to calculate quantitative risk by integrating these two factors. Heat waves posed the greatest risk across all facilities, followed by droughts and heavy rainfall, whereas snowfall and high winds had relatively low impact. These findings indicate that the climatic vulnerability of Sejong City’s wastewater treatment facilities is primarily influenced by high temperatures and precipitation fluctuations. The primary reason for the highest risk associated with heat waves is that biological treatment processes, the core of wastewater treatment facilities, react sensitively to temperature changes, directly affecting treatment efficiency. Furthermore, it was found to have a significant impact on work environment safety, such as the risk of heat-related illnesses for facility managers with a high proportion of outdoor work. Consequently, establishing an operation and management system focused on heat-wave response is essential, along with addressing compound climatic factors, such as droughts and heavy rainfall, through proactive strategies. Furthermore, this study presented a quantitative risk assessment methodology for climate adaptation in public wastewater treatment facilities, which is expected to contribute to the development and implementation of climate-adaptive urban water management policies at the municipal level.
- 31 December 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (6) , 391-398
Open AccessRisk Assessment of Public Wastewater Treatment Facilities for Climate Crisis Adaptation: The Case of Sejong City
This study assessed the climate crisis risks of public wastewater treatment facilities in Sejong City, where structural and operational vulnerabilities are increasing owing to the accelerating impact of climate change. Nine public wastewater treatment facilities with a treatment capacity of more than 500 m3 per day were analyzed to evaluate the risks associated with 6 major climatic factors, namely heat wave, cold wave, heavy rainfall, snowfall, high wind, and drought across 3 key domains: facility, operator, and public services. The evaluation method involved calculating the “likelihood of occurrence” using extreme climate indices based on Representative Concentration Pathway scenarios, deriving the “magnitude of impact” for each sector through survey-based checklists, and then applying a process to calculate quantitative risk by integrating these two factors. Heat waves posed the greatest risk across all facilities, followed by droughts and heavy rainfall, whereas snowfall and high winds had relatively low impact. These findings indicate that the climatic vulnerability of Sejong City’s wastewater treatment facilities is primarily influenced by high temperatures and precipitation fluctuations. The primary reason for the highest risk associated with heat waves is that biological treatment processes, the core of wastewater treatment facilities, react sensitively to temperature changes, directly affecting treatment efficiency. Furthermore, it was found to have a significant impact on work environment safety, such as the risk of heat-related illnesses for facility managers with a high proportion of outdoor work. Consequently, establishing an operation and management system focused on heat-wave response is essential, along with addressing compound climatic factors, such as droughts and heavy rainfall, through proactive strategies. Furthermore, this study presented a quantitative risk assessment methodology for climate adaptation in public wastewater treatment facilities, which is expected to contribute to the development and implementation of climate-adaptive urban water management policies at the municipal level.
- Open Access
Study on Inundation Analysis Characteristics of a Grid-Based Urban Drainage System (GUDS)
The risk of urban flooding has escalated with increasing rainfall intensity and the expansion of impervious surfaces. While commercial models such as XP-SWMM provide reliable hydraulic analyses, their closed-source structure limits transparency and integration with external tools. In contrast, the Grid-Based Urban Drainage System Analysis Model (GUDS), developed on the Weighted Cellular Automata 2D (WCA2D) framework, offers greater flexibility for process verification and coupling with platforms such as GIS and spreadsheets. This study presents a comparative assessment of numerical stability and velocity estimation schemes between XP-SWMM and GUDS. Moving beyond previous validation-focused studies, it quantitatively examines how algorithmic formulations—particularly in flow velocity computation and numerical treatment—affect inundation propagation and model stability under varying topographic conditions. Results demonstrate that XP-SWMM yields higher analytical precision but is prone to numerical instability on steep slopes, whereas GUDS maintains stable simulations due to its simplified water-level-difference approach, albeit with reduced responsiveness to rapidly changing flows. The differences in maximum inundation depth, inundation area, and propagation speed were relatively minor—approximately 11.6%, 10.7%, and 9.2% on average, respectively. This work provides a novel quantitative perspective on the trade-offs between precision and stability in urban flood modeling, highlighting GUDS’s robustness and practical applicability as an open and extensible alternative to conventional equation-based models.
Open AccessStudy on Inundation Analysis Characteristics of a Grid-Based Urban Drainage System (GUDS)
The risk of urban flooding has escalated with increasing rainfall intensity and the expansion of impervious surfaces. While commercial models such as XP-SWMM provide reliable hydraulic analyses, their closed-source structure limits transparency and integration with external tools. In contrast, the Grid-Based Urban Drainage System Analysis Model (GUDS), developed on the Weighted Cellular Automata 2D (WCA2D) framework, offers greater flexibility for process verification and coupling with platforms such as GIS and spreadsheets. This study presents a comparative assessment of numerical stability and velocity estimation schemes between XP-SWMM and GUDS. Moving beyond previous validation-focused studies, it quantitatively examines how algorithmic formulations—particularly in flow velocity computation and numerical treatment—affect inundation propagation and model stability under varying topographic conditions. Results demonstrate that XP-SWMM yields higher analytical precision but is prone to numerical instability on steep slopes, whereas GUDS maintains stable simulations due to its simplified water-level-difference approach, albeit with reduced responsiveness to rapidly changing flows. The differences in maximum inundation depth, inundation area, and propagation speed were relatively minor—approximately 11.6%, 10.7%, and 9.2% on average, respectively. This work provides a novel quantitative perspective on the trade-offs between precision and stability in urban flood modeling, highlighting GUDS’s robustness and practical applicability as an open and extensible alternative to conventional equation-based models.
- Open Access
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 191-198
Development of Quantitative Evaluation Method for Flood Reduction Performance of Drainage Pump Station
As the frequency and intensity of extreme rainfall events increase due to climate change, the efficient placement and operation of urban drainage facilities have become increasingly important to minimize flood damage. To achieve this, it is critical to quantitatively evaluate the extent to which drainage facilities contribute to flood reduction. In this study, a new methodology was proposed to quantify the flood reduction performance of drainage facilities using performance curves. The performance curves were defined based on the flood reduction capacity within a catchment area under various rainfall scenarios, considering the different operational states of the drainage facilities. However, actual flood damage can be assessed based on the extent of stormwater overflow from manholes, considering the flood area and flood depth in the urban environment. Therefore, the flood volume prior to facility operation was converted into a flood damage index, and the reduced flood volume owing to facility operation was converted into a flood damage reduction index, with weighting applied according to flood area and flood depth. The resulting performance curve expresses the relationship between the flood damage index and flood damage reduction index. To validate the proposed quantitative evaluation method using the performance curves, a case study was conducted using a drainage pump station catchment equipped with four pumps. By applying various rainfall scenarios, four regression curves were derived based on the number of operating pumps, and all regression models were found to fit a statistically significant linear form. The coefficient of determination (R2) improved with the number of pumps, from 0.6567 for a single pump to 0.8689 for four pumps. Additionally, as the performance curves were based on a wide range of rainfall scenarios, the fitted points around each regression curve were dispersed. To account for this, 95% confidence intervals were calculated for each regression curve, providing a more concrete estimate of the range of flood reduction capacity achievable under various actual rainfall events. This approach is expected to support the practical evaluation and planning of drainage facility operations under extreme weather conditions in the future.
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 191-198
Open AccessDevelopment of Quantitative Evaluation Method for Flood Reduction Performance of Drainage Pump Station
As the frequency and intensity of extreme rainfall events increase due to climate change, the efficient placement and operation of urban drainage facilities have become increasingly important to minimize flood damage. To achieve this, it is critical to quantitatively evaluate the extent to which drainage facilities contribute to flood reduction. In this study, a new methodology was proposed to quantify the flood reduction performance of drainage facilities using performance curves. The performance curves were defined based on the flood reduction capacity within a catchment area under various rainfall scenarios, considering the different operational states of the drainage facilities. However, actual flood damage can be assessed based on the extent of stormwater overflow from manholes, considering the flood area and flood depth in the urban environment. Therefore, the flood volume prior to facility operation was converted into a flood damage index, and the reduced flood volume owing to facility operation was converted into a flood damage reduction index, with weighting applied according to flood area and flood depth. The resulting performance curve expresses the relationship between the flood damage index and flood damage reduction index. To validate the proposed quantitative evaluation method using the performance curves, a case study was conducted using a drainage pump station catchment equipped with four pumps. By applying various rainfall scenarios, four regression curves were derived based on the number of operating pumps, and all regression models were found to fit a statistically significant linear form. The coefficient of determination (R2) improved with the number of pumps, from 0.6567 for a single pump to 0.8689 for four pumps. Additionally, as the performance curves were based on a wide range of rainfall scenarios, the fitted points around each regression curve were dispersed. To account for this, 95% confidence intervals were calculated for each regression curve, providing a more concrete estimate of the range of flood reduction capacity achievable under various actual rainfall events. This approach is expected to support the practical evaluation and planning of drainage facility operations under extreme weather conditions in the future.
- Open Access
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 143-151
Applicability Assessment of a Grid-Based Urban Drainage System Analysis Model
With climate change accelerating, the importance of responding to urban inundation has increased, thereby increasing the demand for reliable two-dimensional flood analysis. However, commonly used commercial models are constrained by closed-source architectures, limiting the flexibility of model application and result interpretation. This study examined the applicability of a grid-based open-source Urban Drainage System (GUDS) model by comparing it with the commercial XP-SWMM model. The GUDS consists of modules for surface runoff, conduit flow, and inundation analysis, incorporating the NRCS-CN method, Clark unit hydrograph, EPA-SWMM, and the Weighted Cellular Automata 2D (WCA 2D) technique. As flow velocity critically influences flood propagation patterns, this study focused on comparing the velocity distribution characteristics. While WCA 2D selects the minimum of Manning’s and critical velocities, XP-SWMM calculates velocity using the momentum conservation equation. These differences were evaluated using simulations on simplified funnel-shaped and uniformly sloped terrains. The GUDS showed a linear increase in velocity with slope, whereas the XP-SWMM displayed a trapezoidal distribution. Despite these differences in the modeling approaches, the maximum water depth and inundation area showed less than 10% difference, indicating that the GUDS model is applicable for urban flood analysis.
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 143-151
Open AccessApplicability Assessment of a Grid-Based Urban Drainage System Analysis Model
With climate change accelerating, the importance of responding to urban inundation has increased, thereby increasing the demand for reliable two-dimensional flood analysis. However, commonly used commercial models are constrained by closed-source architectures, limiting the flexibility of model application and result interpretation. This study examined the applicability of a grid-based open-source Urban Drainage System (GUDS) model by comparing it with the commercial XP-SWMM model. The GUDS consists of modules for surface runoff, conduit flow, and inundation analysis, incorporating the NRCS-CN method, Clark unit hydrograph, EPA-SWMM, and the Weighted Cellular Automata 2D (WCA 2D) technique. As flow velocity critically influences flood propagation patterns, this study focused on comparing the velocity distribution characteristics. While WCA 2D selects the minimum of Manning’s and critical velocities, XP-SWMM calculates velocity using the momentum conservation equation. These differences were evaluated using simulations on simplified funnel-shaped and uniformly sloped terrains. The GUDS showed a linear increase in velocity with slope, whereas the XP-SWMM displayed a trapezoidal distribution. Despite these differences in the modeling approaches, the maximum water depth and inundation area showed less than 10% difference, indicating that the GUDS model is applicable for urban flood analysis.
- Open Access
- 31 December 2024
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 24 (6) , 349-356
Study of a Grid-Based Urban Drainage System Analysis Model
As the focus shifts from responding to climate change to adapting to the climate crisis, the need for detailed water adaptation strategies is increasing. Local governments are required to implement measures to address urban flooding, and models such as XP-SWMM are being utilized. However, these models have limitations in terms of precision owing to the resolution of the available data. To address this issue, this study developed a grid-based urban flood analysis model capable of predicting urban flooding using high-resolution data based on a detailed grid of less than 10 m, adequately considering watershed characteristics. It integrates surface runoff analysis using the Clark Unit Hydrograph method and the D8 algorithm, conduit transport analysis linked with EPA-SWMM, and flood analysis modules utilizing the WCA2D method. Unlike existing urban flood analysis models, which require complex parameters and specialized expertise, this model minimizes the number of input parameters to enhance accessibility for practitioners while maintaining reliability in the analysis results. A grid-based model based on high-resolution spatial data can be employed by local governments to establish practical guidelines. It effectively identifies vulnerable flood areas within cities and supports the development of specific flood response strategies, thereby contributing significantly to urban flood management and resilience planning.
- 31 December 2024
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 24 (6) , 349-356
Open AccessStudy of a Grid-Based Urban Drainage System Analysis Model
As the focus shifts from responding to climate change to adapting to the climate crisis, the need for detailed water adaptation strategies is increasing. Local governments are required to implement measures to address urban flooding, and models such as XP-SWMM are being utilized. However, these models have limitations in terms of precision owing to the resolution of the available data. To address this issue, this study developed a grid-based urban flood analysis model capable of predicting urban flooding using high-resolution data based on a detailed grid of less than 10 m, adequately considering watershed characteristics. It integrates surface runoff analysis using the Clark Unit Hydrograph method and the D8 algorithm, conduit transport analysis linked with EPA-SWMM, and flood analysis modules utilizing the WCA2D method. Unlike existing urban flood analysis models, which require complex parameters and specialized expertise, this model minimizes the number of input parameters to enhance accessibility for practitioners while maintaining reliability in the analysis results. A grid-based model based on high-resolution spatial data can be employed by local governments to establish practical guidelines. It effectively identifies vulnerable flood areas within cities and supports the development of specific flood response strategies, thereby contributing significantly to urban flood management and resilience planning.
- Open Access
- 31 December 2024
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 24 (6) , 81-86
An Analysis of Rainfall-Derived Infiltration and Inflow Using Water Level-to-Flow Conversion
During rainfall, the rise in groundwater levels, coupled with defects in pipe connections and manhole joints, increases Rainfall-Derived Infiltration and Inflow (RDII) in separate sewer systems. This results in exceedances of planned wastewater volumes and a surge in Separate Sewer Overflows (SSOs). To implement effective measures in the sewer system, it is crucial to monitor the long-term sewage flow under both dry and wet weather conditions to identify RDII sources within the sub-basins. However, because of the cost disparity between installing flow meters and water-level sensors, many municipalities opt for the latter, which is more economical but limits the accuracy of flow measurement. Therefore, this study developed a methodology to estimate flow rates based on measured water-level data, which were validated using adjacent flow measurement data. This water level-to-flow conversion method is expected to be utilized through the installation of water-level sensors owing to their ease of deployment, in addition to budgetary constraints that limit the use of flow meters. This approach enables the application of water-level data for flow estimation.
- 31 December 2024
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 24 (6) , 81-86
Open AccessAn Analysis of Rainfall-Derived Infiltration and Inflow Using Water Level-to-Flow Conversion
During rainfall, the rise in groundwater levels, coupled with defects in pipe connections and manhole joints, increases Rainfall-Derived Infiltration and Inflow (RDII) in separate sewer systems. This results in exceedances of planned wastewater volumes and a surge in Separate Sewer Overflows (SSOs). To implement effective measures in the sewer system, it is crucial to monitor the long-term sewage flow under both dry and wet weather conditions to identify RDII sources within the sub-basins. However, because of the cost disparity between installing flow meters and water-level sensors, many municipalities opt for the latter, which is more economical but limits the accuracy of flow measurement. Therefore, this study developed a methodology to estimate flow rates based on measured water-level data, which were validated using adjacent flow measurement data. This water level-to-flow conversion method is expected to be utilized through the installation of water-level sensors owing to their ease of deployment, in addition to budgetary constraints that limit the use of flow meters. This approach enables the application of water-level data for flow estimation.
- Open Access
- 31 December 2023
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 23 (6) , 307-315
Development of an Optimal RTK Calculation Program Using Genetic Algorithm
Rising levels of underground water and inappropriate pipe alignment during rainy weather have led to a rise in rainfall-derived infiltration and inflow (RDII), increasing incidences of separate sewer overflows (SSOs) and reducing the efficiency of sewage treatment systems. RTK analysis based on measured RDII data of the target area through computer modeling is essential when maintaining sewer pipes in order to address this RDII problem. In the Sanitary Sewer Overflow Analysis and Planning (SSOAP) program used for RTK analysis, calculating RTK using a trial and error method is a bit challenging. Accordingly, this study introduces a program to calculate the optimal RTK at the measurement point using a genetic algorithm. In ROP, accuracy was added to the RDII prediction mechanism by incorporating error rates based on time intervals into the evaluation factors of SSOAP, namely rainfall inflow rate and peak flow error rate. The error rate for the SSOAP program and ROP was validated as 2.66%.
- 31 December 2023
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 23 (6) , 307-315
Open AccessDevelopment of an Optimal RTK Calculation Program Using Genetic Algorithm
Rising levels of underground water and inappropriate pipe alignment during rainy weather have led to a rise in rainfall-derived infiltration and inflow (RDII), increasing incidences of separate sewer overflows (SSOs) and reducing the efficiency of sewage treatment systems. RTK analysis based on measured RDII data of the target area through computer modeling is essential when maintaining sewer pipes in order to address this RDII problem. In the Sanitary Sewer Overflow Analysis and Planning (SSOAP) program used for RTK analysis, calculating RTK using a trial and error method is a bit challenging. Accordingly, this study introduces a program to calculate the optimal RTK at the measurement point using a genetic algorithm. In ROP, accuracy was added to the RDII prediction mechanism by incorporating error rates based on time intervals into the evaluation factors of SSOAP, namely rainfall inflow rate and peak flow error rate. The error rate for the SSOAP program and ROP was validated as 2.66%.