Xianzhong Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xianzhong Duan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Yinhong Li
Huazhong University of Science and Technology
5 shared publications - Jinfu Chen
Huazhong University of Science and Technology
4 shared publications - Dongyuan Shi
Huazhong University of Science and Technology
3 shared publications - Lin Zhu
Electric Power Research Institute, Knoxville, TN, USA
3 shared publications - Qiaomu Zhu
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, 12443 Wuhan, Hubei China
3 shared publications - Yilu Liu
Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, TN, USA
3 shared publications
Latest Publications
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (3) , 2495
Erratum to “Theoretical Parameter Design Method of SFCL for Concurrent Commutation Failure Inhibition in SFCL-Segmented Multi-Infeed LCC-HVDC Systems” [May 20 1741-1757]
In the paper [1] below published in IEEE Trans. Power Syst., vol. 35, no. 3, pp. 1741–1757, May 2020.
- 18 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (3) , 2495
Erratum to “Theoretical Parameter Design Method of SFCL for Concurrent Commutation Failure Inhibition in SFCL-Segmented Multi-Infeed LCC-HVDC Systems” [May 20 1741-1757]
In the paper [1] below published in IEEE Trans. Power Syst., vol. 35, no. 3, pp. 1741–1757, May 2020.
- 19 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2380-2393
Incorporating Complex Inter-Inverter Interactions Into Strength Assessment for Emerging Hierarchical-Infeed LCC-UHVDC Systems
The strength concept is an important tool for voltage stability evaluation of emerging hierarchical-infeed LCC-UHVDC (HIDC) systems. However, the complex inter-inverter interactions in such systems have caused significant difficulties for the strength assessment. This makes the accuracy of earlier strength assessment indices limited due to empirical analysis rather than rigorous theoretical reasoning. Thus in this paper, the hierarchical-infeed voltage interaction factor (HVIF) index is firstly utilized to quantitatively depict the complex inter-inverter interactions in HIDC systems. The use of the HVIF enables these interactions to be effectively incorporated into the subsequent strength assessment by proposing the hierarchical-infeed interactive effective short-circuit ratio (HIESCR) strength index. The critical HIESCR (CHIESCR) defined to delineate the voltage stability limit also evaluates to consistently 1.0 such that the distance between the HIESCR and CHIESCR is naturally an accurate stability margin. Since the HIESCR is developed based on the rigorous theoretical reasoning, it is more accurate than earlier indices for voltage stability evaluation. Moreover, the parametric dependence analysis of the HIESCR versus various system parameters and rated operation variables is conducted. This offers a comprehensive perspective for better understanding of the strength variation characteristics. Finally, case study in the modified IEEE 118-bus system validates the HIESCR.
- 19 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2380-2393
Incorporating Complex Inter-Inverter Interactions Into Strength Assessment for Emerging Hierarchical-Infeed LCC-UHVDC Systems
The strength concept is an important tool for voltage stability evaluation of emerging hierarchical-infeed LCC-UHVDC (HIDC) systems. However, the complex inter-inverter interactions in such systems have caused significant difficulties for the strength assessment. This makes the accuracy of earlier strength assessment indices limited due to empirical analysis rather than rigorous theoretical reasoning. Thus in this paper, the hierarchical-infeed voltage interaction factor (HVIF) index is firstly utilized to quantitatively depict the complex inter-inverter interactions in HIDC systems. The use of the HVIF enables these interactions to be effectively incorporated into the subsequent strength assessment by proposing the hierarchical-infeed interactive effective short-circuit ratio (HIESCR) strength index. The critical HIESCR (CHIESCR) defined to delineate the voltage stability limit also evaluates to consistently 1.0 such that the distance between the HIESCR and CHIESCR is naturally an accurate stability margin. Since the HIESCR is developed based on the rigorous theoretical reasoning, it is more accurate than earlier indices for voltage stability evaluation. Moreover, the parametric dependence analysis of the HIESCR versus various system parameters and rated operation variables is conducted. This offers a comprehensive perspective for better understanding of the strength variation characteristics. Finally, case study in the modified IEEE 118-bus system validates the HIESCR.
- 28 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 943-956
High Fault-Resistance Tolerable Traveling Wave Protection for Multi-Terminal VSC-HVDC
To deal with the high-resistance fault identification problem in multi-terminal VSC-HVDC, this paper proposes a high fault-resistance tolerable traveling wave protection. First, the non-unified characteristic of traveling wave front between internal and external faults is revealed, which makes the high-resistance fault identification difficult. Then, the traveling wave propagation regarding the reflection and refraction process at the remote end is investigated for the difference, and the distinctive current reduction phenomenon during the interval of two incident traveling waves under internal fault with resistance is discovered. Moreover, the current reduction phenomenon would become more significant with the increase of fault resistance. Based on this phenomenon, the high fault-resistance tolerable traveling wave protection is proposed, which could identify the high-resistance fault accurately with single-end measurement and is insensitive to fault resistance. The feasibility and robustness of the proposed protection are validated in a four-terminal VSC-HVDC.
- 28 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 943-956
High Fault-Resistance Tolerable Traveling Wave Protection for Multi-Terminal VSC-HVDC
To deal with the high-resistance fault identification problem in multi-terminal VSC-HVDC, this paper proposes a high fault-resistance tolerable traveling wave protection. First, the non-unified characteristic of traveling wave front between internal and external faults is revealed, which makes the high-resistance fault identification difficult. Then, the traveling wave propagation regarding the reflection and refraction process at the remote end is investigated for the difference, and the distinctive current reduction phenomenon during the interval of two incident traveling waves under internal fault with resistance is discovered. Moreover, the current reduction phenomenon would become more significant with the increase of fault resistance. Based on this phenomenon, the high fault-resistance tolerable traveling wave protection is proposed, which could identify the high-resistance fault accurately with single-end measurement and is insensitive to fault resistance. The feasibility and robustness of the proposed protection are validated in a four-terminal VSC-HVDC.
- 10 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1761-1772
Learning Heterogeneous Features Jointly: A Deep End-to-End Framework for Multi-Step Short-Term Wind Power Prediction
Leveraging multiple heterogeneous measurements to predict wind power has long been a challenging task in the electrical community. In this paper, a deep architecture incorporated with multitask learning and multimodal learning for wind power prediction, termed predictive stacked autoencoder (PSAE), is presented. PSAE is a unified framework integrating multiple stacked autoencoders (SAEs), one feature fusion layer, and one prediction terminal layer, which expands the architecture from two spatial dimensions, including the depth and width, compared to conventional prediction models. Initially, the SAEs at the bottom of PSAE extracted features from multiple kinds of measurements respectively. Following, the feature fusion layer encodes the high-order features extracted by different SAEs into a unified feature that is more informative and representative for wind power prediction. Finally, the prediction terminal layer functions as a regression machine which generates the predicted targets based on the fusion features. Trained in an end-to-end (E2E) manner, PSAE is capable of learning heterogeneous features jointly and achieving the prediction task of sequence-to-sequence (S2S). Experiments for multi-step short-term predictions are conducted on real-world data, and the results demonstrate the superiority of PSAE to prior methods.
- 10 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1761-1772
Learning Heterogeneous Features Jointly: A Deep End-to-End Framework for Multi-Step Short-Term Wind Power Prediction
Leveraging multiple heterogeneous measurements to predict wind power has long been a challenging task in the electrical community. In this paper, a deep architecture incorporated with multitask learning and multimodal learning for wind power prediction, termed predictive stacked autoencoder (PSAE), is presented. PSAE is a unified framework integrating multiple stacked autoencoders (SAEs), one feature fusion layer, and one prediction terminal layer, which expands the architecture from two spatial dimensions, including the depth and width, compared to conventional prediction models. Initially, the SAEs at the bottom of PSAE extracted features from multiple kinds of measurements respectively. Following, the feature fusion layer encodes the high-order features extracted by different SAEs into a unified feature that is more informative and representative for wind power prediction. Finally, the prediction terminal layer functions as a regression machine which generates the predicted targets based on the fusion features. Trained in an end-to-end (E2E) manner, PSAE is capable of learning heterogeneous features jointly and achieving the prediction task of sequence-to-sequence (S2S). Experiments for multi-step short-term predictions are conducted on real-world data, and the results demonstrate the superiority of PSAE to prior methods.
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (1) , 509-523
Learning Temporal and Spatial Correlations Jointly: A Unified Framework for Wind Speed Prediction
Leveraging both temporal and spatial correlations to predict wind speed remains one of the most challenging and less studied areas of wind speed prediction. In this paper, the problem of predicting wind speeds for multiple sites is investigated by using the spatio-temporal correlation. We proposed a deep architecture termed predictive spatio-temporal network (PSTN), which is a unified framework integrating a convolutional neural network (CNN) and a long short-term memory (LSTM). Initially, the spatial features are extracted from the spatial wind speed matrices (SWSMs) by the CNN at the bottom of the model. Then, the LSTM captures the temporal dependencies among the spatial features extracted from contiguous time points. Finally, the predicted wind speeds are given by the last state of the top layer of the LSTM, which are generated by using the spatial features and temporal dependencies. Though composed of two kinds of architectures, PSTN is trained with one loss function in an end-to-end (E2E) manner, which can learn temporal and spatial correlations jointly. Experiments for short-term predictions are conducted on real-world data, whose results demonstrate that PSTN outperforms prior methods.
- 4 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (1) , 509-523
Learning Temporal and Spatial Correlations Jointly: A Unified Framework for Wind Speed Prediction
Leveraging both temporal and spatial correlations to predict wind speed remains one of the most challenging and less studied areas of wind speed prediction. In this paper, the problem of predicting wind speeds for multiple sites is investigated by using the spatio-temporal correlation. We proposed a deep architecture termed predictive spatio-temporal network (PSTN), which is a unified framework integrating a convolutional neural network (CNN) and a long short-term memory (LSTM). Initially, the spatial features are extracted from the spatial wind speed matrices (SWSMs) by the CNN at the bottom of the model. Then, the LSTM captures the temporal dependencies among the spatial features extracted from contiguous time points. Finally, the predicted wind speeds are given by the last state of the top layer of the LSTM, which are generated by using the spatial features and temporal dependencies. Though composed of two kinds of architectures, PSTN is trained with one loss function in an end-to-end (E2E) manner, which can learn temporal and spatial correlations jointly. Experiments for short-term predictions are conducted on real-world data, whose results demonstrate that PSTN outperforms prior methods.
- Open Access
Wind Speed Prediction with Spatio–Temporal Correlation: A Deep Learning Approach
Wind speed prediction with spatio–temporal correlation is among the most challenging tasks in wind speed prediction. In this paper, the problem of predicting wind speed for multiple sites simultaneously is investigated by using spatio–temporal correlation. This paper proposes a model for wind speed prediction with spatio–temporal correlation, i.e., the predictive deep convolutional neural network (PDCNN). The model is a unified framework, integrating convolutional neural networks (CNNs) and a multi-layer perceptron (MLP). Firstly, the spatial features are extracted by CNNs located at the bottom of the model. Then, the temporal dependencies among these extracted spatial features are captured by the MLP. In this way, the spatial and temporal correlations are captured by PDCNN intrinsically. Finally, PDCNN generates the predicted wind speed by using the learnt spatio–temporal correlations. In addition, three error indices are defined to evaluate the prediction accuracy of the model on the wind turbine array. Experiment results on real-world data show that PDCNN can capture the spatio–temporal correlation effectively, and it outperforms the conventional machine learning models, including multi-layer perceptron, support vector regressor, decision tree, etc.
Open AccessWind Speed Prediction with Spatio–Temporal Correlation: A Deep Learning Approach
Wind speed prediction with spatio–temporal correlation is among the most challenging tasks in wind speed prediction. In this paper, the problem of predicting wind speed for multiple sites simultaneously is investigated by using spatio–temporal correlation. This paper proposes a model for wind speed prediction with spatio–temporal correlation, i.e., the predictive deep convolutional neural network (PDCNN). The model is a unified framework, integrating convolutional neural networks (CNNs) and a multi-layer perceptron (MLP). Firstly, the spatial features are extracted by CNNs located at the bottom of the model. Then, the temporal dependencies among these extracted spatial features are captured by the MLP. In this way, the spatial and temporal correlations are captured by PDCNN intrinsically. Finally, PDCNN generates the predicted wind speed by using the learnt spatio–temporal correlations. In addition, three error indices are defined to evaluate the prediction accuracy of the model on the wind turbine array. Experiment results on real-world data show that PDCNN can capture the spatio–temporal correlation effectively, and it outperforms the conventional machine learning models, including multi-layer perceptron, support vector regressor, decision tree, etc.
- Open Access
Simplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation
AC (alternating current) system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC) into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC) simulations.
Open AccessSimplified Analytic Approach of Pole-to-Pole Faults in MMC-HVDC for AC System Backup Protection Setting Calculation
AC (alternating current) system backup protection setting calculation is an important basis for ensuring the safe operation of power grids. With the increasing integration of modular multilevel converter based high voltage direct current (MMC-HVDC) into power grids, it has been a big challenge for the AC system backup protection setting calculation, as the MMC-HVDC lacks the fault self-clearance capability under pole-to-pole faults. This paper focused on the pole-to-pole faults analysis for the AC system backup protection setting calculation. The principles of pole-to-pole faults analysis were discussed first according to the standard of the AC system protection setting calculation. Then, the influence of fault resistance on the fault process was investigated. A simplified analytic approach of pole-to-pole faults in MMC-HVDC for the AC system backup protection setting calculation was proposed. In the proposed approach, the derived expressions of fundamental frequency current are applicable under arbitrary fault resistance. The accuracy of the proposed approach was demonstrated by PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC) simulations.
- Open Access
New Approach for Optimal Location and Parameters Setting of UPFC for Enhancing Power Systems Stability under Contingency Analysis
Operation of power system within specified limits of voltage and frequency are the major concerns in power system stability studies. As power system is always prone to disturbances, which consequently affect the voltage instability and optimal power flow, and therefore risks the power systems stability and security. In this paper, a novel technique based on the “Artificial Algae Algorithm” (AAA) is introduced, to identify the optimal location and the parameters setting of Unified Power Flow Controller (UPFC) under N-1 contingency criterion. In the first part, we have carried out a contingency operation and ranking process for the most parlous lines outage contingencies while taking the transmission lines overloading (NOLL) and voltage violation of buses (NVVB) as a performance parameter (PP = NOLL + NVVB). As UPFC possesses too much prohibitive cost and larger size, its optimal location and size must be identified before the actual deployment. In the second part, we have applied a novel AAA technique to identify the optimal location and parameters setting of UPFC under the discovered contingencies. The simulations have been executed on IEEE 14 bus and 30 bus networks. The results reveals that the location of UPFC is significantly optimized using AAA technique, which has improved the stability and security of the power system by curtailing the overloaded transmission lines and limiting the voltage violations of buses.
Open AccessNew Approach for Optimal Location and Parameters Setting of UPFC for Enhancing Power Systems Stability under Contingency Analysis
Operation of power system within specified limits of voltage and frequency are the major concerns in power system stability studies. As power system is always prone to disturbances, which consequently affect the voltage instability and optimal power flow, and therefore risks the power systems stability and security. In this paper, a novel technique based on the “Artificial Algae Algorithm” (AAA) is introduced, to identify the optimal location and the parameters setting of Unified Power Flow Controller (UPFC) under N-1 contingency criterion. In the first part, we have carried out a contingency operation and ranking process for the most parlous lines outage contingencies while taking the transmission lines overloading (NOLL) and voltage violation of buses (NVVB) as a performance parameter (PP = NOLL + NVVB). As UPFC possesses too much prohibitive cost and larger size, its optimal location and size must be identified before the actual deployment. In the second part, we have applied a novel AAA technique to identify the optimal location and parameters setting of UPFC under the discovered contingencies. The simulations have been executed on IEEE 14 bus and 30 bus networks. The results reveals that the location of UPFC is significantly optimized using AAA technique, which has improved the stability and security of the power system by curtailing the overloaded transmission lines and limiting the voltage violations of buses.
- Open Access
Simultaneous Robust Coordinated Damping Control of Power System Stabilizers (PSSs), Static Var Compensator (SVC) and Doubly-Fed Induction Generator Power Oscillation Dampers (DFIG PODs) in Multimachine Power Systems
The potential of utilizing doubly-fed induction generator (DFIG)-based wind farms to improve power system damping performance and to enhance small signal stability has been proposed by many researchers. However, the simultaneous coordinated tuning of a DFIG power oscillation damper (POD) with other damping controllers is rarely involved. A simultaneous robust coordinated multiple damping controller design strategy for a power system incorporating power system stabilizer (PSS), static var compensator (SVC) POD and DFIG POD is presented in this paper. This coordinated damping control design strategy is addressed as an eigenvalue-based optimization problem to increase the damping ratios of oscillation modes. Both local and inter-area electromechanical oscillation modes are intended in the optimization design process. Wide-area phasor measurement unit (PMU) signals, selected by the joint modal controllability/ observability index, are utilized as SVC and DFIG POD feedback modulation signals to suppress inter-area oscillation modes. The robustness of the proposed coordinated design strategy is achieved by simultaneously considering multiple power flow situations and operating conditions. The recently proposed Grey Wolf optimizer (GWO) algorithm is adopted to efficiently optimize the parameter values of multiple damping controllers. The feasibility and effectiveness of the proposed coordinated design strategy are demonstrated through frequency-domain eigenvalue analysis and nonlinear time-domain simulation studies in two modified benchmark test systems. Moreover, the dynamic response simulation results also validate the robustness of the recommended coordinated multiple damping controllers under various system operating conditions.
Open AccessSimultaneous Robust Coordinated Damping Control of Power System Stabilizers (PSSs), Static Var Compensator (SVC) and Doubly-Fed Induction Generator Power Oscillation Dampers (DFIG PODs) in Multimachine Power Systems
The potential of utilizing doubly-fed induction generator (DFIG)-based wind farms to improve power system damping performance and to enhance small signal stability has been proposed by many researchers. However, the simultaneous coordinated tuning of a DFIG power oscillation damper (POD) with other damping controllers is rarely involved. A simultaneous robust coordinated multiple damping controller design strategy for a power system incorporating power system stabilizer (PSS), static var compensator (SVC) POD and DFIG POD is presented in this paper. This coordinated damping control design strategy is addressed as an eigenvalue-based optimization problem to increase the damping ratios of oscillation modes. Both local and inter-area electromechanical oscillation modes are intended in the optimization design process. Wide-area phasor measurement unit (PMU) signals, selected by the joint modal controllability/ observability index, are utilized as SVC and DFIG POD feedback modulation signals to suppress inter-area oscillation modes. The robustness of the proposed coordinated design strategy is achieved by simultaneously considering multiple power flow situations and operating conditions. The recently proposed Grey Wolf optimizer (GWO) algorithm is adopted to efficiently optimize the parameter values of multiple damping controllers. The feasibility and effectiveness of the proposed coordinated design strategy are demonstrated through frequency-domain eigenvalue analysis and nonlinear time-domain simulation studies in two modified benchmark test systems. Moreover, the dynamic response simulation results also validate the robustness of the recommended coordinated multiple damping controllers under various system operating conditions.
- 21 November 2008
- Published by Springer Nature in Science China Technological Sciences
- Vol. 52 (4) , 937-943
Transmitting electric power system dynamics in SCADA using polynomial fitting
- 21 November 2008
- Published by Springer Nature in Science China Technological Sciences
- Vol. 52 (4) , 937-943
Transmitting electric power system dynamics in SCADA using polynomial fitting