Xuesong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xuesong Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhao
North China Electric Power University
2 shared publications - De-Min Li
School of Electrical Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Jinsheng Xiao
State Key Laboratory of Light Superalloys, Wuhan University of Technology, Wuhan 430070, China
1 shared publication - Leiqi Zhang
State Grid Zhejiang Electric Power Research Institute, Hangzhou 310014, China
1 shared publication - Liang Tong
State Key Laboratory of Maritime Technology and Safety, Wuhan University of Technology, Wuhan 430063, China
1 shared publication - Min Liu
Research Institute of State Grid Zhejiang Electric Power Co., Ltd., Hangzhou 310006, China
1 shared publication
Latest Publications
- Open Access
- 18 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (12) , 9735
Parametric Study on Fin Structure and Injection Tube in Metal Hydride Tank Packed with LaNi5 Alloy for Efficient and Safe Hydrogen Storage
Efficient hydrogen storage methods are crucial for the large-scale application of hydrogen energy. This work studied the effects of fin structure and injection tube on the system performance of a hydrogen storage tank packed with LaNi5 alloy. An axisymmetric finite element model of the metal hydride hydrogen storage tank was established. The fin structure and injection tube were added to the hydrogen storage tank, and the effects of the fin location and injection tube on the efficiency and safety of the hydrogen storage tank during hydriding were analyzed. A parametric study on the wall fin structure and injection tube has been carried out to optimize the design of a hydrogen storage tank, and to improve its efficiency and safety. The hydrogen storage capacity of the optimized tank packed with LaNi5 alloy can reach 1.312 wt%, which is 99% of its maximum capacity, at around 650 s. The results show that the fin structure can improve the heat transfer performance of the storage tank, and that the injection tube can enhance the mass transfer of hydrogen in the tank.
- 18 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (12) , 9735
Open AccessParametric Study on Fin Structure and Injection Tube in Metal Hydride Tank Packed with LaNi5 Alloy for Efficient and Safe Hydrogen Storage
Efficient hydrogen storage methods are crucial for the large-scale application of hydrogen energy. This work studied the effects of fin structure and injection tube on the system performance of a hydrogen storage tank packed with LaNi5 alloy. An axisymmetric finite element model of the metal hydride hydrogen storage tank was established. The fin structure and injection tube were added to the hydrogen storage tank, and the effects of the fin location and injection tube on the efficiency and safety of the hydrogen storage tank during hydriding were analyzed. A parametric study on the wall fin structure and injection tube has been carried out to optimize the design of a hydrogen storage tank, and to improve its efficiency and safety. The hydrogen storage capacity of the optimized tank packed with LaNi5 alloy can reach 1.312 wt%, which is 99% of its maximum capacity, at around 650 s. The results show that the fin structure can improve the heat transfer performance of the storage tank, and that the injection tube can enhance the mass transfer of hydrogen in the tank.
- Open Access
An Improved Droop Control Strategy for Low-Voltage Microgrids Based on Distributed Secondary Power Optimization Control
To achieve accurate reactive power sharing and voltage frequency and amplitude restoration in low-voltage microgrids, a control strategy combining an improved droop control with distributed secondary power optimization control is proposed. The active and reactive power that each distributed generator (DG) shares is calculated by extracting load information and utilizing a power sharing ratio, and is reset to be the nominal power to recalculate droop gains. The droop control curves are reconstructed according to the nominal active and reactive power and the recalculated droop gains. The reconstructed active power-frequency droop control can regulate active power adaptively and keep frequency at a nominal value. Meanwhile, the reconstructed reactive power voltage droop control can reduce voltage amplitude deviation to a certain extent. A distributed secondary power optimization control is added to the reconstructed reactive power voltage droop control by using average system voltage. The average system voltage is obtained by using a consensus algorithm in a distributed, sparse communication network which is constituted by all controllers of DGs. As a result, accurate reactive power sharing is realized, average system voltage is kept at a nominal value, and all voltage amplitude deviations are further reduced. Due to the absence of a microgrid central controller, the reliability of the strategy is enhanced. Finally, the simulation results validate the proposed method.
Open AccessAn Improved Droop Control Strategy for Low-Voltage Microgrids Based on Distributed Secondary Power Optimization Control
To achieve accurate reactive power sharing and voltage frequency and amplitude restoration in low-voltage microgrids, a control strategy combining an improved droop control with distributed secondary power optimization control is proposed. The active and reactive power that each distributed generator (DG) shares is calculated by extracting load information and utilizing a power sharing ratio, and is reset to be the nominal power to recalculate droop gains. The droop control curves are reconstructed according to the nominal active and reactive power and the recalculated droop gains. The reconstructed active power-frequency droop control can regulate active power adaptively and keep frequency at a nominal value. Meanwhile, the reconstructed reactive power voltage droop control can reduce voltage amplitude deviation to a certain extent. A distributed secondary power optimization control is added to the reconstructed reactive power voltage droop control by using average system voltage. The average system voltage is obtained by using a consensus algorithm in a distributed, sparse communication network which is constituted by all controllers of DGs. As a result, accurate reactive power sharing is realized, average system voltage is kept at a nominal value, and all voltage amplitude deviations are further reduced. Due to the absence of a microgrid central controller, the reliability of the strategy is enhanced. Finally, the simulation results validate the proposed method.