Choon-Geun Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Choon-Geun Moon has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chang-Hyo Son
Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-Gu, Busan 48513, Republic of Korea
2 shared publications - Jung-In Yoon
Department of Refrigeration and Air-conditioning Engineering, College of Engineering, Pukyong National University, Busan 48513, Republic of Korea
2 shared publications - Hyun-Kyung Lee
Heating development project, Home appliance & Air solution, LG Electronics Inc., Changwon 51533, Korea
1 shared publication J H Yoon
Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University, 45 Yongso-ro, Busan, South Korea
1 shared publicationJ Y Kong
Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University, 45 Yongso-ro, Busan, South Korea
1 shared publication- Joon-Hyuk Lee
Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-Gu, Busan 48513, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 675 (1) , 012043
Performance characteristics of portable air conditioner with condensate-water spray
In this research, a device for injecting condensate-water generated from the evaporator into the distributor on the top of the condenser was fabricated as a method for improving the efficiency of the portable air conditioner. To compare the efficiency, the condensation temperature, blowout air temperature, power consumption, cooling capacity, and COP of the system were measured. As a result of the experiment, the condensation temperature dropped by about 6.2 °C. Also, the power consumption of the compressor was reduced by about 0.16 kW and the cooling capacity increased by 0.2 kW. As a result, it was confirmed that the COP increased by about 16 % when the condensate-water was sprayed on the condenser.
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 675 (1) , 012043
Open AccessPerformance characteristics of portable air conditioner with condensate-water spray
In this research, a device for injecting condensate-water generated from the evaporator into the distributor on the top of the condenser was fabricated as a method for improving the efficiency of the portable air conditioner. To compare the efficiency, the condensation temperature, blowout air temperature, power consumption, cooling capacity, and COP of the system were measured. As a result of the experiment, the condensation temperature dropped by about 6.2 °C. Also, the power consumption of the compressor was reduced by about 0.16 kW and the cooling capacity increased by 0.2 kW. As a result, it was confirmed that the COP increased by about 16 % when the condensate-water was sprayed on the condenser.
- Open Access
- 25 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (11) , 2063
Performance Characteristics of a Seawater Ice-Making Device Using a Scraped Surface Double Tube Evaporator
In this study, to investigate the performance characteristics of a seawater ice-making device, using a scraped surface double tube evaporator, experiments were conducted under various operating conditions, including inlet temperature and flow rate of seawater, evaporating temperature, and scraper rotation speed. The main results are summarized as follows: (1) The section where stable ice making is possible, is determined by the inlet temperature and the flow rate range of seawater. By controlling the flow rate of seawater, the ice packing factor (IPF) of the device can be adjusted from 0.3 to 14.7%. (2) The IPF increases in cases where the evaporating temperature decreases linearly, until −13 °C. As the temperature of refrigerant that flows into the evaporator changes, the IPF is changed. Consideration is required for these connections. (3) The IPF increases when speeding up the scraper. The minimum rotating speed of the scraper was 350 rpm in these experiments. Optimum operating conditions for the seawater ice slurry maker are established through experiments. These results will be considered as important data for designing a slurry type seawater ice-making device.
- 25 October 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (11) , 2063
Open AccessPerformance Characteristics of a Seawater Ice-Making Device Using a Scraped Surface Double Tube Evaporator
In this study, to investigate the performance characteristics of a seawater ice-making device, using a scraped surface double tube evaporator, experiments were conducted under various operating conditions, including inlet temperature and flow rate of seawater, evaporating temperature, and scraper rotation speed. The main results are summarized as follows: (1) The section where stable ice making is possible, is determined by the inlet temperature and the flow rate range of seawater. By controlling the flow rate of seawater, the ice packing factor (IPF) of the device can be adjusted from 0.3 to 14.7%. (2) The IPF increases in cases where the evaporating temperature decreases linearly, until −13 °C. As the temperature of refrigerant that flows into the evaporator changes, the IPF is changed. Consideration is required for these connections. (3) The IPF increases when speeding up the scraper. The minimum rotating speed of the scraper was 350 rpm in these experiments. Optimum operating conditions for the seawater ice slurry maker are established through experiments. These results will be considered as important data for designing a slurry type seawater ice-making device.