WWWeixiang Wu

Weixiang Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weixiang Wu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Qiang Zhao

    Department of Clinical Laboratory, The First Affiliated Hospital of Zhengzhou University, Key Clinical Laboratory of Henan Province, Zhengzhou, Henan, China

    2 shared publications
  • Qing Lu

    Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China

    2 shared publications
  • Guangxia Yu

    Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health (Incubating), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China

    1 shared publication
  • Shunli Jiang

    School of Public Health, Jining Medical University, Jining 272013, China

    1 shared publication
  • Tong Zhou

    Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China

    1 shared publication
  • Xiaoqi Pan

    Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health (Incubating), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China

    1 shared publication

Latest Publications

  • Open Access

    Zwitterionic Surfactant Modified Acetylene Black Paste Electrode for Highly Facile and Sensitive Determination of Tetrabromobisphenol A

    by Xiaoyun Wei, Qiang Zhao, Weixiang Wu, Tong Zhou, Shunli Jiang, Yeqing Tong, Qing Lu

    A electrochemical sensor for the highly sensitive detection of tetrabromobisphenol A (TBBPA) was fabricated based on acetylene black paste electrode (ABPE) modified with 3-(N,N-Dimethylpalmitylammonio) propanesulfonate (SB3-16) in this study. The peak current of TBBPA was significantly enhanced at SB3-16/ABPE compared with unmodified electrodes. To further improve the electrochemical performance of the modified electrode, corresponding experimental parameters such as the length of hydrophobic chains of zwitterionic surfactant, the concentration of SB3-16, pH value, and accumulation time were examined. The peak currents of TBBPA were found to be linearly correlated with its concentrations in the range of 1 nM to 1 µM, with a detection limit of 0.4 nM. Besides, a possible mechanism was also discussed, and the hydrophobic interaction between TBBPA and the surfactants was suggested to take a leading role in enhancing the responses. Finally, this sensor was successfully employed to detect TBBPA in water samples.


  • Open Access

    High Sensitive and Selective Sensing of Hydrogen Peroxide Released from Pheochromocytoma Cells Based on Pt-Au Bimetallic Nanoparticles Electrodeposited on Reduced Graphene Sheets

    by Guangxia Yu, Weixiang Wu, Xiaoqi Pan, Qiang Zhao, Xiaoyun Wei, Qing Lu

    In this study, a high sensitive and selective hydrogen peroxide (H2O2) sensor was successfully constructed with Pt-Au bimetallic nanoparticles (Pt-Au NPs)/reduced graphene sheets (rGSs) hybrid films. Various molar ratios of Au to Pt and different electrodeposition conditions were evaluated to control the morphology and electrocatalytic activity of the Pt-Au bimetallic nanoparticles. Upon optimal conditions, wide linear ranges from 1 µM to 1.78 mM and 1.78 mM to 16.8 mM were obtained, with a detection limit as low as 0.31 µM. Besides, due to the synergetic effects of the bimetallic NPs and rGSs, the amperometric H2O2 sensor could operate at a low potential of 0 V. Under this potential, not only common anodic interferences induced from ascorbic acid, uric acid and dopamine, but also the cathodic interference induced from endogenous O2 could be effectively avoided. Furthermore, with rat pheochromocytoma cells (PC 12) as model, the proposed sensor had been successfully used in the detection of H2O2 released from the cancer cells. This method with wide linear ranges and excellent selectivity can provide a promising alternative for H2O2 monitoring in vivo in the fields of physiology, pathology and diagnosis.