Hongzhi Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongzhi Jiang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Xudong Li
Beihang University
9 shared publicationsHuijie Zhao
Beihang University
6 shared publications- Huijie Zhao
Beihang University
5 shared publications Yang Xu
Northwest University
3 shared publicationsBingjie Xu
School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Key Laboratory of Precision Opto-Mechatronics Technology, Ministry of Education, Xueyuan Road 37#, Haidian District, Beijing, 100191, China
2 shared publicationsShuguang Zhu
School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Key Laboratory of Precision Opto-Mechatronics Technology, Ministry of Education, Xueyuan Road 37#, Haidian District, Beijing, 100191, China
2 shared publications
Latest Publications
- 3 June 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (12) , 22277-22291
Simulation framework for fringe projection profilometry using ray tracing and light transport coefficient measurement
Fringe projection profilometry is widely used in optical metrology, and fringe analysis is important to improve measurement accuracy. However, the fringe images captured by cameras are influenced by many factors, an analytical study of which, to characterize the imaging process, is difficult to perform. We propose a method to accurately simulate the real imaging system in the virtual environment using ray tracing algorithm. The light transport coefficients of the cameras are measured to simulate defocus instead of using Gaussian function. Experimental results show that the proposed method can simulate a physical system in the virtual environment more accurately than the Gaussian function at large defocus condition.
- 3 June 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (12) , 22277-22291
Simulation framework for fringe projection profilometry using ray tracing and light transport coefficient measurement
Fringe projection profilometry is widely used in optical metrology, and fringe analysis is important to improve measurement accuracy. However, the fringe images captured by cameras are influenced by many factors, an analytical study of which, to characterize the imaging process, is difficult to perform. We propose a method to accurately simulate the real imaging system in the virtual environment using ray tracing algorithm. The light transport coefficients of the cameras are measured to simulate defocus instead of using Gaussian function. Experimental results show that the proposed method can simulate a physical system in the virtual environment more accurately than the Gaussian function at large defocus condition.
- 7 September 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (19) , 30543-30557
Paraxial 3D shape measurement using parallel single-pixel imaging
Three-dimensional (3D) shape measurement with fringe projection technique and vertical scanning setup can alleviate the problem of shadow and occlusion. However, the shape-from-defocus based method suffers from limited sensitivity and low signal-to-noise ratio (SNR), whereas the projection-triangulation based is sensitive to the zero-phase detection. In this paper, we propose paraxial 3D shape measurement using parallel single-pixel imaging (PSI). The depth is encoded in the radial distance to the projector optical center, which is determined by the projection of light transport coefficients (LTCs). The third-order polynomial fitting is used for depth mapping and calibration. Experiments on 5 objects with different materials and textures are conducted, and standards are measured to test the accuracy. The results verified that the proposed method can achieve robust, dense reconstruction with depth accuracy at 20 μm while the root-mean-square error (RMSE) of plane fitting up to 43 μm.
- 7 September 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (19) , 30543-30557
Paraxial 3D shape measurement using parallel single-pixel imaging
Three-dimensional (3D) shape measurement with fringe projection technique and vertical scanning setup can alleviate the problem of shadow and occlusion. However, the shape-from-defocus based method suffers from limited sensitivity and low signal-to-noise ratio (SNR), whereas the projection-triangulation based is sensitive to the zero-phase detection. In this paper, we propose paraxial 3D shape measurement using parallel single-pixel imaging (PSI). The depth is encoded in the radial distance to the projector optical center, which is determined by the projection of light transport coefficients (LTCs). The third-order polynomial fitting is used for depth mapping and calibration. Experiments on 5 objects with different materials and textures are conducted, and standards are measured to test the accuracy. The results verified that the proposed method can achieve robust, dense reconstruction with depth accuracy at 20 μm while the root-mean-square error (RMSE) of plane fitting up to 43 μm.
- Open Access
- 17 June 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (13) , 18421-18434
High-accuracy 3D shape measurement of translucent objects by fringe projection profilometry
Acquiring complete and accurate 3D shape measurement results of translucent objects by fringe projection profilometry (FPP) is difficult because of the subsurface scattering effect. The phase offset introduces geometric errors, and the degraded image contrast leads to incomplete measurement results and random errors. In this research, a high-accuracy 3D shape measurement method for translucent objects based on phase-shifting FPP is proposed. The relationship between fringe period and phase error is investigated to determine the fringe periods. Random errors are suppressed by temporal noise reduction, and the robustness of multi-frequency heterodyne phase unwrapping is improved by increasing the interval of fringe periods along with temporal noise reduction. Geometric errors are compensated for by projecting multi-frequency fringe patterns to establish the relationship between fringe period and depth offset. Experimental results show that the proposed method can acquire complete measurement results and significantly reduce the overall error for measuring translucent objects.
- 17 June 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (13) , 18421-18434
Open AccessHigh-accuracy 3D shape measurement of translucent objects by fringe projection profilometry
Acquiring complete and accurate 3D shape measurement results of translucent objects by fringe projection profilometry (FPP) is difficult because of the subsurface scattering effect. The phase offset introduces geometric errors, and the degraded image contrast leads to incomplete measurement results and random errors. In this research, a high-accuracy 3D shape measurement method for translucent objects based on phase-shifting FPP is proposed. The relationship between fringe period and phase error is investigated to determine the fringe periods. Random errors are suppressed by temporal noise reduction, and the robustness of multi-frequency heterodyne phase unwrapping is improved by increasing the interval of fringe periods along with temporal noise reduction. Geometric errors are compensated for by projecting multi-frequency fringe patterns to establish the relationship between fringe period and depth offset. Experimental results show that the proposed method can acquire complete measurement results and significantly reduce the overall error for measuring translucent objects.
- Open Access
SWIR AOTF Imaging Spectrometer Based on Single-pixel Imaging
An acousto-optic tunable filter (AOTF) is a new type of mono-wavelength generator, and an AOTF imaging spectrometer can obtain spectral images of interest. However, due to the limitation of AOTF aperture and acceptance angle, the light passing through the AOTF imaging spectrometer is weak, especially in the short-wave infrared (SWIR) region. In weak light conditions, the noise of a non-deep cooling mercury cadmium telluride (MCT) detector is high compared to the camera response. Thus, effective spectral images cannot be obtained. In this study, the single-pixel imaging (SPI) technique was applied to the AOTF imaging spectrometer, which can obtain spectral images due to the short-focus lens that collects light into a small area. In our experiment, we proved that the irradiance of a short-focus system is much higher than that of a long-focus system in relation to the AOTF imaging spectrometer. Then, an SPI experimental setup was built to obtain spectral images in which traditional systems cannot obtain. This work provides an efficient way to detect spectral images from 1000 to 2200 nm.
Open AccessSWIR AOTF Imaging Spectrometer Based on Single-pixel Imaging
An acousto-optic tunable filter (AOTF) is a new type of mono-wavelength generator, and an AOTF imaging spectrometer can obtain spectral images of interest. However, due to the limitation of AOTF aperture and acceptance angle, the light passing through the AOTF imaging spectrometer is weak, especially in the short-wave infrared (SWIR) region. In weak light conditions, the noise of a non-deep cooling mercury cadmium telluride (MCT) detector is high compared to the camera response. Thus, effective spectral images cannot be obtained. In this study, the single-pixel imaging (SPI) technique was applied to the AOTF imaging spectrometer, which can obtain spectral images due to the short-focus lens that collects light into a small area. In our experiment, we proved that the irradiance of a short-focus system is much higher than that of a long-focus system in relation to the AOTF imaging spectrometer. Then, an SPI experimental setup was built to obtain spectral images in which traditional systems cannot obtain. This work provides an efficient way to detect spectral images from 1000 to 2200 nm.
- 25 July 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (16) , 20351-20367
Defocusing parameter selection strategies based on PSF measurement for square-binary defocusing fringe projection profilometry
Three-dimensional (3D) shape measurement system with binary defocusing technique can perform high-speed and flexible measurements if binary fringe patterns are defocused by projector properly. However, the actual defocusing degree is difficult to set, and the fringe period is difficult to determine accordingly. In this study, we present a square-binary defocusing parameter selection framework. First, we analyze the fringe formation process mathematically. The defocusing degree is quantified and manipulated by using the focusing distance of projector, which is calibrated by point spread function measurement. To optimize parameter selection, single-point sinusoidal error is modeled as the objective function for the evaluation of the defocusing effect. We verify the correctness by using different parameter combinations and object measurements in our experiments. The appropriate defocusing parameters can be easily obtained according to the analysis of practical system setup, which improves the quality and robustness of the system.
- 25 July 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (16) , 20351-20367
Defocusing parameter selection strategies based on PSF measurement for square-binary defocusing fringe projection profilometry
Three-dimensional (3D) shape measurement system with binary defocusing technique can perform high-speed and flexible measurements if binary fringe patterns are defocused by projector properly. However, the actual defocusing degree is difficult to set, and the fringe period is difficult to determine accordingly. In this study, we present a square-binary defocusing parameter selection framework. First, we analyze the fringe formation process mathematically. The defocusing degree is quantified and manipulated by using the focusing distance of projector, which is calibrated by point spread function measurement. To optimize parameter selection, single-point sinusoidal error is modeled as the objective function for the evaluation of the defocusing effect. We verify the correctness by using different parameter combinations and object measurements in our experiments. The appropriate defocusing parameters can be easily obtained according to the analysis of practical system setup, which improves the quality and robustness of the system.
- 8 March 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (6) , 7117-7131
3D shape measurement in the presence of strong interreflections by epipolar imaging and regional fringe projection
A 3D shape measurement method in the presence of strong interreflections is presented. Traditional optical 3D shape measurement methods such as fringe projection profilometry (FPP) cannot measure regions that contain strong interreflections, which result in 3D shape measurement failure. In the proposed method, epipolar imaging with speckle patterns is utilized to eliminate the effects of interreflections and obtain the initial 3D shape measurement result. Regional fringe projection based on the initial measurement result is further applied to achieve high-accuracy measurement. Experimental results show that the proposed method can measure the regions that contain strong interreflections at a high accuracy.
- 8 March 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (6) , 7117-7131
3D shape measurement in the presence of strong interreflections by epipolar imaging and regional fringe projection
A 3D shape measurement method in the presence of strong interreflections is presented. Traditional optical 3D shape measurement methods such as fringe projection profilometry (FPP) cannot measure regions that contain strong interreflections, which result in 3D shape measurement failure. In the proposed method, epipolar imaging with speckle patterns is utilized to eliminate the effects of interreflections and obtain the initial 3D shape measurement result. Regional fringe projection based on the initial measurement result is further applied to achieve high-accuracy measurement. Experimental results show that the proposed method can measure the regions that contain strong interreflections at a high accuracy.
- 16 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (4) , 5005-5017
Projector-defocusing rectification for Fourier single-pixel imaging
Fourier single-pixel imaging (FSI) is an efficient single-pixel imaging method of obtaining high-quality (resolution/signal-to-noise ratio) 2D images, which projects sinusoid patterns on the object and reconstructs the image through reflected light. The typical system of FSI consists of a single-pixel detector and a digital projector. However, the defocusing of the projector lens blurs the projected patterns, which results in reduced imaging quality. In this work, we propose the projector-defocusing rectification for FSI, which optimizes projector defocusing for the first time. The proposed method rectifies Fourier coefficients using the amplitude ratio between original and defocused patterns, which we can acquire through a controlled experiment on a whiteboard. The enhancement of imaging quality in imperfect circumstances is demonstrated by simulations and experiments.
- 16 February 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (4) , 5005-5017
Projector-defocusing rectification for Fourier single-pixel imaging
Fourier single-pixel imaging (FSI) is an efficient single-pixel imaging method of obtaining high-quality (resolution/signal-to-noise ratio) 2D images, which projects sinusoid patterns on the object and reconstructs the image through reflected light. The typical system of FSI consists of a single-pixel detector and a digital projector. However, the defocusing of the projector lens blurs the projected patterns, which results in reduced imaging quality. In this work, we propose the projector-defocusing rectification for FSI, which optimizes projector defocusing for the first time. The proposed method rectifies Fourier coefficients using the amplitude ratio between original and defocused patterns, which we can acquire through a controlled experiment on a whiteboard. The enhancement of imaging quality in imperfect circumstances is demonstrated by simulations and experiments.
- Open Access
- 21 June 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (13) , 15118-15130
Adaptive regional single-pixel imaging based on the Fourier slice theorem
Single-pixel imaging (SPI) is a novel method for capturing high-quality 2D images of scenes using a non-spatially-resolved detector. While implementing conventional SPI, a huge number of illuminated patterns are projected onto the object to reconstruct a sharp image. For a situation in which the object occupies part of the illuminated region, we propose an adaptive regional SPI method (ARSI) to decrease the number of projected patterns. In the ARSI scheme, the object region is adaptively located based on the Fourier slice theorem. Then, the illuminated patterns are projected only onto the object region to facilitate imaging efficiency. Experiments demonstrate that the proposed ARSI method can achieve sharp image reconstruction with a substantial reduction in pattern number, thereby improving imaging efficiency.
- 21 June 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (13) , 15118-15130
Open AccessAdaptive regional single-pixel imaging based on the Fourier slice theorem
Single-pixel imaging (SPI) is a novel method for capturing high-quality 2D images of scenes using a non-spatially-resolved detector. While implementing conventional SPI, a huge number of illuminated patterns are projected onto the object to reconstruct a sharp image. For a situation in which the object occupies part of the illuminated region, we propose an adaptive regional SPI method (ARSI) to decrease the number of projected patterns. In the ARSI scheme, the object region is adaptively located based on the Fourier slice theorem. Then, the illuminated patterns are projected only onto the object region to facilitate imaging efficiency. Experiments demonstrate that the proposed ARSI method can achieve sharp image reconstruction with a substantial reduction in pattern number, thereby improving imaging efficiency.
- Open Access
- 26 April 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (9) , 10413-10433
Calibration of AOTF-based 3D measurement system using multiplane model based on phase fringe and BP neural network
A specifically designed imaging system based on an acousto-optic tunable filter (AOTF) can integrate hyperspectral imaging and 3D reconstruction. As a result of the complicated optical structure, the AOTF imaging system deviates from the traditional pinhole model and lens distortion form, causing difficulty to achieve precise camera calibration. The influencing factors leading to the deviation are discussed and a multiplane model (MPM) is proposed with phase fringe to produce dense mark points and a back propagation neural network to obtain subpixel calibration. Experiments show that MPM can reduce the back projection error efficiently compared with the pinhole model. A 3D reconstruction process is conducted based on the calibration result to verify the feasibility of the proposed method.
- 26 April 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (9) , 10413-10433
Open AccessCalibration of AOTF-based 3D measurement system using multiplane model based on phase fringe and BP neural network
A specifically designed imaging system based on an acousto-optic tunable filter (AOTF) can integrate hyperspectral imaging and 3D reconstruction. As a result of the complicated optical structure, the AOTF imaging system deviates from the traditional pinhole model and lens distortion form, causing difficulty to achieve precise camera calibration. The influencing factors leading to the deviation are discussed and a multiplane model (MPM) is proposed with phase fringe to produce dense mark points and a back propagation neural network to obtain subpixel calibration. Experiments show that MPM can reduce the back projection error efficiently compared with the pinhole model. A 3D reconstruction process is conducted based on the calibration result to verify the feasibility of the proposed method.
- Open Access
- 11 April 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (8) , 9171-9185
High-speed triangular pattern phase-shifting 3D measurement based on the motion blur method
Recent advancements in 3D measurement technologies have increased the urgency of requiring high-speed 3D measurement in many fields. This study presents a novel four-step triangular pattern phase-shifting 3D measurement using the motion blur method, which combines the advantages of phase-shifting methods. To comply with the high speed requirement, binary coded triangular patterns are projected and could dither vertically. Therefore, the image captured by the camera is blurred into grayscale-intensity triangular patterns, which can be used for phase unwrapping and 3D reconstruction. The proposed method decreased the projection time compared with sinusoidal patterns using a DMD (digital micromirror device) projector. Furthermore, this study presents a four-step triangular phase-shifting unwrapping algorithm. The experiments indicate that the proposed method can achieve high-speed 3D measurement and reconstruction.
- 11 April 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (8) , 9171-9185
Open AccessHigh-speed triangular pattern phase-shifting 3D measurement based on the motion blur method
Recent advancements in 3D measurement technologies have increased the urgency of requiring high-speed 3D measurement in many fields. This study presents a novel four-step triangular pattern phase-shifting 3D measurement using the motion blur method, which combines the advantages of phase-shifting methods. To comply with the high speed requirement, binary coded triangular patterns are projected and could dither vertically. Therefore, the image captured by the camera is blurred into grayscale-intensity triangular patterns, which can be used for phase unwrapping and 3D reconstruction. The proposed method decreased the projection time compared with sinusoidal patterns using a DMD (digital micromirror device) projector. Furthermore, this study presents a four-step triangular phase-shifting unwrapping algorithm. The experiments indicate that the proposed method can achieve high-speed 3D measurement and reconstruction.