Fujiang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fujiang Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jianhong Yang
College of Mechanical Engineering and Automation, Huaqiao University, Xiamen, Fujian, China
2 shared publications - Kai Yang
Key Laboratory of Process Monitoring and System Optimization for Mechanical and Electrical Equipment (Fujian Provincial Department of Education), College of Mechanical Engineering and Automation, Huaqiao University, Xiamen 361021, China
2 shared publications - Rencheng Zhang
Key Laboratory of Process Monitoring and System Optimization for Mechanical and Electrical Equipment (Fujian Provincial Department of Education), College of Mechanical Engineering and Automation, Huaqiao University, Xiamen 361021, China
2 shared publications - Shouhong Chen
College of Mechanical Engineering and Automation, Huaqiao University, Xiamen 361021, China
2 shared publications - Canhua Liu
College of Mechanical Engineering and Automation, Huaqiao University, Xiamen 361021, China
1 shared publication Wenbin Liu
Department of Joint Reconstruction, Tianjin Hospital, Tianjin Medical University, Tianjin 300210, China
1 shared publication
Latest Publications
- Open Access
A Novel Arc Fault Detector for Early Detection of Electrical Fires
Arc faults can produce very high temperatures and can easily ignite combustible materials; thus, they represent one of the most important causes of electrical fires. The application of arc fault detection, as an emerging early fire detection technology, is required by the National Electrical Code to reduce the occurrence of electrical fires. However, the concealment, randomness and diversity of arc faults make them difficult to detect. To improve the accuracy of arc fault detection, a novel arc fault detector (AFD) is developed in this study. First, an experimental arc fault platform is built to study electrical fires. A high-frequency transducer and a current transducer are used to measure typical load signals of arc faults and normal states. After the common features of these signals are studied, high-frequency energy and current variations are extracted as an input eigenvector for use by an arc fault detection algorithm. Then, the detection algorithm based on a weighted least squares support vector machine is designed and successfully applied in a microprocessor. Finally, an AFD is developed. The test results show that the AFD can detect arc faults in a timely manner and interrupt the circuit power supply before electrical fires can occur. The AFD is not influenced by cross talk or transient processes, and the detection accuracy is very high. Hence, the AFD can be installed in low-voltage circuits to monitor circuit states in real-time to facilitate the early detection of electrical fires.
Open AccessA Novel Arc Fault Detector for Early Detection of Electrical Fires
Arc faults can produce very high temperatures and can easily ignite combustible materials; thus, they represent one of the most important causes of electrical fires. The application of arc fault detection, as an emerging early fire detection technology, is required by the National Electrical Code to reduce the occurrence of electrical fires. However, the concealment, randomness and diversity of arc faults make them difficult to detect. To improve the accuracy of arc fault detection, a novel arc fault detector (AFD) is developed in this study. First, an experimental arc fault platform is built to study electrical fires. A high-frequency transducer and a current transducer are used to measure typical load signals of arc faults and normal states. After the common features of these signals are studied, high-frequency energy and current variations are extracted as an input eigenvector for use by an arc fault detection algorithm. Then, the detection algorithm based on a weighted least squares support vector machine is designed and successfully applied in a microprocessor. Finally, an AFD is developed. The test results show that the AFD can detect arc faults in a timely manner and interrupt the circuit power supply before electrical fires can occur. The AFD is not influenced by cross talk or transient processes, and the detection accuracy is very high. Hence, the AFD can be installed in low-voltage circuits to monitor circuit states in real-time to facilitate the early detection of electrical fires.
- Open Access
- 16 October 2015
- Published by MDPI AG in Algorithms
- Vol. 8 (4) , 929-950
Series Arc Fault Detection Algorithm Based on Autoregressive Bispectrum Analysis
Arc fault is one of the most critical reasons for electrical fires. Due to the diversity, randomness and concealment of arc faults in low-voltage circuits, it is difficult for general methods to protect all loads from series arc faults. From the analysis of many series arc faults, a large number of high frequency signals generated in circuits are found. These signals are easily affected by Gaussian noise which is difficult to be eliminated as a result of frequency aliasing. Thus, a novel detection algorithm is developed to accurately detect series arc faults in this paper. Initially, an autoregressive model of the mixed high frequency signals is modelled. Then, autoregressive bispectrum analysis is introduced to analyze common series arc fault features. The phase information of arc fault signal is preserved using this method. The influence of Gaussian noise is restrained effectively. Afterwards, several features including characteristic frequency, fluctuation of phase angles, diffused distribution and incremental numbers of bispectrum peaks are extracted for recognizing arc faults. Finally, least squares support vector machine is used to accurately identify series arc faults from the load states based on these frequency features of bispectrum. The validity of the algorithm is experimentally verified obtaining arc fault detection rate above 97%.
- 16 October 2015
- Published by MDPI AG in Algorithms
- Vol. 8 (4) , 929-950
Open AccessSeries Arc Fault Detection Algorithm Based on Autoregressive Bispectrum Analysis
Arc fault is one of the most critical reasons for electrical fires. Due to the diversity, randomness and concealment of arc faults in low-voltage circuits, it is difficult for general methods to protect all loads from series arc faults. From the analysis of many series arc faults, a large number of high frequency signals generated in circuits are found. These signals are easily affected by Gaussian noise which is difficult to be eliminated as a result of frequency aliasing. Thus, a novel detection algorithm is developed to accurately detect series arc faults in this paper. Initially, an autoregressive model of the mixed high frequency signals is modelled. Then, autoregressive bispectrum analysis is introduced to analyze common series arc fault features. The phase information of arc fault signal is preserved using this method. The influence of Gaussian noise is restrained effectively. Afterwards, several features including characteristic frequency, fluctuation of phase angles, diffused distribution and incremental numbers of bispectrum peaks are extracted for recognizing arc faults. Finally, least squares support vector machine is used to accurately identify series arc faults from the load states based on these frequency features of bispectrum. The validity of the algorithm is experimentally verified obtaining arc fault detection rate above 97%.
- 1 January 2014
- Vol. 127 (9) , 1791-3
Clinical outcomes of primary rotating-hinge knee arthroplasty for knees with severe deformity.
- 1 January 2014
- Vol. 127 (9) , 1791-3
Clinical outcomes of primary rotating-hinge knee arthroplasty for knees with severe deformity.