Chengyin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chengyin Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Xiaoqiu Shao
3 shared publications- Xiaoya Hu
School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China
3 shared publications Gongjun Yang
2 shared publicationsHuaiguo Xue
2 shared publicationsQingxiu Liu
2 shared publicationsXiaoya Hu
2 shared publications
Latest Publications
- Open Access
Voltammetric Determination of Dopamine in Human Serum with Amphiphilic Chitosan Modified Glassy Carbon Electrode
An improvement of selectivity for electrochemical detection of dopamine (DA)with differential pulse voltammetry is achieved by covalently modifying a glassy carbonelectrode (GCE) with O-carboxymethylchitosan (OCMCS). The amphiphilic chitosanprovides electrostatic accumulation of DA onto the electrode surface. In a phosphate buffersolution (pH 6.0), a pair of well-defined reversible redox waves of DA was observed at theOCMCS/GCE with a δEp of 52 mV. The anodic peak current obtained from thedifferential pulse voltammetry of dopamine was linearly dependent on its concentration inthe range of 6.0 × 10-8 to 7.0 × 10-6 M, with a correlation coefficient of 0.998. Thedetection limit (S/N = 3) was found to be 1.5 × 10-9 M. The modified electrode had beenapplied to the determination of DA in human serum samples with satisfactory results.
Open AccessVoltammetric Determination of Dopamine in Human Serum with Amphiphilic Chitosan Modified Glassy Carbon Electrode
An improvement of selectivity for electrochemical detection of dopamine (DA)with differential pulse voltammetry is achieved by covalently modifying a glassy carbonelectrode (GCE) with O-carboxymethylchitosan (OCMCS). The amphiphilic chitosanprovides electrostatic accumulation of DA onto the electrode surface. In a phosphate buffersolution (pH 6.0), a pair of well-defined reversible redox waves of DA was observed at theOCMCS/GCE with a δEp of 52 mV. The anodic peak current obtained from thedifferential pulse voltammetry of dopamine was linearly dependent on its concentration inthe range of 6.0 × 10-8 to 7.0 × 10-6 M, with a correlation coefficient of 0.998. Thedetection limit (S/N = 3) was found to be 1.5 × 10-9 M. The modified electrode had beenapplied to the determination of DA in human serum samples with satisfactory results.
- 1 October 2006
- Published by Elsevier in Electrochimica Acta
- Vol. 52 (2) , 704-709
One step fabrication and characterization of platinum nanopore electrode ensembles formed via amphiphilic block copolymer self-assembly
- 1 October 2006
- Published by Elsevier in Electrochimica Acta
- Vol. 52 (2) , 704-709
One step fabrication and characterization of platinum nanopore electrode ensembles formed via amphiphilic block copolymer self-assembly
- Open Access
Voltammetric Determination of Meloxicam in Pharmaceutical Formulation and Human Serum at Glassy Carbon Electrode Modified by Cysteic Acid Formed by Electrochemical Oxidation of L-cysteine
The improvement of electrochemical detection of meloxicam is presented bymodification of a glassy carbon electrode with anionic layer of cysteic acid providingelectrostatic accumulation of the analyte onto the electrode surface. The modificationformed by electrochemical oxidation of L-cysteine was performed by cycling potential incysteine solution. The anodic peak current obtained at 1.088 V (vs. Ag/AgCl) byvoltammetry was linearly dependent on the meloxicam concentration in the range of 4.3 ×10-8 ~ 8.5 × 10-6 M in the B-R buffer solution (0.04 M, pH 1.86) with a correlationcoefficient of 0.999. The detection limit (S/N = 3) is 1.5 × 10-9 M. The low-cost modifiedelectrode shows good sensitivity, selectivity and stability and has been applied to thedetermination of meloxicam in pharmaceutical formulation and spiked serum withsatisfactory results. The electrochemical reaction mechanism of meloxicam was discussed.
Open AccessVoltammetric Determination of Meloxicam in Pharmaceutical Formulation and Human Serum at Glassy Carbon Electrode Modified by Cysteic Acid Formed by Electrochemical Oxidation of L-cysteine
The improvement of electrochemical detection of meloxicam is presented bymodification of a glassy carbon electrode with anionic layer of cysteic acid providingelectrostatic accumulation of the analyte onto the electrode surface. The modificationformed by electrochemical oxidation of L-cysteine was performed by cycling potential incysteine solution. The anodic peak current obtained at 1.088 V (vs. Ag/AgCl) byvoltammetry was linearly dependent on the meloxicam concentration in the range of 4.3 ×10-8 ~ 8.5 × 10-6 M in the B-R buffer solution (0.04 M, pH 1.86) with a correlationcoefficient of 0.999. The detection limit (S/N = 3) is 1.5 × 10-9 M. The low-cost modifiedelectrode shows good sensitivity, selectivity and stability and has been applied to thedetermination of meloxicam in pharmaceutical formulation and spiked serum withsatisfactory results. The electrochemical reaction mechanism of meloxicam was discussed.
- 1 September 2006
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 42 (2) , 237-244
Differential pulse voltammetric determination of nimesulide in pharmaceutical formulation and human serum at glassy carbon electrode modified by cysteic acid/CNTs based on electrochemical oxidation of l-cysteine
- 1 September 2006
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 42 (2) , 237-244
Differential pulse voltammetric determination of nimesulide in pharmaceutical formulation and human serum at glassy carbon electrode modified by cysteic acid/CNTs based on electrochemical oxidation of l-cysteine