Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jae-Hyeong Seo has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Study on Heating Performances of Integrated Battery and HVAC System with Serial and Parallel Circuits for Electric Vehicle

    by Taek-Kyu Lim, Kunal Sandip Garud, Jae-Hyeong Seo, Moo-Yeon Lee, Dong-Yeon Lee

    The objective of the present study is to conduct experiments for investigating heating performances of integrated system with serial and parallel circuits for battery and heating ventilation and air conditioning system (HVAC) of electric vehicles under various operating conditions. In addition, the artificial neural network (ANN) model is proposed to accurately predict the heating performances of integrated system with serial and parallel circuits for battery and HVAC. A test bench of integrated system with serial and parallel circuits has been developed for establishing the trade-off between battery heating and HVAC heating. The heating performances namely, battery out temperature, battery temperature rise rate, battery heating capacity, HVAC heating capacity and total heating capacity are evaluated experimentally for the integrated system with serial and parallel circuits. The behavior of various heating performances is evaluated under influence of flow rate and heater power. Battery out temperature reaches 40 °C within 10 min with rise rate of 2.17 °C/min for the integrated system with serial circuit and that within 20 min with rise rate of 1.22 °C/min for the integrated system with parallel circuit. Integrated system with serial circuit shows higher HVAC heating capacity than integrated system with parallel circuit which are 5726.33 W and 3869.15 W, respectively. ANN model with back-propagation algorithm, Levenberg-Marquardt training variant, Tan-sigmoidal transfer function and 20 hidden neurons presents the accurate prediction of heating performances of the integrated system with serial and parallel circuits for battery and HVAC.


  • Open Access

    Numerical Investigations on Magnetohydrodynamic Pump Based Microchannel Cooling System for Heat Dissipating Element

    by Jae-Hyeong Seo, Mahesh Suresh Patil, Satyam Panchal, Moo-Yeon Lee

    Numerical investigations are performed on the magnetohydrodynamic (MHD) pump-based microchannel cooling system for heat dissipating element. In the present study, the MHD pump performance is evaluated considering normal current density, magnetic flux density, volumetric Lorentz force, shear stress and pump flow velocity by varying applied voltage and Hartmann number. It is found that for a low Hartmann number, the Lorentz force increases with an increase in applied voltage and Hartmann number. The velocity distribution along dimensionless width, the shear stress distribution along dimensionless width, the magnetic flux density along the dimensionless width and radial magnetic field distribution showed symmetrical behavior. The MHD pump-based microchannel cooling system performance is evaluated by considering the maximum temperature of the heat dissipating element, heat removal rate, efficiency, thermal field, flow field and Nusselt number. In addition, the influence of various nanofluids including Cu-water, TiO2-water and Al2O3-water nanofluids on heat transfer performance of MHD pump-based microchannel is evaluated. As the applied voltage increased from 0.05 V to 0.35 V at Hartmann number 1.41, the heat removal rate increased by 39.5%. The results reveal that for low Hartmann number, average Nusselt number is increasing function of applied voltage and Hartmann number. At the Hartmann number value of 3.74 and applied voltage value of 0.35 V, average Nusselt numbers were 12.3% and 15.1% higher for Cu-water nanofluid compared to TiO2-water and Al2O3-water nanofluids, respectively. The proposed magnetohydrodynamic microcooling system is effective without any moving part.


  • Open Access

    Power Generation, Efficiency and Thermal Stress of Thermoelectric Module with Leg Geometry, Material, Segmentation and Two-Stage Arrangement

    by Moo-Yeon Lee, Jae-Hyeong Seo, Ho-Seong Lee, Kunal Sandip Garud

    The objective of this study was to investigate the power generation, efficiency, and thermal stress of a thermoelectric module with leg geometry, material, segmentation, and two-stage arrangement. The effects of leg geometry, material, segmentation, and two-stage arrangement on maximum power, maximum efficiency, and maximum stress under various temperature differences and voltage load conditions were investigated. The performance parameters of the thermoelectric module were evaluated based on a numerical approach using ANSYS 19.1 commercial software. An analytical approach based on theoretical equations of the thermoelectric module was used to verify the accuracy and reliability of the numerical approach. The numerically predicted values for maximum power and maximum efficiency of the thermoelectric module were validated as ±5% and those for the maximum thermal stress of the thermoelectric module as ±7% with the corresponding calculated theoretical values. In addition, the predicted values of maximum power and maximum stress of the thermoelectric module were validated as ±2% and ±5%, respectively, with studies reported by Ma et al. and Al-Merbati et al. Of all the combinations, the single stage segmented arrangement with cylindrical leg geometry and SiGe+Bi2Te3 material was suggested as the best combination with maximum power of 0.73 W, maximum efficiency of 13.2%, and maximum thermal stress of 0.694 GPa.


  • Open Access

    Artificial Neural Network and Adaptive Neuro-Fuzzy Interface System Modelling to Predict Thermal Performances of Thermoelectric Generator for Waste Heat Recovery

    by Kunal Sandip Garud, Jae-Hyeong Seo, Chong-Pyo Cho, Moo-Yeon Lee

    The present study elaborates the suitability of the artificial neural network (ANN) and adaptive neuro-fuzzy interface system (ANFIS) to predict the thermal performances of the thermoelectric generator system for waste heat recovery. Six ANN models and seven ANFIS models are formulated by considering hot gas temperatures and voltage load conditions as the inputs to predict current, power, and thermal efficiency of the thermoelectric generator system for waste heat recovery. The ANN model with the back-propagation algorithm, the Levenberg–Marquardt variant, Tan-Sigmoidal transfer function and 25 number of hidden neurons is found to be an optimum model to accurately predict current, power and thermal efficiency. For current, power and thermal efficiency, the ANFIS model with pi-5 or gauss-5-membership function is recommended as the optimum model when the prediction accuracy is important while the ANFIS model with gbell-3-membership function is suggested as the optimum model when the prediction cost plays a crucial role along with the prediction accuracy. The proposed optimal ANN and ANFIS models present higher prediction accuracy than the coupled numerical approach.


  • Open Access

    Thermal Abuse Behavior of the LIR2450 Micro Coin Cell Battery Having Capacity of 120 mAh with Internal Short Circuit by Penetrating Element

    by Moo-Yeon Lee, Namwon Kim, Jae-Hyeong Seo, Mahesh Suresh Patil

    Internal short circuit in lithium-ion battery by penetrating element leads to exothermic behavior due to accumulated heat. In the present study, investigations are conducted on the thermal behavior of the LIR2450 micro coin cell haivng capacity of 120 mAh, with internal short circuit by penetrating element. The experimental coin cell discharge study was conducted and validated with numerical study within ±5.0%. The effect of penetrating element size, location of penetrating element, state of charge, discharge rate, short-circuit resistance, and heat transfer co-efficient on maximum coin cell temperature and heat generation rate are analyzed. The penetrating element diameters of 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, and 3.5 mm are considered. The effect of initial state of charge (SOC) is considered with 100%, 80%, 60%, and 40%. Three locations for penetrating element are considered with the center, the middle of the radius, and on the edge of the coin cell radius. The different discharge rates of 1C, 2C, 3C, and 4C are considered. The higher-penetrating element size of 3.5 mm with location at the center of the coin cell with 100% SOC showed maximum heat generation rate and maximum temperature of the coin cell. In addition, the optimum value of the dimensionless heat generation rate is obtained at dimensionless short-circuit resistance. The study provides comprehensive insights on the thermal behavior of the lithium-ion cell during thermal abuse condition with internal short circuit by penetrating element.


  • Open Access

    Numerical Study on Heat Transfer Characteristics of the 36V Electronic Control Unit System for an Electric Bicycle

    by Gihan Ekanayake, Mahesh Suresh Patil, Jae-Hyeong Seo, Moo-Yeon Lee

    The objective of this study was to numerically investigate the heat transfer characteristics of a 36V electronic control unit (ECU) system of an electric bicycle and to validate the experimental data. The temperatures of the ECU heatsink, seven metal-oxide-silicon field effect transistors (MOSFETs) and two capacitors of the 36V ECU system were numerically derived under variable operating conditions including power dissipation, thermal grease, ambient temperature and heatsink material, to analyze the heat transfer characteristics. When the thermal conductivity of the thermal grease increased from 0.01 W/m °C to 3.0 W/m° C, the temperatures of the seven MOSFETs and the two capacitors decreased by 51.245% and 3.58%, respectively. When the total power dissipation increased from 2.57 MW/m3 to 4.26 MW/m3, the temperatures of the ECU heatsink, seven MOSFETs and the two capacitors increased by 20.95%, 30.31% and 21.54%, respectively. Furthermore, increasing the ambient temperatures from 30 °C to 40 °C resulted in an increase in the temperatures of the ECU heatsink, MOSFET and capacitor by 24.75%, 9.93% and 22.04% respectively.. These numerically derived temperatures for the MOSFET and the ECU heatsink were validated with the experimental results within a range of 7.2% and 1.7%, respectively. This confirmed that the applied numerical model was valid.

  • Open Access

    Macroscopic and Microscopic Spray Characteristics of Diesel and Gasoline in a Constant Volume Chamber

    by Moo-Yeon Lee, Gee-Soo Lee, Chan-Jung Kim, Jae-Hyeong Seo, Ki-Hyun Kim

    The aim of this study is to investigate the spray characteristics of diesel and gasoline under various ambient conditions. Ambient conditions were simulated, ranging from atmospheric conditions to high pressure and temperature conditions such as those inside a combustion chamber of an internal combustion engine. Spray tip penetration and spray cross-sectional area were calculated in liquid and vapor spray development. In addition, initial spray development and end of injection near nozzle were visualized microscopically, to study spray atomization characteristics. Three injection pressures of 50 MPa, 100 MPa, and 150 MPa were tested. The ambient temperature was varied from 300 K to 950 K, and the ambient density was maintained between 1 kg/m3 and 20 kg/m3. Gasoline and diesel exhibited similar liquid penetration and spray cross-sectional area at every ambient density condition under non-evaporation. As the ambient temperature increased, liquid penetration length and spray area of both fuels’ spray were shortened and decreased by fuel evaporation near the spray boundary. However, the two fuels were characterized by different slopes in the decrement trend of spray area as the ambient temperature increased. The decrement slope trend coincided considerably with the distillation curve characteristics of the two fuels. Vapor spray boundary of gasoline and diesel was particularly similar, despite the different amount of fuel evaporation. It was assumed that the outer spray boundary of gasoline and diesel is always similar when using the same injector and injection conditions. In microscopic spray visualization, gasoline spray displayed a more unstable and asymmetric spray shape, with more dispersed and distributed fuel ligaments during initial spray development. Large amounts of fuel vapor cloud were observed near the nozzle at the end of the injection process with gasoline. Some amounts of this vapor cloud were attributed to the evaporation of residual fuel in the nozzle sac.


  • Parametric study on heat transfer characteristics of waste heat recovery heat exchanger for automotive exhaust thermoelectric generator

    by Ki. Hyun Kim, Mahesh Suresh Patil, Jae Hyeong Seo, Chan Jung Kim, Gee Soo Lee, Moo Yeon Lee

    Background/Objectives: The parametric study on heat transfer characteristics of waste heat recovery heat exchanger was carried out by varying different geometry parameters to suggest optimum model for automotive exhaust thermoelectric generator.Methods/Statistical analysis: The numerical analysis method was applied to compare the heat transfer characteristics of various heat exchanger models. For numerical analysis, various models were created using computer aided drawing considering different fin arrangements and guide plates. Commercial code ANSYS 17.0 was used to analyze the heat transfer and fluid flow behavior of various models. Mesh independency was conducted to enhance the accuracy of the results.Findings: The thermal performance analysis of waste heat recovery heat exchanger was conducted considering pressure drop and heat flux at cooling side. As the fin spaces were increased, the heat flux at cooling side increased, but pressure drop also increased.Improvements/Applications: The developed geometry can be further optimized considering other geometry parameters and efficient system could be developed for power generation using waste heat with heat recovery exchanger and the present study provides detailed numerical analysis considering pressure drop and heat flux.