Jr-Lung Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jr-Lung Lin has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Pei-Pei Hsu
Department of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 84001, Taiwan
3 shared publications - Chi-Han Chiou
ITRI South Campus, Industrial Technology Research Institute, Tainan City 70955, Taiwan
2 shared publications - Ju-Nan Kuo
Department of Automation Engineering, National Formosa University, Yunlin, Taiwan
2 shared publications - An-Yu Huang
Department of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 84001, Taiwan
1 shared publication - Chen-Hsun Weng
Medical Device Innovation Center, National Cheng Kung University, Tainan 70101, Taiwan
1 shared publication Chi-Han Chiou
Smart Microsystems Technology Center, Industrial Technology Research Institute, Tainan 709, Taiwan
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (9) , 1027
Asymmetric Flow Dynamics in a Pneumatically Actuated Polydimethylsiloxane (PDMS) Micropump: Numerical Simulation and Experimental Validation
This study presents a comprehensive numerical and experimental investigation on a pneumatically actuated polydimethylsiloxane (PDMS) micropump integrated with passive check valves (PCVs). Advanced three-dimensional (3D) fluid–structure interaction (FSI) simulations were conducted to capture the nonlinear large deformation of the membrane and elucidate the Newtonian flow dynamics. The maximum deformation calculated by the simulations was compared with the theoretical Timoshenko formula, demonstrating excellent agreement across the entire pressure range (3.0–100.0 kPa). The 3D FSI simulations revealed a considerable asymmetry in the flow dynamics between the suction and compression phases. Notably, at applied pressures exceeding 20.0 kPa, the discharge volume substantially outweighed the suction one. To characterize both the ideal and practical volumetric flow rates, curve-fitting analyses revealed that both the simulation and experimental data follow a consistent 1/3-power-law relationship with respect to the applied pressure. Experimentally, the micropump achieved a maximum volumetric flow rate of 2.6 mL/min at 70.0 kPa and 12.0 Hz. Furthermore, the micropump demonstrated a peak pumping efficiency of 56.95% at 35.0 kPa and 10.0 Hz relative to the ideal numerical baseline. By bridging idealized numerical bounds with experimental realities, this validated framework offers a robust predictive tool for optimizing flow asymmetry and pumping efficiency in advanced microfluidic systems.
- 28 August 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (9) , 1027
Open AccessAsymmetric Flow Dynamics in a Pneumatically Actuated Polydimethylsiloxane (PDMS) Micropump: Numerical Simulation and Experimental Validation
This study presents a comprehensive numerical and experimental investigation on a pneumatically actuated polydimethylsiloxane (PDMS) micropump integrated with passive check valves (PCVs). Advanced three-dimensional (3D) fluid–structure interaction (FSI) simulations were conducted to capture the nonlinear large deformation of the membrane and elucidate the Newtonian flow dynamics. The maximum deformation calculated by the simulations was compared with the theoretical Timoshenko formula, demonstrating excellent agreement across the entire pressure range (3.0–100.0 kPa). The 3D FSI simulations revealed a considerable asymmetry in the flow dynamics between the suction and compression phases. Notably, at applied pressures exceeding 20.0 kPa, the discharge volume substantially outweighed the suction one. To characterize both the ideal and practical volumetric flow rates, curve-fitting analyses revealed that both the simulation and experimental data follow a consistent 1/3-power-law relationship with respect to the applied pressure. Experimentally, the micropump achieved a maximum volumetric flow rate of 2.6 mL/min at 70.0 kPa and 12.0 Hz. Furthermore, the micropump demonstrated a peak pumping efficiency of 56.95% at 35.0 kPa and 10.0 Hz relative to the ideal numerical baseline. By bridging idealized numerical bounds with experimental realities, this validated framework offers a robust predictive tool for optimizing flow asymmetry and pumping efficiency in advanced microfluidic systems.
- Open Access
- 30 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1349
Magnetic Beads inside Droplets for Agitation and Splitting Manipulation by Utilizing a Magnetically Actuated Platform
We successfully developed a platform for the magnetic manipulation of droplets containing magnetic beads and examined the washing behaviors of the droplets, including droplet transportation, magnetic bead agitation inside droplets, and separation from parent droplets. Magnetic field gradients were produced with two layers of 6 × 1 planar coils fabricated by using printed circuit board technology. We performed theoretical analyses to understand the characteristics of the coils and successfully predicted the magnetic field and thermal temperature of a single coil. We then investigated experimentally the agitation and splitting kinetics of the magnetic beads inside droplets and experimentally observed the washing performance in different neck-shaped gaps. The performance of the washing process was evaluated by measuring both the particle loss ratio and the optical density. The findings of this work will be used to design a magnetic-actuated droplet platform, which will separate magnetic beads from their parent droplets and enhance washing performance. We hope that this study will provide digital microfluidics for application in point-of-care testing. The developed microchip will be of great benefit for genetic analysis and infectious disease detection in the future.
- 30 June 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1349
Open AccessMagnetic Beads inside Droplets for Agitation and Splitting Manipulation by Utilizing a Magnetically Actuated Platform
We successfully developed a platform for the magnetic manipulation of droplets containing magnetic beads and examined the washing behaviors of the droplets, including droplet transportation, magnetic bead agitation inside droplets, and separation from parent droplets. Magnetic field gradients were produced with two layers of 6 × 1 planar coils fabricated by using printed circuit board technology. We performed theoretical analyses to understand the characteristics of the coils and successfully predicted the magnetic field and thermal temperature of a single coil. We then investigated experimentally the agitation and splitting kinetics of the magnetic beads inside droplets and experimentally observed the washing performance in different neck-shaped gaps. The performance of the washing process was evaluated by measuring both the particle loss ratio and the optical density. The findings of this work will be used to design a magnetic-actuated droplet platform, which will separate magnetic beads from their parent droplets and enhance washing performance. We hope that this study will provide digital microfluidics for application in point-of-care testing. The developed microchip will be of great benefit for genetic analysis and infectious disease detection in the future.
- Open Access
- 28 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1622
Characterization of a Droplet Containing the Clustered Magnetic Beads Manipulation by Magnetically Actuated Chips
A magnetically actuated chip was successfully developed in this study to perform the purpose of transportation for a droplet containing clustered magnetic beads. The magnetic field gradient is generated by the chip of the two-layer 4 × 4 array micro-coils, which was commercially fabricated by printing circuit board (PCB) technology. A numerical model was first established to investigate the magnetic field and thermal field for such a micro-coil. Consequently, the numerical simulations were in reasonable agreement with the experimental results. Moreover, a theoretical analysis was derived to predict the dynamic behaviors of the droplets. This analysis will offer the optimal operation for such a magnetically actuated chip. This study aims to successfully implement the concept of “digital microfluidics” in “point-of-care testing” (POCT). In the future, the micro-coil chip will be of substantial benefit to genetic analysis and infectious disease detection.
- 28 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1622
Open AccessCharacterization of a Droplet Containing the Clustered Magnetic Beads Manipulation by Magnetically Actuated Chips
A magnetically actuated chip was successfully developed in this study to perform the purpose of transportation for a droplet containing clustered magnetic beads. The magnetic field gradient is generated by the chip of the two-layer 4 × 4 array micro-coils, which was commercially fabricated by printing circuit board (PCB) technology. A numerical model was first established to investigate the magnetic field and thermal field for such a micro-coil. Consequently, the numerical simulations were in reasonable agreement with the experimental results. Moreover, a theoretical analysis was derived to predict the dynamic behaviors of the droplets. This analysis will offer the optimal operation for such a magnetically actuated chip. This study aims to successfully implement the concept of “digital microfluidics” in “point-of-care testing” (POCT). In the future, the micro-coil chip will be of substantial benefit to genetic analysis and infectious disease detection.
- Open Access
Paper-Based Microfluidics Perform Mixing Effects by Utilizing Planar Constricted–Expanded Structures to Enhance Chaotic Advection
This study aimed to design and fabricate planar constricted–expanded structures that are integrated into paper-based channels in order to enhance their chaotic advection and improve their mixing performance. Chromatography papers were used to print paper-based microfluidics using a solid-wax printer. Three different constricted–expanded structures—i.e., zigzag, crossed, and curved channels—were designed in order to evaluate their mixing performance in comparison with that of straight channels. A numerical simulation was performed in order to investigate the mixing mechanism, and to examine the ways in which the planar constricted–expanded structures affected the flow patterns. The experimental and numerical results indicated that the proposed structures can successfully mix confluents. The experimental results revealed that the mixing indices (σ) rose from the initial 20.1% (unmixed) to 34.5%, 84.3%, 87.3%, and 92.4% for the straight, zigzag, curved, and cross-shaped channels, respectively. In addition, the numerical calculations showed a reasonable agreement with the experimental results, with a variation in the range of 1.0–11.0%. In future, we hope that the proposed passive paper-based mixers will be a crucial component in the application of paper-based microfluidic devices.
Open AccessPaper-Based Microfluidics Perform Mixing Effects by Utilizing Planar Constricted–Expanded Structures to Enhance Chaotic Advection
This study aimed to design and fabricate planar constricted–expanded structures that are integrated into paper-based channels in order to enhance their chaotic advection and improve their mixing performance. Chromatography papers were used to print paper-based microfluidics using a solid-wax printer. Three different constricted–expanded structures—i.e., zigzag, crossed, and curved channels—were designed in order to evaluate their mixing performance in comparison with that of straight channels. A numerical simulation was performed in order to investigate the mixing mechanism, and to examine the ways in which the planar constricted–expanded structures affected the flow patterns. The experimental and numerical results indicated that the proposed structures can successfully mix confluents. The experimental results revealed that the mixing indices (σ) rose from the initial 20.1% (unmixed) to 34.5%, 84.3%, 87.3%, and 92.4% for the straight, zigzag, curved, and cross-shaped channels, respectively. In addition, the numerical calculations showed a reasonable agreement with the experimental results, with a variation in the range of 1.0–11.0%. In future, we hope that the proposed passive paper-based mixers will be a crucial component in the application of paper-based microfluidic devices.
- Open Access
- 23 December 2021
- Published by MDPI AG in Micromachines
- Vol. 13 (1) , 16
Design and Fabrication of Pneumatically Actuated Valveless Pumps
In this study, a valveless pump was successfully designed and fabricated for the purpose of medium transportation. Different from traditional pumps, the newly designed pump utilizes an actuated or a deflected membrane, and it serves as the function of a check valve at the same time. For achieving the valveless property, an inlet or outlet port positioned in an upper- or lower-layer thin membrane was designed to be connected to an entrance or exit channel. Theoretical analysis and numerical simulation were conducted simultaneously to investigate the large deformation characteristics of the membranes and to determine the proper location of the inlet or outlet port on the proposed pump. Then, the valveless pump was fabricated on the basis of the proposed design. In the experiment, the maximum flow rate of the proposed pump exceeded 12.47 mL/min at a driving frequency of 5.0 Hz and driving pressure of 68.95 kPa.
- 23 December 2021
- Published by MDPI AG in Micromachines
- Vol. 13 (1) , 16
Open AccessDesign and Fabrication of Pneumatically Actuated Valveless Pumps
In this study, a valveless pump was successfully designed and fabricated for the purpose of medium transportation. Different from traditional pumps, the newly designed pump utilizes an actuated or a deflected membrane, and it serves as the function of a check valve at the same time. For achieving the valveless property, an inlet or outlet port positioned in an upper- or lower-layer thin membrane was designed to be connected to an entrance or exit channel. Theoretical analysis and numerical simulation were conducted simultaneously to investigate the large deformation characteristics of the membranes and to determine the proper location of the inlet or outlet port on the proposed pump. Then, the valveless pump was fabricated on the basis of the proposed design. In the experiment, the maximum flow rate of the proposed pump exceeded 12.47 mL/min at a driving frequency of 5.0 Hz and driving pressure of 68.95 kPa.
- Open Access
- 21 December 2017
- Published by MDPI AG in Micromachines
- Vol. 9 (1) , 1
Optimization of Micropump Performance Utilizing a Single Membrane with an Active Check Valve
In this study, we successfully designed and tested a new micropump that utilizes an active check valve and bottom-protruding structure to achieve sample transportation. We performed theoretical analyses and numerical simulations to determine the optimal location of the active check valve. We also experimentally analyzed variations in the generated flow rate with respect to the pneumatic frequencies, actuated air pressures, and locations of the active check valve. The experimental results indicate the optimum air pressure, driving frequency, and location of the active check valve to be 68.9 kPa, 26.0 Hz, and 2.0 mm, respectively. We obtained a maximum pumping rate of 488 μL/min and a maximum pumping efficiency of 35.4%. The proposed micropump could perform a crucial function in the transportation of microfluids and could be incorporated into micro total analysis systems.
- 21 December 2017
- Published by MDPI AG in Micromachines
- Vol. 9 (1) , 1
Open AccessOptimization of Micropump Performance Utilizing a Single Membrane with an Active Check Valve
In this study, we successfully designed and tested a new micropump that utilizes an active check valve and bottom-protruding structure to achieve sample transportation. We performed theoretical analyses and numerical simulations to determine the optimal location of the active check valve. We also experimentally analyzed variations in the generated flow rate with respect to the pneumatic frequencies, actuated air pressures, and locations of the active check valve. The experimental results indicate the optimum air pressure, driving frequency, and location of the active check valve to be 68.9 kPa, 26.0 Hz, and 2.0 mm, respectively. We obtained a maximum pumping rate of 488 μL/min and a maximum pumping efficiency of 35.4%. The proposed micropump could perform a crucial function in the transportation of microfluids and could be incorporated into micro total analysis systems.
- 18 April 2016
- Published by IOP Publishing in Applied Physics Express
- Vol. 9 (5) , 057001
Novel electrodeless-dielectrophoresis device for nanoparticle trapping using three-dimensional inverted-pyramid arrays
A novel electrodeless-dielectrophoresis (EDEP) device incorporating three-dimensional (3D) inverted-pyramid arrays is proposed for the trapping and separation of nanoparticles. The electrokinetic phenomena in the proposed device are investigated both numerically and experimentally. The results reveal that the pyramid structures induce a 3D squeezed electric field, which allows particle trapping with a lower driving voltage than that required in traditional two-dimensional (2D) EDEP devices. Overall, the proposed EDEP device provides a mass-producible solution for nanoparticle-trapping applications and overcomes the Poisson statistical limit inherent in 2D nanogap-based EDEP devices with smaller (pL) sample volumes.
- 18 April 2016
- Published by IOP Publishing in Applied Physics Express
- Vol. 9 (5) , 057001
Novel electrodeless-dielectrophoresis device for nanoparticle trapping using three-dimensional inverted-pyramid arrays
A novel electrodeless-dielectrophoresis (EDEP) device incorporating three-dimensional (3D) inverted-pyramid arrays is proposed for the trapping and separation of nanoparticles. The electrokinetic phenomena in the proposed device are investigated both numerically and experimentally. The results reveal that the pyramid structures induce a 3D squeezed electric field, which allows particle trapping with a lower driving voltage than that required in traditional two-dimensional (2D) EDEP devices. Overall, the proposed EDEP device provides a mass-producible solution for nanoparticle-trapping applications and overcomes the Poisson statistical limit inherent in 2D nanogap-based EDEP devices with smaller (pL) sample volumes.
- Open Access
- 29 January 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (2) , 216-229
Deformation Analysis of a Pneumatically-Activated Polydimethylsiloxane (PDMS) Membrane and Potential Micro-Pump Applications
This study presents a double-side diaphragm peristaltic pump for efficient medium transport without the unwanted backflow and the lagging effect of a diaphragm. A theoretical model was derived to predict the important parameter of the micropump, i.e., the motion of the valves at large deformations, for a variety of air pressures. Accordingly, we proposed an easy and robust design to fabricate a Polydimethylsiloxane (PDMS)-based micropump. The theoretical model agrees with a numerical model and experimental data for the deformations of the PDMS membrane. Furthermore, variations of the generated flow rate, including pneumatic frequencies, actuated air pressures, and operation modes were evaluated experimentally for the proposed micropumps. In future, the theoretical equation could provide the optimal parameters for the scientists working on the fabrication of the diaphragm peristaltic pump for applications of cell-culture.
- 29 January 2015
- Published by MDPI AG in Micromachines
- Vol. 6 (2) , 216-229
Open AccessDeformation Analysis of a Pneumatically-Activated Polydimethylsiloxane (PDMS) Membrane and Potential Micro-Pump Applications
This study presents a double-side diaphragm peristaltic pump for efficient medium transport without the unwanted backflow and the lagging effect of a diaphragm. A theoretical model was derived to predict the important parameter of the micropump, i.e., the motion of the valves at large deformations, for a variety of air pressures. Accordingly, we proposed an easy and robust design to fabricate a Polydimethylsiloxane (PDMS)-based micropump. The theoretical model agrees with a numerical model and experimental data for the deformations of the PDMS membrane. Furthermore, variations of the generated flow rate, including pneumatic frequencies, actuated air pressures, and operation modes were evaluated experimentally for the proposed micropumps. In future, the theoretical equation could provide the optimal parameters for the scientists working on the fabrication of the diaphragm peristaltic pump for applications of cell-culture.
- Open Access
Characterization of Microparticle Separation Utilizing Electrokinesis within an Electrodeless Dielectrophoresis Chip
This study demonstrated the feasibility of utilizing electrokinesis in an electrodeless dielectrophoresis chip to separate and concentrate microparticles such as biosamples. Numerical simulations and experimental observations were facilitated to investigate the phenomena of electrokinetics, i.e., electroosmosis, dielectrophoresis, and electrothermosis. Moreover, the proposed operating mode can be used to simultaneously convey microparticles through a microfluidic device by using electroosmotic flow, eliminating the need for an additional micropump. These results not only revealed that the directions of fluids could be controlled with a forward/backward electroosmotic flow but also categorized the optimum separating parameters for various microparticle sizes (0.5, 1.0 and 2.0 μm). Separation of microparticles can be achieved by tuning driving frequencies at a specific electric potential (90 Vpp·cm−1). Certainly, the device can be designed as a single automated device that carries out multiple functions such as transportation, separation, and detection for the realization of the envisioned Lab-on-a-Chip idea.
Open AccessCharacterization of Microparticle Separation Utilizing Electrokinesis within an Electrodeless Dielectrophoresis Chip
This study demonstrated the feasibility of utilizing electrokinesis in an electrodeless dielectrophoresis chip to separate and concentrate microparticles such as biosamples. Numerical simulations and experimental observations were facilitated to investigate the phenomena of electrokinetics, i.e., electroosmosis, dielectrophoresis, and electrothermosis. Moreover, the proposed operating mode can be used to simultaneously convey microparticles through a microfluidic device by using electroosmotic flow, eliminating the need for an additional micropump. These results not only revealed that the directions of fluids could be controlled with a forward/backward electroosmotic flow but also categorized the optimum separating parameters for various microparticle sizes (0.5, 1.0 and 2.0 μm). Separation of microparticles can be achieved by tuning driving frequencies at a specific electric potential (90 Vpp·cm−1). Certainly, the device can be designed as a single automated device that carries out multiple functions such as transportation, separation, and detection for the realization of the envisioned Lab-on-a-Chip idea.
- Open Access
Development of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
This study reports an integrated microfluidic perfusion cell culture system consisting of a microfluidic cell culture chip, and an indium tin oxide (ITO) glass-based microheater chip for micro-scale perfusion cell culture, and its real-time microscopic observation. The system features in maintaining both uniform, and stable chemical or thermal environments, and providing a backflow-free medium pumping, and a precise thermal control functions. In this work, the performance of the medium pumping scheme, and the ITO glass microheater were experimentally evaluated. Results show that the medium delivery mechanism was able to provide pumping rates ranging from 15.4 to 120.0 μL·min−1. In addition, numerical simulation and experimental evaluation were conducted to verify that the ITO glass microheater was capable of providing a spatially uniform thermal environment, and precise temperature control with a mild variation of ±0.3 °C. Furthermore, a perfusion cell culture was successfully demonstrated, showing the cultured cells were kept at high cell viability of 95 ± 2%. In the process, the cultured chondrocytes can be clearly visualized microscopically. As a whole, the proposed cell culture system has paved an alternative route to carry out real-time microscopic observation of biological cells in a simple, user-friendly, and low cost manner.
Open AccessDevelopment of an Integrated Microfluidic Perfusion Cell Culture System for Real-Time Microscopic Observation of Biological Cells
This study reports an integrated microfluidic perfusion cell culture system consisting of a microfluidic cell culture chip, and an indium tin oxide (ITO) glass-based microheater chip for micro-scale perfusion cell culture, and its real-time microscopic observation. The system features in maintaining both uniform, and stable chemical or thermal environments, and providing a backflow-free medium pumping, and a precise thermal control functions. In this work, the performance of the medium pumping scheme, and the ITO glass microheater were experimentally evaluated. Results show that the medium delivery mechanism was able to provide pumping rates ranging from 15.4 to 120.0 μL·min−1. In addition, numerical simulation and experimental evaluation were conducted to verify that the ITO glass microheater was capable of providing a spatially uniform thermal environment, and precise temperature control with a mild variation of ±0.3 °C. Furthermore, a perfusion cell culture was successfully demonstrated, showing the cultured cells were kept at high cell viability of 95 ± 2%. In the process, the cultured chondrocytes can be clearly visualized microscopically. As a whole, the proposed cell culture system has paved an alternative route to carry out real-time microscopic observation of biological cells in a simple, user-friendly, and low cost manner.