Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Olympia Zogou has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of Electrical and Thermal Storage in a High School Building in Central Greece

    by Elias Roumpakias, Olympia Zogou, Antiopi-Malvina Stamatellou

    Nearly zero-emission buildings (nZEBs) are increasingly being constructed in Europe. There are also incentives to refurbish older buildings and transform them into nZEBs. However, permission is not always granted for their connection to the grid to infuse surplus photovoltaic electricity due to the grid being overloaded with a large number of renewables. In this study, the case of a refurbished school building in Central Greece is examined. After refurbishing it, a significant amount of photovoltaic electricity surplus is observed during the summer and neutral months, which cannot be exported to the grid. The absence of an adequate battery storage capacity resulted in the rejection of an application for exporting the school’s surplus to the network and the photovoltaic installation staying idle. An alternative approach is proposed in this work, involving a shift in the export of the photovoltaic electricity surplus to the evening hours, in order for the school to be granted permission to export it to the network. To this end, an optimal battery storage size is sought by employing a building energy system simulation. The mode of operation of the battery designed for this application is set to discharge daily, in order to export the electricity surplus in the afternoon hours to the evening hours, when it is favorable for the network. Additionally, the optimal size of the thermal energy storage of the heating system is studied to further improve its energy efficiency. Our battery and storage tank size optimization study shows that a significant battery capacity is required, with 12 kWh/kWp photovoltaic panels being recommended for installation. The ever-decreasing cost of battery installations results in the net present value (NPV) of the additional investment for the battery installation becoming positive. The solution proposed forms an alternative path to further increase the penetration of renewables in saturated networks in Greece by optimizing battery storage capacity.


  • Open Access

    Energy Cost Assessment and Optimization of Post-COVID-19 Building Ventilation Strategies

    by Antiopi-Malvina Stamatellou, Olympia Zogou, Anastassios Stamatelos

    The advent of the COVID-19 pandemic puts stress on the requirements of indoor air quality. Significant improvements in the design of building ventilation systems have become necessary, as this allows for the supply of higher quantities of outdoor air in buildings. Additional capital investment is necessary for increases in the size of ventilation fans and ducts, as well as for the installation of efficient air-to-air recuperators, to recover the enthalpy of the rejected air. To address the increased operation costs, smart strategies are necessary to make rational use of the ventilation system. The required modifications are studied in the example of an 18-zone office building located in Volos, Greece. The building’s energy performance is studied by means of transient simulation. Operation of the ground-coupled heat pump, the upgraded ventilation system and the high-performance recuperators and filters’ interactions is presented in detail at various time scales. The results show the effect of increased ventilation requirements of new and renovated office and commercial buildings in the post-COVID era. The added capital equipment and operation costs must be met with a strong and sustained engineering effort. Especially in the case of nZEB buildings, the protection of public health must be attained, with reduction of the added electricity consumption penalties, in order to keep the nZEB character of the building.


  • Open Access

    Energy Analysis of a NZEB Office Building with Rooftop PV Installation: Exploitation of the Employees’ Electric Vehicles Battery Storage

    by George Stamatellos, Olympia Zogou, Anastassios Stamatelos

    Near zero energy buildings are increasing worldwide, exploiting low-carbon technologies in heating and electricity self-production. Commercial buildings are increasingly considered as candidates for the installation of smart micro-grids, which may profit from the added storage capacity of the batteries of employees electric vehicles, stationed during daytime in their charging lots. Smart exploitation of the interaction of these electricity sources and sinks may prove essential to address the complex electricity network demand patterns in today’s fast changing energy mixture. The interaction of an efficient office building’s energy system with a big rooftop photovoltaic installation and the aggregate storage capacity of 40 electric cars that are connected in the building’s charging lots is studied by means of transient simulation in TRNSYS environment. The 18-zone building’s heating, ventilation, and air conditioning system, the cars’ batteries, and photovoltaic systems’ interactions are analyzed on a monthly, seasonal, and hourly basis, against the respective demand curves of the Greek network. The results suggest that the specific system’s size may profitably support the operation of a smart micro-grid. The total annual electricity consumption of the building is computed to reach 112,000 kWh, or 20 kWh/m2y. The annual electricity needs of the 40 electric cars, amounting to 101,000 kWh, can be fully met with 30% of the photovoltaic electricity production. Thus, the building becomes a net exporter of electricity to the network, with maximum exported electricity occurring daily between 12:00 and 14:00, which is favorable to meeting the demand curve. Thus, the establishment of smart micro-grids in commercial buildings with large rooftop photovoltaic panels’ capacity and a significant number of electric cars in the employees’ car fleet is quite effective in this direction.


  • Open Access

    Interaction of a House’s Rooftop PV System with an Electric Vehicle’s Battery Storage and Air Source Heat Pump

    by George Stamatellos, Olympia Zogou, Anastassios Stamatelos

    Understanding the implications of introducing increasing shares of low-carbon technologies such as heat pumps and electric vehicles on the electricity network demand patterns is essential in today’s fast changing energy mixture. Application of heat pumps for heating and cooling, combined with the rooftop installation of photovoltaic panels, is already considered as a convenient retrofitting strategy towards building electrification. This may further profit from the parallel, rapid electrification of the automotive powertrain, as demonstrated in the present study. Exploitation of the combined battery storage of the house owners’ electric car(s) may help cover, to a significant degree, the building’s and cars’ electricity needs. To this end, an efficient single family house’s energy system with an optimized rooftop PV installation, heat pump heating and cooling, and two high efficiency electric cars is studied by transient simulation. The use of TRNSYS simulation environment makes clear the interaction of the house’s heating, ventilation, and air conditioning (HVAC) system, the house’s and cars’ batteries, and the rooftop PV system in transient operation. The building’s and EV’s energy performance on a daily, monthly, and seasonal level is compared with the respective demand curves and energy sources of the Greek electricity network. The specific design of the house’s energy system makes it a net exporter of electricity to the grid, to an annual amount of 5000 kWh. On the other hand, electricity imports are slightly exceeding 400 kWh and limited to the first two months of the year. In addition to the self-sufficiency of the household, the impact to the electricity grid becomes favorable due to the phase shift of the electricity export towards the late afternoon hours, thus assisting the evening ramp-up and adding to the grid’s stability and resilience. Based on the results of this study, the possibility of combining the financial incentives for the purchase of an EV with those for the installation of rooftop PV in the owners’ house is very promising and worth considering, due to the demonstrated synergy of electrical storage with the rooftop photovoltaic installations.


  • Open Access

    Energy Performance Optimization of a House with Grid-Connected Rooftop PV Installation and Air Source Heat Pump

    by George Stamatellos, Olympia Zogou, Anastassios Stamatelos

    The use of air source heat pump systems for space heating and cooling is a convenient retrofitting strategy for reducing building energy costs. This can be combined with the rooftop installation of photovoltaic panels, which can cover, to a significant degree—or even significantly exceed the building’s electricity needs, moving towards the zero energy building concept. Alternatively, increased capacity for rooftop photovoltaic (PV) installation may support the ongoing process of transforming the Greek power system away from the reliance on fossil fuels to potentially become one of the leaders of the energy transition in Europe by 2030. Standard building energy simulation tools allow good assessment of the Heating, Ventilation and Air Conditioning (HVAC) and PV systems’ interactions in transient operation. Further, their use enables the rational sizing and selection of the type of panels type for the rooftop PV installation to maximize the return on investment. The annual performance of a three-zone residential building in Volos, Greece, with an air-to-water heat pump HVAC system and a rooftop PV installation, are simulated in a TRNSYS environment. The simulation results are employed to assess the expected building energy performance with a high performance, inverter driven heat pump with scroll compressor and high efficiency rooftop PV panels. Further, the objective functions are developed for the optimization of the installed PV panels’ area and tilt angle, based on alternative electricity pricing and subsidies. The methodology presented can be adapted to optimize system design parameters for variable electricity tariffs and improve net metering policies.


  • Open Access

    A Three-Zone Scavenging Model for Large Two-Stroke Uniflow Marine Engines Using Results from CFD Scavenging Simulations

    by Michael I. Foteinos, Alexandros Papazoglou, Nikolaos P. Kyrtatos, Anastassios Stamatelos, Olympia Zogou, Antiopi-Malvina Stamatellou

    The introduction of modern aftertreatment systems in marine diesel engines call for accurate prediction of exhaust gas temperature, since it significantly affects the performance of the aftertreatment system. The scavenging process establishes the initial conditions for combustion, directly affecting exhaust gas temperature, fuel economy, and emissions. In this paper, a semi-empirical zero-dimensional three zone scavenging model applicable to two-stroke uniflow scavenged diesel engines is updated using the results of CFD (computational fluid dynamics) simulations. In this 0-D model, the engine cylinders are divided in three zones (thermodynamic control volumes) namely, the pure air zone, mixing zone, and pure exhaust gas zone. The entrainment of air and exhaust gas in the mixing zone is specified by time varying mixing coefficients. The mixing coefficients were updated using results from CFD simulations based on the geometry of a modern 50 cm bore large two-stroke marine diesel engine. This increased the model’s accuracy by taking into account 2-D fluid dynamics phenomena in the cylinder ports and exhaust valve. Thus, the effect of engine load, inlet port swirl angle and partial covering of inlet ports on engine scavenging were investigated. The three-zone model was then updated and the findings of CFD simulations were reflected accordingly in the updated mixing coefficients of the scavenging model.


  • Correlation of actual efficiency of photovoltaic panels with air mass

    by Elias Roumpakias, Olympia Zogou, Anastassios Stamatelos


  • Open Access

    Diagnosis and Reduction of Electricity Consumption Exceedance in Public University Buildings

    by Olympia Zogou, Tassos Stamatelos

    Higher education costs per graduating student are globally increasing to unsustainable levels, taking into account the worldwide economy problems. Electricity consumption is an essential part of university building operation costs. Thus, many universities struggle to reduce them. To succeed in the reduction of electricity consumption in public buildings, it is essential to detect, identify and classify different kinds of consumption exceedance modes in the electricity consumption time series as early as possible. Intelligent diagnosis and prognosis has already become an important field of interest in engineering. This paper presents a diagnosis methodology that we developed and applied in the University of Thessaly, aiming to find cases of unnecessary high consumption. The methodology is based on the analysis of hourly electricity consumption data from seven university building complexes with separate medium voltage substations. The follow-up measures adopted are also presented, along with the overall effect on the evolution of electricity consumption.


  • Open Access

    Analysis of Data From Ambient PM10 Concentration Monitoring in Volos in the Period 2005-2010

    by Zogou O., A. Stamatelos

    This paper presents the results of a monitoring campaign for ambient PM10 concentrations in Volos, Greece in the period 2005-2010. The aim is to give an overview of the evolution of particulate pollution, discuss effects of the micro-climate and demonstrate that PM10 monitoring may be carried out with low-cost measurement instruments at a community level. Statistical processing of the 2009-2010 measurement data indicates a negative correlation of PM10 with ambient air temperature and a positive correlation with relative humidity. Low PM10 concentrations are associated with E to SE winds and high concentrations with NW to N winds. Daily variation of particulate matter concentrations follows well established patterns with peaks at 09:00-10:00 and 23:00-24:00. The operation of an expanded PM10 monitoring network is under way.