Mehmet Anil Kizilaslan
Mehmet Anil Kizilaslan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ender Demirel
Eskişehir Osmangazi Üniversitesi
7 shared publications - Mustafa M. Aral
Georgia Institute of Technology, School of Civil and Environmental Engineering, Atlanta, GA 30332, USA
3 shared publications - Adnan Tolga Kurumus
Eskişehir Osmangazi Üniversitesi
2 shared publications Elif Deniz Atlas
Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi Pamukkale University Journal of Engineering Sciences
1 shared publication- Elif Deniz Atlas
Dept. of Civil Engineering Eskisehir Osmangazi University 26480 Eskisehir Turkey
1 shared publication - Huseyin Yaban
Dept. of Civil Engineering Eskisehir Osmangazi University 26480 Eskisehir Turkey
1 shared publication
Latest Publications
- Open Access
- 29 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 331
Integrating Long-Term Climate Data into Sponge City Design: A Case Study of the North Aegean and Marmara Regions
Climate change is altering hydrological regimes across the North Aegean and Marmara regions of Türkiye, with increasing relevance for both drought occurrence and flood generation. This study examines long-term variability in temperature, precipitation, and evaporation using meteorological observations over a long time series and relates these changes to urban water management issues. Daily records from 12 meteorological stations, with data availability varying by station and extending back to 1926, were analysed using the non-parametric Mann–Kendall trend test and Sen’s slope estimator. The results indicate statistically significant warming trends across all stations, with several locations recording daily maximum temperatures exceeding 44 °C. Precipitation trends exhibit pronounced spatial heterogeneity: while most stations show decreasing long-term tendencies, others display unchanging or non-significant trends. Nevertheless, extreme daily rainfall events exceeding 200 mm are observed at multiple coastal and island stations, indicating a tendency toward high-intensity precipitation. Evaporation trends also vary across the region, with increasing rates at stations such as Tekirdağ and Çanakkale and decreasing trends at Bandırma and Yalova, reflecting the influence of local atmospheric conditions. Taken together, these findings point to a coupled risk of intensified flooding during short-duration rainfall events and increasing water stress during warm and dry periods. Such conditions challenge the effectiveness of conventional grey infrastructure. The results are therefore interpreted within the framework of the Sponge City approach, which emphasizes permeable surfaces, decentralized storage, infiltration, and the integration of green and blue infrastructure. By linking long-term hydroclimatic trends with urban design considerations, this study provides a quantitative basis for informing adaptive urban water management and planning strategies in Mediterranean-type climate regions.
- 29 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 331
Open AccessIntegrating Long-Term Climate Data into Sponge City Design: A Case Study of the North Aegean and Marmara Regions
Climate change is altering hydrological regimes across the North Aegean and Marmara regions of Türkiye, with increasing relevance for both drought occurrence and flood generation. This study examines long-term variability in temperature, precipitation, and evaporation using meteorological observations over a long time series and relates these changes to urban water management issues. Daily records from 12 meteorological stations, with data availability varying by station and extending back to 1926, were analysed using the non-parametric Mann–Kendall trend test and Sen’s slope estimator. The results indicate statistically significant warming trends across all stations, with several locations recording daily maximum temperatures exceeding 44 °C. Precipitation trends exhibit pronounced spatial heterogeneity: while most stations show decreasing long-term tendencies, others display unchanging or non-significant trends. Nevertheless, extreme daily rainfall events exceeding 200 mm are observed at multiple coastal and island stations, indicating a tendency toward high-intensity precipitation. Evaporation trends also vary across the region, with increasing rates at stations such as Tekirdağ and Çanakkale and decreasing trends at Bandırma and Yalova, reflecting the influence of local atmospheric conditions. Taken together, these findings point to a coupled risk of intensified flooding during short-duration rainfall events and increasing water stress during warm and dry periods. Such conditions challenge the effectiveness of conventional grey infrastructure. The results are therefore interpreted within the framework of the Sponge City approach, which emphasizes permeable surfaces, decentralized storage, infiltration, and the integration of green and blue infrastructure. By linking long-term hydroclimatic trends with urban design considerations, this study provides a quantitative basis for informing adaptive urban water management and planning strategies in Mediterranean-type climate regions.
- 22 December 2024
- Published by Eskisehir Osmangazi Universitesi Muhendislik ve Mimarlik Fakultesi Dergisi in Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi
- Vol. 32 (3) , 1517-1525
ÇANAKKALE ONSEKİZ MART ÜNİVERSİTESİ TERZİOĞLU YERLEŞKESİNE SÜNGER ŞEHİR KONSEPTİ UYGULANMA POTANSİYELİNİN ARAŞTIRILMASI
Çanakkale Onsekiz Mart Üniversitesi Terzioğlu Kampüsü'nde gerçekleştirilen bu çalışma, kampüs alanında Sünger Şehir konseptinin uygulanabilirliğini araştırmayı amaçlamaktadır. Çalışma kapsamında mevcut duruma yönelik saha araştırmaları yapılmış ve coğrafi bilgi sistemi ortamı kullanılarak sayısal veriler elde edilmiştir. Elde edilen bulgulara göre, mevcut durumda yapılacak değişiklikler ile yerleşkenin sünger şehir konseptine yaklaştırılması mümkündür. Bu değişiklikler arasında yeşil çatı uygulamaları, geçirimsiz yüzeylerin geçirgen hale getirilmesi ve mevcut yağmur suyu drenaj sisteminin iyileştirilmesi yer almaktadır. Ayrıca, kampüs içinde yağmur bahçeleri ve yağmur suyu biriktirme haznelerinin inşa edilmesi önerilmiştir. Bu uygulamaların hayata geçirilmesi, kampüsün su kaynaklarını daha verimli kullanmasını sağlayarak çevresel sürdürülebilirliği artıracaktır. Çalışma sonucunda, Sünger Şehir konseptinin kampüs içerisinde uygulanmasının mümkün olduğu ve belirlenen alanlarda yapılacak iyileştirmelerin bu süreci destekleyeceği tespit edilmiştir. Bu tür yeşil uygulamaların, kampüsün ekolojik ayak izini azaltacağı, yağmur suyunu etkili bir şekilde biriktireceği ve iklim değişikliği ile mücadelede önemli bir rol oynayacağı sonucuna varılmıştır.
- 22 December 2024
- Published by Eskisehir Osmangazi Universitesi Muhendislik ve Mimarlik Fakultesi Dergisi in Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi
- Vol. 32 (3) , 1517-1525
ÇANAKKALE ONSEKİZ MART ÜNİVERSİTESİ TERZİOĞLU YERLEŞKESİNE SÜNGER ŞEHİR KONSEPTİ UYGULANMA POTANSİYELİNİN ARAŞTIRILMASI
Çanakkale Onsekiz Mart Üniversitesi Terzioğlu Kampüsü'nde gerçekleştirilen bu çalışma, kampüs alanında Sünger Şehir konseptinin uygulanabilirliğini araştırmayı amaçlamaktadır. Çalışma kapsamında mevcut duruma yönelik saha araştırmaları yapılmış ve coğrafi bilgi sistemi ortamı kullanılarak sayısal veriler elde edilmiştir. Elde edilen bulgulara göre, mevcut durumda yapılacak değişiklikler ile yerleşkenin sünger şehir konseptine yaklaştırılması mümkündür. Bu değişiklikler arasında yeşil çatı uygulamaları, geçirimsiz yüzeylerin geçirgen hale getirilmesi ve mevcut yağmur suyu drenaj sisteminin iyileştirilmesi yer almaktadır. Ayrıca, kampüs içinde yağmur bahçeleri ve yağmur suyu biriktirme haznelerinin inşa edilmesi önerilmiştir. Bu uygulamaların hayata geçirilmesi, kampüsün su kaynaklarını daha verimli kullanmasını sağlayarak çevresel sürdürülebilirliği artıracaktır. Çalışma sonucunda, Sünger Şehir konseptinin kampüs içerisinde uygulanmasının mümkün olduğu ve belirlenen alanlarda yapılacak iyileştirmelerin bu süreci destekleyeceği tespit edilmiştir. Bu tür yeşil uygulamaların, kampüsün ekolojik ayak izini azaltacağı, yağmur suyunu etkili bir şekilde biriktireceği ve iklim değişikliği ile mücadelede önemli bir rol oynayacağı sonucuna varılmıştır.
- Open Access
- 5 September 2024
- Published by Springer Nature in Research Square
Investigation of the hydraulic behavior of the Kemerdere Aqueduct in the city of Troy
Roman water structures have always attracted the attention of researchers. This study investigates the hydraulic behavior of the Kemerdere Aqueduct, an ancient Roman structure located in the city of Troy, using Computational Fluid Dynamic simulations. With Large Eddy Simulation analyses it is aim to reveal the engineering significance of the open channel of the aqueduct, whose flow direction was changed after an earthquake in antiquity. By analyzing the flow rates and water supply capabilities of the aqueduct, the research demonstrates its efficiency in providing water to urban populations. The study reveals that the Kemerdere Aqueduct could supply water to approximately 8,500 to 15,000 people daily, accounting for losses due to leakage and other inefficiencies. This highlights the advanced engineering skills of the Romans and their ability to manage water resources effectively. The findings emphasize the importance of historical technologies in addressing contemporary water management challenges and underscore the significance of preserving ancient engineering marvels. By reconstructing and evaluating the aqueduct's operation, the study contributes to a deeper understanding of Roman water management practices and their enduring relevance. The meticulous analysis of the Kemerdere Aqueduct enhances our appreciation of Roman engineering ingenuity.
- 5 September 2024
- Published by Springer Nature in Research Square
Open AccessInvestigation of the hydraulic behavior of the Kemerdere Aqueduct in the city of Troy
Roman water structures have always attracted the attention of researchers. This study investigates the hydraulic behavior of the Kemerdere Aqueduct, an ancient Roman structure located in the city of Troy, using Computational Fluid Dynamic simulations. With Large Eddy Simulation analyses it is aim to reveal the engineering significance of the open channel of the aqueduct, whose flow direction was changed after an earthquake in antiquity. By analyzing the flow rates and water supply capabilities of the aqueduct, the research demonstrates its efficiency in providing water to urban populations. The study reveals that the Kemerdere Aqueduct could supply water to approximately 8,500 to 15,000 people daily, accounting for losses due to leakage and other inefficiencies. This highlights the advanced engineering skills of the Romans and their ability to manage water resources effectively. The findings emphasize the importance of historical technologies in addressing contemporary water management challenges and underscore the significance of preserving ancient engineering marvels. By reconstructing and evaluating the aqueduct's operation, the study contributes to a deeper understanding of Roman water management practices and their enduring relevance. The meticulous analysis of the Kemerdere Aqueduct enhances our appreciation of Roman engineering ingenuity.
- Open Access
- 9 August 2023
- Published by Uludag University Journal of the Faculty of Engineering in Uludağ University Journal of The Faculty of Engineering
- Vol. 28 (2) , 579-596
OZON TEMAS TANKLARININ HİDROLİK VE KARIŞIM VERİMLERİNİN İYİLEŞTİRİLMESİ
İçme sularının dezenfeksiyon maliyetleri kentleşme, nüfus artışı ve yüksek enerji kullanımı nedeniyle her geçen gün artmaktadır. Ozon ile içme sularının dezenfeksiyonu ön dezenfeksiyon yöntemi olarak ülkemizde bazı içme suyu arıtma tesislerinde kullanılmakta olup Dünya’da giderek yaygınlaşmaktadır. Ülkemizde de yakın zamanda ozonla dezenfeksiyon sürecinin yaygınlaşacağı beklenmektedir. Bu çalışmada, bir içme suyu arıtma tesisinde bulunan ozon temas tankının hidrolik ve karışım verimleri sayısal benzetimler ile değerlendirilmiştir. OpenFOAM açık kaynak kodlu yazılımı kullanılarak gerçekleştirilen sayısal benzetimler ile öncelikle akım yapısı detaylı olarak incelenmiştir. Daha sonra, Üç Yarıklı Perde (ÜYP) ve Gözenekli Perde (GP) tasarımları tank içerisinde uygulanarak akım yapısındaki değişimler elde edilmiştir. Çalışmanın son bölümünde bozunmasız izleyici sayısal benzetimleri ile tankın hidrolik ve karışım verimleri Klasik Perde (KP), ÜYP ve GP tasarımları için ayrı ayrı değerlendirilerek tankın verim artışı değerlendirilmiştir.
- 9 August 2023
- Published by Uludag University Journal of the Faculty of Engineering in Uludağ University Journal of The Faculty of Engineering
- Vol. 28 (2) , 579-596
Open AccessOZON TEMAS TANKLARININ HİDROLİK VE KARIŞIM VERİMLERİNİN İYİLEŞTİRİLMESİ
İçme sularının dezenfeksiyon maliyetleri kentleşme, nüfus artışı ve yüksek enerji kullanımı nedeniyle her geçen gün artmaktadır. Ozon ile içme sularının dezenfeksiyonu ön dezenfeksiyon yöntemi olarak ülkemizde bazı içme suyu arıtma tesislerinde kullanılmakta olup Dünya’da giderek yaygınlaşmaktadır. Ülkemizde de yakın zamanda ozonla dezenfeksiyon sürecinin yaygınlaşacağı beklenmektedir. Bu çalışmada, bir içme suyu arıtma tesisinde bulunan ozon temas tankının hidrolik ve karışım verimleri sayısal benzetimler ile değerlendirilmiştir. OpenFOAM açık kaynak kodlu yazılımı kullanılarak gerçekleştirilen sayısal benzetimler ile öncelikle akım yapısı detaylı olarak incelenmiştir. Daha sonra, Üç Yarıklı Perde (ÜYP) ve Gözenekli Perde (GP) tasarımları tank içerisinde uygulanarak akım yapısındaki değişimler elde edilmiştir. Çalışmanın son bölümünde bozunmasız izleyici sayısal benzetimleri ile tankın hidrolik ve karışım verimleri Klasik Perde (KP), ÜYP ve GP tasarımları için ayrı ayrı değerlendirilerek tankın verim artışı değerlendirilmiştir.
- Open Access
The structure of vortical flow over a rounded broad-crested weir
Turbulent flow over a rounded broad-crested weir is investigated by means of detached eddy simulation (DES) and large eddy simulation (LES) with special emphasis on the interaction of coherent vortex structures with free-surface. In order to set up and validate the computational model, experimental studies were conducted in a laboratory flume using a moderately rounded broad-crested weir with a rounding ratio of R/P=0.15, where R is the radius of the upstream nose and P is the height of the weir. The simulated mean velocity, Reynolds stresses and free-surface profiles show good agreement with the experimental measurements. Spatial variation of the boundary layer on the crest is well captured using a dimensionless form of the Lamb vector divergence. Boundary layer shape factor calculated over the weir was found to be lie between 0.76 and 0.92. A horseshoe vortex system emanating from the bottom of the channel interacts with the free-surface at the entrance of the crest causing undulation on the free-surface. Unsteady characteristics of the flow are examined in terms of the power spectral density (PSD) of vortex-induced forces acting on the weir. It is found that a free-surface boundary layer develops from the undulation to the wall boundary layer on the crest. It was revealed from the simulations for various Reynolds numbers that the installation of an artificial pool upstream of the weir significantly modified vortex structures and reduced undulation effects by 86% according to a proposed undulation index.
Open AccessThe structure of vortical flow over a rounded broad-crested weir
Turbulent flow over a rounded broad-crested weir is investigated by means of detached eddy simulation (DES) and large eddy simulation (LES) with special emphasis on the interaction of coherent vortex structures with free-surface. In order to set up and validate the computational model, experimental studies were conducted in a laboratory flume using a moderately rounded broad-crested weir with a rounding ratio of R/P=0.15, where R is the radius of the upstream nose and P is the height of the weir. The simulated mean velocity, Reynolds stresses and free-surface profiles show good agreement with the experimental measurements. Spatial variation of the boundary layer on the crest is well captured using a dimensionless form of the Lamb vector divergence. Boundary layer shape factor calculated over the weir was found to be lie between 0.76 and 0.92. A horseshoe vortex system emanating from the bottom of the channel interacts with the free-surface at the entrance of the crest causing undulation on the free-surface. Unsteady characteristics of the flow are examined in terms of the power spectral density (PSD) of vortex-induced forces acting on the weir. It is found that a free-surface boundary layer develops from the undulation to the wall boundary layer on the crest. It was revealed from the simulations for various Reynolds numbers that the installation of an artificial pool upstream of the weir significantly modified vortex structures and reduced undulation effects by 86% according to a proposed undulation index.
- 1 July 2022
- Published by Teknik Dergi in Teknik Dergi
- Vol. 33 (4) , 12163-12182
Experimental Study of Hydrodynamic Pressures Acting on a Submerged Gate
Vortical flow formed by a submerged hydraulic jump may produce significant hydrodynamic lift and drag pressures on a gate beneath the hydraulic jump. In this study, an experimental setup equipped with multi-pressure sensors was used to measure fluctuating impact pressures on the submerged gate for different flow conditions characterized by the inlet Froude number and submergence factor (S). Time-averaged and instantaneous pressure coefficients are evaluated based on simultaneous measurements of wall pressures at multiple locations, including those at the lip and downstream face of the gate. In particular, instantaneous lift pressure coefficients are observed to be independent of the submergence ratio for S > 0.6. It is found that low Froude number flows produce high surface pressure fluctuations and the dominant frequency of pressure fluctuations shifts to higher frequency as the Froude number increases. Pressure measurements for the free hydraulic jump suggest that the power spectra of lift pressure fluctuations are devoid of any significant energy level, whereas the resulting power spectra of the submerged flow exhibits significant energy level in the frequency range of 14-19 Hz. The proposed measurement system can be used for the in situ identification of hydrodynamic pressures acting on the gates in irrigation canals.
- 1 July 2022
- Published by Teknik Dergi in Teknik Dergi
- Vol. 33 (4) , 12163-12182
Experimental Study of Hydrodynamic Pressures Acting on a Submerged Gate
Vortical flow formed by a submerged hydraulic jump may produce significant hydrodynamic lift and drag pressures on a gate beneath the hydraulic jump. In this study, an experimental setup equipped with multi-pressure sensors was used to measure fluctuating impact pressures on the submerged gate for different flow conditions characterized by the inlet Froude number and submergence factor (S). Time-averaged and instantaneous pressure coefficients are evaluated based on simultaneous measurements of wall pressures at multiple locations, including those at the lip and downstream face of the gate. In particular, instantaneous lift pressure coefficients are observed to be independent of the submergence ratio for S > 0.6. It is found that low Froude number flows produce high surface pressure fluctuations and the dominant frequency of pressure fluctuations shifts to higher frequency as the Froude number increases. Pressure measurements for the free hydraulic jump suggest that the power spectra of lift pressure fluctuations are devoid of any significant energy level, whereas the resulting power spectra of the submerged flow exhibits significant energy level in the frequency range of 14-19 Hz. The proposed measurement system can be used for the in situ identification of hydrodynamic pressures acting on the gates in irrigation canals.
- Open Access
A Perforated Baffle Design to Improve Mixing in Contact Tanks
In this study, a perforated baffle design is proposed to improve mixing in contact tanks. Turbulent flow through the perforated baffle is studied at the perforation hole scale. The contribution of jets emerging from the perforations to the mixing process is evaluated in terms of standard mixing indexes for various perforation parameters, such as the solidity ratio and hole diameter. Based on numerical simulation results, the two sets of perforated baffles that yielded the highest performance were manufactured from polycarbonate and tracer studies were conducted on a laboratory model. Comparison of numerical and experimental results demonstrates that the numerical model developed is reliable in simulating the flow through the perforated baffles and the associated mixing level in the contact tank. Numerical simulations indicate that the jet flow structure through the perforated baffle penetrates to the recirculation zones in the neighboring chambers and turns the dead zones into active mixing zones. Furthermore, large scale turbulent eddies shed by the perforations contribute to the mixing process in the chambers of the tank. With the use of the perforated baffle design, it is shown that the hydraulic efficiency of the tank can be improved from average to superior according to the baffling factor, and the associated mixing in the proposed design can be improved by 31% according to the Morrill index.
Open AccessA Perforated Baffle Design to Improve Mixing in Contact Tanks
In this study, a perforated baffle design is proposed to improve mixing in contact tanks. Turbulent flow through the perforated baffle is studied at the perforation hole scale. The contribution of jets emerging from the perforations to the mixing process is evaluated in terms of standard mixing indexes for various perforation parameters, such as the solidity ratio and hole diameter. Based on numerical simulation results, the two sets of perforated baffles that yielded the highest performance were manufactured from polycarbonate and tracer studies were conducted on a laboratory model. Comparison of numerical and experimental results demonstrates that the numerical model developed is reliable in simulating the flow through the perforated baffles and the associated mixing level in the contact tank. Numerical simulations indicate that the jet flow structure through the perforated baffle penetrates to the recirculation zones in the neighboring chambers and turns the dead zones into active mixing zones. Furthermore, large scale turbulent eddies shed by the perforations contribute to the mixing process in the chambers of the tank. With the use of the perforated baffle design, it is shown that the hydraulic efficiency of the tank can be improved from average to superior according to the baffling factor, and the associated mixing in the proposed design can be improved by 31% according to the Morrill index.
- Open Access
- 1 January 2020
- Published by Pamukkale University in Pamukkale University Journal of Engineering Sciences
- Vol. 26 (3) , 455-461
Experimental investigation of turbulent flow upstream of the broad-crested weir
- 1 January 2020
- Published by Pamukkale University in Pamukkale University Journal of Engineering Sciences
- Vol. 26 (3) , 455-461
Open AccessExperimental investigation of turbulent flow upstream of the broad-crested weir
- Open Access
Efficiency Enhancement of Chlorine Contact Tanks in Water Treatment Plants: A Full-Scale Application
The mixing and disinfection performance of a full-scale chlorine contact tank (CCT) is thoroughly investigated by means of numerical simulations for seasonal water supply variations in the water treatment plant (WTP) of Eskisehir in Turkey. Velocity measurements and tracer studies are carried out on a 1:10 scale laboratory model of the CCT to validate the numerical model. A good agreement between numerical and experimental results shows that the numerical model developed can be reliably used for the simulation of turbulent flow and solute transport in the full-scale CCT. Tracer studies indicate that the hydraulic performance of the CCT is classified as “average” according to the baffling factor, while the Morrill, Aral-Demirel (AD), and dispersion indexes indicate low mixing due to the recirculating and short-circuiting effects inside the chambers of the CCT. With respect to the first order modeling of chlorine decay and pathogen inactivation, chlorine concentrations are found to be significantly distinct for seasonal variations in water supply to maintain 3-log inactivation of Giardia cysts. A recently developed and patented slot-baffle design (SBD) is then applied to the full-scale CCT. It is found that the hydraulic efficiency of the CCT is improved to “high” and the Morrill index approaches 2, which identifies the system as a perfect mixing tank. Using the SBD, the chlorine demand has been successfully decreased by 19% while providing equivalent inactivation level. The novel SBD design also reduces energy loses in the turbulent flow through the tank and increases the energy efficiency of the CCT by 62%, which is significant for energy considerations in modern cities.
Open AccessEfficiency Enhancement of Chlorine Contact Tanks in Water Treatment Plants: A Full-Scale Application
The mixing and disinfection performance of a full-scale chlorine contact tank (CCT) is thoroughly investigated by means of numerical simulations for seasonal water supply variations in the water treatment plant (WTP) of Eskisehir in Turkey. Velocity measurements and tracer studies are carried out on a 1:10 scale laboratory model of the CCT to validate the numerical model. A good agreement between numerical and experimental results shows that the numerical model developed can be reliably used for the simulation of turbulent flow and solute transport in the full-scale CCT. Tracer studies indicate that the hydraulic performance of the CCT is classified as “average” according to the baffling factor, while the Morrill, Aral-Demirel (AD), and dispersion indexes indicate low mixing due to the recirculating and short-circuiting effects inside the chambers of the CCT. With respect to the first order modeling of chlorine decay and pathogen inactivation, chlorine concentrations are found to be significantly distinct for seasonal variations in water supply to maintain 3-log inactivation of Giardia cysts. A recently developed and patented slot-baffle design (SBD) is then applied to the full-scale CCT. It is found that the hydraulic efficiency of the CCT is improved to “high” and the Morrill index approaches 2, which identifies the system as a perfect mixing tank. Using the SBD, the chlorine demand has been successfully decreased by 19% while providing equivalent inactivation level. The novel SBD design also reduces energy loses in the turbulent flow through the tank and increases the energy efficiency of the CCT by 62%, which is significant for energy considerations in modern cities.
- Open Access
Effect of Porous Baffles on the Energy Performance of Contact Tanks in Water Treatment
Three-dimensional numerical simulations are performed to evaluate the effect of porous baffles on the efficiency of water treatment contact tanks. A second-order accurate numerical model is employed for the solutions of unsteady flow and tracer transport through the porous baffles. The flow through the porous medium is characterized while using the Darcy-Forchheimer relationship. Large Eddy Simulation (LES) model is used to simulate the instantaneous mixing of the tracer in the chambers of the contact tank. Three different porosities are considered to evaluate the effect of porosity on the hydraulic and mixing efficiencies of the contact tank. Simulated time-averaged flow field shows that porous baffles that are placed at the entrance of each chamber could successfully mitigate short-circuiting and yield plug-flow conditions through the system for low porosities. Flow in the contact tank becomes laminar as the flow velocities decrease due to viscous effects and inertial resistance in the porous zone. For this case, the tracer is transported with bulk flow through the system and leaves the contact tank with a high peak seen in the Residence Time Distribution (RTD) plot. Porous layer increases the hydraulic efficiency of the conventional design from “poor” to “good” according to the baffling factor and increases the overall efficiency from “compromising” to “good” according to the AD index. Comparison of the performance of the porous layer with the previously developed slot-baffle design shows that the slot-baffle design increases the efficiency of the tank with increasing dispersion effects, whereas the porous design increases hydraulic efficiency and reduces the dispersion effects. While the porous design reduces energy efficiency by 33% due to a drastic increase in drag in the flow through porous zone, the slot-baffle design increases the energy efficiency of the conventional design by 67%.
Open AccessEffect of Porous Baffles on the Energy Performance of Contact Tanks in Water Treatment
Three-dimensional numerical simulations are performed to evaluate the effect of porous baffles on the efficiency of water treatment contact tanks. A second-order accurate numerical model is employed for the solutions of unsteady flow and tracer transport through the porous baffles. The flow through the porous medium is characterized while using the Darcy-Forchheimer relationship. Large Eddy Simulation (LES) model is used to simulate the instantaneous mixing of the tracer in the chambers of the contact tank. Three different porosities are considered to evaluate the effect of porosity on the hydraulic and mixing efficiencies of the contact tank. Simulated time-averaged flow field shows that porous baffles that are placed at the entrance of each chamber could successfully mitigate short-circuiting and yield plug-flow conditions through the system for low porosities. Flow in the contact tank becomes laminar as the flow velocities decrease due to viscous effects and inertial resistance in the porous zone. For this case, the tracer is transported with bulk flow through the system and leaves the contact tank with a high peak seen in the Residence Time Distribution (RTD) plot. Porous layer increases the hydraulic efficiency of the conventional design from “poor” to “good” according to the baffling factor and increases the overall efficiency from “compromising” to “good” according to the AD index. Comparison of the performance of the porous layer with the previously developed slot-baffle design shows that the slot-baffle design increases the efficiency of the tank with increasing dispersion effects, whereas the porous design increases hydraulic efficiency and reduces the dispersion effects. While the porous design reduces energy efficiency by 33% due to a drastic increase in drag in the flow through porous zone, the slot-baffle design increases the energy efficiency of the conventional design by 67%.