Chayakorn Petchakup
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chayakorn Petchakup has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Han Wei Hou
Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore
2 shared publications - King Ho Holden Li
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
2 shared publications - Hui Min Tay
Lee Kong Chian School Of Medicine, Nanyang Technological University, Singapore
1 shared publication - Nishanth Menon
Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
1 shared publication
Latest Publications
- Open Access
- 21 July 2017
- Published by MDPI AG
SINGLE CELL IMPEDANCE CYTOMETRY FOR RAPID AND LABEL-FREE MONOCYTE PHENOTYPING
Monocytes represent a highly heterogeneous leukocyte population with the ability to differentiate into macrophages, a major cell type involved in the pathogenesis of atherosclerotic plaque in cardiovascular diseases [1,2]. Label-free analysis of their native cellular phenotypes and functions not only reduces assay cost and time, but is also essential for understanding disease progression and development of novel therapeutic strategies. Impedance cytometry is an emerging technology for high throughput cell phenotyping based on intrinsic electrical properties without the use of antibodies [3,4]. While parallel electrodes offer higher detection sensitivity as compared to co-planar electrodes [3,4], it is limited by laborious microfabrication. Herein, we present the development of an efficient microfluidics impedance cytometer using coplanar electrodes for rapid monocyte identification and phenotyping based on differentiation status. The microfluidics impedance cytometer consists of a two-inlet, two-outlet polydimethylsiloxane (PDMS) microchannel (30 μm (width) × 20 μm (height)) bonded on patterned coplanar electrodes (20 μm in width with 20 μm separation gap). Sample and sheath fluid are injected into the device to hydrodynamically focus the cells at the channel center prior electrical detection. As the cell moves through the detection region, it disrupts the electric field generated by coplanar electrodes, thereby causing a change in electrical impedance. Using our setup (Fig. 1), the change in electrical impedance was quantified based on current change, and various cellular information were extracted at different frequencies of the excitation signal. We measured two impedance parameters namely the 1) opacity (ratio of impedance magnitude at 0.3MHz (|ZLF|) to impedance magnitude at 1.7MHz (|ZHF|)) which reflects cell membrane capacitance, and 2) |ZLF| which characterize cell size. For identification of different blood cell types, human monocytes and lymphocytes purified using Dean Flow Fractionation (DFF) [5], and diluted red blood cells (RBCs) samples were separately injected into the microdevice. As shown in figure 2, different cell types were clearly differentiated based on |ZLF| due to distinct cell size differences (monocytes: 10 – 12 µm, lymphocytes: 7 – 8 µm, and red blood cells: 6 – 8 µm). Characterization of primary monocytes and leukemic THP-1 monocytic cell line also showed distinct differences in size and opacity (Fig. 3). Lastly, we compared the impedance profile of THP-1 and differentiated macrophages (PMA stimulated), and found that macrophages were more heterogeneous in size with significantly lower opacity than THP-1, demonstrating the feasibility of real-time assessment of monocyte differentiation using impedance-based sensing (Fig. 4). In conclusion, the developed microdevice enables continuous label-free monocyte phenotyping using coplanar electrodes configuration with sufficient sensitivity. With the design simplicity and low cost fabrication, we envision our method will greatly facilitate immunology research and point-of-care monocyte profiling in patients with cardiovascular diseases.
- 21 July 2017
- Published by MDPI AG
Open AccessSINGLE CELL IMPEDANCE CYTOMETRY FOR RAPID AND LABEL-FREE MONOCYTE PHENOTYPING
Monocytes represent a highly heterogeneous leukocyte population with the ability to differentiate into macrophages, a major cell type involved in the pathogenesis of atherosclerotic plaque in cardiovascular diseases [1,2]. Label-free analysis of their native cellular phenotypes and functions not only reduces assay cost and time, but is also essential for understanding disease progression and development of novel therapeutic strategies. Impedance cytometry is an emerging technology for high throughput cell phenotyping based on intrinsic electrical properties without the use of antibodies [3,4]. While parallel electrodes offer higher detection sensitivity as compared to co-planar electrodes [3,4], it is limited by laborious microfabrication. Herein, we present the development of an efficient microfluidics impedance cytometer using coplanar electrodes for rapid monocyte identification and phenotyping based on differentiation status. The microfluidics impedance cytometer consists of a two-inlet, two-outlet polydimethylsiloxane (PDMS) microchannel (30 μm (width) × 20 μm (height)) bonded on patterned coplanar electrodes (20 μm in width with 20 μm separation gap). Sample and sheath fluid are injected into the device to hydrodynamically focus the cells at the channel center prior electrical detection. As the cell moves through the detection region, it disrupts the electric field generated by coplanar electrodes, thereby causing a change in electrical impedance. Using our setup (Fig. 1), the change in electrical impedance was quantified based on current change, and various cellular information were extracted at different frequencies of the excitation signal. We measured two impedance parameters namely the 1) opacity (ratio of impedance magnitude at 0.3MHz (|ZLF|) to impedance magnitude at 1.7MHz (|ZHF|)) which reflects cell membrane capacitance, and 2) |ZLF| which characterize cell size. For identification of different blood cell types, human monocytes and lymphocytes purified using Dean Flow Fractionation (DFF) [5], and diluted red blood cells (RBCs) samples were separately injected into the microdevice. As shown in figure 2, different cell types were clearly differentiated based on |ZLF| due to distinct cell size differences (monocytes: 10 – 12 µm, lymphocytes: 7 – 8 µm, and red blood cells: 6 – 8 µm). Characterization of primary monocytes and leukemic THP-1 monocytic cell line also showed distinct differences in size and opacity (Fig. 3). Lastly, we compared the impedance profile of THP-1 and differentiated macrophages (PMA stimulated), and found that macrophages were more heterogeneous in size with significantly lower opacity than THP-1, demonstrating the feasibility of real-time assessment of monocyte differentiation using impedance-based sensing (Fig. 4). In conclusion, the developed microdevice enables continuous label-free monocyte phenotyping using coplanar electrodes configuration with sufficient sensitivity. With the design simplicity and low cost fabrication, we envision our method will greatly facilitate immunology research and point-of-care monocyte profiling in patients with cardiovascular diseases.
- Open Access
- 12 March 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (3) , 87
Advances in Single Cell Impedance Cytometry for Biomedical Applications
Microfluidics impedance cytometry is an emerging research tool for high throughput analysis of dielectric properties of cells and internal cellular components. This label-free method can be used in different biological assays including particle sizing and enumeration, cell phenotyping and disease diagnostics. Herein, we review recent developments in single cell impedance cytometer platforms, their biomedical and clinical applications, and discuss the future directions and challenges in this field.
- 12 March 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (3) , 87
Open AccessAdvances in Single Cell Impedance Cytometry for Biomedical Applications
Microfluidics impedance cytometry is an emerging research tool for high throughput analysis of dielectric properties of cells and internal cellular components. This label-free method can be used in different biological assays including particle sizing and enumeration, cell phenotyping and disease diagnostics. Herein, we review recent developments in single cell impedance cytometer platforms, their biomedical and clinical applications, and discuss the future directions and challenges in this field.