YZYidong Zhao

Yidong Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yidong Zhao has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Commissioning of the Tender X-ray Beamline at the High Energy Photon Source

    by Yongyang Wang, Kun Tang, Shuhu Liu, Chenyan Ma, Xiaojuan Zhao, Dongmei Liu, Yidong Zhao, Lei Zheng

    The Tender X-ray Beamline (TEX), using a bending magnet as a light source, is the first beamline of the High Energy Photon Source (HEPS) to undergo commissioning. It covers an energy range from 2.1 keV to 11 keV. Dynamic diagnostic tools have been installed and can measure the photon flux, energy resolution and position stability. By use of these tools, TEX was found to achieve a photon flux of up to 9 × 10 11 photons s −1 , with an energy resolution of 5904 @ 3203.6 eV and position stability lower than ±3 µm (horizontal) × 15 µm (vertical). In this paper, the diagnostic process of the beamline and its performance will be introduced in detail.


  • Open Access

    Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer

    by Fan Li, Yidong Zhao, Peiwei Wang, Kun Tang, Lei Zheng

    Absolute measurement of radiant power in the X-ray region is essential for many applications in astrophysics, spectroscopy, and X-ray diagnostics. Comparison between different measuring methods is an effective way to check their reliability. In the present work, a comparison of X-ray radiant power absolute measurement between a free-air ionization chamber and a cryogenic electrical substitution radiometer was performed at Beijing Synchrotron Radiation Facility. The absolute radiant power obtained by these two methods were mutually compared via a transfer standard detector’s spectral responsivity at a photon energy of 10 keV. The result of the comparison showed that the difference was 0.47%. A conclusion was reached that the free-air ionization chamber and the cryogenic electrical substitution radiometer agreed within the combined relative uncertainty of 3.35%.


  • Open Access

    A magnetically controlled chemical–mechanical polishing (MC-CMP) approach for fabricating channel-cut silicon crystal optics for the High Energy Photon Source

    by Zhen Hong, Qianshun Diao, Wei Xu, Qingxi Yuan, Junliang Yang, Zhongliang Li, Yongcheng Jiang, Changrui Zhang, Dongni Zhang, Fang Liu, et al.

    Crystal monochromators are indispensable optical components for the majority of beamlines at synchrotron radiation facilities. Channel-cut monochromators are sometimes chosen to filter monochromatic X-ray beams by virtue of their ultrahigh angular stability. Nevertheless, high-accuracy polishing on the inner diffracting surfaces remains challenging, thus hampering their performance in preserving the coherence or wavefront of the photon beam. Herein, a magnetically controlled chemical–mechanical polishing (MC-CMP) approach has been successfully developed for fine polishing of the inner surfaces of channel-cut crystals. This MC-CMP process relieves the constraints of narrow working space dictated by small offset requirements and achieves near-perfect polishing on the surface of the crystals. Using this method, a high-quality surface with roughness of 0.614 nm (root mean square, r.m.s.) is obtained in a channel-cut crystal with 7 mm gap designed for beamlines at the High Energy Photon Source, a fourth-generation synchrotron radiation source under construction. On-line X-ray topography and rocking-curve measurements indicate that the stress residual layer on the crystal surface was removed. Firstly, the measured rocking-curve width is in good agreement with the theoretical value. Secondly, the peak reflectivity is very close to theoretical values. Thirdly, topographic images of the optics after polishing were uniform without any speckle or scratches. Only a nearly 2.5 nm-thick SiO2 layer was observed on the perfect crystalline matrix from high-resolution transmission electron microscopy photographs, indicating that the structure of the bulk material is defect- and dislocation-free. Future development of MC-CMP is promising for fabricating wavefront-preserving and ultra-stable channel-cut monochromators, which are crucial to exploit the merits of fourth-generation synchrotron radiation sources or hard X-ray free-electron lasers.


  • Optical design and optimization study of metrology sector at high energy photon source

    by Xiaojuan Zhao, Yidong Zhao, Lei Zheng, Kun Tang, Shuhu Liu, Fan Li, Jianmin Li


  • A micro-focusing and high-flux-throughput beamline design using a bending magnet for microscopic XAFS at the High Energy Photon Source

    by Kun Tang, Lei Zheng, Yi Dong Zhao, Shu Hu Liu, Chen Yan Ma, Yu Hui Dong

    An optical design study of a bending-magnet beamline, based on multi-bend achromat storage ring lattices, at the High Energy Photon Source, to be built in Beijing, China, is described. The main purpose of the beamline design is to produce a micro-scale beam from a bending-magnet source with little flux loss through apertures. To maximize the flux of the focal spot, the synchrotron source will be 1:1 imaged to a virtual source by a toroidal mirror; a mirror pair will be used to collimate the virtual source into quasi-parallel light which will be refocused by a Kirkpatrick–Baez mirror pair. In the case presented here, a beamline for tender X-rays ranging from 2.1 keV to 7.8 keV, with a spot size of approximately 7 µm (H) × 6 µm (V) and flux up to 2 × 1012 photons s−1, can be achieved for the purpose of X-ray absorption fine-structure (XAFS)-related experiments, such as scanning micro-XAFS and full-field nano-XAFS.


  • Open Access

    Synchrotron Radiation Based Study of the Catalytic Mechanism of Ag+ to Chalcopyrite Bioleaching by Mesophilic and Thermophilic Cultures

    by Zhenyuan Nie, Weiwei Zhang, Hongchang Liu, Jinlan Xia, Wei Zhu, Duorui Zhang, Lei Zheng, Chenyan Ma, Yidong Zhao, Wen Wen

    The catalytic mechanism of Ag+ for chalcopyrite bioleaching by mesophilic culture (at 30 °C) and thermophilic culture (at 48 °C) was investigated using synchrotron radiation-based X-ray diffraction (SR-XRD) and S K-edge and Fe L-edge X-ray absorption near edge structure (XANES) spectroscopy. Bioleaching experiments showed that copper extraction from chalcopyrite bioleaching by both cultures was promoted significantly by Ag+, with more serious corrosion occurring on the minerals surface. SR-XRD and XANES analyses showed that the intermediates S0, jarosite and secondary minerals (bornite, chalcocite and covellite) formed for all bioleaching experiments. For these secondary minerals, the formation of bornite and covellite was promoted significantly in the presence of Ag+ for both cultures, while Ag+ has almost no effect on the formation of chalcocite. These results provided insight into the catalytic mechanisms of Ag+ to chalcopyrite bioleaching by the mesophilic and thermophilic cultures, which are both probably due to the rapid formation of bornite by Ag+ and the conversion of bornite to covellite.


  • A soft X-ray cryogenic radiometer built on BSRF

    by Xiaoliang Zhao, Yidong Zhao, Kun Tang, Yashuai Zhao, Fan Li, Lei Zheng, Shuhu Liu


  • Open Access

    The Evidence of Decisive Effect of Both Surface Microstructure and Speciation of Chalcopyrite on Attachment Behaviors of Extreme Thermoacidophile Sulfolobus metallicus

    by Weibo Ling, Lei Wang, Hongchang Liu, Zhenyuan Nie, Yun Yang, Yi Yang, Chenyan Ma, Lei Zheng, Yidong Zhao, Jinlan Xia

    The effect of the surface microstructure and chemical speciation of chalcopyrite on the attachment behaviors of thermoacidophilic archaeon Sulfolobus metallicus was evaluated for the first time by using integrated techniques including epifluorescence microscopy (EFM) and sulfur K-edge X-ray absorption near edge structure (S K-edge XANES) spectroscopy, as well as scanning electron microscopy with energy dispersive spectrometry (SEM/EDS) and Fourier transform infrared (FT-IR) spectroscopy. In order to obtain the specific surface, the chalcopyrite slices were electrochemically oxidized at 0.87 V and reduced at −0.54 V, respectively. The EFM analysis showed that the quantity of cells attaching on the mineral surface increased with time, and the biofilm formed faster on the electrochemically treated slices than on the untreated ones. The SEM-EDS analysis indicated that the deficiency in energy substrate elemental sulfur (S0) in the specific microsize of local defect sites was disadvantageous to the initial attachment of cells. The XANES and FT-IR data suggested that the elemental sulfur (S0) could be in favor of initial attachment, and surface jarosites inhibited the adsorption and growth of S. metallicus. These results demonstrated that not only the surface microstructure but also the chemical speciation defined the initial attachment behaviors and biofilm growth of the extreme thermophilic archaeon S. metallicus.


  • A new method to suppress high-order harmonics for a synchrotron radiation soft X-ray beamline

    by Zhi-Ying Guo, Hai-Ying Xing, Cai-Hao Hong, Kun Tang, Yong Han, Dong-Liang Chen, Yi-Dong Zhao

    A feasible and convenient method is proposed to suppress higher-harmonics for a varied-line-spacing plane grating monochromator in the soft X-ray region. Related calculations and experiments demonstrate that decreasing the included angle slightly by changing the parameter of the exit arm length can significantly improve light purity. This method is suitable and has been used for experiments of detector calibration in beamline 4B7B at the Beijing Synchrotron Radiation Facility (BSRF).

  • A new soft X-ray magnetic circular dichroism facility at the BSRF beamline 4B7B

    by Zhi-Ying Guo, Cai-Hao Hong, Hai-Ying Xing, Kun Tang, Lei Zheng, Wei Xui, Dong-Liang Chen, Ming-Qi Cui, Yi-Dong Zhao

    X-ray magnetic circular dichroism (XMCD) has become an important and powerful tool because it allows the study of material properties in combination with elemental specificity, chemical state specificity, and magnetic specificity. A new soft X-ray magnetic circular dichroism apparatus has been developed at the Beijing Synchrotron Radiation Facility (BSRF). The apparatus combines three experimental conditions: an ultra-high-vacuum environment, moderate magnetic fields and in-situ sample preparation to measure the absorption signal. We designed a C-type dipole electromagnet that provides magnetic fields up to 0.5 T in parallel (or anti-parallel) direction relative to the incoming X-ray beam. The performances of the electromagnet are measured and the results show good agreement with the simulation ones. Following film grown in situ by evaporation methods, XMCD measurements are performed. Combined polarization corrections, the magnetic moments of the Fe and Co films determined by sum rules are consistent with other theoretical predictions and experimental measurements.