THTuan-Viet Hoang

Tuan-Viet Hoang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tuan-Viet Hoang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Jong-Min Oh

    Kwangwoon University

    1 shared publication
  • Jouan Rashidi

    Deptartment of Environmental Science and Engineering, College of Engineering, Center for Environmental Studies, Kyung Hee University, Seocheon-dong 1, Giheung-gu, Yongin-si, Gyeonggi-do 446-701, Korea

    1 shared publication
  • KiJeon Nam

    Department of Environmental Engineering, Pukyong National University, Busan 48513, Republic of Korea

    1 shared publication
  • Pouya Ifaei

    Integrated Engineering, Department of Environmental Science and Engineering, College of Engineering, Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si 17104, Republic of Korea

    1 shared publication
  • Soonho Hwangbo

    Department of Chemical Engineering, Gyeongsang National University, Jinju-daero 501, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea

    1 shared publication

Latest Publications

  • Open Access

    Optimal Management of a Hybrid Renewable Energy System Coupled with a Membrane Bioreactor Using Enviro-Economic and Power Pinch Analyses for Sustainable Climate Change Adaption

    by Tuan-Viet Hoang, Pouya Ifaei, Kijeon Nam, Jouan Rashidi, Soonho Hwangbo, Jong-Min Oh, ChangKyoo Yoo

    This study proposed an optimal hybrid renewable energy system (HRES) to sustainably meet the dynamic electricity demand of a membrane bioreactor. The model-based HRES consists of solar photovoltaic panels, wind turbines, and battery banks with grid connectivity. Three scenarios, 101 sub-scenarios, and three management cases were defined to optimally design the system using a novel dual-scale optimization approach. At the system scale, the power-pinch analysis was applied to minimize both the size of components and the outsourced needed electricity (NE) from Vietnam’s electrical grid. At a local-scale, economic and environmental models were integrated, and the system was graphically optimized using a novel objective function, combined enviro-economic costs (CEECs). The results showed that the optimal CEECs were $850,710/year, $1,030,628/year, and $1,693,476/year for the management cases under good, moderate, and unhealthy air qualities, respectively. The smallest CEEC was obtained when 47% of the demand load of the membrane bioreactor was met using the HRES and the rest was supplied by the grid, resulting in 6,800,769 kg/year of CO2 emissions.