ACAnna Laura Costa

Anna Laura Costa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anna Laura Costa has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Colonization of Legionella spp. in Hot and Cold Water Networks of Residential Buildings in Pisa District (Tuscany, Italy): A Five-Years Survey

    by Michele Totaro, Anna Laura Costa, Lorenzo Frendo, Erica De Vita, Serena Giorgi, Beatrice Casini, Paola Valentini, Antonio Gallo, Gaetano Privitera, Angelo Baggiani

    Literature data on Legionella spp. presence in houses water networks have been increasing during the last years, but epidemiological reports assert a high incidence of Legionnaires’ disease infection in Italy. Updating our previously published data, we report a five-year survey on Legionella spp. colonization in 235 buildings with an independent hot water production (IB); 82 buildings with a central hot water production (CB); and 58 buildings with a solar thermal system for hot water production (TB). In all the 375 buildings Legionella spp. was researched in hot and cold water samples and microbiological potability standards of cold water were evaluated. Legionella spp. was detected in 27% of the water networks, mostly in CB and TB. We detected correlations between the presence of bacteria and some physical-chemical parameters (low chlorine level and optimal temperature for Legionella spp. growth). Cold water resulted free from microbiological hazards, except for coliform bacteria isolated in three separate cases, and Legionella spp., detected when cold water temperature was about 20°C. After a five-year survey we confirm the presence of a Legionnaires’ disease risk and the need of training programs for all the workers involved in residential water systems management.

  • Open Access

    Microbiological Air Quality in Heating, Ventilation and Air Conditioning Systems of Surgical and Intensive Care Areas: The Application of a Disinfection Procedure for Dehumidification Devices

    by Michele Totaro, Anna Laura Costa, Beatrice Casini, Sara Profeti, Antonio Gallo, Lorenzo Frendo, Andrea Porretta, Paola Valentini, Gaetano Privitera, Angelo Baggiani

    International literature data report that the increase of infectious risk may be due to heating, ventilation and air conditioning (HVAC) systems contaminated by airborne pathogens. Moreover, the presence of complex rotating dehumidification wheels (RDWs) may complicate the cleaning and disinfection procedures of the HVAC systems. We evaluated the efficacy of a disinfection strategy applied to the RDW of two hospitals’ HVAC systems. Hospitals have four RDW systems related to the surgical areas (SA1 and SA2) and to the intensive and sub-intensive care (IC and sIC) units. Microbiological air and surface analyses were performed in HVAC systems, before and after the disinfection treatment. Hydrogen peroxide (12%) with silver ions (10 mg/L) was aerosolized in all the air sampling points, located close to the RDW device. After the air disinfection procedure, reductions of total microbial counts at 22 °C and molds were achieved in SA2 and IC HVAC systems. An Aspergillus fumigatus contamination (6 CFU/500 L), detected in one air sample collected in the IC HVAC system, was eradicated after the disinfection. The surface samples proved to be of good microbiological quality. The results suggest the need for a disinfection procedure to improve the microbiological quality of the complex HVAC systems, mostly in surgical and intensive care areas.


  • Open Access

    Improving Cleaning and Disinfection of High-Touch Surfaces in Intensive Care during Carbapenem-Resistant Acinetobacter baumannii Endemo-Epidemic Situations

    by Beatrice Casini, Anna Righi, Nunzio De Feo, Michele Totaro, Serena Giorgi, Lavinia Zezza, Paola Valentini, Enrico Tagliaferri, Anna Laura Costa, Simona Barnini, et al.

    Aims: High-touch surfaces cleaning and disinfection require the adoption of effective and proper executed protocols, especially during carbapenem-resistant Acinetobacter baumannii (CRAB) endemo-epidemic situations. We evaluated the effectiveness and residual disinfectant activity of disposable pre-impregnated wipes (Modified Operative Protocol, MOP) in reducing environmental bioburden versus a two-step Standard Operative Protocol (SOP) in a 12-bed Intensive Care Unit. Methods: Five high-touch surfaces were cleaned and disinfected either according to the SOP (alcohol-based cleaning and chlorine-based disinfection) or using quaternary ammonium compounds-based disposable wipes (MOP). Sampling was performed before each procedure and at 0.5, 2.5, 4.5 and 6.5 h after (560 sites). Total viable count (TVC) was evaluated according to Italian hygiene standard (2). Clinical and environmental CRAB strains isolated were genotyped. Results: On non-electromedical surfaces the difference between TVC before procedure and at each of the following times was significant only for the MOP (p < 0.05, Wilcoxon test). Using the MOP, only 7.4% (10/135) of sites showed TVC >50 CFU/24 cm2 (hygiene failures) versus 18.9% (25/132) after SOP (p < 0.05, Fisher’s Exact test). On infusion pumps a higher number of hygiene failures was observed after the SOP (7/44, 15.9%) compared with the MOP (4/45, 8.9%). Genotyping highlighted a common source of infection. Conclusion: On high-touch surfaces, the use of disposable wipes by in-house auxiliary nurses may represent a more effective alternative to standard cleaning and disinfection procedure performed by outsourced cleaning services, showing effectiveness in reducing microbial contamination and residual disinfection activity up to 6.5 h.


  • Open Access

    Application of Hydrogen Peroxide as an Innovative Method of Treatment for Legionella Control in a Hospital Water Network

    by Beatrice Casini, Francesco Aquino, Michele Totaro, Mario Miccoli, Irio Galli, Laura Manfredini, Carlo Giustarini, Anna Laura Costa, Benedetta Tuvo, Paola Valentini, et al.

    Objectives: To evaluate the effectiveness of hydrogen peroxide (HP) use as a disinfectant in the hospital water network for the control of Legionella spp. colonization. Methods: Following the detection of high levels of Legionella contamination in a 136-bed general hospital water network, an HP treatment of the hot water supply (25 mg/L) was adopted. During a period of 34 months, the effectiveness of HP on Legionella colonization was assessed. Legionella was isolated in accordance with ISO-11731 and identification was carried out by sequencing of the mip gene. Results: Before HP treatment, L. pneumophila sg 2–15 was isolated in all sites with a mean count of 9950 ± 8279 cfu/L. After one-month of HP treatment, we observed the disappearance of L. pneumophila 2–15, however other Legionella species previously not seen were found; Legionella pneumophila 1 was isolated in one out of four sampling sites (2000 cfu/L) and other non-pneumophila species were present in all sites (mean load 3000 ± 2887 cfu/L). Starting from September 2013, HP treatment was modified by adding food-grade polyphosphates, and in the following months, we observed a progressive reduction of the mean load of all species (p < 0.05), resulting in substantial disappearance of Legionella colonization. Conclusion: Hydrogen peroxide demonstrated good efficacy in controlling Legionella. Although in the initial phases of treatment it appeared unable to eliminate all Legionella species, by maintaining HP levels at 25 mg/L and adding food-grade polyphosphates, a progressive and complete control of colonization was obtained.


  • Open Access

    The Effect of Hydrogen Peroxide on Reducing the Colonization of Legionella spp. in a Hospital Water Network

    by Beatrice Casini, Francesco Aquino, Michele Totaro, Mario Miccoli, Irio Galli, Laura Manfredini, Valentino Serini, Anna Laura Costa, Benedetta Tuvo, Paola Valentini, et al.

    Objectives: To evaluate the effectiveness of hydrogen peroxide (HP) use in the hospital water network disinfection to control Legionella spp. colonization. Methods: Following the detection of high levels of Legionella contamination in a 136-bed general hospital water network, an HP treatment of the hot water (25 mg/L) was adopted. During a period of 34 months, the effectiveness of HP on Legionella colonization was assessed. Legionella was isolated in accordance with ISO-11731 and identification was carried out by sequencing of the mip gene. Results: Before HP treatment L.pneumophila sg 2-15 was isolated in all sites with a mean count of 9950±8279 CFU/L. After one month of HP-treatment, we observed the disappearance of L. pneumophila 2-15, however other Legionella species never cultured before appeared; Legionella pneumophila 1 was isolated in 1 out of 4 sampling sites (2,000 CFU/L) and other non-pneumophila species in all sites (mean load 3,000 ±2887 CFU/L). Starting from September 2013, HP-treatment was modified adding food-grade polyphosphates and in the following months we observed a progressive reduction of the mean load of all species (pConclusion: Hydrogen peroxide demonstrated a good efficacy in controlling Legionella. Although in the initial phases of treatment it seemed unable to eliminate all the species, by keeping HP levels to 25 mg/L and adding food-grade polyphosphates, a progressive and complete control of colonisation was obtained.