Chengqiang Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chengqiang Zhao has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chuanqi Ma
School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China
1 shared publication - Guangzhao Zhou
Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, People's Republic of China
1 shared publication - Guohao Du
Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai Synchrotron Radiat Facil, Zhangjiang Lab, 239 Zhangheng Rd, Shanghai 201204, Peoples R China
1 shared publication - Hao Shi
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
1 shared publication - Hong Yu
Key Laboratory of Quantum Optics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
1 shared publication - Hong-Xin Luo
Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, People's Republic of China
1 shared publication
Latest Publications
- Open Access
Ultra-Low Loss and Ultra-Compact Polarization-Insensitive SOI Multimode Waveguide Crossing Based on an Inverse Design Method
Polarization-insensitive waveguide crossings are indispensable components of photonic integrated circuits (PICs), enabling the concurrent computing of optical signals from diverse waveguides inside the limits of a restricted spatial footprint. Leveraging mirror symmetry direct binary search, we successfully demonstrate an ultra-compact and ultra-low loss polarization-insensitive waveguide crossing that achieves insertion losses below −0.11 dB and crosstalk levels beneath −22.6 dB for transverse electric (TE) mode, as well as insertion losses below 0.05 dB and crosstalk levels beneath −24.5 dB for transverse magnetic (TM) mode across the C-band with a footprint of 3 × 4 μm2. The results confirm that this mirror symmetry optimization method yields high-efficiency devices while reducing computational time. We believe this high-efficiency polarization-insensitive waveguide crossing can have potential applications in dense PIC systems.
Open AccessUltra-Low Loss and Ultra-Compact Polarization-Insensitive SOI Multimode Waveguide Crossing Based on an Inverse Design Method
Polarization-insensitive waveguide crossings are indispensable components of photonic integrated circuits (PICs), enabling the concurrent computing of optical signals from diverse waveguides inside the limits of a restricted spatial footprint. Leveraging mirror symmetry direct binary search, we successfully demonstrate an ultra-compact and ultra-low loss polarization-insensitive waveguide crossing that achieves insertion losses below −0.11 dB and crosstalk levels beneath −22.6 dB for transverse electric (TE) mode, as well as insertion losses below 0.05 dB and crosstalk levels beneath −24.5 dB for transverse magnetic (TM) mode across the C-band with a footprint of 3 × 4 μm2. The results confirm that this mirror symmetry optimization method yields high-efficiency devices while reducing computational time. We believe this high-efficiency polarization-insensitive waveguide crossing can have potential applications in dense PIC systems.
- 23 August 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (5) , 1631-1637
High-efficiency fast X-ray imaging detector development at SSRF
Indirect X-ray imaging detectors consisting of scintillator screens, long-working-distance microscope lenses and scientific high-speed complementary metal-oxide semiconductor (CMOS) cameras are usually used to realize fast X-ray imaging with white-beam synchrotron radiation. However, the detector efficiency is limited by the coupling efficiency of the long-working-distance microscope lenses, which is only about 5%. A long-working-distance microscope lenses system with a large numerical aperture (NA) is designed to increase the coupling efficiency. It offers an NA of 0.5 at 8× magnification. The Mitutoyo long-working-distance microscope lenses system offers an NA of 0.21 at 7.5× magnification. Compared with the Mitutoyo system, the developed long-working-distance microscope lenses system offers about twice the NA and four times the coupling efficiency. In the indirect X-ray imaging detector, a 50 µm-thick LuAG:Ce scintillator matching with the NA, and a high-speed visible-light CMOS FastCAM SAZ Photron camera are used. Test results show that the detector realized fast X-ray imaging with a frame rate of 100000 frames s−1 and fast X-ray microtomography with a temporal sampling rate up to 25 Hz (25 tomograms s−1).
- 23 August 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (5) , 1631-1637
High-efficiency fast X-ray imaging detector development at SSRF
Indirect X-ray imaging detectors consisting of scintillator screens, long-working-distance microscope lenses and scientific high-speed complementary metal-oxide semiconductor (CMOS) cameras are usually used to realize fast X-ray imaging with white-beam synchrotron radiation. However, the detector efficiency is limited by the coupling efficiency of the long-working-distance microscope lenses, which is only about 5%. A long-working-distance microscope lenses system with a large numerical aperture (NA) is designed to increase the coupling efficiency. It offers an NA of 0.5 at 8× magnification. The Mitutoyo long-working-distance microscope lenses system offers an NA of 0.21 at 7.5× magnification. Compared with the Mitutoyo system, the developed long-working-distance microscope lenses system offers about twice the NA and four times the coupling efficiency. In the indirect X-ray imaging detector, a 50 µm-thick LuAG:Ce scintillator matching with the NA, and a high-speed visible-light CMOS FastCAM SAZ Photron camera are used. Test results show that the detector realized fast X-ray imaging with a frame rate of 100000 frames s−1 and fast X-ray microtomography with a temporal sampling rate up to 25 Hz (25 tomograms s−1).
- Open Access
- 1 December 2016
- Published by MDPI AG in Remote Sensing
- Vol. 8 (12) , 991
Improving the Imaging Quality of Ghost Imaging Lidar via Sparsity Constraint by Time-Resolved Technique
Ghost imaging via sparsity constraint (GISC)—which is developing into a new staring imaging lidar—can obtain both the range information and spatial distribution of a remote target with the use of the measurements below the Nyquist limit. In this work, schematics of both two-dimensional (2D) and three-dimensional (3D) GISC lidar are introduced. Compared with the 2D GISC lidar, we demonstrate by both simulation and experimentally that the signal-to-noise ratio of the 3D GISC lidar can be dramatically enhanced when a time-resolved technique is used to record the target’s reflection signals and the orthogonal characteristic of the target’s 3D surface structure is taken as a priori in the image reconstruction process. Some characteristics of the 2D and 3D GISC lidar systems are also discussed.
- 1 December 2016
- Published by MDPI AG in Remote Sensing
- Vol. 8 (12) , 991
Open AccessImproving the Imaging Quality of Ghost Imaging Lidar via Sparsity Constraint by Time-Resolved Technique
Ghost imaging via sparsity constraint (GISC)—which is developing into a new staring imaging lidar—can obtain both the range information and spatial distribution of a remote target with the use of the measurements below the Nyquist limit. In this work, schematics of both two-dimensional (2D) and three-dimensional (3D) GISC lidar are introduced. Compared with the 2D GISC lidar, we demonstrate by both simulation and experimentally that the signal-to-noise ratio of the 3D GISC lidar can be dramatically enhanced when a time-resolved technique is used to record the target’s reflection signals and the orthogonal characteristic of the target’s 3D surface structure is taken as a priori in the image reconstruction process. Some characteristics of the 2D and 3D GISC lidar systems are also discussed.