Jinyeop Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jinyeop Lee has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Sungsu Park
School of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
4 shared publications - Abdurhaman Teyib Abafogi
School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea
3 shared publications - Danny van Noort
Division of Biophysics and Bioengineering, Department of Physics, Chemistry and Biology, Linköping University, Linköping, Sweden
2 shared publications - Jaewon Kim
School of Mechanical Engineering, Sungkyunkwan University, Suwon 16419, Korea
2 shared publications - Pan Kee Bae
BioNano Health Guard Research Center, 125 Gwahak-ro, Yuseong-gu, Daejeon 305-806, Korea
2 shared publications - Yong-Beom Shin
BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, Daejeon, Korea
2 shared publications
Latest Publications
- Open Access
Fast and easy disinfection of coronavirus-contaminated face masks using ozone gas produced by a dielectric barrier discharge plasma generator
Face masks are one of the currently available options for preventing the transmission of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which has caused the 2019 pandemic. However, with the increasing demand for protection, face masks are becoming limited in stock, and the concerned individuals and healthcare workers from many countries are now facing the issue of the reuse of potentially contaminated masks. Although various technologies already exist for the sterilization of medical equipment, most of them are not applicable for eliminating virus from face masks. Thus, there is an urgent need to develop a fast and easy method of disinfecting contaminated face masks. In this study, using a human coronavirus (HCoV-229E) as a surrogate for SARS-CoV-2 contamination on face masks, we show that the virus loses its infectivity to a human cell line (MRC-5) when exposed for a short period of time (1 min) to ozone gas produced by a dielectric barrier discharge plasma generator. Scanning electron microscopy and particulate filtration efficiency (PFE) tests revealed that there was no structural or functional deterioration observed in the face masks even after they underwent excessive exposure to ozone (five 1-minute exposures). Interestingly, for face masks exposed to ozone gas for 5 min, the amplification of HCoV-229E RNA by reverse transcription polymerase chain reaction suggested a loss of infectivity under the effect of ozone, primarily owing to the damage caused to viral envelopes or envelope proteins. Ozone gas is a strong oxidizing agent with the ability to kill viruses on hard-to-reach surfaces, including the fabric structure of face masks. These results suggest that it may be possible to rapidly disinfect contaminated face masks using a plasma generator in a well-ventilated place.
Open AccessFast and easy disinfection of coronavirus-contaminated face masks using ozone gas produced by a dielectric barrier discharge plasma generator
Face masks are one of the currently available options for preventing the transmission of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which has caused the 2019 pandemic. However, with the increasing demand for protection, face masks are becoming limited in stock, and the concerned individuals and healthcare workers from many countries are now facing the issue of the reuse of potentially contaminated masks. Although various technologies already exist for the sterilization of medical equipment, most of them are not applicable for eliminating virus from face masks. Thus, there is an urgent need to develop a fast and easy method of disinfecting contaminated face masks. In this study, using a human coronavirus (HCoV-229E) as a surrogate for SARS-CoV-2 contamination on face masks, we show that the virus loses its infectivity to a human cell line (MRC-5) when exposed for a short period of time (1 min) to ozone gas produced by a dielectric barrier discharge plasma generator. Scanning electron microscopy and particulate filtration efficiency (PFE) tests revealed that there was no structural or functional deterioration observed in the face masks even after they underwent excessive exposure to ozone (five 1-minute exposures). Interestingly, for face masks exposed to ozone gas for 5 min, the amplification of HCoV-229E RNA by reverse transcription polymerase chain reaction suggested a loss of infectivity under the effect of ozone, primarily owing to the damage caused to viral envelopes or envelope proteins. Ozone gas is a strong oxidizing agent with the ability to kill viruses on hard-to-reach surfaces, including the fabric structure of face masks. These results suggest that it may be possible to rapidly disinfect contaminated face masks using a plasma generator in a well-ventilated place.
- Open Access
3D-Printed Modular Microfluidic Device Enabling Preconcentrating Bacteria and Purifying Bacterial DNA in Blood for Improving the Sensitivity of Molecular Diagnostics
Molecular diagnostics for sepsis is still a challenge due to the presence of compounds that interfere with gene amplification and bacteria at concentrations lower than the limit of detection (LOD). Here, we report on the development of a 3D printed modular microfluidic device (3DpmμFD) that preconcentrates bacteria of interest in whole blood and purifies their genomic DNA (gDNA). It is composed of a W-shaped microchannel and a conical microchamber. Bacteria of interest are magnetically captured from blood in the device with antibody conjugated magnetic nanoparticles (Ab-MNPs) at 5 mL/min in the W-shaped microchannel, while purified gDNA of the preconcentrated bacteria is obtained with magnetic silica beads (MSBs) at 2 mL/min in the conical microchamber. The conical microchamber was designed to be connected to the microchannel after the capturing process using a 3D-printed rotary valve to minimize the exposure of the MSBs to interfering compounds in blood. The pretreatment process of spiked blood (2.5 mL) can be effectively completed within about 50 min. With the 3DpmμFD, the LOD for the target microorganism Escherichia coli O157:H7 measured by both polymerase chain reaction (PCR) with electrophoresis and quantitative PCR was 10 colony forming unit (CFU) per mL of whole blood. The results suggest that our method lowers the LOD of molecular diagnostics for pathogens in blood by providing bacterial gDNA at high purity and concentration.
Open Access3D-Printed Modular Microfluidic Device Enabling Preconcentrating Bacteria and Purifying Bacterial DNA in Blood for Improving the Sensitivity of Molecular Diagnostics
Molecular diagnostics for sepsis is still a challenge due to the presence of compounds that interfere with gene amplification and bacteria at concentrations lower than the limit of detection (LOD). Here, we report on the development of a 3D printed modular microfluidic device (3DpmμFD) that preconcentrates bacteria of interest in whole blood and purifies their genomic DNA (gDNA). It is composed of a W-shaped microchannel and a conical microchamber. Bacteria of interest are magnetically captured from blood in the device with antibody conjugated magnetic nanoparticles (Ab-MNPs) at 5 mL/min in the W-shaped microchannel, while purified gDNA of the preconcentrated bacteria is obtained with magnetic silica beads (MSBs) at 2 mL/min in the conical microchamber. The conical microchamber was designed to be connected to the microchannel after the capturing process using a 3D-printed rotary valve to minimize the exposure of the MSBs to interfering compounds in blood. The pretreatment process of spiked blood (2.5 mL) can be effectively completed within about 50 min. With the 3DpmμFD, the LOD for the target microorganism Escherichia coli O157:H7 measured by both polymerase chain reaction (PCR) with electrophoresis and quantitative PCR was 10 colony forming unit (CFU) per mL of whole blood. The results suggest that our method lowers the LOD of molecular diagnostics for pathogens in blood by providing bacterial gDNA at high purity and concentration.
- Open Access
- 16 February 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (2) , 203
Integrated Microfluidic Preconcentration and Nucleic Amplification System for Detection of Influenza A Virus H1N1 in Saliva
Influenza A viruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (μFPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the μFPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device.
- 16 February 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (2) , 203
Open AccessIntegrated Microfluidic Preconcentration and Nucleic Amplification System for Detection of Influenza A Virus H1N1 in Saliva
Influenza A viruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (μFPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the μFPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device.
- Open Access
- 17 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 472
A 3D-Printed Millifluidic Platform Enabling Bacterial Preconcentration and DNA Purification for Molecular Detection of Pathogens in Blood
Molecular detection of pathogens in clinical samples often requires pretreatment techniques, including immunomagnetic separation and magnetic silica-bead-based DNA purification to obtain the purified DNA of pathogens. These two techniques usually rely on handling small tubes containing a few millilitres of the sample and manual operation, implying that an automated system encompassing both techniques is needed for larger quantities of the samples. Here, we report a three-dimensional (3D)-printed millifluidic platform that enables bacterial preconcentration and genomic DNA (gDNA) purification for improving the molecular detection of target pathogens in blood samples. The device consists of two millichannels and one chamber, which can be used to preconcentrate pathogens bound to antibody-conjugated magnetic nanoparticles (Ab-MNPs) and subsequently extract gDNA using magnetic silica beads (MSBs) in a sequential manner. The platform was able to preconcentrate very low concentrations (1–1000 colony forming units (CFU)) of Escherichia coli O157:H7 and extract their genomic DNA in 10 mL of buffer and 10% blood within 30 min. The performance of the platform was verified by detecting as low as 1 CFU of E. coli O157:H7 in 10% blood using either polymerase chain reaction (PCR) with post gel electrophoresis or quantitative PCR. The results suggest that the 3D-printed millifluidic platform is highly useful for lowering the limitations on molecular detection in blood by preconcentrating the target pathogen and isolating its DNA in a large volume of the sample.
- 17 September 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (9) , 472
Open AccessA 3D-Printed Millifluidic Platform Enabling Bacterial Preconcentration and DNA Purification for Molecular Detection of Pathogens in Blood
Molecular detection of pathogens in clinical samples often requires pretreatment techniques, including immunomagnetic separation and magnetic silica-bead-based DNA purification to obtain the purified DNA of pathogens. These two techniques usually rely on handling small tubes containing a few millilitres of the sample and manual operation, implying that an automated system encompassing both techniques is needed for larger quantities of the samples. Here, we report a three-dimensional (3D)-printed millifluidic platform that enables bacterial preconcentration and genomic DNA (gDNA) purification for improving the molecular detection of target pathogens in blood samples. The device consists of two millichannels and one chamber, which can be used to preconcentrate pathogens bound to antibody-conjugated magnetic nanoparticles (Ab-MNPs) and subsequently extract gDNA using magnetic silica beads (MSBs) in a sequential manner. The platform was able to preconcentrate very low concentrations (1–1000 colony forming units (CFU)) of Escherichia coli O157:H7 and extract their genomic DNA in 10 mL of buffer and 10% blood within 30 min. The performance of the platform was verified by detecting as low as 1 CFU of E. coli O157:H7 in 10% blood using either polymerase chain reaction (PCR) with post gel electrophoresis or quantitative PCR. The results suggest that the 3D-printed millifluidic platform is highly useful for lowering the limitations on molecular detection in blood by preconcentrating the target pathogen and isolating its DNA in a large volume of the sample.